💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0210a.tb captured on 2023-11-14 at 13:34:07.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0210A 09/19/86 AST3270/FTS-C / TELEX 3274 CONTROLLERS The purpose of this Technical Bulletin is to help the user of AST3270/FTS-C resolve a "nanoprocessor error" when connected to a Telex controller. Utilizing AST3270/FTS-C Version 1.15 with the standard ASTPCOX and AST3270 COAX, 1A board, a problem can occur connected to a Telex 3274 controller. When FTS-C is executed, it will report a "nanoprocessor error" and abort to DOS. This happens due to an incompatibility between the 1A board and Telex controllers. To resolve the conflict, an exchange of boards will be required. The board which will operate in this environment is the 1B board available in the AST3270 COAX / with IRMA product, and the ASTPCOX / with IRMA product. Call Technical Support to obtain a Return Authorization Number for the exchange of the board. This is a no cost exchange and the user will have all the functions of the standard AST3270 products along with additional features.