💾 Archived View for cosmic.voyage › Sakura › Datalink%20fix%20-%20log%20001.txt captured on 2024-06-16 at 12:44:39.
View Raw
More Information
⬅️ Previous capture (2024-03-21)
-=-=-=-=-=-=-
logon as: admin
admin@telcom.sakura's password:
^L
TELESYS 4.00.4421 (c) Sterncomm
admin:disk0\telesys\system >eventvwr /journal:system /lastEvents:10 /brief
Event Viewer
Displaying last 10 events:
| ID |LogLvl| Source | Date/Time | Short description |
+----+------+----------------+-----------------+------------------------------+
|3243| INF | LineTools |08-04-73 22:48:43|Call statistics |
|3242| INF | DHCPserv |08-04-73 22:48:31|DHCP client lease expiration |
|3241| ERR | LineTools |08-04-73 22:42:01|CO 3 line failed to connect |
|3240| INF | telmailer |08-04-73 22:40:00|Mailbox compacting in progress|
|3239| INF | DNSserv |08-04-73 22:39:28|DNS zone S/N incremented |
|3238| WRN | DirectoryDB |08-04-73 22:35:39|Unbound directory entries |
|3237| INF | DirectoryDB |08-04-73 22:35:38|Directory defrag complete |
|3236| WRN | NTPsync |08-04-73 22:33:17|Cannot sync with NTP server |
|3235| ERR | disk |08-04-73 22:32:59|Bad block on \\.\ata0\disk0 |
|3234| WRN | UPS |08-04-73 22:28:45|Backup battery low voltage |
admin:disk0\telesys\system >linetools
^L
LINETOOLS 1.84
(c) Sterncomm
1) Line statistics and status
2) Line configuration
3) Internal switching
4) Trunk/CO switching
5) Subscriber services
6) Billing output
7) Switchboard configuration
8) Numbering plan
9) Datalink
10) Switchboard controller nodes
q) Exit
Select: 4
- * TRUNK/CO SWITCHING SETTINGS **
Switchboard \\.\exch\swbd0
1) Select switchboard
2) Trunk/CO hunting groups
3) Trunk/CO line configuration
Select: 3
Enter line number [1-9, C-select trunk controller]: 3
- ******************************************************************************
Line: \\.\exch\swbd0\cardbus1\trunkctl0\lco2
1) Line type: Single-pair Analog
2) Inter-exchange protocol: SS7
3) Inbound allow: True
4) Outbound allow: True
5) Group outbound restrictions: None
6) Inbound restrictions: None
7) Billing table: Table 1
8) Trunk/CO hunting group: Group 1
9) Call priority handling: >>
10) Signal generator: Generator 0 (\\.\exch\swbd0\sgen0)
11) Inbound call routing: >>
12) Line failure counter: 2 [Reset]
13) Measure line parameters: >>
14) Line state: Down, line alarm
Select: 13
LineTools will execute line parameters test using switchboard's diagnostics
card. The line will be out of service for about 2 minutes. Results are logged
in switchboard controller's event log.
During the test ** DO NOT ** disconnect trunk/CO interface in the switchboard!
Do you wish to proceed? [[Y]es/[N]o/[B]ackground]: Y
Please wait...
Line test finished.
Line idle voltage: 48.4 V
Loop state: Open
400 Hz Generator: OK
Pulse dialing module: OK
DTMF module: OK
SS7 controller: OK
Off-hook attempt: OK
CO-inter dialing attempt: OK
CO-ext dialing attempt: ERROR
Carrier freq: 1200/---- Hz
SNR: -- dB
Last disconnect: Line connection dropped
Press any key to close...
- ******************************************************************************
Line: \\.\exch\swbd0\cardbus1\trunkctl0\lco2
1) Line type: Single-pair Analog
2) Inter-exchange protocol: SS7
3) Inbound allow: True
4) Outbound allow: True
5) Group outbound restrictions: None
6) Inbound restrictions: None
7) Billing table: Table 1
8) Trunk/CO hunting group: Group 1
9) Call priority handling: >>
10) Signal generator: Generator 0 (\\.\exch\swbd0\sgen0)
11) Inbound call routing: >>
12) Line failure counter: 2 [Reset]
13) Measure line parameters: >>
14) Line state: Down, line alarm
Select: q
^L
LINETOOLS 1.84
(c) Sterncomm
1) Line statistics and status
2) Line configuration
3) Internal switching
4) Trunk/CO switching
5) Subscriber services
6) Billing output
7) Switchboard configuration
8) Numbering plan
9) Datalink
10) Switchboard controller nodes
q) Exit
Select: q
Are you sure you want to quit? [[Y]es/[N]o]: y
^L
admin:disk0\telesys\system >mikoterm
MikoTerm 0.95
- [N]ew* [O]pen [T]erminal [Q]uit
New connection:
Name: [_______]
Protocol: [Serial ]
Port: [ COM1 ]
Rate: [115200 ]
Data bits: [ 8 ]
Stop bits: [ 1 ]
Parity: [ None ]
Flow control: [RTS/CTS]
Connected: COM1
To disconnect press Alt+H.
at
OK
at&v0
- * Pentacom SpaceLink 140 **
Options:
B0 E1 F1 L0 M0 Q0 T1 V1 X3 Y0
BAUD=115200 PARITY=N WORDLEN=8
DIAL=DIGITAL ON HOOK
&A3 &B1 &C1 &D0 &G0 &H1 &I0 &K1
&M4 &N0 &P1 &R2 &S0 &T5 &U0 &Y1
S00=000 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002
S07=060 S08=002 S09=006 S10=014 S11=070 S12=050 S13=000
S15=000 S16=000 S18=000 S19=000 S21=010 S22=017 S23=019
S25=005 S27=001 S28=008 S29=020 S30=000 S31=128 S32=002
S33=000 S34=000 S35=000 S36=014 S38=000 S39=012 S40=000
S41=004 S42=000 S43=112
ID: D0:FF:14:SAKURA_QEC______/0
LAST CONNECTION: FF:00:10:MEC_RELAY_QEC__/4
OK
at&v6
Chars sent 0 Chars Received 0
Chars lost 142
Octets sent 0 Octets Received 0
Blocks sent 0 Blocks Received 0
Blocks resent 4
Retrains Requested 0 Retrains Granted 0
Line Reversals 0 Blers 0
Link Timeouts 0 Link Naks 10
Data Compression ------
Equalization ----
Fallback -------
Protocol ----
Speed -----/-----
Last Call 00:00:00
Disconnect Reason is No signal or SNR too low
OK
at*re=##:##:##:RELAY_001______/#
Station ID added to allowed list.
OK
atdd ##:##:##:RELAY_001______/#
Station unknown. Set position or align antenna to station.
ERROR
at*an=?
Antenna list:
0 Automatic
1 PD-MW-10M-CON0
2 PD-MW-05M-CON0
3 PD-MW-05M-CON1
4 DI-HF-200-CON2
5 UD-HF-300-CON2
OK
at*an=5
OK
at*co=2
OK
SIGNAL AN5 -98dBm 02:00:AC:RELAY_001______/0
at*df=1
Direction Finder init: Antenna 1
OK
at*aa=con0
OK
at&v10
Antenna position:
CON0: 1: r=177 a=-79
2: r=095 a=+00
CON1: 3: r=339 a=-12
CON2: 4: r=338 a=+04
5: UNSUPPORTED
OK
SIGNAL AN5 -99dBm 02:00:AC:RELAY_001______/0
SIGNAL AN1 -76dBm 02:00:AC:RELAY_001______/0
SIGNAL AN2 -57dBm 02:00:AC:RELAY_001______/0
at*sy=02:00:AC:RELAY_001______/#
Synchronization in progress...
Node information received and stored.
OK
at*an=1
OK
at*co=0
OK
atdd 02:00:AC:RELAY_001______/0;
SIGNAL AN1 -49dBm 02:00:AC:RELAY_001______/0
CONNECT 57333/V42bis/ARQ/LAPM/DTConn2
OK
at*lk=02:00:AC:RELAY_001______/0
OK
at*an=0
OK
at*un=02:00:AC:RELAY_001______/0$sakura
OK
at*up=02:00:AC:RELAY_001______/0$########
OK
ato0
OK
M-H
## MikoTerm Menu
^C Capture
^- Rate Down
^+ Rate Up
^D Download
^U Upload
^O Options
^H Hang Up (Disconnect)
^C Exit
Option: ^C
Are you sure? (Y/N): y
Disconnected.
See you!
^L
admin:disk0\telesys\system >linetools
^L
LINETOOLS 1.84
(c) Sterncomm
1) Line statistics and status
2) Line configuration
3) Internal switching
4) Trunk/CO switching
5) Subscriber services
6) Billing output
7) Switchboard configuration
8) Numbering plan
9) Datalink
10) Switchboard controller nodes
q) Exit
Select: 4
- * TRUNK/CO SWITCHING SETTINGS **
Switchboard \\.\exch\swbd0
1) Select switchboard
2) Trunk/CO hunting groups
3) Trunk/CO line configuration
Select: 3
Enter line number [1-9, C-select trunk controller]: 3
- ******************************************************************************
Line: \\.\exch\swbd0\cardbus1\trunkctl0\lco2
1) Line type: Single-pair Analog
2) Inter-exchange protocol: SS7
3) Inbound allow: True
4) Outbound allow: True
5) Group outbound restrictions: None
6) Inbound restrictions: None
7) Billing table: Table 1
8) Trunk/CO hunting group: Group 1
9) Call priority handling: >>
10) Signal generator: Generator 0 (\\.\exch\swbd0\sgen0)
11) Inbound call routing: >>
12) Line failure counter: 2 [Reset]
13) Measure line parameters: >>
14) Line state: Down, line alarm
Select: 14
State: Down, line alarm
Set new state:
1) Down
2) Up
Select: 1
- ******************************************************************************
Line: \\.\exch\swbd0\cardbus1\trunkctl0\lco2
1) Line type: Single-pair Analog
2) Inter-exchange protocol: SS7
3) Inbound allow: True
4) Outbound allow: True
5) Group outbound restrictions: None
6) Inbound restrictions: None
7) Billing table: Table 1
8) Trunk/CO hunting group: Group 1
9) Call priority handling: >>
10) Signal generator: Generator 0 (\\.\exch\swbd0\sgen0)
11) Inbound call routing: >>
12) Line failure counter: 2 [Reset]
13) Measure line parameters: >>
14) Line state: Down
Select: 12
Reset line failure counter? [[Y]es/[N]o/[S]how]: S
CO 3 line alarms:
[!] ALARM 02 - Unexpected connection drop
[!] ALARM 14 - 50 failed dial attempts
Reset line failure counter? [[Y]es/[N]o/[S]how]: Y
Line failure counter reset!
- ******************************************************************************
Line: \\.\exch\swbd0\cardbus1\trunkctl0\lco2
1) Line type: Single-pair Analog
2) Inter-exchange protocol: SS7
3) Inbound allow: True
4) Outbound allow: True
5) Group outbound restrictions: None
6) Inbound restrictions: None
7) Billing table: Table 1
8) Trunk/CO hunting group: Group 1
9) Call priority handling: >>
10) Signal generator: Generator 0 (\\.\exch\swbd0\sgen0)
11) Inbound call routing: >>
12) Line failure counter: 2 [Reset]
13) Measure line parameters: >>
14) Line state: Down
Select: 14
State: Down
Set new state:
1) Down
2) Up
Select: 2
Please wait...
- ******************************************************************************
Line: \\.\exch\swbd0\cardbus1\trunkctl0\lco2
1) Line type: Single-pair Analog
2) Inter-exchange protocol: SS7
3) Inbound allow: True
4) Outbound allow: True
5) Group outbound restrictions: None
6) Inbound restrictions: None
7) Billing table: Table 1
8) Trunk/CO hunting group: Group 1
9) Call priority handling: >>
10) Signal generator: Generator 0 (\\.\exch\swbd0\sgen0)
11) Inbound call routing: >>
12) Line failure counter: 2 [Reset]
13) Measure line parameters: >>
14) Line state: Up, operational
Select: q
^L
LINETOOLS 1.84
(c) Sterncomm
1) Line statistics and status
2) Line configuration
3) Internal switching
4) Trunk/CO switching
5) Subscriber services
6) Billing output
7) Switchboard configuration
8) Numbering plan
9) Datalink
10) Switchboard controller nodes
q) Exit
Select: q
Are you sure you want to quit? [[Y]es/[N]o]: y
^L
admin:disk0\telesys\system >newslink
^L
- ******************************************************************************
- NEWSLINK 1.8.20 *
- ******************************************************************************
- | File | Send/Receive | News Accounts | Help | *
- ******************************************************************************
- maki@news.sakura * *
- L local.general * Select news account to read news. *
- L local.admins * *
- L sakuralink.general * *
- * *
- maki@qec.net * *
- L qecnet.general * *
- L qecnet.marketplace * *
- L qecnet.rec.games * *
- L qecnet.tech.ships * *
- L qecnet.test * *
- * *
- * *
- * *
- * *
- * *
- ******************************************************************************
- Disconnected * TAB to move between windows *
- ******************************************************************************
===============================================================================
Connected: maki@qec.net
New newsgroup message
Newsgroup: qecnet.test
Encoding: UTF-8
Message format: Plain text
Subject: test, new connection
Hello, testing after a connection drop. Does it work?
===============================================================================
[Send] [Save as draft] [Cancel]
Sending... Message sent!
^L
admin:disk0\telesys\system >exit
Disconnected.