💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0084.tb captured on 2023-11-14 at 13:32:36.
⬅️ Previous capture (2023-06-16)
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0084 5-3-85 MGO 123/PREVU AND MAX 12E Our customer base has reported that the Princeton Graphic MAX 12E monitor does not function properly with the AST MonoGraphPlus or Preview! The symptom reported is that when high intensity is selected, the monitor displays reverse video with no characters legible. This symptom was reported using the display test in IBM diagnostics or when using Turbo Pascal. According to Princeton Graphic, Technical Support, the incompatibility exists with AST as well as other manufacturers. The short-term solution, according to Princeton Graphic, is to remove D201. D201 is located on the main board next to the input signal connector in the MAX 12E. Princeton Graphic did not indicate what their long-term solution is but serial number ky23501 through kw15861 will not have D201 installed. AST recommends that Princeton Graphic be contacted for confirmation and instructions of modification.