💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0247.tb captured on 2023-11-14 at 13:34:42.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0247 12-10-86 SPERRY IT I/O PORT SELECTION FOR THE TURBOLASER Due to a slight incompatibility problem concerning the way the SPERRY IT configures its Serial and Parallel ports, a user must patch system memory for correct operation with the TURBOLASER printer. During a power on sequence, or a reboot of the computer, DOS examines the I/O port addresses to determine what Serial and Parallel ports are installed. DOS stores these addresses in memory locations as follows: SEGMENT:OFFSET I/O PORT ADDRESS 40:00/01 COM1 03F8 40:02/03 COM2 02F8 40:08/09 LPT1 03BC 40:0A/0B LPT2 0378 40:0C/0D LPT3 0278 TABLE 1: PORT ASSIGNMENT Assuming that all five ports are installed, memory locations would appear as follows if "DEBUG" DISPLAY (D) were used: DEBUG D40:00 F8 03 F8 02 00 00 00 00 -BC 03 78 03 78 02 00 00 (COM1) (COM2) (LPT1) (LPT2) (LPT3) (The address bytes are stored in reverse order.) NOTE: On the SPERRY IT, these locations show all zeros and will inhibit correct TURBOLASER operation. When selecting printer ports, the user must know: 1. What ports are installed and their I/O address. 2. That no two devices can use the same I/O address. 3. That DOS assigns both COM1 and LPT1 the hightest hexadecimal address it finds during the boot process. This can be very confusing. A. An example of the above procedure would assign Port address 02F8 (normally COM2) as COM1 if Port address 03F8 was not also installed in the system. B. Another example would be if the only Parallel Port in the system has a I/O Port address of 0278 (normally LPT3). DOS would assign this port LPT1. C. Memory Location 40:00 through 40:0F would appear as: F8 02 00 00 00 00 00 00-78 02 00 00 00 00 00 00 4. Most Multifunction "add-on" boards use I/O address 0378 as LPT1. This automatically bumps to LPT2 if another board, such as the IBM Monochrome adapter using address 03BC, is installed. 5. The AST TURBOLASER port selection jumpers select the I/O Port addresses as shown in Table 1. 6. There cannot be a COM2 Printer Port without a COM1. 7. There cannot be a LPT2 without a LPT1, nor a LPT3 without having both a LPT1 and LPT2. PROCEDURE TO PATCH MEMORY 1. Use EDLIN, or any other line editor, to create the two files listed below: PATCH (File Name) F 40:00 L2 F8 03 *if TurboLaser is COM1 F 40:02 L2 F8 02 *if TurboLaser is COM2 F 40:08 L2 BC 03 *if TurboLaser is LPT1 F 40:0A L2 78 03 *if TurboLaser is LPT2 F 40:0C L2 78 02 *if TurboLaser is LPT3 Q (Quit) Note: Choose only one or two of the above ports according to the TURBOLASER jumper selections. SETPORT.BAT (File Name) DEBUG < PATCH *MODE COMn:9600,,,,P *MODE LPTn:=COMn *MODE LPTn:,,P *CD\ASTLP *LPLOAD PORTn ASTLASER.LNG *LPLOAD PORTn FBEGIN font font FEND or *EPSONI * Indicates optional entries depending on configuration and user application. 2. The SETPORT.BAT file should be the last entry in the AUTOEXEC.BAT file if automatic execution is desired. 3. The above two files should reside in the "ROOT" directory of the Boot disk, or a correct path should be specified.