AST RESEARCH TECHNICAL BULLETIN TB-0137 12-20-85 AST 5251/11 EMULATION SOFTWARE VERSION 2.0 AND THE KERNEL COMMAND When using AST-5251/11 Emulation Software Version 2.0, the manual describes that when issuing the KERNEL command, information about reading switches is displayed. The software does not read the switch settings off the twinax adapter board, when issuing the standard "KERNEL" command. The only way to get information about the switches displayed, is to enter an optional command-line parameter, when issuing the "KERNEL" command. (e.g. KERNEL /IRQ=n). However, it is suggested that when making changes in the configuration, the changes are made in the configuration file only, not on the command-line. The reason for this suggestion is that changes made in the configuration file will not be enabled because the software will not read the configuration file upon issuance of KERNEL.