Network Working Group                                       K. Tesink
Request for Comments: 2558                     Telcordia Technologies
Obsoletes: 1595                                            March 1999
Category: Standards Track


                     Definitions of Managed Objects
                    for the SONET/SDH Interface Type

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (1999).  All Rights Reserved.

1.  Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in TCP/IP-based internets.
   In particular, it defines objects for managing Synchronous Optical
   Network/Synchronous Digital Hierarchy (SONET/SDH) interfaces.  This
   document is a companion to the documents that define Managed Objects
   for the DS1/E1/DS2/E2 and DS3/E3 Interface Types [24][25].

   Textual Conventions used in this MIB are defined in [6] and [36].

   This memo replaces RFC 1595 [30]. Changes relative to RFC 1595 are
   summarized in the MIB module's REVISION clause.

Table of Contents

   1 Abstract ..............................................    1
   2 The SNMP Network Management Framework .................    2
   3 Overview ..............................................    3
   3.1 Use of the ifTable ..................................    4
   3.2 Use of ifTable for  SONET/SDH  Medium/Section/Line
       Layer ...............................................    5
   3.3 Use of ifTable for SONET/SDH Paths ..................    6
   3.4 Use of ifTable for SONET/SDH VTs/VCs ................    7
   3.5 SONET/SDH Terminology ...............................    8
   4 Object Definitions ....................................   16
   4.1 The SONET/SDH Medium Group ..........................   19



Tesink                      Standards Track                     [Page 1]

RFC 2558                   SONET/SDH Objects                  March 1999


   4.2 The SONET/SDH Section Group .........................   23
   4.2.1 The SONET/SDH Section Current Group ...............   23
   4.2.2 The SONET/SDH Section Interval Group ..............   26
   4.3 The SONET/SDH Line Group ............................   28
   4.3.1 The SONET/SDH Line Current Group ..................   28
   4.3.2 The SONET/SDH Line Interval Group .................   30
   4.4 The SONET/SDH Far End Line Group ....................   32
   4.4.1 The SONET/SDH Far End Line Current Group ..........   33
   4.4.2 The SONET/SDH Far End Line Interval Group .........   34
   4.5 The SONET/SDH Path Group ............................   37
   4.5.1 The SONET/SDH Path Current Group ..................   37
   4.5.2 The SONET/SDH Path Interval Group .................   39
   4.6 The SONET/SDH Far End Path Group ....................   42
   4.6.1 The SONET/SDH Far End Path Current Group ..........   42
   4.6.2 The SONET/SDH Far End Path Interval Group .........   44
   4.7 The SONET/SDH Virtual Tributary Group ...............   46
   4.7.1 The SONET/SDH VT Current Group ....................   46
   4.7.2 The SONET/SDH VT Interval Group ...................   49
   4.8 The SONET/SDH Far End VT Group ......................   51
   4.8.1 The SONET/SDH Far End VT Current Group ............   51
   4.8.2 The SONET/SDH Far End VT Interval Group ...........   53
   4.9 Conformance Information .............................   55
   4.10 Compliance Statements ..............................   56
   5 Acknowledgments .......................................   65
   6 Security Considerations ...............................   65
   7 References ............................................   66
   8 Author's Address ......................................   69
   9 Intellectual Property .................................   69
   Appendix A ..............................................   70
   Appendix B ..............................................   72
   Full Copyright Statement ................................   74

2.  The SNMP Network Management Framework

   The SNMP Management Framework presently consists of five major
   components:

   0    An overall architecture, described in RFC 2271 [1].

   0    Mechanisms for describing and naming objects and events for the
        purpose of management.  The first version of this Structure of
        Management Information (SMI) is called SMIv1 and described in
        STD 16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4].
        The second version, called SMIv2, is described in RFC 1902 [5],
        RFC 1903 [6] and RFC 1904 [7].






Tesink                      Standards Track                     [Page 2]

RFC 2558                   SONET/SDH Objects                  March 1999


   0    Message protocols for transferring management information.  The
        first version of the SNMP message protocol is called SNMPv1 and
        described in STD 15, RFC 1157 [8].  A second version of the SNMP
        message protocol, which is not an Internet standards track
        protocol, is called SNMPv2c and described in RFC 1901 [9] and
        RFC 1906 [10].  The third version of the message protocol is
        called SNMPv3 and described in RFC 1906 [10], RFC 2272 [11] and
        RFC 2274 [12].

   0    Protocol operations for accessing management information.  The
        first set of protocol operations and associated PDU formats is
        described in STD 15, RFC 1157 [8].  A second set of protocol
        operations and associated PDU formats is described in RFC 1905
        [13].

   0    A set of fundamental applications described in RFC 2273 [14] and
        the view-based access control mechanism described in RFC 2275
        [15].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the mechanisms defined in the SMI.

   This memo specifies a MIB module that is compliant to the SMIv2.  A
   MIB conforming to the SMIv1 can be produced through the appropriate
   translations.  The resulting translated MIB must be semantically
   equivalent, except where objects or events are omitted because no
   translation is possible (e.g., use of Counter64).  Some machine
   readable information in SMIv2 will be converted into textual
   descriptions in SMIv1 during the translation process.  However, this
   loss of machine readable information is not considered to change the
   semantics of the MIB.

3.  Overview

   These objects are used when the particular media being used to
   realize an interface is a SONET/SDH interface.  At present, this
   applies to these values of the ifType variable in the Internet-
   standard MIB:

        sonet (39), sonetPath (50), sonetVT (51)

   The definitions contained herein are based on the SONET/SDH
   specifications in ANSI T1.105 and T1.106-1988 [19][20][21] and CCITT
   G.707, 708, 709, and G.783 [26][27][28][29].






Tesink                      Standards Track                     [Page 3]

RFC 2558                   SONET/SDH Objects                  March 1999


3.1.  Use of the ifTable

   This section specifies how the MIB II interfaces group, as defined in
   [23], is used for SONET/SDH interfaces.  The SONET/SDH layers support
   several multiplexing possibilities.

   For example in SONET, an Synchronous Transport Signal 3 (STS-3) has 3
   SONET Paths, and a STS-3c has 1 SONET Path. Another example could be
   a STS-12 having 4 SONET STS-3c Paths.  Similarly, a SONET Synchronous
   Payload Envelope (SPE) can carry many Virtual Tributaries (VTs), for
   example, one SONET SPE can carry 28 VT1.5s.  It is important to note
   that an SPE and a VT in SONET is collectively referred to as a
   Virtual Container (VC) in SDH.  Also, an STS is called Synchronous
   Transport Module (STM) in SDH.

   Not all SONET/SDH equipment terminates all SONET/SDH layers.  For
   example, a SONET/SDH STE regenerator terminates SONET/SDH Sections
   only, and is transparent for all layers above that.  SONET/SDH Add-
   Drop multiplexers and Digital Cross Connect Systems terminate
   SONET/SDH Lines. SONET/SDH Terminal Multiplexers may also terminate
   SONET/SDH Paths and VTs/VCs.

   MIB II [16], as extended by [23], accommodates these cases by
   appropriate use of the MIB II system group, and the interfaces group.
   The system group can name and describe the type of managed resource.
   The interfaces group defines which SONET/SDH layers apply, how these
   layers are configured and multiplexed.  This is achieved by proper
   representation of SONET/SDH Layers by ifEntries as defined in [23],
   as follows:






















Tesink                      Standards Track                     [Page 4]

RFC 2558                   SONET/SDH Objects                  March 1999


                 _____________________________
                |             |          |    |  >
                |             |          |    |  |
                |    VT 1     |..........|VT K|   > K ifEntries
                |             |          |    |  |
                |_____________|__________|____|  >
                |               |      |      |  >
                |               |      |      |  |
                |    Path 1     |......|Path L|   > L ifEntries
                |               |      |      |  |
                |_______________|______|______|  >
                |                             |  >
                |                             |  |
                |    Line                     |  |
                |                             |  |
                |_____________________________|  |
                |                             |  |
                |                             |  |
                |    Section Layer            |   > 1 ifEntry
                |                             |  |
                |_____________________________|  |
                |                             |  |
                |                             |  |
                |    Physical Medium Layer    |  |
                |                             |  |
                |_____________________________|  >

                Use of ifTable for a SONET/SDH port

   The exact configuration and multiplexing of the layers is maintained
   in the ifStackTable [23].

3.2.  Use of ifTable for SONET/SDH Medium/Section/Line Layer

   Only the ifGeneralInformationGroup needs to be supported.

   ifTable Object    Use for combined SONET/SDH
                     Medium/Section/Line Layer
   ======================================================================
    ifIndex           Interface index.

    ifDescr           SONET/SDH Medium/Section/Line

    ifType            sonet(39)

    ifSpeed           Speed of line rate for SONET/SDH,
                      (e.g., 155520000 bps).




Tesink                      Standards Track                     [Page 5]

RFC 2558                   SONET/SDH Objects                  March 1999


    ifPhysAddress     The value of the Circuit Identifier.
                      If no Circuit Identifier has been assigned
                      this object should have an octet string with
                      zero length.

    ifAdminStatus     Supports read-only access.
                      The desired administrative status of the
                      interface.

    ifOperStatus      The value testing(3) is not used.
                      This object assumes the value down(2),
                      if the objects sonetSectionCurrentStatus
                      and sonetLineCurrentStatus have
                      any other value than sonetSectionNoDefect(1)
                      and sonetLineNoDefect(1), respectively.

    ifLastChange      sysUpTime at the last change in ifOperStatus.

    ifName            Textual name of the interface or an OCTET STRING
                      of zero length.

    ifLinkUpDownTrapEnable   Default value is enabled(1).
                             Just read-only access may be supported.

    ifHighSpeed       Speed of line in Mega-bits per second
                      (e.g., 155 Mbps)

    ifConnectorPresent Set to true(1).

    ifAlias            The (non-volatile) alias name for this interface
                       as assigned by the network manager.

3.3.  Use of ifTable for SONET/SDH Paths

   Only the ifGeneralInformationGroup needs to be supported.

   ifTable Object    Use for SONET/SDH Paths
   =========================================
    ifIndex           Interface index.

    ifDescr           SONET/SDH Path

    ifType            sonetPath(50)

    ifSpeed           set to speed of SONET/SDH path
                      (e.g., an STS-1 path has a
                      rate of 50112000 bps.)




Tesink                      Standards Track                     [Page 6]

RFC 2558                   SONET/SDH Objects                  March 1999


    ifPhysAddress     Circuit Identifier or OCTET STRING of zero length.

    ifAdminStatus     Supports read-only access.
                      The desired administrative status of the
                      interface.

    ifOperStatus      This object assumes the value down(2),
                      if the object sonetPathCurrentStatus has
                      any other value than sonetPathNoDefect(1).

    ifLastChange      sysUpTime at the last change in ifOperStatus.

    ifName            Textual name of the interface or an OCTET STRING
                      of zero length.

    ifLinkUpDownTrapEnable   Default value is disabled(2).
                             Just read-only access may be supported.

    ifHighSpeed       Set to rate of SONET/SDH path
                      in Mega-bits per second.

    ifConnectorPresent Set to false(2).

    ifAlias            The (non-volatile) alias name for this interface
                       as assigned by the network manager.

3.4.  Use of ifTable for SONET/SDH VTs/VCs

   Only the ifGeneralInformationGroup needs to be supported.

   ifTable Object    Use for SONET/SDH VTs/VCs
   ===========================================
    ifIndex           Interface index.

    ifDescr           SONET/SDH VT/VC

    ifType            sonetVT(51)


    ifSpeed           Set to speed of VT/VC
                      (e.g., a VT1.5 has a rate of
                      1728000 bps.)

    ifPhysAddress     Circuit Identifier or OCTET STRING of zero length.

    ifAdminStatus     Supports read-only access.
                      The desired administrative status of the
                      interface.



Tesink                      Standards Track                     [Page 7]

RFC 2558                   SONET/SDH Objects                  March 1999


    ifOperStatus      This object assumes the value down(2),
                      if the object sonetVTCurrentStatus has
                      any other value than sonetVTNoDefect(1).

    ifLastChange      sysUpTime at the last change in ifOperStatus.

    ifName            Textual name of the interface or an OCTET STRING
                      of zero length.

    ifLinkUpDownTrapEnable   Default value is disabled(2).
                             Just read-only access may be supported.

    ifHighSpeed       Set to rate of VT in Mega-bits per second.

    ifConnectorPresent Set to false(2).

    ifAlias            The (non-volatile) alias name for this interface
                       as assigned by the network manager.

3.5.  SONET/SDH Terminology

   The terminology used in this document to describe error conditions on
   a SONET circuit as monitored by a SONET system are from the T1.231
   [22][31][35].  The terminology used in this document to describe
   error conditions on a SDH circuit as monitored by a SDH system are
   from the CCITT G.783 [29].  Only the SONET Performance Monitoring
   terminology is defined in this document.  The definitions for SDH
   Performance Monitoring terms are similar but not identical, and they
   can be found in [29].  If the definition in this document does not
   match the definition in the T1.231 document, the implementer should
   follow the definition described in this document.  In some cases
   other or additional references are used as compared with the ones
   cited above. This will be indicated in the text.

   Section Loss Of Frame Failure (Out of Frame Event, Severely
        Errored Frame Defect)
        An Out of Frame (OOF) event (or Severely Errored Frame defect)
        is the occurrence of four contiguous errored frame alignment
        words.  A frame alignment word occupies the A1 and A2 bytes of
        an STS frame, and is defined in T1.105.  The SEF defect is
        terminated when two contiguous error-free frame words are
        detected.  Any implementation of the frame recovery circuitry
        which achieves realignment following an OOF within the 250
        microsecond (two frames) interval implied by this definition is
        acceptable.






Tesink                      Standards Track                     [Page 8]

RFC 2558                   SONET/SDH Objects                  March 1999


        A Loss of Frame (LOF) defect is declared when an OOF/SEF defect
        persists for a period of 3 milliseconds.  The LOF defect is
        terminated when the incoming signal remains continuously in-
        frame for a period of 1 ms to 3 ms.

        A LOF failure is declared when the LOF defect persists for a
        period of 2.5 +/- 0.5 seconds, except when an LOS defect or
        failure is present.  The LOF failure is cleared when the LOS
        failure is declared, or when the LOF defect is absent for 10 +/-
        0.5 seconds.

   Loss of Signal
        The Loss of Signal (LOS) defect is declared when no transitions
        are detected on the incoming signal (before descrambling).  The
        LOS defect is detected  upon observing 2.3 to 100 microseconds
        of no transitions.  The LOS defect is cleared after a 125
        microsecond interval (one frame) during which no LOS defect is
        detected.

        The LOS failure is declared when the LOS defect persists for a
        period of 2.5 +/- 0.5 seconds, or if LOS defect is present when
        the criteria for LOF failure declaration have been met.  The LOS
        failure is cleared when the LOS defect is absent for a period of
        10 +/- 0.5 seconds.  Declaration of LOS failure clears any
        existing LOF failure.  Clearing the LOS failure allows immediate
        declaration of the LOF failure if conditions warrant.

   STS-Path Loss of Pointer
        A Loss of Pointer (LOP) defect is declared when either a valid
        pointer is not detected in eight consecutive frames, or when
        eight consecutive frames are detected with the New Data Flag
        (NDF) set to "1001" without a valid concatenation indicator (see
        ANSI T1.105).  A LOP defect is terminated when either a valid
        pointer with a normal NDF set to "0110", or a valid
        concatenation indicator is detected for three contiguous frames.
        Incoming STS-Path AIS shall not result in the declaration of a
        LOP defect.

        An STS-Path LOP failure is declared when the STS-Path LOP defect
        persists for a period of 2.5 +/- 0.5 seconds.  A STS-Path LOP
        failure is cleared when the STS-Path LOP defect is absent for 10
        +/- 0.5 seconds.

   VT Loss of Pointer
        A VT LOP defect is declared when either a valid pointer is not
        detected in eight consecutive VT superframes, or when eight
        consecutive VT superframes are detected with the NDF set to
        "1001" without a valid concatenation indicator.  A VT LOP defect



Tesink                      Standards Track                     [Page 9]

RFC 2558                   SONET/SDH Objects                  March 1999


        is terminated when either a valid pointer with a normal NDF set
        to "0110", or a valid concatenation indicator is detected for
        three contiguous VT superframes.  Incoming VT-Path AIS shall not
        result in declaring a VT LOP defect.

        A VT LOP failure is declared when the VT LOP defect persists for
        2.5 +/- 0.5 seconds.  A VT LOP failure is cleared when the VT
        LOP defect is absent for 10 +/- 0.5 seconds.

   Line Alarm Indication Signal
        A Line Alarm Indication Signal (L-AIS) is defined in ANSI
        T1.105.  The following criteria are specific to the L-AIS
        defect:

        --  Line AIS defect is detected as a "111" pattern in bits 6, 7,
        and 8 of the K2 byte in five consecutive frames.

        --  Line AIS defect is terminated when bits 6, 7, and 8 of the
        K2 byte do not contain the code "111" for five consecutive
        frames.

        A Line AIS failure is declared when the Line AIS defect persists
        for a period of 20.5 +/- 0.5 seconds.  A Line AIS failure is
        cleared when the Line AIS defect is absent for 10 +/- 0.5
        seconds.

   STS-Path Alarm Indication Signal
        The STS-Path Alarm Indication Signal (AIS) is defined in ANSI
        T1.105 as all ones in bytes H1, H2, and H3 as well as all ones
        in the entire STS SPE.  The following criteria are specific to
        the STS-Path AIS defect:

        -- STS-Path AIS defect is detected as all ones in bytes H1 and
        H2 in three contiguous frames.

        -- The STS-Path AIS defect is terminated when a valid STS
        Pointer is detected with the NDF set to "1001" (inverted) for
        one frame, or  "0110" (normal) for three contiguous frames.

        An STS-Path AIS failure is declared when the STS-Path AIS defect
        persists for 2.5 +/- 0.5 seconds.  An STS-Path AIS failure is
        cleared when the STS-Path AIS defect is absent for 10 +/- 0.5
        seconds.

   VT-Path Alarm Indication Signal
        The VT-Path Alarm Indication Signal (AIS) is only applicable for
        VTs in the floating mode of operation.  VT-Path AIS is used to
        alert the downstream VT Path Terminating Entity (PTE) of an



Tesink                      Standards Track                    [Page 10]

RFC 2558                   SONET/SDH Objects                  March 1999


        upstream failure.  Upon detection of a failure, Line AIS, or
        STS-Path AIS, an STS PTE will generate downstream VT-Path AIS if
        the STS Synchronous Payload Envelope (SPE) is carrying floating
        VTs.  VT-Path AIS is specified in ANSI T1.105 as all ones in
        bytes V1, V2, V3, and V4, as well as all ones in the entire VT
        SPE.  The following criteria are specific to VT-Path AIS defect:

        --  VT-Path AIS defect is detected by a VT PTE as all ones in
        bytes V1 and V2 in three contiguous VT superframes.

        --  VT-Path AIS defect is terminated when valid VT pointer with
        a valid VT size is detected with the NDF set to "1001"
        (inverted) for one VT superframe, or "0110" (normal) for three
        contiguous VT superframes are detected.

        A VT-Path AIS failure is declared when the VT-Path AIS defect
        persists for 2.5 +/- 0.5 seconds.  A VT-Path AIS failure is
        cleared when the VT-Path AIS defect is absent for 10 +/- 0.5
        seconds.

   Line Remote Defect Indication
        Line Remote Defect Indication (RDI) (aka Line FERF) signal is
        the occurrence of a "110" pattern in bit positions 6, 7, and 8
        of the K2 byte in STS-1 #1 of the STS-N signal.  Line RDI is
        defined in ANSI T1.105.  The following criteria are specific to
        Line RDI defect:

        --  Line RDI defect is a "110" code in bits 6, 7, and 8 of the
        K2 byte of in STS-1 #1 in x consecutive frames, where x = 5
        [31][35] or 10 [35].

        --  Line RDI defect is terminated when any code other than "110"
        is detected in bits 6, 7, and 8 of the K2 byte in x consecutive
        frames, where x = 5 [31][35] or 10 [35].

        A Line Remote Failure Indication (RFI) failure is declared when
        the incoming Line RDI defects lasts for 2.5 +/- 0.5 seconds.
        The Line RFI failure is cleared when no Line RDI defects are
        detected for 10 +/- 0.5 seconds.

   STS-Path Remote Defect Indication
        STS-Path RDI (aka STS-Path FERF) signal shall be generated
        within 100 milliseconds by the STS PTE upon detection of an AIS
        or LOP defect.  Transmission of the STS-Path RDI signal shall
        cease within 100 milliseconds when the STS PTE no longer detects
        STS-Path AIS or STS-Path LOP defect.  The STS-Path RDI  shall
        accurately report the presence or absence of STS-Path AIS or
        STS-Path LOP defects.  STS-Path RDI defect is defined in ANSI



Tesink                      Standards Track                    [Page 11]

RFC 2558                   SONET/SDH Objects                  March 1999


        T1.105.  The following requirements are specific to the STS-Path
        RDI defect:

        --  STS-Path RDI is detected by all STS PTEs.  STS-Path RDI is
        detected by the upstream STS PTE as a "1" in bit five of the
        Path Status byte (G1) for x consecutive frames, where x = 5 [31]
        or 10 [35].

        --  Removal of STS-Path Remote Defect Indication is detected by
        a "0" in bit 5 of the G1 byte in x consecutive frames, where x =
        5 [31] or 10 [35].

        An STS-Path Remote Failure Indication (RFI) failure is declared
        when the incoming STS-Path RDI defects lasts for 2.5 +/- 0.5
        seconds.  The STS-Path RFI failure is cleared when no STS-Path
        RDI defects are detected for 10 +/- 0.5 seconds.

   VT-Path Remote Defect Indication
        VT Path RDI (aka VT Path FERF) signal shall be generated within
        100 milliseconds by the VT PTE upon detection of a VT-Path AIS
        or LOP defect.  Transmission of the VT-Path RDI signal shall
        cease within 100 milliseconds when the VT PTE no longer detects
        VT-Path AIS or VT-Path LOP defect.  The VT-Path RDI  shall
        accurately report the presence or absence of VT-Path AIS or VT-
        Path LOP defects.  VT-Path RDI defect is defined in ANSI T1.105.
        The following requirements are specific to VT-Path RDI defect:

        --  VT-Path RDI defect is the occurrence of a "1" in bit 4 of
        the VT-Path Overhead byte (V5) in x consecutive frames, where x
        = 5 [31] or 10 [35].

        --  VT-Path RDI defect is terminated when a "0" is detected in
        bit 4 of the VT-Path Overhead byte (V5) for x consecutive
        frames, where x = 5 [31] or 10 [35].

        A VT-Path Remote Failure Indication (RFI) (derived) failure is
        declared when the incoming VT-Path RDI defects lasts for 2.5 +/-
        0.5 seconds.  The VT-Path RFI failure is cleared when no VT-Path
        RDI defects are detected for 10 +/- 0.5 seconds.

   VT-Path Remote Failure Indication
        The VT-Path RFI signal is only required for the case of byte
        synch mapped DS1s where the DS1 frame bit is not mapped.  The
        VT-Path RFI is specified in ANSI T1.105, where it is currently
        called VT path yellow.  When provided, the VT-Path RFI signal is
        used to indicate the occurrence of far-end failures.  When the
        VT-Path RFI is not provided, far-end failures are derived from
        local timing of the VT-Path RDI defect.  The VT-Path RFI failure



Tesink                      Standards Track                    [Page 12]

RFC 2558                   SONET/SDH Objects                  March 1999


        is declared within 5 ms of detecting the incoming VT-Path RFI
        Signal.  The VT-Path Remote Failure Indication (RFI) failure is
        cleared within 50 ms of detecting the removal of the incoming
        VT-Path RFI signal.

   Coding Violation
        Coding Violations (CV) are Bit Interleaved Parity (BIP) errors
        that are detected in the incoming signal.  CV counters are
        incremented for each BIP error detected.  That is, each BIP-8
        can detect up to eight errors per STS-N frame, with each error
        incrementing the CV counter.  Section CVs shall be collected
        using the BIP-8 in the B1 byte located in the Section Overhead
        of STS-1 #1.  Line CVs shall be collected using the BIP-8s in B2
        bytes located in the Line Overhead of each STS-1 (since all CVs
        on an STS-N line are counted together, this is equivalent to
        counting each error in the BIP-8*N contained in the B2 bytes of
        the STS-N Line Overhead).  Thus, on an STS-N signal, up to 8 x N
        CVs may occur in each frame.  Path CVs shall be collected using
        the BIP-8 in the B3 byte of the STS-Path Overhead of the STS
        SPE.  VT CVs shall be collected using the BIP-2 in the V5
        overhead byte of the floating VT.

   Errored Seconds
        At each layer, an Errored Second (ES) is a second with one or
        more Coding Violations at that layer OR one or more incoming
        defects (e.g., SEF, LOS, AIS, LOP) at that layer has occurred.

   Severely Errored Seconds
        According to [22][31][32][34][35] at each layer, an Severely
        Errored Second (SES) is a second with x or more CVs at that
        layer, or a second during which at least one or more incoming
        defects at that layer has occurred.  The values of x in
        RFC1595[30] were based on [22] and [32] (see Appendix B). These
        values have subsequently been relaxed in [31][34][35]. In
        addition, according to G.826 [33] SESs are measured as a
        percentage of errored blocks.

        To deal with these sets of definitions this memo defines an
        object sonetSESThresholdSet that determines the correct
        interpretation of SES. For backward compatibility, if this
        object is not implemented the interpretation of Appendix B shall
        apply.  Otherwise, a more recent interpretation is suggested.
        An agent is not required to support all sets of definitions.

        Note that if a manager changes the value of this object all SES
        statistics collected prior to this change shall be invalidated.





Tesink                      Standards Track                    [Page 13]

RFC 2558                   SONET/SDH Objects                  March 1999


   Severely Errored Framing Seconds
        A Severely Errored Framing Second (SEFS) is a second containing
        one or more SEF events.  This counter is only counted at the
        Section Layer.

   Unavailable Seconds
        At the Line, Path, and VT layers, an unavailable second is
        calculated by counting the number of seconds that the interface
        is unavailable.  At each layer, the SONET/SDH interface is said
        to be unavailable at the onset of 10 contiguous SESs.  The 10
        SESs are included in unavailable time.  Once unavailable, the
        SONET/SDH interface becomes available at the onset of 10
        contiguous seconds with no SESs.  The 10 seconds with no SESs
        are excluded from unavailable time.  With respect to the
        SONET/SDH error counts at each layer, all counters at that layer
        are incremented while the SONET/SDH interface is deemed
        available at that layer.  While the interface is deemed
        unavailable at that layer, the only count that is incremented is
        UASs at that layer.

        Note that this definition implies that the agent cannot
        determine until after a ten second interval has passed whether a
        given one-second interval belongs to available or unavailable
        time.  If the agent chooses to update the various performance
        statistics in real time then it must be prepared to
        retroactively reduce the ES, SES, and SEFS counts by 10 and
        increase the UAS count by 10 when it determines that available
        time has been entered.  It must also be prepared to reduce the
        CV count by the number of violations counted since the onset of
        unavailable time.  The agent must be similarly prepared to
        retroactively decrease the UAS count by 10 and increase the ES
        and CV counts as necessary upon entering available time.  A
        special case exists when the 10 second period leading to
        available or unavailable time crosses a 900 second statistics
        window boundary, as the foregoing description implies that the
        CV, ES, SES, SEFS, and UAS counts the PREVIOUS interval must be
        adjusted.  In this case successive GETs of the affected
        sonetPathIntervalSES and sonetPathIntervalUAS objects (and the
        analogous Line and VT objects also) objects will return
        differing values if the first GET occurs during the first few
        seconds of the window.

        According to ANSI T1.231 unavailable time begins at the _onset_
        of 10 contiguous severely errored seconds -- that is,
        unavailable time starts with the _first_ of the 10 contiguous
        SESs.  Also, while an interface is deemed unavailable all
        counters for that interface are frozen except for the UAS count.
        It follows that an implementation which strictly complies with



Tesink                      Standards Track                    [Page 14]

RFC 2558                   SONET/SDH Objects                  March 1999


        this standard must _not_ increment any counters other than the
        UAS count -- even temporarily -- as a result of anything that
        happens during those 10 seconds.  Since changes in the signal
        state lag the data to which they apply by 10 seconds, an ANSI-
        compliant implementation must pass the one-second statistics
        through a 10-second delay line prior to updating any counters.
        That can be done by performing the following steps at the end of
        each one second interval.

   i)   Read near/far end CV counter and alarm status flags from the
        hardware.

   ii)  Accumulate the CV counts for the preceding second and compare
        them to the ES and SES threshold for the layer in question.
        Update the signal state and shift the one-second CV counts and
        ES/SES flags into the 10-element delay line.  Note that far-end
        one-second statistics are to be flagged as "absent" during any
        second in which there is an incoming defect at the layer in
        question or at any lower layer.

   iii) Update the current interval statistics using the signal state
        from the _previous_ update cycle and the one-second CV counts
        and ES/SES flags shifted out of the 10-element delay line.

        This approach is further described in Appendix A. An agent may
        choose to use this approach in lieu of retroactive adjustments
        to the counters.

        In any case, a linkDown trap shall be sent only after the agent
        has determined for certain that the unavailable state has been
        entered, but the time on the trap will be that of the first UAS
        (i.e., 10 seconds earlier).  A linkUp trap shall be handled
        similarly.

   Unequipped
        If a Path or VT connection is not provisioned (idle) the SONET
        equipment will signal this state by transmitting the Path or VT
        Signal Label as follows:
        - byte C2 of the STS Path Overhead equal to 0 for an unequipped
        Path,
        - byte V5 of the VT Path Overhead equal to 0 for an unequipped
        VT.

   Signal Label Mismatch
        A Path or VT connection is not correctly provisioned if a
        received Path or VT Signal Label mismatch occurs.  A received
        Signal Label is considered mismatched if it does not equal
        either the locally provisioned value or the value 'equipped



Tesink                      Standards Track                    [Page 15]

RFC 2558                   SONET/SDH Objects                  March 1999


        non-specific' (1 hex). Note that any received non-zero Signal
        Label is considered a locally provisioned value of 'equipped
        non-specific'.  Only in-service, provisioned Path Terminating
        equipment can detect mismatched Signal labels. It is considered
        provisioned if it has been configured for a mapping and has been
        assigned signals to and from which the mapping takes place.
        While a Path is unequipped or has mismatched signal labels
        ES/SES counts continue, but these conditions do not themselves
        contribute to ES/SES.

   Circuit Identifier
        This is a character string specified by the circuit vendor, and
        is useful when communicating with the vendor during the
        troubleshooting process.

4.  Object Definitions

SONET-MIB DEFINITIONS ::= BEGIN


IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE,
    Integer32, transmission
          FROM SNMPv2-SMI
    DisplayString, TruthValue
          FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP
          FROM SNMPv2-CONF
    ifIndex
          FROM IF-MIB
    PerfCurrentCount, PerfIntervalCount
          FROM PerfHist-TC-MIB;

--  This is the MIB module for the SONET/SDH Interface objects.


sonetMIB MODULE-IDENTITY
    LAST-UPDATED "9810190000Z"
    ORGANIZATION "IETF AToM MIB Working Group"
    CONTACT-INFO
      "Kaj Tesink
       Telcordia Technologies
       Tel: (732) 758-5254
       Fax: (732) 758-2269
       E-mail: kaj@research.telcordia.com."
    DESCRIPTION
         "The MIB module to describe
         SONET/SDH interfaces objects."



Tesink                      Standards Track                    [Page 16]

RFC 2558                   SONET/SDH Objects                  March 1999


    REVISION      "9810190000Z"
    DESCRIPTION
        "The key changes made to this MIB module
        since its initial publication in RFC 1595
        are as follows.

        (1) The MODULE-IDENTITY has been updated to reflect the
            changes to the MIB.

        (2) Where applicable, the textual conventions
            PerfCurrentCount and PerfIntervalCount from
            PerfHist-TC-MIB have been used in place of Gauge32.

        (3) An agent now has the option to delay updates to
            the various performance counts in lieu of performing
            retroactive adjustments upon entering into or exiting
            from unavailable time. This implementation option is
            described in Appendix A of this memo.

        (4) In order to make the SONET-MIB more useful for
            circuit provisioning, the formerly read-only objects
            sonetMediumType, sonetMediumLineCoding,
            sonetMediumLineType, and sonetMediumCircuitIdentifier
            have been given a MAX-ACCESS of read-write. The
            MIN-ACCESS remains read-only.

        (5) The DESCRIPTION clause for sonetMediumTimeElapsed has
            been updated to describe its behaviour if the duration
            of the current interval exceeds the maximum value.

        (6) The DESCRIPTION clause for sonetMediumValidIntervals
            has been updated to describe its behaviour when some
            intervals may be unavailable, and the object
            sonetMediumInvalidIntervals has been added to keep
            count of the number of missing intervals (if any).

        (7) The object sonetMediumLoopbackConfig has been added
            to enable or disable loopback configurations.

        (8) Because the error count thresholds for declaring
            severely errored seconds that are specified in ANSI
            T1.231-1993, ITU-T G.826-1995, and ANSI T1.231-1997
            are all different from each other and from the thresholds
            specified in RFC 1595, an enumerated INTEGER object
            sonetSESthresholdSet has been added to allow an agent
            to specify which threshold set is in use. Text has
            been added to Section 3 stating that if this object is
            not implemented the thresholds specified in RFC 1595



Tesink                      Standards Track                    [Page 17]

RFC 2558                   SONET/SDH Objects                  March 1999


            should be assumed, and the table containing those
            thresholds has been moved to Appendix B of this memo.

        (9) A column with SYNTAX TruthValue has been added to each
            interval table.  The purpose of the additional column
            is to indicate, for each interval, whether the data
            is valid in the sense intended by ANSI T1.231 clause
            9.1.2.2 [31][35]. The objects in question are:

                sonetSectionIntervalValidData
                sonetLineIntervalValidData
                sonetFarEndLineIntervalValidData
                sonetPathIntervalValidData
                sonetFarEndPathIntervalValidData
                sonetVTIntervalValidData
                sonetFarEndVTIntervalValidData

       (10) The ranges for sonetPathCurrentStatus and
            sonetVTCurrentStatus have been made consistent
            with the DESCRIPTION clauses.

       (11) The conformance information has been updated. Previous
            conformance information from RFC 1595 has been
            deprecated. Some typographical errors in the deprecated
            section have been corrected in order to prevent
            MIB compilation errors."

    REVISION      "9401030000Z"
    DESCRIPTION
        "The RFC1595 version of this MIB module."

    ::= { transmission 39 }


--  This is the MIB module for the SONET/SDH objects

sonetObjects      OBJECT IDENTIFIER ::= { sonetMIB 1 }

sonetObjectsPath  OBJECT IDENTIFIER ::= { sonetMIB 2 }

sonetObjectsVT    OBJECT IDENTIFIER ::= { sonetMIB 3 }


-- groups in the SONET/SDH MIB module

sonetMedium        OBJECT IDENTIFIER ::= { sonetObjects 1 }

sonetSection       OBJECT IDENTIFIER ::= { sonetObjects 2 }



Tesink                      Standards Track                    [Page 18]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetLine          OBJECT IDENTIFIER ::= { sonetObjects 3 }

sonetFarEndLine    OBJECT IDENTIFIER ::= { sonetObjects 4 }

sonetPath          OBJECT IDENTIFIER ::= { sonetObjectsPath 1 }

sonetFarEndPath    OBJECT IDENTIFIER ::= { sonetObjectsPath 2 }

sonetVT            OBJECT IDENTIFIER ::= { sonetObjectsVT 1 }

sonetFarEndVT      OBJECT IDENTIFIER ::= { sonetObjectsVT 2 }

-- the SONET/SDH Medium group

-- SONET/SDH interfaces for some applications may be electrical
-- interfaces and not optical interfaces.  This group handles
-- the configuration information for both optical SONET/SDH
-- interfaces and electrical SONET/SDH interfaces.

sonetMediumTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetMediumEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The SONET/SDH Medium table."
     ::= { sonetMedium 1 }

sonetMediumEntry OBJECT-TYPE
    SYNTAX  SonetMediumEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the SONET/SDH Medium table."
    INDEX   { ifIndex }
     ::= { sonetMediumTable 1 }

SonetMediumEntry ::=
    SEQUENCE {
         sonetMediumType               INTEGER,
         sonetMediumTimeElapsed        Integer32,
         sonetMediumValidIntervals     Integer32,
         sonetMediumLineCoding         INTEGER,
         sonetMediumLineType           INTEGER,
         sonetMediumCircuitIdentifier  DisplayString,
         sonetMediumInvalidIntervals   Integer32,
         sonetMediumLoopbackConfig     BITS
    }




Tesink                      Standards Track                    [Page 19]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetMediumType OBJECT-TYPE
    SYNTAX  INTEGER  {
               sonet(1),
               sdh(2)
            }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "This variable identifies whether a SONET
       or a SDH signal is used across this interface."
    ::= { sonetMediumEntry 1 }

sonetMediumTimeElapsed OBJECT-TYPE
    SYNTAX  Integer32 (1..900)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The number of seconds, including partial seconds,
       that have elapsed since the beginning of the current
       measurement period. If, for some reason, such as an
       adjustment in the system's time-of-day clock, the
       current interval exceeds the maximum value, the
       agent will return the maximum value."
    ::= { sonetMediumEntry 2 }

sonetMediumValidIntervals OBJECT-TYPE
    SYNTAX  Integer32 (0..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The number of previous 15-minute intervals
       for which data was collected.
       A SONET/SDH interface must be capable
       of supporting at least n intervals.
       The minimum value of n is 4.
       The default of n is 32.
       The maximum value of n is 96.
       The value will be <n> unless the measurement was
       (re-)started within the last (<n>*15) minutes, in which
       case the value will be the number of complete 15
       minute intervals for which the agent has at least
       some data. In certain cases (e.g., in the case
       where the agent is a proxy) it is possible that some
       intervals are unavailable.  In this case, this
       interval is the maximum interval number for
       which data is available. "
    ::= { sonetMediumEntry 3 }




Tesink                      Standards Track                    [Page 20]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetMediumLineCoding OBJECT-TYPE
    SYNTAX  INTEGER {
                sonetMediumOther(1),
                sonetMediumB3ZS(2),
                sonetMediumCMI(3),
                sonetMediumNRZ(4),
                sonetMediumRZ(5)
            }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "This variable describes the line coding for
       this interface. The B3ZS and CMI are used for
       electrical SONET/SDH signals (STS-1 and STS-3).
       The Non-Return to Zero (NRZ) and the Return
       to Zero are used for optical SONET/SDH signals."
    ::= { sonetMediumEntry 4 }

sonetMediumLineType OBJECT-TYPE
    SYNTAX  INTEGER {
                sonetOther(1),
                sonetShortSingleMode(2),
                sonetLongSingleMode(3),
                sonetMultiMode(4),
                sonetCoax(5),
                sonetUTP(6)
            }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "This variable describes the line type for
       this interface. The line types are
       Short and Long Range
       Single Mode fiber or Multi-Mode fiber interfaces,
       and coax and UTP for electrical interfaces.  The
       value sonetOther should be used when the Line Type is
       not one of the listed values."
    ::= { sonetMediumEntry 5 }

sonetMediumCircuitIdentifier OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..255))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "This variable contains the transmission
       vendor's circuit identifier, for the
       purpose of facilitating troubleshooting.
       Note that the circuit identifier, if available,



Tesink                      Standards Track                    [Page 21]

RFC 2558                   SONET/SDH Objects                  March 1999


       is also represented by ifPhysAddress."
    ::= { sonetMediumEntry 6 }
sonetMediumInvalidIntervals OBJECT-TYPE
    SYNTAX  Integer32 (0..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The number of intervals in the range from
        0 to sonetMediumValidIntervals for which no
        data is available. This object will typically
        be zero except in cases where the data for some
        intervals are not available (e.g., in proxy
        situations)."
    ::= { sonetMediumEntry 7 }

sonetMediumLoopbackConfig OBJECT-TYPE
    SYNTAX      BITS {
                  sonetNoLoop(0),
                  sonetFacilityLoop(1),
                  sonetTerminalLoop(2),
                  sonetOtherLoop(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The current loopback state of the SONET/SDH interface.  The
        values mean:

          sonetNoLoop
             Not in the loopback state. A device that is not
             capable of performing a loopback on this interface
             shall always return this value.

          sonetFacilityLoop
             The received signal at this interface is looped back
             out through the corresponding transmitter in the return
             direction.

          sonetTerminalLoop
             The signal that is about to be transmitted is connected
             to the associated incoming receiver.

          sonetOtherLoop
             Loopbacks that are not defined here."

    ::= { sonetMediumEntry 8 }

sonetSESthresholdSet    OBJECT-TYPE
    SYNTAX   INTEGER {



Tesink                      Standards Track                    [Page 22]

RFC 2558                   SONET/SDH Objects                  March 1999


               other(1),
               Bellcore1991(2),
               ansi1993(3),
               itu1995(4),
               ansi1997(5)
                      }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
      "An enumerated integer indicating which
       recognized set of SES thresholds that
       the agent uses for determining severely
       errored seconds and unavailable time.

       other(1)
         None of the following.

       Bellcore1991(2)
         Bellcore TR-NWT-000253, 1991 [32], or
         ANSI T1M1.3/93-005R2, 1993 [22].
         See also Appendix B.

       ansi1993(3)
         ANSI T1.231, 1993 [31], or
         Bellcore GR-253-CORE, Issue 2, 1995 [34]

       itu1995(4)
         ITU Recommendation G.826, 1995 [33]

       ansi1997(5)
         ANSI T1.231, 1997 [35]

       If a manager changes the value of this
       object then the SES statistics collected
       prior to this change must be invalidated."
     ::= { sonetMedium 2 }

-- the SONET/SDH Section group

-- this group consists of 2 tables:
-- - the SONET/SDH Section Current Table
-- - the SONET/SDH Section Interval Table



-- the SONET/SDH Section Current Table

-- The SONET/SDH Section



Tesink                      Standards Track                    [Page 23]

RFC 2558                   SONET/SDH Objects                  March 1999


-- current table contains various statistics
-- being collected for the current 15 minute interval.

sonetSectionCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetSectionCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The SONET/SDH Section Current table."
     ::= { sonetSection 1 }

sonetSectionCurrentEntry OBJECT-TYPE
    SYNTAX  SonetSectionCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the SONET/SDH Section Current table."
    INDEX   { ifIndex }
     ::= { sonetSectionCurrentTable 1 }

SonetSectionCurrentEntry ::=
    SEQUENCE {
        sonetSectionCurrentStatus   Integer32,
        sonetSectionCurrentESs      PerfCurrentCount,
        sonetSectionCurrentSESs     PerfCurrentCount,
        sonetSectionCurrentSEFSs    PerfCurrentCount,
        sonetSectionCurrentCVs      PerfCurrentCount
    }


sonetSectionCurrentStatus OBJECT-TYPE
    SYNTAX  Integer32 (1..6)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates the
       status of the interface.
       The sonetSectionCurrentStatus
       is a bit map represented
       as a sum, therefore,
       it can represent multiple defects
       simultaneously.
       The sonetSectionNoDefect should be
       set if and only if
       no other flag is set.

       The various bit positions are:
             1   sonetSectionNoDefect



Tesink                      Standards Track                    [Page 24]

RFC 2558                   SONET/SDH Objects                  March 1999


             2   sonetSectionLOS
             4   sonetSectionLOF"
     ::= { sonetSectionCurrentEntry 1 }

sonetSectionCurrentESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of Errored
       Seconds encountered by a SONET/SDH
       Section in the current 15 minute interval."
     ::= { sonetSectionCurrentEntry 2 }

sonetSectionCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of
       Severely Errored Seconds
       encountered by a SONET/SDH Section in the current 15
       minute interval."
     ::= { sonetSectionCurrentEntry 3 }

sonetSectionCurrentSEFSs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of
       Severely Errored Framing Seconds
       encountered by a SONET/SDH Section in the current
       15 minute interval."
    ::= { sonetSectionCurrentEntry 4 }

sonetSectionCurrentCVs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of Coding
       Violations encountered by a
       SONET/SDH Section in the current 15 minute interval."
     ::= { sonetSectionCurrentEntry 5 }

-- the SONET/SDH Section Interval Table




Tesink                      Standards Track                    [Page 25]

RFC 2558                   SONET/SDH Objects                  March 1999


-- The SONET/SDH Section Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation.  The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.

sonetSectionIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetSectionIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The SONET/SDH Section Interval table."
     ::= { sonetSection 2 }

sonetSectionIntervalEntry OBJECT-TYPE
    SYNTAX  SonetSectionIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the SONET/SDH Section Interval table."
    INDEX   { ifIndex,
              sonetSectionIntervalNumber }
     ::= { sonetSectionIntervalTable 1 }

SonetSectionIntervalEntry ::=
    SEQUENCE {
         sonetSectionIntervalNumber  Integer32,
         sonetSectionIntervalESs     PerfIntervalCount,
         sonetSectionIntervalSESs    PerfIntervalCount,
         sonetSectionIntervalSEFSs   PerfIntervalCount,
         sonetSectionIntervalCVs     PerfIntervalCount,
         sonetSectionIntervalValidData  TruthValue
    }


sonetSectionIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
      "A number between 1 and 96, which identifies the
      interval for which the set of statistics is available.
      The interval identified by 1 is the most recently
      completed 15 minute interval,



Tesink                      Standards Track                    [Page 26]

RFC 2558                   SONET/SDH Objects                  March 1999


      and the interval identified
      by N is the interval immediately preceding the
      one identified
      by N-1."
     ::= { sonetSectionIntervalEntry 1 }

sonetSectionIntervalESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of
       Errored Seconds encountered
       by a SONET/SDH Section in a
       particular 15-minute interval
       in the past 24 hours."
     ::= { sonetSectionIntervalEntry 2 }

sonetSectionIntervalSESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of
       Severely Errored Seconds
       encountered by a SONET/SDH Section in a
       particular 15-minute interval
       in the past 24 hours."
    ::= { sonetSectionIntervalEntry 3 }

sonetSectionIntervalSEFSs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of
       Severely Errored Framing Seconds
       encountered by a SONET/SDH Section in a
       particular 15-minute interval
       in the past 24 hours."
    ::= { sonetSectionIntervalEntry 4 }

sonetSectionIntervalCVs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of Coding



Tesink                      Standards Track                    [Page 27]

RFC 2558                   SONET/SDH Objects                  March 1999


       Violations encountered by a
       SONET/SDH Section in a particular 15-minute interval
       in the past 24 hours."
    ::= { sonetSectionIntervalEntry 5 }

sonetSectionIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates if the data for this
        interval is valid."
    ::= { sonetSectionIntervalEntry 6 }


-- the SONET/SDH Line group

-- this group consists of 2 tables:
-- - the SONET/SDH Line Current Table
-- - the SONET/SDH Line Interval Table


-- the SONET/SDH Line Current Table

-- The SONET/SDH Line
-- current table contains various statistics
-- being collected for the current 15 minute interval.

sonetLineCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetLineCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
      "The SONET/SDH Line Current table."
    ::= { sonetLine 1 }

sonetLineCurrentEntry OBJECT-TYPE
    SYNTAX  SonetLineCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
      "An entry in the SONET/SDH Line Current table."
    INDEX   { ifIndex }
    ::= { sonetLineCurrentTable 1 }

SonetLineCurrentEntry ::=
    SEQUENCE {
         sonetLineCurrentStatus    Integer32,



Tesink                      Standards Track                    [Page 28]

RFC 2558                   SONET/SDH Objects                  March 1999


         sonetLineCurrentESs       PerfCurrentCount,
         sonetLineCurrentSESs      PerfCurrentCount,
         sonetLineCurrentCVs       PerfCurrentCount,
         sonetLineCurrentUASs      PerfCurrentCount
     }


sonetLineCurrentStatus OBJECT-TYPE
    SYNTAX  Integer32 (1..6)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates the
       status of the interface.
       The sonetLineCurrentStatus
       is a bit map represented
       as a sum, therefore,
       it can represent multiple defects
       simultaneously.
       The sonetLineNoDefect should be
       set if and only if
       no other flag is set.

       The various bit positions are:
        1   sonetLineNoDefect
        2   sonetLineAIS
        4   sonetLineRDI"
     ::= { sonetLineCurrentEntry 1 }

sonetLineCurrentESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of Errored
     Seconds encountered by a SONET/SDH
     Line in the current 15 minute interval."
    ::= { sonetLineCurrentEntry 2 }

sonetLineCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH Line in the current 15
     minute



Tesink                      Standards Track                    [Page 29]

RFC 2558                   SONET/SDH Objects                  March 1999


     interval."
    ::= { sonetLineCurrentEntry 3 }

sonetLineCurrentCVs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of Coding
     Violations encountered by a
     SONET/SDH Line in the current 15 minute interval."
    ::= { sonetLineCurrentEntry 4 }

sonetLineCurrentUASs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Unavailable Seconds
     encountered by a SONET/SDH Line in the current 15
     minute
     interval."
    ::= { sonetLineCurrentEntry 5 }


-- the SONET/SDH Line Interval Table

-- The SONET/SDH Line Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation.  The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.

sonetLineIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetLineIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The SONET/SDH Line Interval table."
     ::= { sonetLine 2 }

sonetLineIntervalEntry OBJECT-TYPE
    SYNTAX  SonetLineIntervalEntry



Tesink                      Standards Track                    [Page 30]

RFC 2558                   SONET/SDH Objects                  March 1999


    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the SONET/SDH Line Interval table."
   INDEX   { ifIndex,
             sonetLineIntervalNumber }
   ::= { sonetLineIntervalTable 1 }

SonetLineIntervalEntry ::=
    SEQUENCE {
        sonetLineIntervalNumber    Integer32,
        sonetLineIntervalESs       PerfIntervalCount,
        sonetLineIntervalSESs      PerfIntervalCount,
        sonetLineIntervalCVs       PerfIntervalCount,
        sonetLineIntervalUASs      PerfIntervalCount,
        sonetLineIntervalValidData TruthValue
    }


sonetLineIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "A number between 1 and 96, which identifies the
        interval for which the set of statistics is available.
        The interval identified by 1 is the most recently
        completed 15 minute interval,
        and the interval identified
        by N is the interval immediately preceding the
        one identified
        by N-1."
     ::= { sonetLineIntervalEntry 1 }

sonetLineIntervalESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of
       Errored Seconds encountered
       by a SONET/SDH Line in a
       particular 15-minute interval
       in the past 24 hours."
     ::= { sonetLineIntervalEntry 2 }

sonetLineIntervalSESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount



Tesink                      Standards Track                    [Page 31]

RFC 2558                   SONET/SDH Objects                  March 1999


    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of
       Severely Errored Seconds
       encountered by a SONET/SDH Line in a
       particular 15-minute interval
       in the past 24 hours."
      ::= { sonetLineIntervalEntry 3 }

sonetLineIntervalCVs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "The counter associated with the number of Coding
      Violations encountered by a
      SONET/SDH Line in a
      particular 15-minute interval
      in the past 24 hours."
    ::= { sonetLineIntervalEntry 4 }

sonetLineIntervalUASs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "The counter associated with the
      number of Unavailable Seconds
      encountered by a SONET/SDH Line in
      a particular 15-minute interval
      in the past 24 hours."
    ::= { sonetLineIntervalEntry 5 }

sonetLineIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates if the data for this
        interval is valid."
    ::= { sonetLineIntervalEntry 6 }

-- The SONET/SDH Far End Line group.
-- This group may only be implemented by SONET/SDH (LTEs)
-- systems that provide for a far end block error (FEBE)
-- information at the SONET/SDH Line Layer.




Tesink                      Standards Track                    [Page 32]

RFC 2558                   SONET/SDH Objects                  March 1999


-- This group consists of two tables:
--    SONET/SDH Far End Line Current Table
--    SONET/SDH Far End Line Interval Table



-- The SONET/SDH Far End Line Current Table

-- The SONET/SDH Far End Line Current table contains
-- various statistics being
-- collected for the current 15 minute interval.
-- The statistics are collected from the far end
-- block error code (FEBE)
-- within the third Z2 byte of the Line Overhead
-- in Broadband ISDN applications.
-- The definitions are the same as described for
-- the near-end information.

sonetFarEndLineCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetFarEndLineCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
      "The SONET/SDH Far End Line Current table."
    ::= { sonetFarEndLine 1 }

sonetFarEndLineCurrentEntry OBJECT-TYPE
    SYNTAX  SonetFarEndLineCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
      "An entry in the SONET/SDH Far End Line Current table."
    INDEX   { ifIndex }
    ::= { sonetFarEndLineCurrentTable 1 }

SonetFarEndLineCurrentEntry ::=
    SEQUENCE {
        sonetFarEndLineCurrentESs       PerfCurrentCount,
        sonetFarEndLineCurrentSESs      PerfCurrentCount,
        sonetFarEndLineCurrentCVs       PerfCurrentCount,
        sonetFarEndLineCurrentUASs      PerfCurrentCount
       }

sonetFarEndLineCurrentESs OBJECT-TYPE
   SYNTAX  PerfCurrentCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION



Tesink                      Standards Track                    [Page 33]

RFC 2558                   SONET/SDH Objects                  March 1999


       "The counter associated with the number of Far
       End Errored Seconds encountered by a SONET/SDH
       interface in the current 15 minute interval."
   ::= { sonetFarEndLineCurrentEntry 1 }

sonetFarEndLineCurrentSESs OBJECT-TYPE
   SYNTAX  PerfCurrentCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
       "The counter associated with the number of
       Far End Severely Errored Seconds
       encountered by a SONET/SDH Medium/Section/Line
       interface in the current 15 minute
       interval."
   ::= { sonetFarEndLineCurrentEntry 2 }

sonetFarEndLineCurrentCVs OBJECT-TYPE
   SYNTAX  PerfCurrentCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
       "The counter associated with the number of
       Far End Coding Violations reported via
       the far end block error count
       encountered by a
       SONET/SDH Medium/Section/Line
       interface in the current 15 minute interval."
   ::= { sonetFarEndLineCurrentEntry 3 }

sonetFarEndLineCurrentUASs OBJECT-TYPE
   SYNTAX  PerfCurrentCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
       "The counter associated with the number of
       Far End Unavailable Seconds
       encountered by a
       SONET/SDH Medium/Section/Line
       interface in the current 15 minute interval."
   ::= { sonetFarEndLineCurrentEntry 4 }


-- The SONET/SDH Far End Line Interval Table

-- The SONET/SDH Far End Line Interval Table
-- contains various statistics
-- collected by each system over a maximum



Tesink                      Standards Track                    [Page 34]

RFC 2558                   SONET/SDH Objects                  March 1999


-- of the previous 24 hours of
-- operation.  The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.

sonetFarEndLineIntervalTable OBJECT-TYPE
   SYNTAX  SEQUENCE OF SonetFarEndLineIntervalEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "The SONET/SDH Far End Line Interval table."
   ::= { sonetFarEndLine 2 }

sonetFarEndLineIntervalEntry OBJECT-TYPE
   SYNTAX  SonetFarEndLineIntervalEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
     "An entry in the SONET/SDH Far
     End Line Interval table."
   INDEX   { ifIndex,
             sonetFarEndLineIntervalNumber }
   ::= { sonetFarEndLineIntervalTable 1 }

SonetFarEndLineIntervalEntry ::=
    SEQUENCE {
         sonetFarEndLineIntervalNumber    Integer32,
         sonetFarEndLineIntervalESs       PerfIntervalCount,
         sonetFarEndLineIntervalSESs      PerfIntervalCount,
         sonetFarEndLineIntervalCVs       PerfIntervalCount,
         sonetFarEndLineIntervalUASs      PerfIntervalCount,
         sonetFarEndLineIntervalValidData TruthValue
    }


sonetFarEndLineIntervalNumber OBJECT-TYPE
   SYNTAX  Integer32 (1..96)
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
         "A number between 1 and 96, which identifies the
         interval for which the set of statistics is available.
         The interval identified by 1 is the most recently
         completed 15 minute interval,
         and the interval identified
         by N is the interval immediately preceding the



Tesink                      Standards Track                    [Page 35]

RFC 2558                   SONET/SDH Objects                  March 1999


         one identified
         by N-1."
   ::= { sonetFarEndLineIntervalEntry 1 }

sonetFarEndLineIntervalESs OBJECT-TYPE
   SYNTAX  PerfIntervalCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
        "The counter associated with the number of
        Far End Errored Seconds encountered
        by a SONET/SDH Line
        interface in a particular 15-minute interval
        in the past 24 hours."
  ::= { sonetFarEndLineIntervalEntry 2 }

sonetFarEndLineIntervalSESs OBJECT-TYPE
   SYNTAX  PerfIntervalCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
        "The counter associated with the number of
        Far End Severely Errored Seconds
        encountered by a SONET/SDH Line
        interface in a particular 15-minute interval
        in the past 24 hours."
  ::= { sonetFarEndLineIntervalEntry 3 }

sonetFarEndLineIntervalCVs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
         "The counter associated with the number of
         Far End Coding Violations reported via
         the far end block error count
         encountered by a
         SONET/SDH Line
         interface in a particular 15-minute interval
         in the past 24 hours."
    ::= { sonetFarEndLineIntervalEntry 4 }

sonetFarEndLineIntervalUASs OBJECT-TYPE
   SYNTAX  PerfIntervalCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
       "The counter associated with the number of



Tesink                      Standards Track                    [Page 36]

RFC 2558                   SONET/SDH Objects                  March 1999


       Far End Unavailable Seconds
       encountered by a
       SONET/SDH Line
       interface in a particular 15-minute interval
       in the past 24 hours."
   ::= { sonetFarEndLineIntervalEntry 5 }

sonetFarEndLineIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates if the data for this
        interval is valid."
    ::= { sonetFarEndLineIntervalEntry 6 }

-- the SONET/SDH Path group

-- this group consists of 2 tables:
-- - the SONET/SDH Path Current Table
-- - the SONET/SDH Path Interval Table


-- the SONET/SDH Path Current Table

-- The SONET/SDH Path
-- current table contains various statistics
-- being collected for the current 15 minute interval.

sonetPathCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetPathCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "The SONET/SDH Path Current table."
::= { sonetPath 1 }

sonetPathCurrentEntry OBJECT-TYPE
    SYNTAX  SonetPathCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "An entry in the SONET/SDH Path Current table."
    INDEX   { ifIndex }
::= { sonetPathCurrentTable 1 }

SonetPathCurrentEntry ::=
    SEQUENCE {



Tesink                      Standards Track                    [Page 37]

RFC 2558                   SONET/SDH Objects                  March 1999


        sonetPathCurrentWidth      INTEGER,
        sonetPathCurrentStatus     Integer32,
        sonetPathCurrentESs        PerfCurrentCount,
        sonetPathCurrentSESs       PerfCurrentCount,
        sonetPathCurrentCVs        PerfCurrentCount,
        sonetPathCurrentUASs       PerfCurrentCount
    }


sonetPathCurrentWidth OBJECT-TYPE
    SYNTAX  INTEGER  {
            sts1(1),
            sts3cSTM1(2),
            sts12cSTM4(3),
            sts24c(4),
            sts48cSTM16(5)
     }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
     "A value that indicates the type of the SONET/SDH
     Path.  For SONET, the assigned types are
     the STS-Nc SPEs, where N = 1, 3, 12, 24, and 48.
     STS-1 is equal to 51.84 Mbps.  For SDH, the assigned
     types are the STM-Nc VCs, where N = 1, 4, and 16."
::= { sonetPathCurrentEntry 1 }

sonetPathCurrentStatus OBJECT-TYPE
    SYNTAX  Integer32 (1..62)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "This variable indicates the
      status of the interface.
      The sonetPathCurrentStatus
      is a bit map represented
      as a sum, therefore,
      it can represent multiple defects
      simultaneously.
      The sonetPathNoDefect should be
      set if and only if
      no other flag is set.

      The various bit positions are:
         1   sonetPathNoDefect
         2   sonetPathSTSLOP
         4   sonetPathSTSAIS
         8   sonetPathSTSRDI



Tesink                      Standards Track                    [Page 38]

RFC 2558                   SONET/SDH Objects                  March 1999


        16   sonetPathUnequipped
        32   sonetPathSignalLabelMismatch"
::= { sonetPathCurrentEntry 2 }

sonetPathCurrentESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of Errored
     Seconds encountered by a SONET/SDH
     Path in the current 15 minute interval."
::= { sonetPathCurrentEntry 3 }

sonetPathCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH Path in the current 15
     minute
     interval."
::= { sonetPathCurrentEntry 4 }

sonetPathCurrentCVs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of Coding
     Violations encountered by a
     SONET/SDH Path in the current 15 minute interval."
::= { sonetPathCurrentEntry 5 }

sonetPathCurrentUASs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Unavailable Seconds
     encountered by a Path in the current
     15 minute interval."
::= { sonetPathCurrentEntry 6 }

-- the SONET/SDH Path Interval Table



Tesink                      Standards Track                    [Page 39]

RFC 2558                   SONET/SDH Objects                  March 1999


-- The SONET/SDH Path Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation.  The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.

sonetPathIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetPathIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "The SONET/SDH Path Interval table."
::= { sonetPath 2 }

sonetPathIntervalEntry OBJECT-TYPE
    SYNTAX  SonetPathIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "An entry in the SONET/SDH Path Interval table."
    INDEX   { ifIndex,
              sonetPathIntervalNumber }
::= { sonetPathIntervalTable 1 }


SonetPathIntervalEntry ::=
    SEQUENCE {
         sonetPathIntervalNumber     Integer32,
         sonetPathIntervalESs        PerfIntervalCount,
         sonetPathIntervalSESs       PerfIntervalCount,
         sonetPathIntervalCVs        PerfIntervalCount,
         sonetPathIntervalUASs       PerfIntervalCount,
         sonetPathIntervalValidData  TruthValue
    }


sonetPathIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "A number between 1 and 96, which identifies the
       interval for which the set of statistics is available.
       The interval identified by 1 is the most recently



Tesink                      Standards Track                    [Page 40]

RFC 2558                   SONET/SDH Objects                  March 1999


       completed 15 minute interval,
       and the interval identified
       by N is the interval immediately preceding the
       one identified
       by N-1."
::= { sonetPathIntervalEntry 1 }

sonetPathIntervalESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Errored Seconds encountered
     by a SONET/SDH Path in a
     particular 15-minute interval
     in the past 24 hours."
::= { sonetPathIntervalEntry 2 }

sonetPathIntervalSESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH Path in
     a particular 15-minute interval
     in the past 24 hours."
::= { sonetPathIntervalEntry 3 }

sonetPathIntervalCVs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of Coding
     Violations encountered by a
     SONET/SDH Path in a particular 15-minute interval
     in the past 24 hours."
::= { sonetPathIntervalEntry 4 }

sonetPathIntervalUASs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of



Tesink                      Standards Track                    [Page 41]

RFC 2558                   SONET/SDH Objects                  March 1999


     Unavailable Seconds
     encountered by a Path in a
     particular 15-minute interval
     in the past 24 hours."
::= { sonetPathIntervalEntry 5 }

sonetPathIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates if the data for this
        interval is valid."
    ::= { sonetPathIntervalEntry 6 }

-- The SONET/SDH Far End Path group

-- This group consists of two tables:
--  - SONET/SDH Far End Path Current Table
--  - SONET/SDH Far End Path Interval Table

-- The SONET/SDH Far End Path Current Table

-- The SONET/SDH Far End Path Current table
-- contains various statistics
-- being collected for the current 15 minute interval.
-- The statistics are collected from
-- the far end block error code
-- (FEBE) within the G1 byte of the Path Overhead.
-- The definitions are the same as described for
-- the near-end information.

sonetFarEndPathCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetFarEndPathCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
         "The SONET/SDH Far End Path Current table."
    ::= { sonetFarEndPath 1 }

sonetFarEndPathCurrentEntry OBJECT-TYPE
    SYNTAX  SonetFarEndPathCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
         "An entry in the SONET/SDH Far End Path Current table."
    INDEX   { ifIndex }
    ::= { sonetFarEndPathCurrentTable 1 }



Tesink                      Standards Track                    [Page 42]

RFC 2558                   SONET/SDH Objects                  March 1999


SonetFarEndPathCurrentEntry ::=
    SEQUENCE {
        sonetFarEndPathCurrentESs       PerfCurrentCount,
        sonetFarEndPathCurrentSESs      PerfCurrentCount,
        sonetFarEndPathCurrentCVs       PerfCurrentCount,
        sonetFarEndPathCurrentUASs      PerfCurrentCount
    }


sonetFarEndPathCurrentESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
         "The counter associated with the number of Far
         End Errored Seconds encountered by a SONET/SDH
         interface in the current 15 minute interval."
    ::= { sonetFarEndPathCurrentEntry 1 }

sonetFarEndPathCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
         "The counter associated with the number of
         Far End Severely Errored Seconds
         encountered by a SONET/SDH Path
         interface in the current 15 minute
         interval."
    ::= { sonetFarEndPathCurrentEntry 2 }

sonetFarEndPathCurrentCVs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
         "The counter associated with the number of
         Far End Coding Violations reported via
         the far end block error count
         encountered by a
         SONET/SDH Path interface in
         the current 15 minute interval."
    ::= { sonetFarEndPathCurrentEntry 3 }

sonetFarEndPathCurrentUASs OBJECT-TYPE
   SYNTAX  PerfCurrentCount
   MAX-ACCESS  read-only
   STATUS  current



Tesink                      Standards Track                    [Page 43]

RFC 2558                   SONET/SDH Objects                  March 1999


   DESCRIPTION
       "The counter associated with the number of
       Far End Unavailable Seconds
       encountered by a
       SONET/SDH Path interface in
       the current 15 minute interval."
   ::= { sonetFarEndPathCurrentEntry 4 }

-- The SONET/SDH Far End Path Interval Table

-- The SONET/SDH Far End Path Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation.  The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.

sonetFarEndPathIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetFarEndPathIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The SONET/SDH Far End Path Interval table."
    ::= { sonetFarEndPath 2 }

sonetFarEndPathIntervalEntry OBJECT-TYPE
    SYNTAX  SonetFarEndPathIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the SONET/SDH Far
       End Path Interval table."
    INDEX   { ifIndex,
              sonetFarEndPathIntervalNumber }
    ::= { sonetFarEndPathIntervalTable 1 }

SonetFarEndPathIntervalEntry ::=
    SEQUENCE {
         sonetFarEndPathIntervalNumber     Integer32,
         sonetFarEndPathIntervalESs        PerfIntervalCount,
         sonetFarEndPathIntervalSESs       PerfIntervalCount,
         sonetFarEndPathIntervalCVs        PerfIntervalCount,
         sonetFarEndPathIntervalUASs       PerfIntervalCount,
         sonetFarEndPathIntervalValidData  TruthValue
    }



Tesink                      Standards Track                    [Page 44]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetFarEndPathIntervalNumber OBJECT-TYPE
   SYNTAX  Integer32 (1..96)
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
        "A number between 1 and 96, which identifies the
        interval for which the set of statistics is available.
        The interval identified by 1 is the most recently
        completed 15 minute interval,
        and the interval identified
        by N is the interval immediately preceding the
        one identified
        by N-1."
   ::= { sonetFarEndPathIntervalEntry 1 }

sonetFarEndPathIntervalESs OBJECT-TYPE
   SYNTAX  PerfIntervalCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
        "The counter associated with the number of
        Far End Errored Seconds encountered
        by a SONET/SDH Path interface in a
        particular 15-minute interval
        in the past 24 hours."
   ::= { sonetFarEndPathIntervalEntry 2 }

sonetFarEndPathIntervalSESs OBJECT-TYPE
   SYNTAX  PerfIntervalCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
        "The counter associated with the number of
        Far End Severely Errored Seconds
        encountered by a SONET/SDH Path interface
        in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetFarEndPathIntervalEntry 3 }

sonetFarEndPathIntervalCVs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
         "The counter associated with the number of
         Far End Coding Violations reported via
         the far end block error count
         encountered by a



Tesink                      Standards Track                    [Page 45]

RFC 2558                   SONET/SDH Objects                  March 1999


         SONET/SDH Path interface
         in a particular 15-minute interval
         in the past 24 hours."
    ::= { sonetFarEndPathIntervalEntry 4 }

sonetFarEndPathIntervalUASs OBJECT-TYPE
   SYNTAX  PerfIntervalCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
       "The counter associated with the number of
       Far End Unavailable Seconds
       encountered by a
       SONET/SDH Path interface in
       a particular 15-minute interval
       in the past 24 hours."
   ::= { sonetFarEndPathIntervalEntry 5 }

sonetFarEndPathIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates if the data for this
        interval is valid."
    ::= { sonetFarEndPathIntervalEntry 6 }

-- the SONET/SDH Virtual Tributary group

-- this group consists of 2 tables:
-- - the SONET/SDH VT Current Table
-- - the SONET/SDH VT Interval Table

-- For SDH signals, virtual tributaries are
-- called VCs instead of VTs

-- A VT1.5 = VC11
-- A VT2 = VC12
-- A VT3 = none
-- A VT6 = VC3


-- the SONET/SDH VT Current Table

-- The SONET/SDH VT current table
-- contains various statistics
-- being collected for the
-- current 15 minute interval.



Tesink                      Standards Track                    [Page 46]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetVTCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetVTCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "The SONET/SDH VT Current table."
::= { sonetVT 1 }

sonetVTCurrentEntry OBJECT-TYPE
    SYNTAX  SonetVTCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "An entry in the SONET/SDH VT Current table."
    INDEX   { ifIndex }
::= { sonetVTCurrentTable 1 }

SonetVTCurrentEntry ::=
    SEQUENCE {
        sonetVTCurrentWidth      INTEGER,
        sonetVTCurrentStatus     Integer32,
        sonetVTCurrentESs        PerfCurrentCount,
        sonetVTCurrentSESs       PerfCurrentCount,
        sonetVTCurrentCVs        PerfCurrentCount,
        sonetVTCurrentUASs       PerfCurrentCount
    }

sonetVTCurrentWidth OBJECT-TYPE
    SYNTAX  INTEGER {
            vtWidth15VC11(1),
            vtWidth2VC12(2),
            vtWidth3(3),
            vtWidth6VC2(4),
            vtWidth6c(5)
         }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "A value that indicates the type of the SONET
     VT and SDH VC.  Assigned widths are
     VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
::= { sonetVTCurrentEntry 1 }

sonetVTCurrentStatus OBJECT-TYPE
    SYNTAX  Integer32 (1..126)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION



Tesink                      Standards Track                    [Page 47]

RFC 2558                   SONET/SDH Objects                  March 1999


      "This variable indicates the
      status of the interface.
      The sonetVTCurrentStatus
      is a bit map represented
      as a sum, therefore,
      it can represent multiple defects
      and failures
      simultaneously.
      The sonetVTNoDefect should be
      set if and only if
      no other flag is set.

      The various bit positions are:
         1   sonetVTNoDefect
         2   sonetVTLOP
         4   sonetVTPathAIS
         8   sonetVTPathRDI
        16   sonetVTPathRFI
        32   sonetVTUnequipped
        64   sonetVTSignalLabelMismatch"
::= { sonetVTCurrentEntry 2 }

sonetVTCurrentESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of Errored
     Seconds encountered by a SONET/SDH
     VT in the current 15 minute interval."
::= { sonetVTCurrentEntry 3 }

sonetVTCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH VT in the current 15 minute
     interval."
::= { sonetVTCurrentEntry 4 }

sonetVTCurrentCVs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION



Tesink                      Standards Track                    [Page 48]

RFC 2558                   SONET/SDH Objects                  March 1999


     "The counter associated with the number of Coding
     Violations encountered by a
     SONET/SDH VT in the current 15 minute interval."
::= { sonetVTCurrentEntry 5 }

sonetVTCurrentUASs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Unavailable Seconds
     encountered by a VT in the current
     15 minute interval."
::= { sonetVTCurrentEntry 6 }


-- the SONET/SDH VT Interval Table

-- The SONET/SDH VT Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation.  The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.

sonetVTIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetVTIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "The SONET/SDH VT Interval table."
::= { sonetVT 2 }

sonetVTIntervalEntry OBJECT-TYPE
    SYNTAX  SonetVTIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
     "An entry in the SONET/SDH VT Interval table."
    INDEX   { ifIndex,
              sonetVTIntervalNumber }
::= { sonetVTIntervalTable 1 }

SonetVTIntervalEntry ::=



Tesink                      Standards Track                    [Page 49]

RFC 2558                   SONET/SDH Objects                  March 1999


    SEQUENCE {
        sonetVTIntervalNumber     Integer32,
        sonetVTIntervalESs        PerfIntervalCount,
        sonetVTIntervalSESs       PerfIntervalCount,
        sonetVTIntervalCVs        PerfIntervalCount,
        sonetVTIntervalUASs       PerfIntervalCount,
        sonetVTIntervalValidData  TruthValue
    }

sonetVTIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
      "A number between 1 and 96, which identifies the
      interval for which the set of statistics is available.
      The interval identified by 1 is the most recently
      completed 15 minute interval,
      and the interval identified
      by N is the interval immediately preceding the
      one identified
      by N-1."
::= { sonetVTIntervalEntry 1 }

sonetVTIntervalESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Errored Seconds encountered
     by a SONET/SDH VT in a particular 15-minute interval
     in the past 24 hours."
::= { sonetVTIntervalEntry 2 }

sonetVTIntervalSESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Severely Errored Seconds
     encountered by a SONET/SDH VT
     in a particular 15-minute interval
     in the past 24 hours."
::= { sonetVTIntervalEntry 3 }

sonetVTIntervalCVs OBJECT-TYPE



Tesink                      Standards Track                    [Page 50]

RFC 2558                   SONET/SDH Objects                  March 1999


    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of Coding
     Violations encountered by a
     SONET/SDH VT in a particular 15-minute interval
     in the past 24 hours."
::= { sonetVTIntervalEntry 4 }

sonetVTIntervalUASs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "The counter associated with the number of
     Unavailable Seconds
     encountered by a VT in a particular 15-minute interval
     in the past 24 hours."
::= { sonetVTIntervalEntry 5 }

sonetVTIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates if the data for this
        interval is valid."
    ::= { sonetVTIntervalEntry 6 }

-- The SONET/SDH Far End VT group

-- This group consists of two tables:
--    SONET/SDH Far End VT Current Table
--    SONET/SDH Far End VT Interval Table


-- The SONET/SDH Far End VT Current

-- The SONET/SDH Far End VT Current table
-- contains various statistics
-- being collected for the current 15 minute interval.
-- The statistics are collected from
-- the far end block error code
-- (FEBE) within the G1 byte of the VT Overhead.
-- The definitions are the same as described for
-- the near-end information.




Tesink                      Standards Track                    [Page 51]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetFarEndVTCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetFarEndVTCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The SONET/SDH Far End VT Current table."
    ::= { sonetFarEndVT 1 }

sonetFarEndVTCurrentEntry OBJECT-TYPE
    SYNTAX  SonetFarEndVTCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "An entry in the SONET/SDH Far End VT Current table."
    INDEX   { ifIndex }
    ::= { sonetFarEndVTCurrentTable 1 }

SonetFarEndVTCurrentEntry ::=
    SEQUENCE {
        sonetFarEndVTCurrentESs       PerfCurrentCount,
        sonetFarEndVTCurrentSESs      PerfCurrentCount,
        sonetFarEndVTCurrentCVs       PerfCurrentCount,
        sonetFarEndVTCurrentUASs      PerfCurrentCount
    }


sonetFarEndVTCurrentESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The counter associated with the number of Far
        End Errored Seconds encountered by a SONET/SDH
        interface in the current 15 minute interval."
::= { sonetFarEndVTCurrentEntry 1 }

sonetFarEndVTCurrentSESs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The counter associated with the number of
        Far End Severely Errored Seconds
        encountered by a SONET/SDH VT interface
        in the current 15 minute
        interval."
    ::= { sonetFarEndVTCurrentEntry 2 }




Tesink                      Standards Track                    [Page 52]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetFarEndVTCurrentCVs OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The counter associated with the number of
        Far End Coding Violations reported via
        the far end block error count
        encountered by a
        SONET/SDH VT interface
        in the current 15 minute interval."
    ::= { sonetFarEndVTCurrentEntry 3 }

sonetFarEndVTCurrentUASs OBJECT-TYPE
   SYNTAX  PerfCurrentCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
      "The counter associated with the number of
      Far End Unavailable Seconds
      encountered by a
      SONET/SDH VT interface
      in the current 15 minute interval."
   ::= { sonetFarEndVTCurrentEntry 4 }

-- The SONET/SDH Far End VT Interval Table

-- The SONET/SDH Far End VT Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation.  The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.

sonetFarEndVTIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SonetFarEndVTIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The SONET/SDH Far End VT Interval table."
    ::= { sonetFarEndVT 2 }

sonetFarEndVTIntervalEntry OBJECT-TYPE
    SYNTAX  SonetFarEndVTIntervalEntry
    MAX-ACCESS  not-accessible



Tesink                      Standards Track                    [Page 53]

RFC 2558                   SONET/SDH Objects                  March 1999


    STATUS  current
    DESCRIPTION
      "An entry in the SONET/SDH Far
      End VT Interval table."
    INDEX   { ifIndex,
              sonetFarEndVTIntervalNumber }
    ::= { sonetFarEndVTIntervalTable 1 }

SonetFarEndVTIntervalEntry ::=
   SEQUENCE {
         sonetFarEndVTIntervalNumber     Integer32,
         sonetFarEndVTIntervalESs        PerfIntervalCount,
         sonetFarEndVTIntervalSESs       PerfIntervalCount,
         sonetFarEndVTIntervalCVs        PerfIntervalCount,
         sonetFarEndVTIntervalUASs       PerfIntervalCount,
         sonetFarEndVTIntervalValidData  TruthValue
    }

sonetFarEndVTIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "A number between 1 and 96, which identifies the
       interval for which the set of statistics is available.
       The interval identified by 1 is the most recently
       completed 15 minute interval,
       and the interval identified
       by N is the interval immediately preceding the
       one identified
       by N-1."
    ::= { sonetFarEndVTIntervalEntry 1 }

sonetFarEndVTIntervalESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
          "The counter associated with the number of
          Far End Errored Seconds encountered
          by a SONET/SDH VT interface
          in a particular 15-minute interval
          in the past 24 hours."
   ::= { sonetFarEndVTIntervalEntry 2 }

sonetFarEndVTIntervalSESs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only



Tesink                      Standards Track                    [Page 54]

RFC 2558                   SONET/SDH Objects                  March 1999


    STATUS  current
    DESCRIPTION
          "The counter associated with the number of
          Far End Severely Errored Seconds
          encountered by a SONET/SDH VT interface
          in a particular 15-minute interval
          in the past 24 hours."
    ::= { sonetFarEndVTIntervalEntry 3 }

sonetFarEndVTIntervalCVs OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
         "The counter associated with the number of
         Far End Coding Violations reported via
         the far end block error count
         encountered by a
         SONET/SDH VT interface in a
         particular 15-minute interval
         in the past 24 hours."
    ::= { sonetFarEndVTIntervalEntry 4 }

sonetFarEndVTIntervalUASs OBJECT-TYPE
   SYNTAX  PerfIntervalCount
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
       "The counter associated with the number of
       Far End Unavailable Seconds
       encountered by a
       SONET/SDH VT interface in a
       particular 15-minute interval
       in the past 24 hours."
   ::= { sonetFarEndVTIntervalEntry 5 }

sonetFarEndVTIntervalValidData OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This variable indicates if the data for this
        interval is valid."
    ::= { sonetFarEndVTIntervalEntry 6 }

-- conformance information

sonetConformance OBJECT IDENTIFIER ::= { sonetMIB 4 }



Tesink                      Standards Track                    [Page 55]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetGroups      OBJECT IDENTIFIER ::= { sonetConformance 1 }
sonetCompliances OBJECT IDENTIFIER ::= { sonetConformance 2 }

-- deprecated compliance statement

sonetCompliance MODULE-COMPLIANCE
    STATUS  deprecated
    DESCRIPTION
            "The compliance statement for SONET/SDH interfaces."

    MODULE  -- this module
        MANDATORY-GROUPS { sonetMediumStuff, sonetSectionStuff }

        GROUP       sonetLineStuff
        DESCRIPTION
            "Implementation of this group is mandatory for all
             SONET/SDH systems that terminate SONET/SDH Lines,
             Paths or Virtual Tributaries."

        GROUP       sonetFarEndLineStuff
        DESCRIPTION
            "Implementation of this group is optional for all
             SONET/SDH systems that terminate SONET/SDH Lines,
             Paths or Virtual Tributaries, and that
             provide for a far end block error (FEBE)
             information at the SONET/SDH Line Layer."

        GROUP       sonetPathStuff
        DESCRIPTION
            "Implementation of this group is mandatory for all
             SONET/SDH systems that terminate SONET/SDH
             Paths or Virtual Tributaries."

        OBJECT      sonetPathCurrentWidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        GROUP       sonetFarEndPathStuff
        DESCRIPTION
            "Implementation of this group is optional for all
             SONET/SDH systems that terminate SONET/SDH
             Paths or Virtual Tributaries, and that process
             Far End information."

        GROUP       sonetVTStuff
        DESCRIPTION
            "Implementation of this group is mandatory for all



Tesink                      Standards Track                    [Page 56]

RFC 2558                   SONET/SDH Objects                  March 1999


             SONET/SDH systems that terminate SONET/SDH Virtual
             Tributaries."

        OBJECT      sonetVTCurrentWidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        GROUP       sonetFarEndVTStuff
        DESCRIPTION
            "Implementation of this group is optional for all
             SONET/SDH systems that terminate the SONET/SDH
             floating Virtual Tributaries, and that process
             Far End information."

    ::= { sonetCompliances 1 }


-- current compliance statements

sonetCompliance2 MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
            "The compliance statement for SONET/SDH interfaces."

    MODULE  -- this module
        MANDATORY-GROUPS { sonetMediumStuff2, sonetSectionStuff2 }

        OBJECT      sonetMediumType
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        OBJECT      sonetMediumLineCoding
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        OBJECT      sonetMediumLineType
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        OBJECT      sonetMediumCircuitIdentifier
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."




Tesink                      Standards Track                    [Page 57]

RFC 2558                   SONET/SDH Objects                  March 1999


        OBJECT      sonetMediumLoopbackConfig
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        OBJECT      sonetSESthresholdSet
        MIN-ACCESS  read-only
        DESCRIPTION
          "Write access is not required, and only one
          of the enumerated values need be supported."

        GROUP       sonetLineStuff2
        DESCRIPTION
            "Implementation of this group is mandatory for all
             SONET/SDH systems that terminate SONET/SDH Lines,
             Paths or Virtual Tributaries."

        GROUP       sonetFarEndLineStuff2
        DESCRIPTION
            "Implementation of this group is optional for all
             SONET/SDH systems that terminate SONET/SDH Lines,
             Paths or Virtual Tributaries, and that
             provide for a far end block error (FEBE)
             information at the SONET/SDH Line Layer."

        GROUP       sonetPathStuff2
        DESCRIPTION
            "Implementation of this group is mandatory for all
             SONET/SDH systems that terminate SONET/SDH
             Paths or Virtual Tributaries."

        OBJECT      sonetPathCurrentWidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        GROUP       sonetFarEndPathStuff2
        DESCRIPTION
            "Implementation of this group is optional for all
             SONET/SDH systems that terminate SONET/SDH
             Paths or Virtual Tributaries, and that process
             Far End information."

        GROUP       sonetVTStuff2
        DESCRIPTION
            "Implementation of this group is mandatory for all
             SONET/SDH systems that terminate SONET/SDH Virtual
             Tributaries."



Tesink                      Standards Track                    [Page 58]

RFC 2558                   SONET/SDH Objects                  March 1999


        OBJECT      sonetVTCurrentWidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "Write access is not required."

        GROUP       sonetFarEndVTStuff2
        DESCRIPTION
            "Implementation of this group is optional for all
             SONET/SDH systems that terminate the SONET/SDH
             floating Virtual Tributaries, and that process
             Far End information."

    ::= { sonetCompliances 2 }

-- units of conformance

-- deprecated groups

sonetMediumStuff    OBJECT-GROUP
    OBJECTS { sonetMediumType,
              sonetMediumTimeElapsed,
              sonetMediumValidIntervals,
              sonetMediumLineCoding,
              sonetMediumLineType,
              sonetMediumCircuitIdentifier }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing configuration
            information applicable to all SONET/SDH interfaces."
    ::= { sonetGroups 1 }

sonetSectionStuff    OBJECT-GROUP
    OBJECTS { sonetSectionCurrentStatus,
              sonetSectionCurrentESs,
              sonetSectionCurrentSESs,
              sonetSectionCurrentSEFSs,
              sonetSectionCurrentCVs,
              sonetSectionIntervalESs,
              sonetSectionIntervalSESs,
              sonetSectionIntervalSEFSs,
              sonetSectionIntervalCVs
 }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Section interfaces."
    ::= { sonetGroups 2 }




Tesink                      Standards Track                    [Page 59]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetLineStuff    OBJECT-GROUP
    OBJECTS { sonetLineCurrentStatus,
              sonetLineCurrentESs,
              sonetLineCurrentSESs,
              sonetLineCurrentCVs,
              sonetLineCurrentUASs,
              sonetLineIntervalESs,
              sonetLineIntervalSESs,
              sonetLineIntervalCVs,
              sonetLineIntervalUASs }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Line interfaces."
    ::= { sonetGroups 3 }

sonetFarEndLineStuff    OBJECT-GROUP
    OBJECTS { sonetFarEndLineCurrentESs,
              sonetFarEndLineCurrentSESs,
              sonetFarEndLineCurrentCVs,
              sonetFarEndLineCurrentUASs,
              sonetFarEndLineIntervalESs,
              sonetFarEndLineIntervalSESs,
              sonetFarEndLineIntervalCVs,
              sonetFarEndLineIntervalUASs }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Line interfaces,
            and maintaining Line Far End information."
    ::= { sonetGroups 4 }

sonetPathStuff    OBJECT-GROUP
    OBJECTS { sonetPathCurrentWidth,
              sonetPathCurrentStatus,
              sonetPathCurrentESs,
              sonetPathCurrentSESs,
              sonetPathCurrentCVs,
              sonetPathCurrentUASs,
              sonetPathIntervalESs,
              sonetPathIntervalSESs,
              sonetPathIntervalCVs,
              sonetPathIntervalUASs }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Path interfaces."
    ::= { sonetGroups 5 }



Tesink                      Standards Track                    [Page 60]

RFC 2558                   SONET/SDH Objects                  March 1999


sonetFarEndPathStuff    OBJECT-GROUP
    OBJECTS { sonetFarEndPathCurrentESs,
              sonetFarEndPathCurrentSESs,
              sonetFarEndPathCurrentCVs,
              sonetFarEndPathCurrentUASs,
              sonetFarEndPathIntervalESs,
              sonetFarEndPathIntervalSESs,
              sonetFarEndPathIntervalCVs,
              sonetFarEndPathIntervalUASs }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Path interfaces,
            and maintaining Path Far End information."
    ::= { sonetGroups 6 }

sonetVTStuff    OBJECT-GROUP
    OBJECTS { sonetVTCurrentWidth,
              sonetVTCurrentStatus,
              sonetVTCurrentESs,
              sonetVTCurrentSESs,
              sonetVTCurrentCVs,
              sonetVTCurrentUASs,
              sonetVTIntervalESs,
              sonetVTIntervalSESs,
              sonetVTIntervalCVs,
              sonetVTIntervalUASs }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH VT interfaces."
    ::= { sonetGroups 7 }

sonetFarEndVTStuff    OBJECT-GROUP
    OBJECTS { sonetFarEndVTCurrentESs,
              sonetFarEndVTCurrentSESs,
              sonetFarEndVTCurrentCVs,
              sonetFarEndVTCurrentUASs,
              sonetFarEndVTIntervalESs,
              sonetFarEndVTIntervalSESs,
              sonetFarEndVTIntervalCVs,
              sonetFarEndVTIntervalUASs }
    STATUS  deprecated
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH VT interfaces,
            and maintaining VT Far End information."
    ::= { sonetGroups 8 }



Tesink                      Standards Track                    [Page 61]

RFC 2558                   SONET/SDH Objects                  March 1999


-- current groups

sonetMediumStuff2    OBJECT-GROUP
    OBJECTS { sonetMediumType,
              sonetMediumTimeElapsed,
              sonetMediumValidIntervals,
              sonetMediumLineCoding,
              sonetMediumLineType,
              sonetMediumCircuitIdentifier,
              sonetMediumInvalidIntervals,
              sonetMediumLoopbackConfig,
              sonetSESthresholdSet }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing configuration
            information applicable to all SONET/SDH interfaces."
    ::= { sonetGroups 9 }

sonetSectionStuff2    OBJECT-GROUP
    OBJECTS { sonetSectionCurrentStatus,
              sonetSectionCurrentESs,
              sonetSectionCurrentSESs,
              sonetSectionCurrentSEFSs,
              sonetSectionCurrentCVs,
              sonetSectionIntervalESs,
              sonetSectionIntervalSESs,
              sonetSectionIntervalSEFSs,
              sonetSectionIntervalCVs,
              sonetSectionIntervalValidData }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Section interfaces."
    ::= { sonetGroups 10 }

sonetLineStuff2    OBJECT-GROUP
    OBJECTS { sonetLineCurrentStatus,
              sonetLineCurrentESs,
              sonetLineCurrentSESs,
              sonetLineCurrentCVs,
              sonetLineCurrentUASs,
              sonetLineIntervalESs,
              sonetLineIntervalSESs,
              sonetLineIntervalCVs,
              sonetLineIntervalUASs,
              sonetLineIntervalValidData }
    STATUS  current
    DESCRIPTION



Tesink                      Standards Track                    [Page 62]

RFC 2558                   SONET/SDH Objects                  March 1999


            "A collection of objects providing information
            specific to SONET/SDH Line interfaces."
    ::= { sonetGroups 11 }

sonetPathStuff2    OBJECT-GROUP
    OBJECTS { sonetPathCurrentWidth,
              sonetPathCurrentStatus,
              sonetPathCurrentESs,
              sonetPathCurrentSESs,
              sonetPathCurrentCVs,
              sonetPathCurrentUASs,
              sonetPathIntervalESs,
              sonetPathIntervalSESs,
              sonetPathIntervalCVs,
              sonetPathIntervalUASs,
              sonetPathIntervalValidData }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Path interfaces."
    ::= { sonetGroups 12 }

sonetVTStuff2    OBJECT-GROUP
    OBJECTS { sonetVTCurrentWidth,
              sonetVTCurrentStatus,
              sonetVTCurrentESs,
              sonetVTCurrentSESs,
              sonetVTCurrentCVs,
              sonetVTCurrentUASs,
              sonetVTIntervalESs,
              sonetVTIntervalSESs,
              sonetVTIntervalCVs,
              sonetVTIntervalUASs,
              sonetVTIntervalValidData }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH VT interfaces."
    ::= { sonetGroups 13 }

sonetFarEndLineStuff2    OBJECT-GROUP
    OBJECTS { sonetFarEndLineCurrentESs,
              sonetFarEndLineCurrentSESs,
              sonetFarEndLineCurrentCVs,
              sonetFarEndLineCurrentUASs,
              sonetFarEndLineIntervalESs,
              sonetFarEndLineIntervalSESs,
              sonetFarEndLineIntervalCVs,



Tesink                      Standards Track                    [Page 63]

RFC 2558                   SONET/SDH Objects                  March 1999


              sonetFarEndLineIntervalUASs,
              sonetFarEndLineIntervalValidData }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Line interfaces,
            and maintaining Line Far End information."
    ::= { sonetGroups 14 }

sonetFarEndPathStuff2    OBJECT-GROUP
    OBJECTS { sonetFarEndPathCurrentESs,
              sonetFarEndPathCurrentSESs,
              sonetFarEndPathCurrentCVs,
              sonetFarEndPathCurrentUASs,
              sonetFarEndPathIntervalESs,
              sonetFarEndPathIntervalSESs,
              sonetFarEndPathIntervalCVs,
              sonetFarEndPathIntervalUASs,
              sonetFarEndPathIntervalValidData }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH Path interfaces,
            and maintaining Path Far End information."
    ::= { sonetGroups 15 }

sonetFarEndVTStuff2    OBJECT-GROUP
    OBJECTS { sonetFarEndVTCurrentESs,
              sonetFarEndVTCurrentSESs,
              sonetFarEndVTCurrentCVs,
              sonetFarEndVTCurrentUASs,
              sonetFarEndVTIntervalESs,
              sonetFarEndVTIntervalSESs,
              sonetFarEndVTIntervalCVs,
              sonetFarEndVTIntervalUASs,
              sonetFarEndVTIntervalValidData }
    STATUS  current
    DESCRIPTION
            "A collection of objects providing information
            specific to SONET/SDH VT interfaces,
            and maintaining VT Far End information."
    ::= { sonetGroups 16 }


END






Tesink                      Standards Track                    [Page 64]

RFC 2558                   SONET/SDH Objects                  March 1999


5.  Acknowledgments

   This specification is a product of the AToM MIB Working Group.  The
   author would like to acknowledge Mike Heard for his many valuable
   contributions to this memo.

6.  Security Considerations

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write and/or read-create.  Such
   objects may be considered sensitive or vulnerable in some network
   environments. The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.

   The managed objects in this MIB contain sensitive information since,
   collectively, they allow influencing of interfaces in SONET/SDH
   equipment or networks and provide information of their configuration.

   It is thus important to control even GET access to these objects and
   possibly to even encrypt the values of these object when sending them
   over the network via SNMP. Not all versions of SNMP provide features
   for such a secure environment.

   SNMPv1 by itself is not a secure environment. Even if the network
   itself is secure (for example by using IPSec), even then, there is no
   control as to who on the secure network is allowed to access and
   GET/SET (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementers consider the security
   features as provided by the SNMPv3 framework. Specifically, the use
   of the User-based Security Model RFC 2274 [12] and the View-based
   Access Control Model RFC 2275 [15] is recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to the objects only to those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.












Tesink                      Standards Track                    [Page 65]

RFC 2558                   SONET/SDH Objects                  March 1999


7.  References

   [1]  Harrington, D., Presuhn, R. and B. Wijnen, "An tecture for
        Describing SNMP Management Frameworks", RFC 2271, January 1998.

   [2]  Rose, M. and K. McCloghrie, "Structure and Identification of
        Management Information for TCP/IP-based Internets", STD 16, RFC
        1155, May 1990.

   [3]  Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
        RFC 1212, March 1991.

   [4]  Rose, M., "A Convention for Defining Traps for use with the
        SNMP", RFC 1215, March 1991

   [5]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.  and S.
        Waldbusser, "Structure of Management Information for Version 2
        of the Simple Network Management Protocol (SNMPv2)", RFC 1902,
        January 1996.

   [6]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.  and S.
        Waldbusser, "Textual Conventions for Version 2 of the Simple
        Network Management Protocol (SNMPv2)", RFC 1903, January 1996.

   [7]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.  and S.
        Waldbusser, "Conformance Statements for Version 2 of the Simple
        Network Management Protocol (SNMPv2)", RFC 1904, January 1996.

   [8]  Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
        Network Management Protocol", STD 15, RFC 1157, May 1990.

   [9]  SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.  and S.
        Waldbusser, "Introduction to Community-based SNMPv2", RFC 1901,
        January 1996.

   [10] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.  and S.
        Waldbusser, "Transport Mappings for Version 2 of the Simple
        Network Management Protocol (SNMPv2)", RFC 1906, January 1996.

   [11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
        Processing and Dispatching for the Simple Network Management
        Protocol (SNMP)", RFC 2272, January 1998.

   [12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
        for version 3 of the Simple Network Management Protocol
        (SNMPv3)", RFC 2274, January 1998.





Tesink                      Standards Track                    [Page 66]

RFC 2558                   SONET/SDH Objects                  March 1999


   [13] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M.  and S.
        Waldbusser, "Protocol Operations for Version 2 of the Simple
        Network Management Protocol (SNMPv2)", RFC 1905, January 1996.

   [14] Levi, D., Meyer, P. and B. Stewart, SNMPv3 Applications", RFC
        2273, January 1998.

   [15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
        Control Model (VACM) for the Simple Network Management Protocol
        (SNMP)", RFC 2275, January 1998.

   [16] McCloghrie, K. and M. Rose, "Management Information Base for
        Network Management of TCP/IP-based internets - MIB-II", STD 17,
        RFC 1213, March 1991.

   [17] Information processing systems - Open Systems Interconnection -
        Specification of Abstract Syntax Notation One (ASN.1),
        International Organization for Standardization.  International
        Standard 8824, (December, 1987).

   [18] Information processing systems - Open Systems Interconnection -
        Specification of Basic Encoding Rules for Abstract Notation One
        (ASN.1), International Organization for Standardization.
        International Standard 8825, (December, 1987).

   [19] American National Standard for Telecommunications - Digital
        Hierarchy - Optical Interface Rates and Formats Specification,
        ANSI T1.105-1988.

   [20] American National Standard for Telecommunications - Digital
        Hierarchy - Optical Interface Rates and Formats Specification,
        ANSI T1.105-1991.

   [21] American National Standard for Telecommunications - Digital
        Hierarchy - Optical Interface Specification (Single-Mode), ANSI
        T1.106-1988.

   [22] Draft American National Standard for Telecommunications -
        Digital Hierarchy - Layer 1 In-Service Digital Transmission
        Performance Monitoring, T1M1.3/93-005R2, July 1993.

   [23] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",
        RFC 2233, November 1997.

   [24] Fowler, D., "Definitions of Managed Objects for the DS3/E3
        Interface Type", RFC 2496, January 1999.





Tesink                      Standards Track                    [Page 67]

RFC 2558                   SONET/SDH Objects                  March 1999


   [25] Fowler, D., "Definitions of Managed Objects for the DS1, E1, DS2
        and E2 Interface Types", RFC 2495, January 1999.

   [26] CCITT Recommendation G.707, "Synchronous Digital Hierarchy Bit
        Rates", June 1992.

   [27] CCITT Recommendation G.708, "Network Node Interface for the
        Synchronous Digital Hierarchy", June 1992.

   [28] CCITT Recommendation G.709, "Synchronous Multiplexing
        Structure", June 1992.

   [29] CCITT Recommendation G.783, "Characteristics of Synchronous
        Digital Hierarchy (SDH) Multiplexing Equipment Functional
        Blocks", November 1992.

   [30] Brown, T. and K. Tesink, "Definitions of Managed Objects for the
        SONET/SDH Interface Type", RFC 1595, March 1994.

   [31] American National Standard for Telecommunications - Digital
        Hierarchy - Layer 1 In-Service Digital Transmission Performance
        Monitoring, ANSI T1.231-1993, September 1993.

   [32] Bellcore TR-NWT-000253, Issue 1, "Synchronous Optical Network
        (SONET) Transport Systems:  Common Generic Criteria", December
        1991.

   [33] ITU Recommendation G.826, "Error Performance Parameters and
        Objectives for International Constant Bit Rate Digital Paths at
        or above Primary Rate", September 1995 (COM 13-R57E).

   [34] Bellcore GR-253-CORE, Issue 2, "Synchronous Optical Network
        (SONET) Transport Systems Common Generic Criteria", December
        1995.

   [35] American National Standard for Telecommunications - Digital
        Hierarchy - Layer 1 In-Service Digital Transmission Performance
        Monitoring, ANSI T1.231-1997, September 1997.

   [36] Tesink, K., " Textual Conventions for MIB Modules Using
        Performance History Based on 15 Minute Intervals", RFC 2493,
        January 1999.









Tesink                      Standards Track                    [Page 68]

RFC 2558                   SONET/SDH Objects                  March 1999


8.  Author's Address

   Kaj Tesink
   Telcordia Technologies
   331 Newman Springs Road
   P.O. Box 7020
   Red Bank, NJ  07701-7020

   Phone: (732) 758-5254
   EMail: kaj@research.telcordia.com

9.  Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.



















Tesink                      Standards Track                    [Page 69]

RFC 2558                   SONET/SDH Objects                  March 1999


Appendix A:  The delay-line approach to statistics collection.

   According to ANSI T1.231 unavailable time begins at the onset of 10
   contiguous severely errored seconds -- that is, unavailable time
   starts with the first of the 10 contiguous SESs -- and while an
   interface is deemed unavailable all counters for that interface are
   frozen except for the UAS count.  Since changes in the signal state
   lag the data to which they apply by 10 seconds, an implementation
   which wishes to avoid making retroactive adjustments to the counts
   must pass the the one-second statistics through a 10-second delay
   line prior to updating any counters.  That can be done by performing
   the following steps at the end of each one second interval.

   i)   Read near/far end line and path CV counts and alarm status flags
        from the hardware.

   ii)  Accumulate the CV counts for the preceding second and compare
        them to the ES and SES threshold for the layer in question.
        Update the signal state and shift the one-second CV counts and
        ES/SES flags into the 10-element delay line.  Note that far-end
        one-second statistics are to be flagged as "absent" during any
        second in which there is an incoming defect at the layer in
        question or at any lower layer.

   iii) Update the current interval statistics using the signal state
        from the previous update cycle and the one-second CV counts and
        ES/SES flags shifted out of the 10-element delay line.

   This procedure guarantees that the statistical counters will be
   correctly updated at all times, although they lag real time by 10
   seconds.  It is illustrated in the figure below.  At the end of each
   15 minutes interval the current interval counts are transferred to
   the  most recent interval entry and each interval is shifted up by
   one position, with the oldest being discarded if necessary in order
   to make room.  The current interval counts then start over from zero.
   Note, however, that the signal state calculation does not start anew
   at each interval boundary;  rather, signal state information is
   retained across interval boundaries.

   +--------------------------------------------------------------+
   |          READ COUNTERS & STATUS INFO FROM HARDWARE           |
   |                                                              |
   |LOS OOF/ SECT  LINE LINE LINE LINE  PATH PATH PATH PATH PATH  |
   |    LOF   CV    AIS  CV   RDI FEBE   AIS  LOP  CV   RDI  CV   |
   +--------------------------------------------------------------+
     |   |     |     |    |    |   |      |    |    |    |    |
     |   |     |     |    |    |   |      |    |    |    |    |
     V   V     V     V    V    V   V      V    V    V    V    V



Tesink                      Standards Track                    [Page 70]

RFC 2558                   SONET/SDH Objects                  March 1999


   +--------------------------------------------------------------+
   | ACCUM ONE-SEC STATS, CHK ERR THRESHOLDS, & UPDT SIGNAL STATE |
   |                                                              |
   |                                                              |
   |                  NEAR END/FAR END       NEAR END/FAR END     |
   |SECT SECT SECT  LINE LINE LINE  LINE   PATH PATH PATH  PATH   |
   |CV   ES   SES    CV   ES   SES AVA/UNA  CV   ES   SES AVA/UNA |
   +--------------------------------------------------------------+
     |    |    |      |    |    |     |      |    |    |     |
     |    |    |      |    |    |     |      |    |    |     |
     V    V    V      V    V    V     |      V    V    V     |
   +-------------+  +-------------+   |    +-------------+   |
   |ONE-SEC DELAY|  |ONE-SEC DELAY|   |    |ONE-SEC DELAY|   |
   | (1 OF 10)   |  | (1 OF 10)   |   |    | (1 OF 10)   |   |
   |CV   ES   SES|  |CV   ES   SES|   |    |CV   ES   SES|   |
   +-------------+  +-------------+   |    +-------------+   |
     |    |    |      |    |    |     |      |    |    |     |
     /    /    /      /    /    /     /      /    /    /     /
     /    /    /      /    /    /     /      /    /    /     /
     |    |    |      |    |    |     |      |    |    |     |
     V    V    V      V    V    V     |      V    V    V     |
   +-------------+  +-------------+   |    +-------------+   |
   |ONE-SEC DELAY|  |ONE-SEC DELAY|   |    |ONE-SEC DELAY|   |
   | (10 OF 10)  |  | (10 OF 10)  |   |    | (10 OF 10)  |   |
   |CV   ES   SES|  |CV   ES   SES|   |    |CV   ES   SES|   |
   +-------------+  +-------------+   |    +-------------+   |
     |    |    |      |    |    |     |      |    |    |     |
     |    |    |      |    |    |     |      |    |    |     |
     V    V    V      V    V    V     V      V    V    V     V
   +--------------------------------------------------------------+
   |              UPDATE STATISTICS COUNTERS                      |
   |                                                              |
   |                   NEAR END/FAR END       NEAR END/FAR END    |
   |   SECTION               LINE                   PATH          |
   | CV ES EFS SES   CV ES EFS SES AS UAS   CV ES EFS SES AS UAS  |
   +--------------------------------------------------------------+

   Note that if such a procedure is adopted there is no current interval
   data for the first ten seconds after a system comes up.
   noSuchInstance must be returned if a management station attempts to
   access the current interval counters during this time.

   It is an implementation-specific matter whether an agent assumes that
   the initial state of the interface is available or unavailable.







Tesink                      Standards Track                    [Page 71]

RFC 2558                   SONET/SDH Objects                  March 1999


Appendix B - RFC1595 SES interpretation

   This appendix contains the values for x for the Section, Line, Path,
   and VT Layers as used in [22][30][32].

                  Value for x for SONET/SDH Section SES Definition

             Rate            x               Minimum Bit Error Rate
             =======================================================
             OC-1             9                      1.5 x 10^-7
             OC-3            16                        1 x 10^-7
             OC-9            47                        1 x 10^-7
             OC-12           63                        1 x 10^-7
             OC-18           94                        1 x 10^-7
             OC-24          125                        1 x 10^-7
             OC-36          187                        1 x 10^-7
             OC-48          249                        1 x 10^-7


                  Value for x for SONET/SDH Line SES Definition

             Rate            x               Minimum Bit Error Rate
             =======================================================
             OC-1            12                       2 x 10^-7
             OC-3            32                       2 x 10^-7
             OC-9            47                       2 x 10^-7
             OC-12          124                       2 x 10^-7
             OC-18          186                       2 x 10^-7
             OC-24          248                       2 x 10^-7
             OC-36          370                       2 x 10^-7
             OC-48          494                       2 x 10^-7


                  Value for x for SONET/SDH STS-Path SES Definition

             Rate            x               Minimum Bit Error Rate
             =======================================================
             STS-1            9                       1.5 x 10^-7
             STS-3           16                         1 x 10^-7












Tesink                      Standards Track                    [Page 72]

RFC 2558                   SONET/SDH Objects                  March 1999


                  Value for x for SONET/SDH VT-Path SES Definition

             Rate            x               Minimum Bit Error Rate
             =======================================================
             VT1.5            4                       2 x 10^-6
             VT2              6                       2 x 10^-6
             VT3              8                       2 x 10^-6
             VT6             14                       2 x 10^-6











































Tesink                      Standards Track                    [Page 73]

RFC 2558                   SONET/SDH Objects                  March 1999


Full Copyright Statement

   Copyright (C) The Internet Society (1999).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
























Tesink                      Standards Track                    [Page 74]