💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0251.tb captured on 2023-11-14 at 13:34:47.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0251 12/18/86 SPERRY IT AND DESQVIEW To make the Sperry DESQview/EEMS compatible, the following steps need to be executed: 1. Set the IT motherboard for the "B" option (switches 3 & 5 on). 2. Then set the AST EEMS board to start at 256K (SW2 - everything on except for SW #6) and use 384K to backfill.* 3. Run "IT-SETUP", out of Diagnostics, and select option "1". The two choices are "0" or "1" and, in this case, use option "1". 4. Next, set "expansion" to "0.5" (not .5, but 0.5). 5. Install REMM.SYS from SuperPak 6.10 (or later) in the CONFIG.SYS file, and DESQview 1.11 should run. For further information, the customer should refer to page three of Chapter seven of the "IT" User Manual.