💾 Archived View for gemini.bortzmeyer.org › rfc-mirror › rfc9270.txt captured on 2023-12-28 at 15:42:03.
⬅️ Previous capture (2023-01-29)
-=-=-=-=-=-=-
Internet Engineering Task Force (IETF) J. He Request for Comments: 9270 I. Busi Updates: 4872, 4873 Huawei Technologies Category: Standards Track J. Ryoo ISSN: 2070-1721 B. Yoon ETRI P. Park KT August 2022 GMPLS Signaling Extensions for Shared Mesh Protection Abstract ITU-T Recommendation G.808.3 defines the generic aspects of a Shared Mesh Protection (SMP) mechanism, where the difference between SMP and Shared Mesh Restoration (SMR) is also identified. ITU-T Recommendation G.873.3 defines the protection switching operation and associated protocol for SMP at the Optical Data Unit (ODU) layer. RFC 7412 provides requirements for any mechanism that would be used to implement SMP in a Multi-Protocol Label Switching - Transport Profile (MPLS-TP) network. This document updates RFCs 4872 and 4873 to provide extensions for Generalized Multi-Protocol Label Switching (GMPLS) signaling to support the control of the SMP mechanism. Status of This Memo This is an Internet Standards Track document. This document is a product of the Internet Engineering Task Force (IETF). It represents the consensus of the IETF community. It has received public review and has been approved for publication by the Internet Engineering Steering Group (IESG). Further information on Internet Standards is available in Section 2 of RFC 7841. Information about the current status of this document, any errata, and how to provide feedback on it may be obtained at https://www.rfc-editor.org/info/rfc9270. Copyright Notice Copyright (c) 2022 IETF Trust and the persons identified as the document authors. All rights reserved. This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (https://trustee.ietf.org/license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Revised BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Revised BSD License. This document may contain material from IETF Documents or IETF Contributions published or made publicly available before November 10, 2008. The person(s) controlling the copyright in some of this material may not have granted the IETF Trust the right to allow modifications of such material outside the IETF Standards Process. Without obtaining an adequate license from the person(s) controlling the copyright in such materials, this document may not be modified outside the IETF Standards Process, and derivative works of it may not be created outside the IETF Standards Process, except to format it for publication as an RFC or to translate it into languages other than English. Table of Contents 1. Introduction 2. Conventions Used in This Document 3. SMP Definition 4. Operation of SMP with GMPLS Signaling Extensions 5. GMPLS Signaling Extensions for SMP 5.1. Identifiers 5.2. Signaling Primary LSPs 5.3. Signaling Secondary LSPs 5.4. SMP Preemption Priority 5.5. Availability of Shared Resources: The Notify Message 5.6. SMP APS Configuration 6. Updates to PROTECTION Object 6.1. New Protection Type 6.2. Updates to Definitions of Notification and Operational Bits 6.3. Preemption Priority 7. IANA Considerations 8. Security Considerations 9. References 9.1. Normative References 9.2. Informative References Acknowledgements Contributors Authors' Addresses 1. Introduction RFC 4872 [RFC4872] defines extensions for Resource Reservation Protocol - Traffic Engineering (RSVP-TE) to support Shared Mesh Restoration (SMR) mechanisms. SMR can be seen as a particular case of preplanned Label Switched Path (LSP) rerouting that reduces the recovery resource requirements by allowing multiple protecting LSPs to share common link and node resources. The recovery resources for the protecting LSPs are pre-reserved during the provisioning phase, and explicit restoration signaling is required to activate (i.e., commit resource allocation at the data plane) a specific protecting LSP that was instantiated during the provisioning phase. RFC 4873 [RFC4873] details the encoding of the last 32-bit Reserved field of the PROTECTION object defined in [RFC4872]. ITU-T Recommendation G.808.3 [G808.3] defines the generic aspects of a Shared Mesh Protection (SMP) mechanism, which are not specific to a particular network technology in terms of architecture types, preemption principle, path monitoring methods, etc. ITU-T Recommendation G.873.3 [G873.3] defines the protection switching operation and associated protocol for SMP at the Optical Data Unit (ODU) layer. RFC 7412 [RFC7412] provides requirements for any mechanism that would be used to implement SMP in a Multi-Protocol Label Switching - Transport Profile (MPLS-TP) network. SMP differs from SMR in the activation/protection switching operation. The former activates a protecting LSP via the Automatic Protection Switching (APS) protocol in the data plane when the working LSP fails, while the latter does it via control plane signaling. It is therefore necessary to distinguish SMP from SMR during provisioning so that each node involved behaves appropriately in the recovery phase when activation of a protecting LSP is done. SMP has advantages with regard to the recovery speed compared with SMR. This document updates [RFC4872] and [RFC4873] to provide extensions for Generalized Multi-Protocol Label Switching (GMPLS) signaling to support the control of the SMP mechanism. Specifically, it * defines a new LSP Protection Type, "Shared Mesh Protection", for the LSP Flags field [RFC4872] of the PROTECTION object (see Section 6.1), * updates the definitions of the Notification (N) and Operational (O) fields [RFC4872] of the PROTECTION object to take the new SMP type into account (see Section 6.2), and * updates the definition of the 16-bit Reserved field [RFC4873] of the PROTECTION object to allocate 8 bits to signal the SMP preemption priority (see Section 6.3). Only the generic aspects for signaling SMP are addressed by this document. The technology-specific aspects are expected to be addressed by other documents. RFC 8776 [RFC8776] defines a collection of common YANG data types for Traffic Engineering (TE) configuration and state capabilities. It defines several identities for LSP Protection Types. As this document introduces a new LSP Protection Type, [RFC8776] is expected to be updated to support the SMP mechanism specified in this document. [YANG-TE] defines a YANG data model for the provisioning and management of TE tunnels, LSPs, and interfaces. It includes some protection and restoration data nodes relevant to this document. Management aspects of the SMP mechanism are outside the scope of this document, and they are expected to be addressed by other documents. 2. Conventions Used in This Document The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all capitals, as shown here. In addition, the reader is assumed to be familiar with the terminology used in [RFC4872], RFC 4426 [RFC4426], and RFC 6372 [RFC6372]. 3. SMP Definition [G808.3] defines the generic aspects of an SMP mechanism. [G873.3] defines the protection switching operation and associated protocol for SMP at the ODU layer. [RFC7412] provides requirements for any mechanism that would be used to implement SMP in an MPLS-TP network. The SMP mechanism is based on precomputed protecting LSPs that are preconfigured into the network elements. Preconfiguration here means pre-reserving resources for the protecting LSPs without activating a particular protecting LSP (e.g., in circuit networks, the cross- connects in the intermediate nodes of the protecting LSP are not preestablished). Preconfiguring but not activating protecting LSPs allows link and node resources to be shared by the protecting LSPs of multiple working LSPs (which are themselves disjoint and thus unlikely to fail simultaneously). Protecting LSPs are activated in response to failures of working LSPs or operator commands by means of the APS protocol, which operates in the data plane. The APS protocol messages are exchanged along the protecting LSP. SMP is always revertive. SMP is very similar to SMR, except that activation in the case of SMR is achieved by control plane signaling during the recovery operation, while the same is done for SMP by the APS protocol in the data plane. 4. Operation of SMP with GMPLS Signaling Extensions Consider the network topology shown in Figure 1: A---B---C---D \ / E---F---G / \ H---I---J---K Figure 1: An Example of an SMP Topology The working LSPs [A,B,C,D] and [H,I,J,K] could be protected by the protecting LSPs [A,E,F,G,D] and [H,E,F,G,K], respectively. Per RFC 3209 [RFC3209], in order to achieve resource sharing during the signaling of these protecting LSPs, they have the same Tunnel Endpoint Address (as part of their SESSION object). However, these addresses are not the same in this example. Similar to SMR, this document defines a new LSP Protection Type of the secondary LSP as "Shared Mesh Protection" (see Section 6.1) to allow resource sharing along nodes E, F, and G. Examples of shared resources include the capacity of a link and the cross-connects in a node. In this case, the protecting LSPs are not merged (which is useful, since the paths diverge at G), but the resources along E, F, and G can be shared. When a failure, such as Signal Fail (SF) or Signal Degrade (SD), occurs on one of the working LSPs (say, working LSP [A,B,C,D]), the end node (say, node A) that detects the failure initiates the protection switching operation. End node A will send a protection switching request APS message (for example, SF) to its adjacent (downstream) intermediate node (say, node E) to activate the corresponding protecting LSP and will wait for a confirmation message from node E. If the protection resource is available, node E will send the confirmation APS message to the end node (node A) and forward the switching request APS message to its adjacent (downstream) node (say, node F). When the confirmation APS message is received by node A, the cross-connection on node A is established. At this time, traffic is bridged to and selected from the protecting LSP at node A. After forwarding the switching request APS message, node E will wait for a confirmation APS message from node F, which triggers node E to set up the cross-connection for the protecting LSP being activated. If the protection resource is not available (due to failure or being used by higher-priority connections), the switching will not be successful; the intermediate node (node E) MUST send a message to notify the end node (node A) (see Section 5.5). If the resource is in use by a lower-priority protecting LSP, the lower-priority service will be removed, and the intermediate node will then follow the procedure as described for the case when the protection resource is available for the higher-priority protecting LSP. If node E fails to allocate the protection resource, it MUST send a message to notify node A (see Section 5.5). Then, node A will stop bridging and selecting traffic to/from the protecting LSP and proceed with the procedure of removing the protection allocation according to the APS protocol. 5. GMPLS Signaling Extensions for SMP The following subsections detail how LSPs using SMP can be signaled in an interoperable fashion using GMPLS RSVP-TE extensions (see RFC 3473 [RFC3473]). This signaling enables: (1) the ability to identify a "secondary protecting LSP" (LSP [A,E,F,G,D] or LSP [H,E,F,G,K] from Figure 1, here called the "secondary LSP") used to recover another "primary working LSP" (LSP [A,B,C,D] or LSP [H,I,J,K] from Figure 1, here called the "protected LSP"), (2) the ability to associate the secondary LSP with the protected LSP, (3) the capability to include information about the resources used by the protected LSP while instantiating the secondary LSP, (4) the capability to instantiate several secondary LSPs efficiently during the provisioning phase, and (5) the capability to support activation of a secondary LSP via the APS protocol in the data plane if a failure occurs. 5.1. Identifiers To simplify association operations, both LSPs (i.e., the protected LSP and the secondary LSP) belong to the same session. Thus, the SESSION object MUST be the same for both LSPs. The LSP ID, however, MUST be different to distinguish between the protected LSP and the secondary LSP. A new LSP Protection Type, "Shared Mesh Protection", is defined (see Section 6.1) for the LSP Flags field of the PROTECTION object (see [RFC4872]) to set up the two LSPs. This LSP Protection Type value is only applicable to bidirectional LSPs as required in [G808.3]. 5.2. Signaling Primary LSPs The PROTECTION object (see [RFC4872]) is included in the Path message during signaling of the primary working LSPs, with the LSP Protection Type value set to "Shared Mesh Protection". Primary working LSPs are signaled by setting in the PROTECTION object the S bit to 0, the P bit to 0, and the N bit to 1; and setting in the ASSOCIATION object the Association ID to the associated secondary protecting LSP_ID. | Note: The N bit is set to indicate that the protection | switching signaling is done via the data plane. 5.3. Signaling Secondary LSPs The PROTECTION object (see [RFC4872]) is included in the Path message during signaling of the secondary protecting LSPs, with the LSP Protection Type value set to "Shared Mesh Protection". Secondary protecting LSPs are signaled by setting in the PROTECTION object the S bit, the P bit, and the N bit to 1; and setting in the ASSOCIATION object the Association ID to the associated primary working LSP_ID, which MUST be known before signaling of the secondary LSP. Moreover, the Path message used to instantiate the secondary LSP MUST include at least one PRIMARY_PATH_ROUTE object (see [RFC4872]) that further allows for recovery resource sharing at each intermediate node along the secondary path. With this setting, the resources for the secondary LSP MUST be pre- reserved but not committed at the data plane level, meaning that the internals of the switch need not be established until explicit action is taken to activate this LSP. Activation of a secondary LSP and protection switching to the activated protecting LSP is done using the APS protocol in the data plane. After protection switching completes, the protecting LSP MUST be signaled by setting the S bit to 0 and the O bit to 1 in the PROTECTION object. At this point, the link and node resources MUST be allocated for this LSP, which becomes a primary LSP (ready to carry traffic). The formerly working LSP MAY be signaled with the A bit set in the ADMIN_STATUS object (see [RFC3473]). Support for extra traffic in SMP is left for further study. Therefore, mechanisms to set up LSPs for extra traffic are outside the scope of this document. 5.4. SMP Preemption Priority The SMP preemption priority of a protecting LSP is used by the APS protocol to resolve competition for shared resources among multiple protecting LSPs and is indicated in the Preemption Priority field of the PROTECTION object in the Path message of the protecting LSP. The Setup and Holding priorities in the SESSION_ATTRIBUTE object can be used by GMPLS to control LSP preemption, but they are not used by the APS to resolve competition among multiple protecting LSPs. This avoids the need to define a complex policy for defining Setup and Holding priorities when used for both GMPLS control plane LSP preemption and SMP shared resource competition resolution. When an intermediate node on the protecting LSP receives the Path message, the priority value in the Preemption Priority field MUST be stored for that protecting LSP. When resource competition among multiple protecting LSPs occurs, the APS protocol will use their priority values to resolve this competition. A lower value has a higher priority. In SMP, a preempted LSP MUST NOT be terminated even after its resources have been deallocated. Once the working LSP and the protecting LSP are configured or preconfigured, the end node MUST keep refreshing both working and protecting LSPs, regardless of failure or preemption status. 5.5. Availability of Shared Resources: The Notify Message When a lower-priority protecting LSP is preempted, the intermediate node that performed the preemption MUST send a Notify message with error code "Notify Error" (25) (see [RFC4872]) and error sub-code "Shared resources unavailable" (17) to the end nodes of that protecting LSP. Upon receipt of this Notify message, the end node MUST stop sending and selecting traffic to/from its protecting LSP and try switching the traffic to another protecting LSP, if available. When a protecting LSP occupies the shared resources and they become unavailable, the same Notify message MUST be generated by the intermediate node to all the end nodes of the protecting LSPs that have lower SMP preemption priorities than the one that has occupied the shared resources. If the shared resources become unavailable due to a failure in the shared resources, the same Notify message MUST be generated by the intermediate node to all the end nodes of the protecting LSPs that have been configured to use the shared resources. In the case of a failure of the working LSP, these end nodes MUST avoid trying to switch traffic to these protecting LSPs that have been configured to use the shared resources and try switching the traffic to other protecting LSPs, if available. When the shared resources become available, a Notify message with error code "Notify Error" (25) and error sub-code "Shared resources available" (18) MUST be generated by the intermediate node. The recipients of this Notify message are the end nodes of the lower- priority protecting LSPs that have been preempted and/or all the end nodes of the protecting LSPs that have lower SMP preemption priorities than the one that does not need the shared resources anymore. Upon receipt of this Notify message, the end node is allowed to reinitiate the protection switching operation as described in Section 4, if it still needs the protection resource. 5.6. SMP APS Configuration SMP relies on APS protocol messages being exchanged between the nodes along the path to activate a protecting LSP. In order to allow the exchange of APS protocol messages, an APS channel has to be configured between adjacent nodes along the path of the protecting LSP. This is done by means other than GMPLS signaling, before any protecting LSP has been set up. Therefore, there are likely additional requirements for APS configuration that are outside the scope of this document. Depending on the APS protocol message format, the APS protocol may use different identifiers than GMPLS signaling to identify the protecting LSP. Since the APS protocol is left for further study per [G808.3], it can be assumed that the APS message format and identifiers are technology specific and/or vendor specific. Therefore, additional requirements for APS configuration are outside the scope of this document. 6. Updates to PROTECTION Object GMPLS extension requirements for SMP introduce several updates to the PROTECTION object (see [RFC4872]), as detailed below. 6.1. New Protection Type A new LSP Protection Type, "Shared Mesh Protection", is added in the PROTECTION object. This LSP Protection Type value is only applicable to bidirectional LSPs. LSP (Protection Type) Flags: 0x20: Shared Mesh Protection The rules defined in Section 14.2 of [RFC4872] ensure that all the nodes along an SMP LSP are SMP aware. Therefore, there are no backward-compatibility issues. 6.2. Updates to Definitions of Notification and Operational Bits The definitions of the N and O bits in Section 14.1 of [RFC4872] are replaced as follows: Notification (N): 1 bit When set to 1, this bit indicates that the control plane message exchange is only used for notification during protection switching. When set to 0 (default), it indicates that the control plane message exchanges are used for purposes of protection switching. The N bit is only applicable when the LSP Protection Type Flag is set to 0x04 (1:N Protection with Extra-Traffic), 0x08 (1+1 Unidirectional Protection), 0x10 (1+1 Bidirectional Protection), or 0x20 (Shared Mesh Protection). The N bit MUST be set to 0 in any other case. If 0x20 (SMP), the N bit MUST be set to 1. Operational (O): 1 bit When set to 1, this bit indicates that the protecting LSP is carrying traffic after protection switching. The O bit is only applicable when (1) the P bit is set to 1 and (2) the LSP Protection Type Flag is set to 0x04 (1:N Protection with Extra- Traffic), 0x08 (1+1 Unidirectional Protection), 0x10 (1+1 Bidirectional Protection), or 0x20 (Shared Mesh Protection). The O bit MUST be set to 0 in any other case. 6.3. Preemption Priority [RFC4872] reserved a 32-bit field in the PROTECTION object header. Subsequently, [RFC4873] allocated several bits from that field and left the remainder of the bits reserved. This specification further allocates the Preemption Priority field from the remaining formerly reserved bits. The 32-bit field in the PROTECTION object as defined in [RFC4872] and modified by [RFC4873] is updated by this document as follows: 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |I|R| Reserved | Seg.Flags | Reserved | Preempt Prio | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Preemption Priority (Preempt Prio): 8 bits This field indicates the SMP preemption priority of a protecting LSP, when the LSP Protection Type field indicates "Shared Mesh Protection". The SMP preemption priority value is configured at the end nodes of the protecting LSP by a network operator. A lower value has a higher priority. The decision regarding how many priority levels should be implemented in an SMP network is left to network operators. See [RFC4873] for the definitions of the other fields. 7. IANA Considerations IANA maintains a group of registries called "Resource Reservation Protocol (RSVP) Parameters", which includes the "Error Codes and Globally-Defined Error Value Sub-Codes" registry. IANA has added the following values to the "Sub-Codes - 25 Notify Error" subregistry, which lists error value sub-codes that may be used with error code 25. IANA has allocated the following error value sub-codes (Table 1) for use with this error code as described in this document. +=======+==============================+===========+ | Value | Description | Reference | +=======+==============================+===========+ | 17 | Shared resources unavailable | RFC 9270 | +-------+------------------------------+-----------+ | 18 | Shared resources available | RFC 9270 | +-------+------------------------------+-----------+ Table 1: New Error Sub-Codes 8. Security Considerations Since this document makes use of the exchange of RSVP messages that include a Notify message, the security threats discussed in [RFC4872] also apply to this document. Additionally, it may be possible to cause disruption to traffic on one protecting LSP by targeting a link used by the primary LSP of another, higher-priority LSP somewhere completely different in the network. For example, in Figure 1, assume that the preemption priority of LSP [A,E,F,G,D] is higher than that of LSP [H,E,F,G,K] and the protecting LSP [H,E,F,G,K] is being used to transport traffic. If link B-C is attacked, traffic on LSP [H,E,F,G,K] can be disrupted. For this reason, it is important not only to use security mechanisms as discussed in [RFC4872] but also to acknowledge that detailed knowledge of a network's topology, including routes and priorities of LSPs, can help an attacker better target or improve the efficacy of an attack. 9. References 9.1. Normative References [G808.3] International Telecommunication Union, "Generic protection switching - Shared mesh protection", ITU-T Recommendation G.808.3, October 2012, <https://www.itu.int/rec/T-REC-G.808.3>. [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, DOI 10.17487/RFC2119, March 1997, <https://www.rfc-editor.org/info/rfc2119>. [RFC3209] Awduche, D., Berger, L., Gan, D., Li, T., Srinivasan, V., and G. Swallow, "RSVP-TE: Extensions to RSVP for LSP Tunnels", RFC 3209, DOI 10.17487/RFC3209, December 2001, <https://www.rfc-editor.org/info/rfc3209>. [RFC3473] Berger, L., Ed., "Generalized Multi-Protocol Label Switching (GMPLS) Signaling Resource ReserVation Protocol- Traffic Engineering (RSVP-TE) Extensions", RFC 3473, DOI 10.17487/RFC3473, January 2003, <https://www.rfc-editor.org/info/rfc3473>. [RFC4426] Lang, J., Ed., Rajagopalan, B., Ed., and D. Papadimitriou, Ed., "Generalized Multi-Protocol Label Switching (GMPLS) Recovery Functional Specification", RFC 4426, DOI 10.17487/RFC4426, March 2006, <https://www.rfc-editor.org/info/rfc4426>. [RFC4872] Lang, J P., Ed., Rekhter, Y., Ed., and D. Papadimitriou, Ed., "RSVP-TE Extensions in Support of End-to-End Generalized Multi-Protocol Label Switching (GMPLS) Recovery", RFC 4872, DOI 10.17487/RFC4872, May 2007, <https://www.rfc-editor.org/info/rfc4872>. [RFC4873] Berger, L., Bryskin, I., Papadimitriou, D., and A. Farrel, "GMPLS Segment Recovery", RFC 4873, DOI 10.17487/RFC4873, May 2007, <https://www.rfc-editor.org/info/rfc4873>. [RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC 2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174, May 2017, <https://www.rfc-editor.org/info/rfc8174>. 9.2. Informative References [G873.3] International Telecommunication Union, "Optical transport network - Shared mesh protection", ITU-T Recommendation G.873.3, September 2017, <https://www.itu.int/rec/T-REC-G.873.3-201709-I/en>. [RFC6372] Sprecher, N., Ed. and A. Farrel, Ed., "MPLS Transport Profile (MPLS-TP) Survivability Framework", RFC 6372, DOI 10.17487/RFC6372, September 2011, <https://www.rfc-editor.org/info/rfc6372>. [RFC7412] Weingarten, Y., Aldrin, S., Pan, P., Ryoo, J., and G. Mirsky, "Requirements for MPLS Transport Profile (MPLS-TP) Shared Mesh Protection", RFC 7412, DOI 10.17487/RFC7412, December 2014, <https://www.rfc-editor.org/info/rfc7412>. [RFC8776] Saad, T., Gandhi, R., Liu, X., Beeram, V., and I. Bryskin, "Common YANG Data Types for Traffic Engineering", RFC 8776, DOI 10.17487/RFC8776, June 2020, <https://www.rfc-editor.org/info/rfc8776>. [YANG-TE] Saad, T., Gandhi, R., Liu, X., Beeram, V.P., Bryskin, I., and O. Gonzalez de Dios, "A YANG Data Model for Traffic Engineering Tunnels, Label Switched Paths and Interfaces", Work in Progress, Internet-Draft, draft-ietf-teas-yang-te- 30, 11 July 2022, <https://datatracker.ietf.org/doc/html/ draft-ietf-teas-yang-te-30>. Acknowledgements The authors would like to thank Adrian Farrel, Vishnu Pavan Beeram, Tom Petch, Ines Robles, John Scudder, Dale Worley, Dan Romascanu, Éric Vyncke, Roman Danyliw, Paul Wouters, Lars Eggert, Francesca Palombini, and Robert Wilton for their valuable comments and suggestions on this document. Contributors The following person contributed significantly to the content of this document and should be considered a coauthor. Yuji Tochio Fujitsu Email: tochio@fujitsu.com Authors' Addresses Jia He Huawei Technologies F3-1B, R&D Center, Huawei Industrial Base Bantian, Longgang District Shenzhen China Email: hejia@huawei.com Italo Busi Huawei Technologies Email: italo.busi@huawei.com Jeong-dong Ryoo ETRI 218 Gajeongno Yuseong-gu Daejeon 34129 South Korea Phone: +82-42-860-5384 Email: ryoo@etri.re.kr Bin Yeong Yoon ETRI Email: byyun@etri.re.kr Peter Park KT Email: peter.park@kt.com