💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0166.tb captured on 2023-11-14 at 13:33:23.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0166 4-24-86 I/O MINI E9/E10 JUMPERS There has been a change to the positioning of the E9 and E10 jumper blocks on the revision E (202039E) I/O Mini board. The current I/O Mini User's Manual, part number 000173-001 B, does not reflect the change in positioning. Pages 5-4 and 6-5 incorrectly position E9 and E10. The correct positioning of these jumpers are: ----- ----- | | | | | o | | o | | | | | | o | | o | | | | | ----- ----- E9 E10 E9 controls IRQ 3 for serial port #2 (see page 5-4). E10 controls IRQ 7 for the parallel printer port (see page 6-5). This information only applies to revision E I/O Mini boards. The manual correctly positions these jumper blocks for I/O Mini revision A thru D.