💾 Archived View for gemini.bortzmeyer.org › rfc-mirror › rfc20.txt captured on 2024-02-05 at 12:58:04.

View Raw

More Information

⬅️ Previous capture (2021-11-30)

-=-=-=-=-=-=-







Network Working Group                                          Vint Cerf
Request for Comments: 20                                            UCLA
                                                        October 16, 1969


                  ASCII format for Network Interchange

   For concreteness, we suggest the use of standard 7-bit ASCII embedded
   in an 8 bit byte whose high order bit is always 0.  This leads to the
   standard code given on the attached page, copies from USAS X3, 4-
   1968.  This code will be used over HOST-HOST primary connections.
   Break characters will be defined by the receiving remote host, e.g.
   SRI uses "." (ASCII X'2E' or 2/14) as the end-of-line character,
   where as UCLA uses X'OD' or 0/13 (carriage return).




USA Standard Code for Information Interchange

1. Scope

   This coded character set is to be used for the general interchange of
   information among information processing systems, communication
   systems, and associated equipment.


























Cert                                                            [Page 1]

RFC 20            ASCII format for Network Interchange      October 1969


2. Standard Code

|----------------------------------------------------------------------|
  B  \ b7 ------------>| 0   | 0   | 0   | 0   | 1   | 1   | 1   | 1   |
   I  \  b6 ---------->| 0   | 0   | 1   | 1   | 0   | 0   | 1   | 1   |
    T  \   b5 -------->| 0   | 1   | 0   | 1   | 0   | 1   | 0   | 1   |
     S                 |-----------------------------------------------|
               COLUMN->| 0   | 1   | 2   | 3   | 4   | 5   | 6   | 7   |
|b4 |b3 |b2 |b1 | ROW  |     |     |     |     |     |     |     |     |
+----------------------+-----------------------------------------------+
| 0 | 0 | 0 | 0 | 0    | NUL | DLE | SP  | 0   | @   | P   |   ` |   p |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 0 | 0 | 0 | 1 | 1    | SOH | DC1 | !   | 1   | A   | Q   |   a |   q |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 0 | 0 | 1 | 0 | 2    | STX | DC2 | "   | 2   | B   | R   |   b |   r |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 0 | 0 | 1 | 1 | 3    | ETX | DC3 | #   | 3   | C   | S   |   c |   s |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 0 | 1 | 0 | 0 | 4    | EOT | DC4 | $   | 4   | D   | T   |  d  |   t |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 0 | 1 | 0 | 1 | 5    | ENQ | NAK | %   | 5   | E   | U   |  e  |   u |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 0 | 1 | 1 | 0 | 6    | ACK | SYN | &   | 6   | F   | V   |  f  |   v |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 0 | 1 | 1 | 1 | 7    | BEL | ETB | '   | 7   | G   | W   |  g  |   w |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 0 | 0 | 0 | 8    | BS  | CAN | (   | 8   | H   | X   |  h  |   x |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 0 | 0 | 1 | 9    | HT  | EM  | )   | 9   | I   | Y   |  i  |   y |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 0 | 1 | 0 | 10   | LF  | SUB | *   | :   | J   | Z   |  j  |   z |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 0 | 1 | 1 | 11   | VT  | ESC | +   |  ;  | K   | [   |  k  |   { |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 1 | 0 | 0 | 12   | FF  | FS  | ,   | <   | L   | \   |  l  |   | |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 1 | 0 | 1 | 13   | CR  | GS  | -   | =   | M   | ]   |  m  |   } |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 1 | 1 | 0 | 14   | SO  | RS  | .   | >   | N   | ^   |  n  |   ~ |
|---|---|---|---|------|-----|-----|-----|-----|-----|-----|-----|-----|
| 1 | 1 | 1 | 1 | 15   | SI  | US  | /   | ?   | O   | _   |  o  | DEL |
+----------------------+-----------------------------------------------+









Cert                                                            [Page 2]

RFC 20            ASCII format for Network Interchange      October 1969


3. Character Representation and Code Identification

   The standard 7-bit character representation, with b7 the high-order
   bit and b1 the low-order bit, is shown below:

   EXAMPLE: The bit representation for the character "K," positioned in
   column 4, row 11, is

   b7 b6 b5 b4 b3 b2 b1
   1  0  0  1  0  1  1


   The code table position for the character "K" may also be represented
   by the notation "column 4, row 11" or alternatively as "4/11."  The
   decimal equivalent of the binary number formed by bits b7, b6, and
   b5, collectively, forms the column number, and the decimal equivalent
   of the binary number formed by bits b4, b3, b2, and b1, collectively,
   forms the row number.

   The standard code may be identified by the use of the notation ASCII
   or USASCII.

   The notation ASCII (pronounced as'-key) or USASCII (pronounced you-
   sas'-key) should ordinarily be taken to mean the code prescribed by
   the latest issue of the standard.  To explicitly designate a
   particular (perhaps prior) issue, the last two digits of the year of
   issue may be appended, as, "ASCII 63" or "USASCII 63".
























Cert                                                            [Page 3]

RFC 20            ASCII format for Network Interchange      October 1969


4. Legend

4.1 Control Characters

   NUL Null                                DLE Data Link Escape (CC)

   SOH Start of Heading (CC)               DC1 Device Control 1

   STX Start of Text (CC)                  DC2 Device Control 2

   ETX End of Text (CC)                    DC3 Device Control 3

   EOT End of Transmission (CC)            DC4 Device Control 4 (Stop)

   ENQ Enquiry (CC)                        NAK Negative Acknowledge (CC)

   ACK Acknowledge (CC)                    SYN Synchronous Idle (CC)

   BEL Bell (audible or                    ETB End of Transmission
       attention signal)                       Block (CC)

   BS Backspace (FE)                       CAN Cancel

   HT Horizontal Tabulation                EM End of Medium
      (punched card skip) (FE)

   LF Line Feed (FE)                       SUB Substitute

   VT Vertical Tabulation (FE)             ESC Escape

   FF Form Feed (FE)                       FS File Separator IS)

   CR Carriage Return (FE)                 GS Group Separator (IS)

   SO Shift Out                            RS Record Separator (IS)

   SI Shift In                             US Unit Separator (IS)

                                           DEL Delete [1]

   ________
   NOTE: (CC) Communication Control
         (FE) Format Effector
         (IS) Information Separator
   [1] In the strict sense, DEL is not a control character.  (See 5.2)






Cert                                                            [Page 4]

RFC 20            ASCII format for Network Interchange      October 1969


4.2 Graphic Characters

   Column/Row  Symbol      Name

   2/0         SP          Space (Normally Non-Printing)
   2/1         !           Exclamation Point
   2/2         "           Quotation Marks (Diaeresis [2])
   2/3         #           Number Sign [3,4]
   2/4         $           Dollar Sign
   2/5         %           Percent
   2/6         &           Ampersand
   2/7         '           Apostrophe (Closing Single Quotation Mark
                           Acute Accent [2])
   2/8         (           Opening Parenthesis
   2/9         )           Closing Parenthesis
   2/10        *           Asterisk
   2/11        +           Plus
   2/12        ,           Comma (Cedilla [2])
   2/13        -           Hyphen (Minus)
   2/14        .           Period (Decimal Point)
   2/15        /           Slant
   3/10        :           Colon
   3/11        ;           Semicolon
   3/12        <           Less Than
   3/13        =           Equals
   3/14        >           Greater Than
   3/15        ?           Question Mark
   4/0         @           Commercial At [3]
   5/11        [           Opening Bracket [3]
   5/12       \            Reverse Slant [3]
   5/13        ]           Closing Bracket [3]
   5/14        ^           Circumflex [2,3]
   5/15        _           Underline
   6/0         `           Grave Accent [2,3] (Opening Single Quotation
                                   Mark)
   7/11        {           Opening Brace [3]
   7/12        |           Vertical Line [3]
   7/13        }           Closing Brace [3]
   7/14        ~           Overline [3] (Tilde [2]; General Accent [2])

   ________
      2 The use of the symbols in 2/2, 2/7, 2/12, 5/14, /6/0, and 7/14
   as diacritical marks is described in Appendix A, A5.2
      3 These characters should not be used in international interchange
   without determining that there is agreement between sender and
   recipient.  (See Appendix B4.)
      4 In applications where there is no requirement for the symbol #,
   the symbol (Pounds Sterling) may be used in position 2/3.



Cert                                                            [Page 5]

RFC 20            ASCII format for Network Interchange      October 1969


5. Definitions

5.1 General

      (CC)  Communication Control: A functional character intended to
   control or facilitate transmission of information over communication
   networks.
      (FE)  Format Effector: A functional character which controls the
   layout or positioning of information in printing or display devices.
      (IS) Information Separator: A character which is used to separate
   and qualify information in a logical sense.  There is a group of four
   such characters, which are to be used in a hierarchical order.

5.2 Control Characters

      NUL (Null): The all-zeros character which may serve to accomplish
   time fill and media fill.
      SOH (Start of Heading): A communication control character used at
   the beginning of a sequence of characters which constitute a
   machine-sensible address or routing information.  Such a sequence is
   referred to as the "heading."  An STX character has the effect of
   terminating a heading.
      STX (Start of Text): A communication control character which
   precedes a sequence of characters that is to be treated as an entity
   and entirely transmitted through to the ultimate destination.  Such a
   sequence is referred to as "text."  STX may be used to terminate a
   sequence of characters started by SOH.
      ETX (End of Text): A communication control character used to
   terminate a sequence of characters started with STX and transmitted
   as an entity.
      EOT (End of Transmission): A communication control character used
   to indicate the conclusion of a transmission, which may have
   contained one or more texts and any associated headings.
      ENQ (Enquiry): A communication control character used in data
   communication systems as a request for a response from a remote
   station.  It may be used as a "Who Are You" (WRU) to obtain
   identification, or may be used to obtain station status, or both.
      ACK (Acknowledge): A communication control character transmitted
   by a receiver as an affirmative response to a sender.
      BEL (Bell): A character for use when there is a need to call for
   human attention.  It may control alarm or attention devices.
      BS (Backspace): A format effector which controls the movement of
   the printing position one printing space backward on the same
   printing line.  (Applicable also to display devices.)
      HT (Horizontal Tabulation): A format effector which controls the
   movement of the printing position to the next in a series of
   predetermined positions along the printing line.  (Applicable also to
   display devices and the skip function on punched cards.)



Cert                                                            [Page 6]

RFC 20            ASCII format for Network Interchange      October 1969


      LF (Line Feed): A format effector which controls the movement of
   the printing position to the next printing line.  (Applicable also to
   display devices.) Where appropriate, this character may have the
   meaning "New Line" (NL), a format effector which controls the
   movement of the printing point to the first printing position on the
   next printing line.  Use of this convention requires agreement
   between sender and recipient of data.
      VT (Vertical Tabulation): A format effector which controls the
   movement of the printing position to the next in a series of
   predetermined printing lines.  (Applicable also to display devices.)
      FF (Form Feed): A format effector which controls the movement of
   the printing position to the first pre-determined printing line on
   the next form or page.  (Applicable also to display devices.)
      CR (Carriage Return): A format effector which controls the
   movement of the printing position to the first printing position on
   the same printing line.  (Applicable also to display devices.)
      SO (Shift Out): A control character indicating that the code
   combinations which follow shall be interpreted as outside of the
   character set of the standard code table until a Shift In character
   is reached.
      SI (Shift In): A control character indicating that the code
   combinations which follow shall be interpreted according to the
   standard code table.
      DLE (Data Link Escape): A communication control character which
   will change the meaning of a limited number of contiguously following
   characters.  It is used exclusively to provide supplementary controls
   in data communication networks.
      DC1, DC2, DC3, DC4 (Device Controls): Characters for the control
   of ancillary devices associated with data processing or
   telecommunication systems, more especially switching devices "on" or
   "off."  (If a single "stop" control is required to interrupt or turn
   off ancillary devices, DC4 is the preferred assignment.)
      NAK (Negative Acknowledge): A communication control character
   transmitted by a receiver as a negative response to the sender.
      SYN (Synchronous Idle): A communication control character used by
   a synchronous transmission system in the absence of any other
   character to provide a signal from which synchronism may be achieved
   or retained.
      ETB (End of Transmission Block): A communication control character
   used to indicate the end of a block of data for communication
   purposes.  ETB is used for blocking data where the block structure is
   not necessarily related to the processing format.
      CAN (Cancel): A control character used to indicate that the data
   with which it is sent is in error or is to be disregarded.
      EM (End of Medium): A control character associated with the sent
   data which may be used to identify the physical end of the medium, or
   the end of the used, or wanted, portion of information recorded on a
   medium.



Cert                                                            [Page 7]

RFC 20            ASCII format for Network Interchange      October 1969


(The position of this character does not necessarily correspond to the
   physical end of the medium.)

      SUB (Substitute): A character that may be substituted for a
   character which is determined to be invalid or in error.
      ESC (Escape): A control character intended to provide code
   extension (supplementary characters) in general information
   interchange.  The Escape character itself is a prefix affecting the
   interpretation of a limited number of contiguously following
   characters.
      FS (File Separator), GS (Group Separator), RS (Record Separator),
   and US (Unit Separator): These information separators may be used
   within data in optional fashion, except that their hierarchical
   relationship shall be: FS is the most inclusive, then GS, then RS,
   and US is least inclusive.  (The content and length of a File, Group,
   Record, or Unit are not specified.)
      DEL (Delete): This character is used primarily to "erase" or
   "obliterate" erroneous or unwanted characters in perforated tape.
   (In the strict sense, DEL is not a control character.)

5.3 Graphic Characters

      SP (Space): A normally non-printing graphic character used to
   separate words.  It is also a format effector which controls the
   movement of the printing position, one printing position forward.
   (Applicable also to display devices.)

6. General Considerations

   6.1 This standard does not define the means by which the coded set is
   to be recorded in any physical medium, nor does it include any
   redundancy or define techniques for error control.  Further, this
   standard does not define data communication character structure, data
   communication formats, code extension techniques, or graphic
   representation of control characters.

   6.2 Deviations from the standard may create serious difficulties in
   information interchange and should be used only with full cognizance
   of the parties involved.

   6.3 The relative sequence of any two characters, when used as a basis
   for collation, is defined by their binary values.









Cert                                                            [Page 8]

RFC 20            ASCII format for Network Interchange      October 1969


   6.4 No specific meaning is prescribed for any of the graphics in the
   code table except that which is understood by the users.
   Furthermore, this standard does not specify a type style for the
   printing or display of the various graphic characters.  In specific
   applications, it may be desirable to employ distinctive styling of
   individual graphics to facilitate their use for specific purposes as,
   for example, to stylize the graphics in code positions 2/1 and 5/15
   into those frequently associated with logical OR (|) and logical NOT
   (252), respectively.

   6.5 The appendixes to this standard contain additional information on
   the design and use of this code.



         [ This RFC was put into machine readable form for entry ]
           [ into the online RFC archives by Robbie Bennet 9/99]


































Cert                                                            [Page 9]