DMA Techniques for Personal Computer Data Acquisition

Introduction

Data  acquisition generally involves sampling some set  of  "real 
world"  signals  at a regular rate, and storing the  results  for 
processing and display. Enhanced with data acquisition  hardware, 
a  personal  computer is an excellent vehicle for  this  sort  of 
activity. It can contain all the elements of the data acquisition 
system--system  control,  data storage,  data  manipulation,  and 
report  generation--at  low  cost. The  ubiquitous  IBM  PC  (and 
compatibles)  is an excellent choice because of the  richness  of 
hardware and software enhancement products available for it.

There are three basic techniques available for accomplishing  the 
sampling  task -- polling, interrupts, and DMA, or Direct  Memory 
Access.  While  the main thrust of this discussion  is  DMA,  the 
other two techniques deserve mention.

Using   the  polling  technique,  the  data  acquisition   system 
generates  a  clock pulse to signal the computer  to  sample  the 
data.  The  clock can either be a stable, regular  pulse  from  a 
crystal  oscillator,  or  it can be generated  by  some  external 
event.  The  computer's  program is in a loop  waiting  for  this 
clock.  At each occurrence, it samples and stores the data.  This 
technique  has the advantage of being very simple  to  implement, 
and quite fast (up to 200,000 12-bit samples/sec in a '386  based 
machine  using  assembly  language). The  major  disadvantage  of 
polling   is  that  it  monopolizes  the  computer  during   data 
acquisition.  Even the PC's keyboard and clock interrupts must be 
disabled to avoid missing data samples.

Interrupt-driven  data  acquisition also requires  some  sort  of 
clock signal to indicate when it is time to sample and store  the 
data.  In  this  case, however, the  clock  signal  generates  an 
interrupt  to the PC, and the interrupt handling routine  samples 
and  stores  the  data. The computer is not  in  a  program  loop 
waiting  for the clock. This overcomes the major disadvantage  of 
polling  -- the computer is free for other tasks as well as  data 
acquisition.  Each time the processor receives an  interrupt,  it 
has  to  save the contents of all its registers, so that  it  can 
pick  up  where  it left off when  it  returns.  This  additional 
overhead makes interrupts much slower than polling (around  10000 
12-bit samples/sec in a similar machine). An interrupt routine is 
also  much more difficult to implement in software.  Finally,  in 
order  to maintain a gap-free regular data acquisition  rate,  it 
may  still  be necessary to disable the PC's clock  and  keyboard 
interrupts. 

The  third  data acquisition technique is Direct  Memory  Access. 
Using this technique, the data acquisition hardware sends data to 
( or receives data from) the computer's memory directly. DMA also 
uses  a  clock  signal as do the other two  techniques.  In  both 
polling and interrupt driven data acquisition, however, the  data 
is  retrieved  from the hardware and transferred into  memory  by 
computer  instructions in the user's program. DMA is a method  by 
which the hardware takes control of the computer's data, address, 
and  control busses, and interacts with memory  directly  without 
processor  intervention (See Fig. 1). Each time the sample  clock 
"ticks", data is directly inserted into memory.

Since  it proceeds without software intervention, DMA is  also  a 
fast  method of acquiring data -- speeds of up to 180,000  12-bit 
samples  per second can be achieved on a PC/XT. It also  has  the 
advantage  of  operating  as a true background  task.  Since  the 
user's  program  does  not  have to deal  with  the  business  of 
acquiring  each  sample, it is free to perform other  tasks.  The 
computer's keyboard and timer interrupts can remain active  since 
they will not affect DMA operation.

DMA in Data Acquisition

Personal   computers   were  originally  designed   to   increase 
productivity in office automation applications.  Among the  first 
software  products to appear were word processors,  spreadsheets, 
and  database managers. The fundamental difference between  these 
sorts of applications and Data Acquisition is the extent to which 
they  must react to the "real world." 

Office  automation  software  responds to  inputs  from  a  human 
operator  --  generally keystrokes. The  potential  frequency  of 
these inputs is very low compared to the processing speed of  the 
computer,  even for the fastest typist in the world. This is  not 
the case in Data Acquisition.

Consider a system capturing an audio frequency input from an  A/D 
converter. To achieve a bandwidth of 20 KHz, such a system  would 
need to sample the input at 40,000 samples/sec, or once every  25 
microseconds.  If the input is sampled at a frequency lower  than 
twice the signal frequency, "aliasing" errors will occur. In this 
case,   higher  frequency  components  of  the   input   waveform 
"masquerade"  as lower frequency components, causing  potentially 
significant errors in signal re-construction. 

A good typist may enter 5 to 8 characters per second through  the 
keyboard  --  three orders of magnitude in frequency  below  what 
would   be  required  of  the  data  acquisition   system.   Data 
Acquisition, then, is very much a "real time" activity, and speed 
of  response is a critical concern. DMA is a good way to  provide 
this  speed  without seriously taxing the computer's  ability  to 
perform other tasks.

It  is not enough, however, to acquire a signal very quickly.  In 
order  to  accurately reconstruct a waveform, one must  know  not 
only the value of a signal, but also the time at which the signal 
was sampled. The simplest way to know the time at which a  sample 
was taken is to take all the samples at a regular rate. The  time 
of  any  given sample can then be computed by knowing  the  exact 
time between samples.

This method of sampling depends heavily on the sample rate  being 
extremely  regular.  Variations in  sample-to-sample  timing,  or 
"jitter",  can lead to significant errors. Consider a 1 KHz  sine 
wave at 20 V peak-to-peak being sampled by a 12-bit A/D converter 
with  a timing uncertainty of only 1 usec. At worst case  (around 
0V  where  the rate of change of the sine wave is  highest),  the 
error generated by such an uncertainty would be:

Error Voltage = 10*SIN(2*pi*f*1 usec) = 62.8 mv

The  12-bit A/D will divide the 20 V full scale input range  into 
4096  equal  parts  or  "counts".  An  error  of  62.8  mv  would 
correspond to 

.0628 V * (4096 counts / 20 V) = 12.9 counts!

Such an error reduces the system accuracy to about what would  be 
expected  of an eight bit system. Clearly, this could  easily  be 
the  most  significant error in the system.  The  maximum  timing 
jitter allowable that would give 1/2 count or less of error for a 
12 bit system would be:

T = ARCSIN(Error Voltage / Volts Full Scale) / 2*pi*f  

In this case

T = ARCSIN(.00244 V/10) / 2*pi*1000 = 39 nsec !

The only way to achieve such stability in a computer is to have a 
clock  derived  from  a crystal  oscillator  directly  start  A/D 
conversions. The DMA process would then be paced by the A/D's End 
of Convert Signal to ensure that only valid data are transferred. 
DMA  for data acquisition, then, must be paced by a very  regular 
clock.

Besides  being more demanding in terms of frequency  than  office 
automation,  data  acquisition must also be "event driven"  to  a 
much  greater  extent. That is, it must respond  and  synchronize 
itself to asynchronous events over which it may have little or no 
control. 

Often,  it  is not useful to take a random "snapshot"  of  10,000 
precisely timed samples of a signal. Often, one would really like 
to take a snapshot only of the 10,000 samples which contain  some 
event  of  interest. In these cases, the optimal  snapshot  would 
contain  data  leading up to the event, and  data  following  the 
event -- pre- and post-trigger data. The technique for  achieving 
this  is  well  known, and requires three  basic  elements  --  a 
"circular"  memory buffer, some sort of hardware trigger,  and  a 
delay counter.

Data is acquired continuously into the circular buffer. When  the 
buffer is full, it automatically wraps around and begins  filling 
again,  overwriting old data with new. When the hardware  trigger 
occurs, the delay counter begins counting a pre-programmed number 
of additional samples. When the delay counter exhausts its count, 
data  acquisition stops.  The buffer is left with  samples  taken 
both before and after the trigger (Fig. 2). The oldest sample  in 
the buffer is the one which would have been written next if  data 
acquisition  had  continued. The newest sample is  the  one  just 
written,  and  the trigger sample is located by  going  backwards 
through the buffer by the number of samples in the delay.

This  capability is partially inherent in the Personal  Computer.  
Its   DMA  Controller  has an  "Autoinitialize  Mode",  described 
below, which can be used to create the required circular  buffer.  
The hardware trigger and delay counter, however, must be built in 
to  the  data  acquisition  hardware.  The  Burr-Brown  PCI-20000 
Modular  Data  Acquisition  System was the  first  PC-based  data 
acquisition   system   to  offer  this  capability.   All   major 
competitors in this area now offer some capablities like this.


.cp 3

Survey of DMA Techniques

The classical DMA technique which is supported by the IBM  family 
of  PCs  is the "device to memory" technique. A  single  external 
device  (for data acquisition, normally an A/D or D/A  converter) 
communicates   with   the  host  computer's  memory   using   the 
computer's DMA handshaking protocol. Fig. 3 shows a simple  block 
diagram and memory map of this process.

For  purposes of data acquisition, this technique is  illustrated 
in its simplest form in Fig. 4. An external timing source  starts 
an A/D conversion directly. When the conversion is complete,  the 
A/D's data is transmitted directly to memory.  While this process 
is  very fast, it has the disadvantage that only one  channel  of 
analog data is captured and transmitted. There are no  provisions 
for  multiple channels of analog data, or for any other  type  of 
data.

The addition of a multiplexer and programmable counter, as  shown 
in  Fig. 5, allows the acquisition of multiple  analog  channels. 
Conversions are still started by the external timing source. Now, 
however,  when  a  conversion starts, the  counter  advances  the 
multiplexer  to the next channel in the sequence.  Advancing  the 
counter at the start of conversion rather than at the end  allows 
the  multiplexer to settle on the next channel while the  current 
channel is converting. The sample/hold amplifier stores the value 
of  the  current  channel  while the  current  conversion  is  in 
progress. The counter can be made such that it can scan the first 
N  channels  in  sequence, or the last N channels.  Each  time  a 
conversion   starts,  a  different  channel  is   converted   and 
transmitted.  Some  technique  similar to  this  is  employed  on 
virtually all modern DMA-compatible data acquisition boards.

 
Another  level  of utility can be achieved by inserting  a  "list 
memory" between the counter and the multiplexer (Fig. 6). Instead 
of selecting an analog channel, the counter will select a  memory 
location in the list memory. This memory location can contain the 
code  for  any  channel, as well as the code for  a  gain,  if  a 
programmable gain amplifier is used in the system. As above, each 
time  a  conversion starts, the counter advances. In  this  case, 
however,  it  advances  to  the next  memory  location,  and  the 
contents of that memory location specify the channel for the next 
conversion.  

This technique offers several advantages. The list of channels to 
be  scanned  does not have to be sequential. Any  random  channel 
numbers can be programmed in the list. 

If  some channels need to be scanned at higher  frequencies  than 
others,  they can be repeated in the list. For  example,  suppose 
channels 7, 2, and 5 were to be scanned, and channel 2  contained 
higher  frequency information than the other two. A channel  list 
could  be constructed to look like: 2,7,2,5. Channel 2  would  be 
scanned at twice the rate of the others.

If  a programmable gain amplifier is used in the system, and  its 
control  bits are included in the list memory, then each  channel 
can  have a different gain. Normally, this is not possible  under 
DMA control since gain has to be set with software.

The  random-channel  scanner  first  appeared  in  PC-based  data 
acquisition  products  in 1985, again in  Burr-Brown's  PCI-20000 
system.  Since  that  time, it has  become  available  from  most 
suppliers of such boards.

A New Technique

All of the techniques listed above are available in  commercially 
available  plug-in data acquisition boards. All of these  schemes 
have  one limitation in common, however: they can only monitor  a 
single  A/D  converter under DMA control, and no  other  type  of 
device at all. 

Almost  all  data  acquisition boards  have  event  counters  and 
digital I/O on board as well as an A/D converter. This is because 
most  applications  involve more than  simply  monitoring  analog 
channels.  For  example, if an application  requires  correlating 
analog  inputs  with  a position signal from  an  absolute  shaft 
encoder,  then  DMA  cannot be used. The  analog  inputs  can  be 
monitored  under  DMA control, but the digital  inputs  from  the 
shaft encoder cannot.

Alternatively,  if an application requires simultaneous  sampling 
from  several A/D converters, or to several D/A converters,  then 
DMA could not be used. Only one of the converters could be  under 
DMA control.

A technique has been developed that gets around this  limitation. 
Embodied  in the Burr-Brown PCI-20041C Data Acquisition  Carrier, 
it  allows several (up to 64) data acquisition devices  to  share 
the  same DMA channel in the PC. Any device in the system can  be 
used -- A/D converters, digital I/O channels, and/or counters  -- 
and they can be mixed together in the same DMA process.

The  scheme  involves a technique similar to  the  random-channel 
scanner  described above. RAM on the Carrier contains a  list  of 
all  items to be transferred under DMA control.  Each time a  DMA 
transfer  is  requested  (by a pacer  clock,  for  example),  the 
Carrier sends out one "frame" consisting of all the items in  the 
list to a single DMA channel as fast as the computer will  accept 
them.   This frame can consist of any mixture of items  available 
on the Carrier or Modules; A/D readings, digital input  readings, 
and counter data can be intermixed as required (see Fig. 7).   Up 
to  five  Carriers  can be linked  together  in  a  master-slaves 
arrangement, allowing data from all five to be under DMA  control 
simultaneously. 

The DMA list, or frame map, is contained in a block of 128  bytes 
of  memory on the Carrier. Each item in the map consists  of  two 
bytes   representing  the  local  address  of  one  item  to   be 
transferred  under DMA control. There can be up to 64 such  items 
in the list. The last item in the frame also contains an "End  Of 
Frame" flag indicating the end of the list (Fig. 8). 

During  a  DMA transfer, the PC's address and control  lines  are 
removed  from  the  Carrier's local bus, and  replaced  with  the 
contents of one element from the list. This addresses one byte on 
the  Carrier, causing its data to be placed on the data  bus  (or 
taken from the data bus, depending on the direction of transfer). 
When  the  transfer  of the byte is complete, a  counter  on  the 
Carrier  advances  to  the next item in the  list  for  the  next 
transfer.  After  the last item is transferred,  the  counter  is 
reset, pointing once again to the first list element.

A DMA transfer can be requested by several sources in the system. 
Typical  sources  of  transfer requests are the  End  of  Convert 
signal  from an A/D converter, a pulse from the on-board  crystal 
controlled  Pacer  clock,  an external TTL  input  pulse,  or  an 
interrupt from a Trigger circuit.

There are also several triggering methods available to start  and 
stop  sequences  of  DMA transfers. For  data  acquisition  input 
purposes, the method described earlier ( called Start on Command, 
Stop  on  Trigger with Delay) is most useful  since  it  provides 
both  pre-and  post-trigger data. In this case, the  trigger  can 
either  be an external TTL pulse, or it can be  derived  directly 
from  the analog input signal using a PCI-20020M-1  Trigger/Alarm 
Module.

For  continuous  DMA  output  of  analog  waveforms  or   digital 
patterns,  the "Start on Command, Stop on Command" mode  is  most 
useful. It also involves the use of a circular buffer. An  analog 
waveform  can  be constructed in memory,  and  then  continuously 
output through a D/A converter module (or several modules if more 
than one waveform is desired) at the desired frequency using DMA. 
An alternative mode allows the DMA output to begin on a  hardware 
trigger.  During  the DMA output,  a user's program  can  acquire 
data from the same board using a polling or interrupt  technique.  
If  polled  data acquisition is timed by the same clock  used  to 
generate the DMA output, then the two are synchronized. This  can 
be used to build a stimulus-response system.

Conclusion

DMA is a powerful technique for data acquisition. It allows  high 
speed data collection, and it makes background operation  simple. 
When  enhanced by specialized data acquisition hardware,  it  can 
transform   a  Personal  Computer  into  a   full-featured   Data 
Acquisition System with impressive capabilities.