💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0700.tb captured on 2023-12-28 at 22:29:38.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0700A 08-16-91 ============================================================================= PREMIUM 386SX/16 AND COLORADO 120MB TAPE DRIVE PROBLEM: When a Wang emulation board is installed in a Premium 386SX/16 and connected to a Wang computer, the Colorado 120MB tape drive revision FW63 fails to initialize. AFFECTED SYSTEM: AST Premium 386SX/16 with the following system board part number: 202360-001 CAUSE: Incompatibility between Colorado 120MB tape drive, revision FW63 and AST's Premium 386SX/16 and the Wang emulation board. SOLUTION: This is not an issue that AST can resolve. The Colorado 120MB tape drive, revision FW40 does operate correctly. Customers experiencing this problem should contact Colorado's Technical Support for more information.