💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0344.tb captured on 2023-11-14 at 13:36:25.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH, INC. TECHNICAL BULLETIN #TB-0344 11/19/87 AST-5250/ASYNC DIALUP INSTALLATION This technical bulletin is written as a guide for installation of the AST-5250/Async Dialup. I. THINGS TO CHECK BEFORE RUNNING CLUSTER EMULATION A. On the master async dialup, bring up emulation for the session that will be used by the slave. This can be done by defining the sessions under STATION in the CFG5251 program as a regular DISPLAY (not CLUSTER DISPLAY) and running KERNEL and APS without ACLU5251. This will verify that the session is available and correctly configured on the host. II. SETTING UP THE ASYNC DIALUP A. Master Async Dialup: CFG5251 program configuration 1. Type CFG5251. 2. Answer YES to Master Async Dialup question. 3. Go into STATION. a. Define sessions to be used by the master as DISPLAYs or PRINTERs under the STATION option. b. Define sessions to be distributed to slaves as CLUSTER Give unique SESSION NAMEs for each CLUSTER session that will be distributed. Make a note of these names and their corresponding sessions numbers. 4. Go into CLUSTER: Configure async dialup interface. a. COMPORT configurations. These settings depend on how the slave device is set. The most common settings are: BAUD=9600 for COM LINE=DEDICATED, or BAUD=(speed of modem) for COM LINE=DIALUP DATA=8 STOP=1 PARITY=NONE REMOTE DEVICE=device type of slave, either PC, ASCII24 or ASCII25 (ASCII refers to "dumb- terminals"). COM LINE=DIALUP for slaves using modems to communicate to master. COM LINE=DEDICATED for slaves using RS-232C cables to communicate to master (must be null- modem cables). The following only applies if REMOTE DEVICE=ASCII24 or ASCII25: XON/XOFF=XON/XOFF setting of ASCII terminal SESSION NAME=NONE b. DIRECTORY settings. Enter a directory NAME for each slave that will be using this session and port. For example enter Alf for the NAME of directory listing 0. Alf must also be entered in the slave for directory listing 0 if it will be using this session and is attached to this port. Up to 19 directory listings may be defined. c. INITIALIZE option. If a modem will be used to remotely dial into this master async dialup, an initialization string must be entered here. Modem String Hayes compatible 1200 baud ATE0Q0S0=1 Hayes compatible 2400 baud ATE0Q0S0=1&C1&D2 Microcom compatible ATE0Q0S0=1&C1&D2\J0 The purpose of this string is to set the modem into auto-answer mode, inhibit command echo, enable result codes back to the terminal, and set the modem to be in direct mode with a set baud rate speed. d. The EBCIDIC, ASCII, and TERMINAL options do not have to be changed. 5. SAVE configurations and QUIT. 6. In DOS type KERNEL, ACLU5251 and then APS. These commands could also be put in a batch file. B. Slave Async Dialup: CFG5251S program configuration 1. Type CFG5251S. 2. Answer NO to all initial questions. 3. Go into HARDWARE. a. COMPORT configurations. All settings in this selection: BAUD, DATA, STOP, PARITY, COM_PORT, DEVICE, and COMLINE must be the same as the master configurations for this particular port. b. DIRECTORY configurations. Each directory NAME must match the name on the master directory. For example, if Alf was entered for the NAME of directory listing 0 on the master then Alf must also be entered for directory listing 0 on this slave. If slave will be a DIALUP device (remote emulation, using modems) the PHONE NUMBER of the master must also be entered, remember to start the number with the ATDT dial command. c. INITIALIZE option. If a modem will be used to remotely dial into the master cluster, an initialization string must be entered here. Modem String Hayes compatible 1200 baud ATE0Q0S0=1 Hayes compatible 2400 baud ATE0Q0S0=1&C1&D2 Microcom compatible ATE0Q0S0=1&C1&D2\J0 The purpose of this string is to set the modem into autoanswer mode, inhibit command echo, enable result codes back to the terminal, and set the modem to be in direct mode with a set baud rate speed. 4. Go into the STATION option. a. Define all sessions to be used by this slave PC as DISPLAYs or PRINTERs. Ensure the session numbers and corresponding SESSION NAMEs match the master cluster definitions, the name is case dependent. 5. SAVE configurations and QUIT. 6. In DOS type KERNELSL and then APS. These commands could also be put in a batch file.