💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0151a.tb captured on 2023-12-28 at 22:18:23.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0151A 04-11-86 AST COMMUNICATION BOARDS WITH THE IBM AT AND COMPATIBLES AST communication boards use IRQ2 as a factory default interrupt setting. The IBM AT, the COMPAQ 286, and the COMPAQ DESKPRO 286 have two interrupt controller chips: 8259's. IRQ2 is on Interrupt Controller, CTLR2, and is a cascading interrupt. A cascading interrupt has to travel a longer route before it is serviced. Because of this, there may be differences in timing between a cascading and non-cascading interrupt. Problems may occur if the interrupt takes a longer time to be serviced than the communication software expects. For this reason, AST suggests that the AST board is set for an unused non-cascading interrupt. The following AST communication packages use IRQ2: AST-5251/11, AST-5251/12, AST-3780, AST-3770, AST-BSC, AST-BSC CLUSTER, AST- BSC GATEWAY, AST-SNA, AST-SNA CLUSTER, and AST-SNA GATEWAY.