AST RESEARCH, INC. TECHNICAL BULLETIN #TB-0335 11/18/87 AST-COAX SERIES/API OPTION This Technical Bulletin is provided in order to supplement the documentation regarding the write direct to buffer (function 19) and the cursor positioning (function 18) functions. Write direct to buffer documentation states that the cursor position must be initialized by a "Set cursor position for direct buffer write (function 18.)" To work properly, the cursor position (function 18) must be initialized at the beginning of the nanoprocessor display buffer. Initializing cursor position at the end of the buffer display causes the buffer to appear empty. The call made is: ENTRY: AX 18 DX Cursor Position The cursor positions 0 through 79 correspond to the status line (operator information area). Position 80 corresponds to the upper left corner of the display screen.