💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0246.tb captured on 2023-12-28 at 22:21:05.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0246 11/19/86 AST-3G PLUS/MEMORY ERROR MESSAGE A problem has been discovered when using AST-3G Plus emulation when the board is installed in IBM Model 339 AT or compatible PC's. This problem could occur in either "CGA" or "HERCULES/PREVIEW" emulation modes. The problem occurs when the PC is warm booted. On a cold boot the problem does not occur. Depending on the type of machine, either the message "CONFIGURATION TOO LARGE FOR MEMORY" or "PARITY CHECK TWO" will appear after a warm boot. The PC will "lock" and will have to be powered down. To prevent this from occuring, AST-3G diagnostics diskette version 2.26 is required. After cold booting the machine, run the program "EMUL ON", which is contained on the diagnostics diskette. This will load a keyboard intercept routine, which will prevent the memory error from occuring after a warm boot. This program must be run every time the machine is powered on to prevent the recurrence of the problem.