💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0345.tb captured on 2023-11-14 at 13:36:26.

View Raw

More Information

⬅️ Previous capture (2023-06-16)

-=-=-=-=-=-=-




AST RESEARCH, INC. TECHNICAL BULLETIN #TB-0345        11/19/87

                 AST-5250/CLUSTER INSTALLATION


This technical bulletin is written as a guide for installation
of the AST-5250/Cluster.


 I. THINGS TO CHECK BEFORE RUNNING CLUSTER EMULATION

    A. On the master cluster bring up emulation for all the
       sessions that will be used for the cluster.  This can be
       done by defining the sessions as Non-CLUSTER, under
       STATION in the CFG5251 program, and running KERNEL and
       APS without CLU5251.  This will verify that those
       sessions are available and correctly configured on the
       host.

    B. Correctly install the Cluster Adapter Board.  Ensure the
       hardware settings (IRQ, I/O address) do not conflict
       with other devices in the computer.

       1. Switch Bank 1 (SW1) and Switch Bank 2 (SW2), the IRQ
          switch settings, must be set to use a unique IRQ.

       2. Switch Bank 3 (SW3) settings.  SW3 3 must be on and
          SW3 4 must be off.  Settings for SW3 1 and SW3 2
          depend on the type of computer used:

          a. If a PC, PC compatible, AT or AT compatible
             (80286) is used:

             - Set SW3 1 off and 2 on for I/O address 2BF.
             - Set SW3 1 off and 2 off for I/O address 1BF.

          b. If an XT or XT compatible computer is used:

             - Set SW3 1 off and 2 off for I/O address 1BF.

II. SETTING UP THE CLUSTER

    A. Master Cluster:  CFG5251 program configuration
       1. Type CFG5251.
       2. Answer YES to Master Cluster question.
   3. Go into STATION.

      a. Define sessions to be used by the master as DISPLAYs
         or PRINTERs under the STATION option.
      b. Define sessions to be distributed to slaves as
         CLUSTER DISPLAYs or CLUSTER PRINTERs.

      Give unique SESSION NAMEs for each CLUSTER session that
      will be distributed.  Make a note of these names and
      their corresponding sessions numbers.

   4. Go into CLUSTER

      a. Enter the IRQ and I/O Address of the Cluster board
         under their appropriate options - INTERRUPT and
         I/O_ADR respectively.
      b. Configure each individual port.  These must be set
         for all ports being used (maximum of 4 ports).

      c. COMPORT configurations.  These settings depend on
         how the slave device is set.  The most common
         settings are:

            BAUD=9600 for COM LINE=DEDICATED, or
            BAUD=(speed of modem) for COM LINE=DIALUP,

            DATA=8
            STOP=1
            PARITY=NONE
            REMOTE DEVICE=device type of slave, either PC,
             ASCII24 or ASCII25 (ASCII refers to "dumb-
             terminals").
            COM LINE=DIALUP for slaves using modems to
             communicate to master.
            COM LINE=DEDICATED for slaves using RS-232C
             cables to communicate to master (must be null-
             modem cables, as specified in the AST-5250/
             Cluster User's Manual (part number 000428-001,
             section A.3, page A-6).

         The following applies only if REMOTE DEVICE=ASCII24
         or ASCII25:

            XON/XOFF=XON/XOFF setting of ASCII terminal
            SESSION NAME=NONE

      d. DIRECTORY settings.  Enter a directory NAME for each
         slave that will be using this session and port.  For
         example enter Alf for the NAME of directory listing
         0.  Alf must also be entered in the slave for
         directory listing 0 if it will be using this session
         and is attached to this port.  Up to 19 directory
         listings may be defined.
      e. INITIALIZE option.  If a modem will be used to
         remotely dial into this master cluster, an
         initialization string must be entered here.

                    Modem                     String
           Hayes compatible 1200 baud     ATE0Q0S0=1
           Hayes compatible 2400 baud     ATE0Q0S0=1&C1&D2
           Microcom compatible            ATE0Q0S0=1&C1&D2\J0

         The purpose of this string is to set the modem into
         autoanswer mode, inhibit command echo, enable result
         codes back to the terminal, and set the modem to be
         in direct mode with a set baud rate speed.

      f. The EBCIDIC, ASCII, and TERMINAL options do not have
         to be changed.

   5. SAVE configurations and QUIT.
   6. In DOS type KERNEL, CLU5251 and then APS.  These
      commands could also be put in a batch file.

B. Slave Cluster:  CFG5251S program configuration

   1. Type CFG5251S.
   2. Answer NO to all initial questions.
   3. Go into HARDWARE.

      a. COMPORT configurations.  All settings in this
         selection: BAUD, DATA, STOP, PARITY, COM_PORT,
         DEVICE, and COMLINE must be the same as the master
         configurations for this particular port.
      b. DIRECTORY configurations.  Each directory NAME must
         match the name on the master directory.  For
         example, if Alf was entered for the NAME of
         directory listing 0 on the master then Alf must also
         be entered for directory listing 0 on this slave.
         If slave will be a DIALUP device (remote emulation,
         using modems) the PHONE NUMBER of the master must
         also be entered, remember to start the number with
         the ATDT dial command.
      c. INITIALIZE option.  If a modem will be used to
         remotely dial into the master cluster, an
         initialization string must be entered here.

                    Modem                     String
           Hayes compatible 1200 baud     ATE0Q0S0=1
           Hayes compatible 2400 baud     ATE0Q0S0=1&C1&D2
           Microcom compatible            ATE0Q0S0=1&C1&D2\J0

         The purpose of this string is to set the modem into
         autoanswer mode, inhibit command echo, enable result
         codes back to the terminal, and set the modem to be
         in direct mode with a set baud rate speed.
   4. Go into the STATION option.

      a. Define all sessions to be used by this slave PC as
         DISPLAYs or PRINTERs.

      Ensure the session numbers and corresponding SESSION
      NAMEs match the master cluster definitions, the name is
      case dependent.

   5. SAVE configurations and QUIT.
   6. In DOS type KERNELSL and then APS.  These commands
      could also be put in a batch file.