💾 Archived View for gopher.zcrayfish.soy › 0 › irc › New_house_pump.txt captured on 2024-05-12 at 15:26:41.

View Raw

More Information

⬅️ Previous capture (2022-03-01)

-=-=-=-=-=-=-

New pump will use a plastic AVC, such as Merril's MAC1 or Home Depot's TC2120
http://www.homedepot.com/p/Parts20-Plastic-Fitting-Air-Volume-Control-Kit-TC2120/100191576#product_description
http://www.merrillmfg.com/product/04-Floats/AirVolume/aircharger.php
http://www.burcam.com/files/Web/Photos/750845.jpg

Tank will be 42 gallon epoxy lined:
https://www.google.com/shopping/product/1742668368425330575



Preferred pumps:
GOULDS PUMPS:
PUMP MODEL	JET	PACKER ADAPTER	CONTROL VALVE
SJ15		FP2-29	AWD2		integrated into pump
HSJ15		FP2-29	AWJ2		AV22KIT
HSJ15N		FP2-29	AWJ2
SJ20		FP2-29	AWD2		integrated into pump
HSJ20		FP2-29	AWD2		AV22KIT
HSJ20N		FP2-29	AWJ2


PENTAIR PUMPS:
BRAND/MODEL	JET
STA-RITE MSF-7	8AP	(package PKG 1-8AP, includes jet, o-rings, and packer)

Well is 210 feet deep
Casing extends to 200 feet, PVC 2"
Remaining 10 feet is a 15 slot screen
Static water level is 60 feet
Yield is 25 GPM



Jet should have 34' tailpipe attached
End of assembly shoudl be at least 5' from bottom of well, 11' better in case screen is small diameter
Jet will be at 165' mark


Aiming for 7-10 GPM