💾 Archived View for spam.works › mirrors › textfiles › hacking › primecpl.hac captured on 2023-11-14 at 09:56:53.

View Raw

More Information

⬅️ Previous capture (2023-06-14)

-=-=-=-=-=-=-

_______________________________________________________________________________ 
 
 
                  An Introduction to PRIMOS CPL Directives 
                         Written by Necrovore
 
                 A Telecom Computer Security Bulletin File 
_______________________________________________________________________________ 
 
 
 
PREFACE 
 
This text file is intended to serve as a reference guide for the aspiring CPL 
programmer.  It is a full listing of CPL commands and discusses all arguments 
rather thoroughly.  The following directives may be used within CPL programs 
only (for information on writing CPL programs, see the CPL User's Guide). 
 
This file was to be released in Phrack Issue 20 but certain members of that 
organization decided that this information was "too valuable for release to the
general public".  You know what I think of that?  Utter bullshit.  Sounds more 
like a bad case of information hoarding to me.  That is not very cool.  They 
appear to be afraid that Primes will be abused by people.  Tell me, is it not 
better to teach everyone what CPL is and what it can do and how to PROPERLY use
it?  Thus, this file is not being released in Phrack.  It is being released as 
part of TCSB Volume One. 
 
 
CPL COMMANDS 
 
&ARGS [name[;[type][=default] ]...]~ 
[name: -control_list [name[;[type][=default] ];...] ] 
 
Defines names (plus types, default values, and keywords, if desired) for arg- 
uments to be passed to a CPL program.  Type may be any type shown below.  If 
type is not specified the argument defaults to type char.  If default is not 
specified, the system defaults are assigned as shown below: 
 
     Argument                                         CPL 
       Type              Explanation             Default Value 
 
     CHAR          Any character string up to          " 
                   1024 characters long, mapped 
                   to upper case (default). 
     CHARL         Any character string up to          " 
                   1024 characters long, no 
                   case shifting. 
     TREE          A filename, directory name,         " 
                   or pathname, up to 128 char- 
                   acters long.  The last element 
                   of the pathname (that is, the 
                   final file or directory name) 
                   may contain wildcard characters. 
     ENTRY         A filename up 32 characters         " 
                   long; may contain wildcard
                   characters. 
     DEC           A decimal integer (A).              0 
     OCT           An octal integer (A).               0 
     HEX           A hexadecimal integer (A).          0 
     PTR           Pointer; a virtual address        7777/0 
                   in the format "octal/octal" 
                   (segno/wordno) (B). 
     DATE          Calendar date in the format         " 
                   mm/dd/yy.hh:mm:ss or yy-mm- 
                   dd.hh:mm:ss.                        " 
     REST          The remainder of the command 
                   line. 
     UNCL          All tokens not accounted for        " 
                   in the &ARGS picture. 
 
     (A)  Numeric arguments must be within the range if -2**31+1...2**331-1 
     (B)  User specified default values are not supported for this datatype. 
 
 
&CALL routine_name 
 
Transfers control of the internal routine designated by routine_name.  See also
&ROUTINE. 
 
 
&CHECK expression &ROUTINE routine_name 
 
Defines an error condition (expression) and a routine (routine_name) to handle 
the condition.  When this directive is present, the CPL interpreter evaluates 
expression after executing each PRIMOS command.  If expression is true, control
passes to routine_name. 
 
 
&DATA statement 
 statement1 
    . 
    . 
    . 
 statement-n 
[&TTY] 
&END 
 
Groups of statements to be treated as data or subcommands for user programs or 
PRIMOS utilities.  The statement immediately following &DATA must invoke the 
program or utility.  All other statements between &DATA and &END are evaluated,
and the results written into a temporary file.  The program (or utility) is 
then invoked and information passed to it, a line at a time, when called for. 
 
The &TTY directive may be used as the last statement preceding the &END.  When 
it is reached, control passes to the user at the terminal.  When the user exits
from the program or utility, control returns to the CPL program. 
 
 
&DEBUG [option-list]
 
Enables debugging for the CPL procedure containing the &DEBUG directive.  If 
given without options, &DEBUG is equivalent to &DEBUG NO_EXECUTE &ECGI ALL. 
Options are: 
 
         OPTION                      ACTION 
 
     &OFF                            Turns off all debugging options. 
                                     Initially all options are off. 
     &NO_EXECUTE, &NEX               Suppresses execution of PRIMOS 
                                     commands, but interprets CPL 
                                     directives. 
     &EXECUTE, &EX                   Enables execution of PRIMOS 
                                     commands. 
           {ALL}                     If ALL is specified, echoes PRIMOS 
     &ECHO {COM}                     commands and CPL directives.  If COM 
           {DIR}                     is specified, echoes only PRIMOS 
                                     commands.  If DIR is specified, 
                                     echoes CPL directives.  Default is ALL. 
              {ALL}                  ALL cansels all echoing.  COM cancels 
     &NO_ECHO {COM}                  echoing of PRIMOS commands.  DIR 
              {DIR}                  cancels echoing of CPL directives. 
                                     Default is ALL. 
     &WATCH                          Adds the specified variables to the 
     [var1 var2 ... var16]           watchlist  When the value of a 
                                     watched variable is changed using 
                                     the &SET_VAR directive (not the &SET_ 
                                     VAR command), CPL reports this fact 
                                     and the new value of the variable. 
                                     At most 16 variables can be on the 
                                     watchlist.  If no vari are present, 
                                     all variables are watched. 
     &NO_WATCH                       Removes the specified variable(s) 
     [var1 var2 ... var16]           from the watchlist.  If no variables 
                                     are specified, watching is turned 
                                     off completely. 
 
 
&DO [iteration] 
 statement-1 
    . 
    . 
    . 
 statement-n 
&END 
 
Allows a group of statements to be used anywhere a single statement can be 
used.  If iteration is present, allows conditionally repeated execution of the 
statements contained between the &DO and the &END, iteration may be any of: 
 
     1.  null (statement grouping) 
     2.  [&WHILE while] [&UNTIL until] 
     3.  var := start [&TO to] [&BY by] 
            [&WHILE while] [&UNTIL until]
     4.  var &LIST list [&WHILE while] [&UNTIL until] 
     5.  var &ITEMS items [&WHILE while]  [&UNTIL until] 
     6.  car := start &REPEAT repeat~ 
            [&WHILE while] [&UNTIL until] 
 
 
&EXPAND {ON} 
        {OFF} 
 
Turns abbreviation expansion on or off.  Default is OFF. 
 
 
&GOTO label_name 
 
Transfers control to the statement following the &LABEL label_name directive. 
 
 
&IF expression &THEN true-statement 
[&ELSE false-statement] 
 
Evaluates expression.  If expression is true, true-statement is executed.  If 
expression is false, then: 
 
     o  If &ELSE is present, false-statement is executed. 
     o  If &ELSE is not present, control passes to the next 
        statement in the CPL program. 
 
 
&LABEL label_name 
 stateent 
 
Defines a label, label_name to which a &GOTO can go.  (When &GOTO is reached, 
control passes to the statement following the &LABEL directive) 
 
 
&ON condition &ROUTINE routine_label 
 
Defines an internal routine to act as condition-handler (or on-unit) for the 
defined condition.  (See the PRIMOS Subroutines Reference Guide for a list of 
PRIMOS-defined conditions and an explanation of PRIMOS's Condition Mechanism) 
 
 
&RESULT expression 
 
Used only in CPL programs designed to invoke via function calls from other CPL 
programs.  (For example, "&IF A<50 &THEN &S B := [R program]"). 
 
When the &RESULT directive is reached, expression is evaluated and its value 
returned as the result of the function call. 
 
 
&RETURN [severity] [&MESSAGE text] 
 
Halts execution of procedure in which it occurs.  Returns control to procedures
called. 
 
If &MESSAGE is present, prints text on terminal when control returns.  If sev- 
erity is present returns its value as a severity code to the procedures caller.
Severity must be an integer. 
 
 
&REVERT condition 
 
Disables the latest condition handler defibed (via the &ON directive) for the 
named condition. 
 
 
&ROUTINE routine_name 
 
Names and defines entry point for an internal routine. 
 
 
&SELECT test_expression 
 &WHEN expression-1 [,expression-2, ... ,expression-n] 
 statement
 &WHEN expression-1 [,expression-2, ... ,expression-n] 
 statement 
    . 
    . 
    . 
 [&OTHERWISE statement] 
&END 
 
Test_expression is evaluated and tested against expression-1, expression-2, and
in turn until expression-n is reached.  When a match for test_expression is 
found, the statement following the matching expression is executed. 
 
If no match is found, then: 
 
     o  If an &OTHERWISE directive is present, the statement following 
        it is executed. 
     o  If no &OTHERWISE directive is present, control passes to the 
        statement following the &END of the &SELECT group. 
 
 
&SET_VAR var-1 [, var-2, ... , var-n] := value 
 
Sets the value of the named variables to value.  The variables need not exist 
previously.  May be abbreviated to &S. 
 
 
&SEVERITY [level] [action] 
 
Checks for severity codes other than 0 (where codes > 0 indicate errors and 
codes < 0 indicate warnings) after execution of each PRIMOS command.  If a code
>= level is found, takes the specified action. 
 
     Level may be:
 
        &ERROR                  Ignore warnings, take action on errors. 
        &WARNING                Take action on warnings and errors both. 
 
     Action may be: 
 
        &FAIL                   Halt execution, return a positive severity 
                                code to the routine's caller. 
        &IGNORE                 Continue execution. 
        &ROUTINE routine_name   Pass control to the designated routine. 
 
If neither level nor action is given, all severity codes are ignored.  If no 
&SEVERITY directive is given, warnings are ignored and errors halt execution. 
 
 
&SIGNAL condition [&NO_RETURN] 
 
Raises the condition "condition" and causes the CPL mechanism to search for a 
handler for that condition.  If &NO_RETURN is specified, execution of the 
error-causing procedure cannot be resumed. 
 
 
&STOP [severity] [&MESSAGE text] 
 
Halts execution of procedure in which it occurs.  If this procedure is a rout- 
ine, &STOP also halts the execution of the program containing the routine and 
any of the other routines that program may have active.  Control returns to the
caller of the mail program. 
 
If severity is present, specified severity code is returned to program's 
caller.  Severity must be an integer.  If &MESSAGE is present, text is printed 
at the caller's terminal. 

Downloaded From P-80 Systems 304-744-2253