Network Working Group                                        K. Rehbehn
Request for Comments: 2954                              Megisto Systems
Obsoletes: 1604                                               D. Fowler
Category: Standards Track                              Syndesis Limited
                                                           October 2000


                     Definitions of Managed Objects
                        for Frame Relay Service

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

Abstract

   This memo defines an extension to the Management Information Base
   (MIB) for use with network management protocols in Transmission
   Control Protocol/Internet Protocol-based (TCP/IP) internets.  In
   particular, it defines objects for managing the frame relay service.

   This document obsoletes RFC 1604.

Table of Contents

   1 The SNMP Management Framework ................................   2
   2 Overview .....................................................   3
   2.1 Scope of MIB ...............................................   3
   2.2 Transiting Multiple Frame Relay Networks ...................   5
   2.3 Access Control .............................................   5
   2.4 Frame Relay Service MIB Terminology ........................   6
   2.5 Relation to Other MIBs .....................................   8
   2.5.1 System Group .............................................   8
   2.5.2 Interfaces Table (ifTable, ifXtable) .....................   8
   2.5.3 Stack Table for DS1/E1 Environment .......................  12
   2.5.4 Stack Table for V.35 Environments ........................  14
   2.5.5 The Frame Relay/ATM PVC Service Interworking MIB .........  14
   2.6 Textual Convention Change ..................................  15
   3 Object Definitions ...........................................  15
   3.1 The Frame Relay Service Logical Port .......................  17



Rehbehn & Fowler            Standards Track                     [Page 1]

RFC 2954                Frame Relay Service MIB             October 2000


   3.2 Frame Relay Management VC Signaling ........................  22
   3.3 Frame Relay PVC End-Points .................................  32
   3.4 Frame Relay PVC Connections ................................  45
   3.5 Frame Relay Accounting .....................................  53
   3.6 Frame Relay Network Service Notifications ..................  56
   3.7 Conformance Information ....................................  57
   4 Acknowledgments ..............................................  67
   5 References ...................................................  67
   6 Security Considerations ......................................  69
   7 Authors' Addresses ...........................................  70
   APPENDIX A Update Information ..................................  71
   Intellectual Property Rights ...................................  75
   Full Copyright Statement .......................................  76

1.  The SNMP Management Framework

   The SNMP Management Framework presently consists of five major
   components:

   o  An overall architecture, described in RFC 2571 [1].

   o  Mechanisms for describing and naming objects and events for the
      purpose of management.  The first version of this Structure of
      Management Information (SMI) is called SMIv1 and described in STD
      16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4].  The
      second version, called SMIv2, is described in STD 58, RFC 2578
      [5], STD 58, RFC 2579 [6] and STD 58, RFC 2580 [7].

   o  Message protocols for transferring management information.  The
      first version of the SNMP message protocol is called SNMPv1 and
      described in STD 15, RFC 1157 [8].  A second version of the SNMP
      message protocol, which is not an Internet standards track
      protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC
      1906 [10].  The third version of the message protocol is called
      SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574
      [12].

   o  Protocol operations for accessing management information.  The
      first set of protocol operations and associated PDU formats is
      described in STD 15, RFC 1157 [8].  A second set of protocol
      operations and associated PDU formats is described in RFC 1905
      [13].

   o  A set of fundamental applications described in RFC 2573 [14] and
      the view-based access control mechanism described in RFC 2575
      [15].





Rehbehn & Fowler            Standards Track                     [Page 2]

RFC 2954                Frame Relay Service MIB             October 2000


   A more detailed introduction to the current SNMP Management Framework
   can be found in RFC 2570 [16].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the mechanisms defined in the SMI.

   This memo specifies a MIB module that is compliant to the SMIv2.  A
   MIB conforming to the SMIv1 can be produced through the appropriate
   translations.  The resulting translated MIB must be semantically
   equivalent, except where objects or events are omitted because no
   translation is possible (use of Counter64).  Some machine readable
   information in SMIv2 will be converted into textual descriptions in
   SMIv1 during the translation process.  However, this loss of machine
   readable information is not considered to change the semantics of the
   MIB.

2.  Overview

   These objects are used to manage a frame relay Service.  At present,
   this applies to the following value of the ifType variable in the
   IF-MIB [26]:

        frameRelayService (44)

   This section provides an overview and background of how to use this
   MIB and other potential MIBs to manage a frame relay service.

2.1.  Scope of MIB

   The Frame Relay Service MIB supports Customer Network Management
   (CNM) of a frame relay network service.  Through the use of this and
   other related MIBs, a frame relay service customer's NMS can monitor
   the customer's UNI/NNI logical ports and PVCs.  It provides customers
   with access to configuration data, performance monitoring
   information, and fault detection for the delivered frame relay
   service.  As an option, an SNMP agent supporting the Frame Relay
   Service MIB may allow customer-initiated PVC management operations
   such as creation, deletion, modification, activation, and
   deactivation of individual PVCs.  However, internal aspects of the
   network (e.g., switching elements, line cards, and network routing
   tables) are beyond the scope of this MIB.

   The Frame Relay Service MIB models all interfaces and PVCs delivered
   by a frame relay service within a single virtual SNMP system for the
   purpose of comprehensively representing the customer's frame relay
   service.  The customer's interfaces and PVCs may physically exist on
   one or more devices within the network topology.  An SNMP agent



Rehbehn & Fowler            Standards Track                     [Page 3]

RFC 2954                Frame Relay Service MIB             October 2000


   providing support for the Frame Relay Service MIB as well as other
   appropriate MIBs to model a single virtual frame relay network
   service is referred to as a Frame Relay Service (FRS) agent.
   Internal communication mechanisms between the FRS agent and
   individual devices within the frame relay network delivering the
   service are implementation specific and beyond the scope of this MIB.

   The customer's NMS will typically access the SNMP agent implementing
   the Frame Relay Service MIB over a frame relay permanent virtual
   connection (PVC).  SNMP access over a frame relay PVC is achieved
   through the use of SNMP over UDP over IP encapsulated in Frame Relay
   according to STD 55, RFC2427 and ITU X.36 Annex D [23].  Alternate
   access mechanisms and SNMP agent implementations are possible.

   This MIB will NOT be implemented on user equipment (e.g., DTE).  Such
   devices are managed using the Frame Relay DTE MIB (RFC2115[18]).
   However, concentrators may use the Frame Relay Service MIB instead of
   the Frame Relay DTE MIB.

   This MIB does not define managed objects for the physical layer.
   Existing physical layer MIBs (e.g., DS1 MIB) and Interface MIB will
   be used as needed in FRS Agent implementations.

   This MIB supports frame relay PVCs.  This MIB may be extended at a
   later time to handle frame relay SVCs.

   A switch implementation may support this MIB for the purpose of
   configuration and control of the frame relay service beyond the scope
   of traditional customer network management applications.  A number of
   objects (e.g. frLportTypeAdmin) support administrative actions that
   impact the operation of frame relay switch equipment in the network.
   This is reflected in the differences between the two MIB compliance
   modules:

      o  the frame relay service compliance module
         (frnetservCompliance), and

      o  the frame relay switch compliance module
         (frnetSwitchCompliance).

   The frame relay service compliance module does not support the
   administrative control objects used for switch management.









Rehbehn & Fowler            Standards Track                     [Page 4]

RFC 2954                Frame Relay Service MIB             October 2000


2.2.  Transiting Multiple Frame Relay Networks

   This MIB is only used to manage a single frame relay service offering
   from one network service provider.  Therefore, if a customer PVC
   traverses multiple networks, then the customer must poll a different
   FRS agent within each frame relay network to retrieve the end-to-end
   view of service.

   Figure 1 illustrates a customer ("User B") NMS accessing FRS agents
   in three different frame relay networks (I, J, and K).

                +-------------------------------------+
                | Customer Network Management Station |
                |            (SNMP based)             |
                +-------------------------------------+
                    ^              ^               ^
                    |              |               |
                    |              |               |
           UNI      |      NNI     |       NNI     |       UNI
            |       ^       |      ^        |      ^
            | +-----------+ | +-----------+ | +-----------+ |
            | |           | | |           | | |           | |
Originating | |   FR      | | |   FR      | | |   FR      | |Terminating
 +--------+ | | Network I | | | Network J | | | Network K | | +--------+
 |        | | |           | | |           | | |           | | |        |
 |        |---|           |---|           |---|           |---| User B |
 |        | | |           | | |           | | |           | | |        |
 |     ////////////////////////////////////////////////////////////    |
 |        | | |           | | |           | | |           | | |        |
 +--------+ | +-----------+ | +-----------+ | +-----------+ | +--------+
            |               |               |               |
            |               |               |               |
            | PVC Segment 1 | PVC Segment 2 | PVC Segment 3 |
            |<------------->|<------------->|<------------->|
            |                                               |
            |              Multi-network PVC                |
            |<--------------------------------------------->|
            |  NNI = Network-to Network Interface           |
               UNI = User-to-Network Interface

                         Figure 1, Multi-network PVC

2.3.  Access Control

   A frame relay network is shared amongst many frame relay subscribers.
   Each subscriber will only have access to their information (e.g.,
   information with respect to their interfaces and PVCs).  The FRS agent
   should provide instance level granularity for MIB views.



Rehbehn & Fowler            Standards Track                     [Page 5]

RFC 2954                Frame Relay Service MIB             October 2000


2.4.  Frame Relay Service MIB Terminology

   Access Channel - An access channel generically refers to the DS1/E1
   or DS3/E3-based UNI access channel or NNI access channel across which
   frame relay data transits.  An access channel is the access pathway
   for a single stream of user data.

   Within a given DS1 line, an access channel can denote any one of the
   following:

   o  Unchannelized DS1 - the entire DS1 line is considered an access
      channel. Each access channel is comprised of 24 DS0 time slots.

   o  Channelized DS1 - an access channel is any one of 24 channels.
      Each access channel is comprised of a single DS0 time slot.

   o  Fractional DS1 - an access channel is a grouping of NxDS0 time
      slots (NX56/64 Kbps, where N = 1-23 DS0 Time slots per Fractional
      DS1 Access Channel) that may be assigned in consecutive or
      non-consecutive order.

   Within a given E1 line, a channel can denote any one of the following:

   o  Unchannelized E1 - the entire E1 line is considered a single
      access channel.  Each access channel is comprised of 31 E1 time
      slots.

   o  Channelized E1 - an access channel is any one of 31 channels.
      Each access channel is comprised of a single E1 time slot.

   o  Fractional E1 - an access channel is a grouping of N E1 time
      slots (NX64 Kbps, where N = 1-30 E1 time slots per FE1 access
      channel) that may be assigned in consecutive or non-consecutive
      order.

   Within a given unformatted line, the entire unformatted line is
   considered an access channel. Examples include RS-232, V.35, V.36 and
   X.21 (non-switched), and unframed E1 (G.703 without G.704).

   Access Rate - The data rate of the access channel, expressed in
   bits/second.  The speed of the user access channel determines how
   rapidly the end user can inject data into the network.

   Bc - The Committed Burst Size (Bc) is the maximum amount of
   subscriber data (expressed in bits) that the network agrees to
   transfer, under normal conditions, during a time interval Tc.





Rehbehn & Fowler            Standards Track                     [Page 6]

RFC 2954                Frame Relay Service MIB             October 2000


   Be - The Excess Burst Size (Be) is the maximum amount of subscriber
   data (expressed in bits) in excess of Bc that the network will
   attempt to deliver during the time interval Tc.  This data (Be) is
   delivered in general with a lower probability than Bc.

   CIR - The Committed Information Rate (CIR) is the subscriber data
   rate (expressed in bits/second) that the network commits to deliver
   under normal network conditions.  CIR is averaged over the time
   interval Tc (CIR = Bc/Tc).

   DLCI - Data Link Connection Identifier

   Logical Port - This term is used to model the frame relay "interface"
   on a device.

   NNI - Network to Network Interface

   Permanent Virtual Connection (PVC) - A virtual connection that has
   its end-points and bearer capabilities defined at subscription time.

   Time slot (E1) - An octet within the 256-bit information field in
   each E1 frame is defined as a time slot.  Time slots are position
   sensitive within the 256-bit information field.  Fractional E1 service
   is provided in contiguous or non-contiguous time slot increments.

   Time slot (DS0) - An octet within the 192-bit information field in
   each DS1 frame is defined as a time slot.  Time slots are position
   sensitive within the 192-bit information field. Fractional DS1
   service is provided in contiguous or non-contiguous time slot
   increments.

   UNI - User to Network Interface

   N391 - Full status (status of all PVCs) polling counter

   N392 - Error threshold

   N393 - Monitored events count

   T391 - Link integrity verification polling timer

   T392 - Polling verification timer

   nT3 - Status enquiry timer

   nN3 - Maximum status enquiry counter





Rehbehn & Fowler            Standards Track                     [Page 7]

RFC 2954                Frame Relay Service MIB             October 2000


2.5.  Relation to Other MIBs

2.5.1.  System Group

   Use the System Group of the SNMPv2-MIB [27] to describe the Frame
   Relay Service (FRS) agent.  The FRS agent may be monitoring many
   frame relay devices in one network.  The System Group does not
   describe frame relay devices monitored by the FRS agent.

   sysDescr:  ASCII string describing the FRS agent.
              Can be up to 255 characters long. This field is
              generally used to indicate the network providers
              identification and type of service offered.

   sysObjectID:  Unique OBJECT IDENTIFIER (OID) for the
                 FRS agent.

   sysUpTime:  Clock in the FRS agent; TimeTicks
               in 1/100s of a second.  Elapsed type since
               the FRS agent came on line.

   sysContact:  Contact for the FRS agent.
                ASCII string of up to 255 characters.

   sysName:  Domain name of the FRS agent, for example,
             acme.com

   sysLocation:  Location of the FRS agent.
                 ASCII string of up to 255 characters.

   sysServices:  Services of the managed device.  The value "2",
                 which implies that
                 the frame relay network is providing
                 a subnetwork level service, is recommended.

2.5.2.  Interfaces Table (ifTable, ifXtable)

   This specifies how the Interfaces Group defined in the IF MIB [26]
   shall be used for the management of frame relay based interfaces, and
   in conjunction with the Frame Relay Service MIB module.  This memo
   assumes the interpretation of the evolution of the Interfaces group
   to be in accordance with: "The interfaces table (ifTable) contains
   information on the managed resource's interfaces.  Each sub-layer
   below the internetwork layer of a network interface is considered an
   interface."  Thus, the ifTable allows the following frame relay-based
   interfaces to be represented as table entries:





Rehbehn & Fowler            Standards Track                     [Page 8]

RFC 2954                Frame Relay Service MIB             October 2000


   -  Frame relay interfaces in equipment (e.g., switches, routers or
      networks) supporting frame relay.  This level is concerned with
      generic frame counts and not with individual virtual connections.

   In accordance with the guidelines of ifTable, frame counts per
   virtual connection are not covered by ifTable, and are considered
   interface specific and covered in the Frame Relay Service MIB module.
   In order to interrelate the ifEntries properly, the Interfaces Stack
   Group shall be supported.

   Some specific interpretations of ifTable for frame relay follow.

   Object                 Use for the generic Frame Relay layer
   ======                 =============================================
   ifIndex                Each frame relay port is represented by an
                          ifEntry.

   ifDescr                Description of the frame relay interface.
                          ASCII string describing the UNI/NNI logical
                          port.  Can be up to 255 characters long.

   ifType                 The value allocated for Frame Relay Service
                          is equal to 44.

   ifMtu                  Set to maximum frame size in octets for this
                          frame relay logical port.

   ifSpeed                Peak bandwidth in bits per second available
                          for use. This could be the speed of the
                          logical port and not the access rate. Actual
                          user information transfer rate (i.e., access
                          rate) of the UNI or NNI logical port in bits
                          per second (this is not the clocking speed).
                          For example, it is 1,536,000 bits per second
                          for a DS1-based UNI/NNI logical port and
                          1,984,000 bits per second for an E1-based
                          UNI/NNI logical port.

   ifPhysAddress          The primary address for this logical port
                          assigned by the frame relay interface
                          provider.  An octet string of zero length if
                          no address is used for this logical port.

   ifAdminStatus          The desired administrative status of the
                          frame relay logical port.






Rehbehn & Fowler            Standards Track                     [Page 9]

RFC 2954                Frame Relay Service MIB             October 2000


   ifOperStatus           The current operational status of the Frame
                          Relay UNI or NNI logical port.

   ifLastChange           The value of sysUptime at the last
                          re-initialization of the logical port.  The
                          value of sysUpTime at the time the logical
                          port entered its current operational state.
                          If the current state was entered prior to the
                          last re-initialization of the local network
                          management subsystem, then this object
                          contains a zero value.

   ifInOctets             The number of received octets.  This counter
                          only counts octets from the beginning of the
                          frame relay header field to the end of user
                          data.

   ifInUcastPkts          The number of received unerrored, unicast
                          frames.

   ifInDiscards           The number of received frames discarded.
                          Specifically, frames discarded due to ingress
                          buffer congestion and traffic policing.

   ifInErrors             The number of received frames that are
                          discarded because of an error. Specifically,
                          frames that are too long or too short, frames
                          that are not a multiple of 8 bits in length,
                          frames with an invalid or unrecognized DLCI,
                          frames with an abort sequence, frames with
                          improper flag delimitation, and frame that
                          fail FCS.

   ifInUnknownProtos      The number of packets discarded because of an
                          unknown or unsupported protocol.  For Frame
                          Relay Service interfaces, this counter will
                          always be zero.

   ifOutOctets            The number of transmitted octets.  This
                          counter only counts octets from the beginning
                          of the frame relay header field to the end of
                          user data.

   ifOutUcastpkts         The number of unerrored, unicast frames sent.

   ifOutDiscards          The number of frames discarded in the egress
                          direction. Possible reasons are as follows:
                          policing, congestion.



Rehbehn & Fowler            Standards Track                    [Page 10]

RFC 2954                Frame Relay Service MIB             October 2000


   ifOutErrors            The number of frames discarded in the egress
                          direction because of an error. Specifically,
                          frames that are aborted due to a transmitter
                          underrun.

   ifName                 This variable is not applicable for Frame
                          Relay Service interfaces, therefore, this
                          variable contains a zero-length string.

   ifInMulticastPkts      The number of received unerrored, multicast
                          frames.

   ifInBroadcastPkts      This variable is not applicable for Frame
                          Relay Service interfaces, therefore, this
                          counter is always zero.

   ifOutMulticastPkts     The number of sent unerrored, multicast
                          frames.

   ifOutBroadcastPkts     This variable is not applicable for Frame
                          Relay Service interfaces, therefore, this
                          counter is always zero.

   ifHCInOctets           Only used for DS3-based (and greater) Frame
                          Relay logical ports.  The number of received
                          octets.  This counter only counts octets
                          from the beginning of the frame relay header
                          field to the end of user data.

   ifHCOutOctets          Only used for DS3-based (and greater) Frame
                          Relay logical ports.  The number of
                          transmitted octets.  This counter only counts
                          octets from the beginning of the frame relay
                          header field to the end of user data.

   ifLinkUpDownTrapEnable Set to true(1).  It is recommended that the
                          underlying physical layer notifications be
                          disabled since both are not required.
                          Notifications are enabled at the frame relay
                          service layer specifically because PVC
                          notifications are not to be sent if the frame
                          relay interface fails. Without a
                          linkUp/linkDown notification, the management
                          station would receive no notification of the
                          failure.






Rehbehn & Fowler            Standards Track                    [Page 11]

RFC 2954                Frame Relay Service MIB             October 2000


   ifHighSpeed            Set to the user data rate of the frame relay
                          logical port in millions of bits per second.
                          If the user data rate is less than 1 Mbps,
                          then this value is zero.

   ifPromiscuousMode      Set to false(2).

   ifConnectorPresent     Set to false(2).

   Frame relay network service interfaces support the Interface Stack
   Group.  Frame relay network service interfaces do not support any
   other groups or objects in the Interfaces group of the IF MIB.

2.5.3.  Stack Table for DS1/E1 Environment

   This section describes by example how to use ifStackTable to
   represent the relationship of frame relay service to ds0 and
   ds0Bundles with ds1 interfaces [20].

   Example: A frame relay service is being carried on 4 ds0s of a ds1.

     +---------------------+
     | Frame Relay Service |
     +---------------------+
                |
     +---------------------+
     | ds0Bundle           |
     +---------------------+
       |     |     |     |
     +---+ +---+ +---+ +---+
     |ds0| |ds0| |ds0| |ds0|
     +---+ +---+ +---+ +---+
       |     |     |     |
     +---------------------+
     | ds1                 |
     +---------------------+

   The assignment of the index values could for example be:

        ifIndex  Description
        1        FrameRelayService (type 44)
        2        ds0Bundle         (type 82)
        3        ds0 #1            (type 81)
        4        ds0 #2            (type 81)
        5        ds0 #3            (type 81)
        6        ds0 #4            (type 81)
        7        ds1               (type 18)




Rehbehn & Fowler            Standards Track                    [Page 12]

RFC 2954                Frame Relay Service MIB             October 2000


   The ifStackTable is then used to show the relationships between the
   various interfaces.

        ifStackTable Entries

        HigherLayer   LowerLayer
        0             1
        1             2
        2             3
        2             4
        2             5
        2             6
        3             7
        4             7
        5             7
        6             7
        7             0

   In the case where the frame relay service is using a single ds0, then
   the ds0Bundle is not required.

     +---------------------+
     | Frame Relay Service |
     +---------------------+
       |
     +---+
     |ds0|
     +---+
       |
     +---------------------+
     | ds1                 |
     +---------------------+

   The assignment of the index values could for example be:

        ifIndex  Description
        1        FrameRelayService (type 44)
        2        ds0               (type 81)
        3        ds1               (type 18)

   The ifStackTable is then used to show the relationships between the
   various interfaces.









Rehbehn & Fowler            Standards Track                    [Page 13]

RFC 2954                Frame Relay Service MIB             October 2000


        ifStackTable Entries

        HigherLayer   LowerLayer
        0             1
        1             2
        2             3
        3             0

2.5.4.  Stack Table for V.35 Environments

   This section describes by example how to use ifStackTable to
   represent the relationship of frame relay service with V.35
   interfaces.

        +---------------------+
        | Frame Relay Service |
        +---------------------+
                   |
        +---------------------+
        | v35                 |
        +---------------------+

   An example of index values in this case could be:

           ifIndex  Description
           1        FrameRelayService (type 44)
           2        v35               (type 33)

   Note type 33 (RS232-like MIB) is used instead of type 45 (V.35).  V35
   does not pertain to this environment.

   The ifStackTable is then used to show the relationships between the
   various interfaces.

           ifStackTable Entries

           HigherLayer   LowerLayer
           0             1
           1             2
           2             0

2.5.5.  The Frame Relay/ATM PVC Service Interworking MIB

   Connections between two frame relay endpoints are represented with an
   entry in the frPVCConnectTable of this MIB.  Both endpoints are
   represented with rows in the frPVCEndptTable.  The
   frPVCEndptConnectIdentifier object of each endpoint points to the
   frPVCConnectTable cross-connect table row for the connection.



Rehbehn & Fowler            Standards Track                    [Page 14]

RFC 2954                Frame Relay Service MIB             October 2000


   In contrast, a connection that spans frame relay and ATM endpoints is
   represented with an entry in the frAtmIwfConnectionTable of the
   FR/ATM PVC Service Interworking MIB defined in [28].

   In the case of an inter-worked connection, the
   frPVCEndptConnectIdentifier object is set to zero.  Instead, the
   frPVCEndptAtmIwfConnIndex object is set to the index of the FR/ATM
   IWF cross-connect table row.

   The frame relay PVC cross-connect table (frPVCConnectTable) does not
   contain an entry for the FR/ATM inter-worked connection.

2.6.  Textual Convention Change

   Version 1 of the Frame Relay Service MIB contains MIB objects defined
   with the DisplayString textual convention.  In version 2 of this MIB,
   the syntax for these objects has been updated to use the (now
   preferred) SnmpAdminString textual convention.  The new TC provides
   support for a greater variety of international character sets.

   The working group realizes that this change is not strictly supported
   by SMIv2.  In our judgment, the alternative of deprecating the old
   objects and defining new objects would have a more adverse impact on
   backward compatibility and interoperability, given the particular
   semantics of these objects.

3.  Object Definitions

FRNETSERV-MIB DEFINITIONS ::= BEGIN

IMPORTS
              MODULE-IDENTITY, OBJECT-TYPE,
              NOTIFICATION-TYPE, transmission,
              Counter32, Integer32             FROM SNMPv2-SMI
              TimeStamp, RowStatus             FROM SNMPv2-TC
              MODULE-COMPLIANCE, OBJECT-GROUP,
              NOTIFICATION-GROUP               FROM SNMPv2-CONF
              InterfaceIndex, ifIndex          FROM IF-MIB
              SnmpAdminString                  FROM SNMP-FRAMEWORK-MIB;

        frnetservMIB MODULE-IDENTITY
            LAST-UPDATED "200009280000Z" -- September 28, 2000
            ORGANIZATION "IETF Frame Relay Service MIB Working Group"
            CONTACT-INFO
                "WG Charter:
                   http://www.ietf.org/html.charters/frnetmib-charter
                 WG-email:
                   frnetmib@sunroof.eng.sun.com



Rehbehn & Fowler            Standards Track                    [Page 15]

RFC 2954                Frame Relay Service MIB             October 2000


                 Subscribe:
                   frnetmib-request@sunroof.eng.sun.com
                 Email Archive:
                   ftp://ftp.ietf.org/ietf-mail-archive/frnetmib

                 Chair:      Andy Malis
                             Vivace Networks, Inc.
                 Email:      Andy.Malis@vivacenetworks.com

                 WG editor:  Kenneth Rehbehn
                             Megisto Systems, Inc.
                 Email:      krehbehn@megisto.com

                 Co-author:  David Fowler
                             Syndesis Limited,
                 EMail:      fowler@syndesis.com"

            DESCRIPTION
                 "The MIB module to describe generic objects for
                  Frame Relay Network Service."

            --
            -- Revision History
            --
            REVISION "200009280000Z"
            DESCRIPTION
                 "Published as RFC 2954.

                 The major new features of this revision include:

                     o  Support for read-write capability to
                        provision switch components providing service,

                     o  Support for cross-connection via a frame relay
                        to ATM service interworking function,

                     o  Support for frame relay fragmentation,

                     o  Additional frame counters to track frame
                        loss.

                 Refer to Appendix A for a comprehensive list of
                 changes since RFC 1604."

            REVISION "199311161200Z"
            DESCRIPTION
                 "Published as RFC 1604."
            ::= { transmission 44 }



Rehbehn & Fowler            Standards Track                    [Page 16]

RFC 2954                Frame Relay Service MIB             October 2000


            frnetservObjects
                OBJECT IDENTIFIER ::= { frnetservMIB 1 }

            frnetservTraps
                OBJECT IDENTIFIER ::= { frnetservMIB 2 }

            frnetservTrapsPrefix
                OBJECT IDENTIFIER ::= { frnetservTraps 0 }

        --
        -- The Frame Relay Service Logical Port
        --
        frLportTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF FrLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay Logical Port Information table is
                    an interface-specific addendum to the generic
                    ifTable of the Interface MIB."
            ::= { frnetservObjects 1 }

        frLportEntry OBJECT-TYPE
            SYNTAX      FrLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Logical Port
                    Information table."
            INDEX   {   ifIndex }
            ::= { frLportTable 1 }

        FrLportEntry ::=
            SEQUENCE {
                frLportNumPlan            INTEGER,
                frLportContact            SnmpAdminString,
                frLportLocation           SnmpAdminString,
                frLportType               INTEGER,
                frLportAddrDLCILen        INTEGER,
                frLportVCSigProtocol      INTEGER,
                frLportVCSigPointer       OBJECT IDENTIFIER,
                frLportDLCIIndexValue     Integer32,
                frLportTypeAdmin          INTEGER,
                frLportVCSigProtocolAdmin INTEGER,
                frLportFragControl        INTEGER,
                frLportFragSize           Integer32
        }




Rehbehn & Fowler            Standards Track                    [Page 17]

RFC 2954                Frame Relay Service MIB             October 2000


        frLportNumPlan OBJECT-TYPE
            SYNTAX      INTEGER {
                        other(1),
                        e164(2),
                        x121(3),
                        none(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the network
                    address numbering plan for this UNI/NNI logical
                    port. The network address is the object
                    ifPhysAddress. The value none(4) implies that
                    there is no ifPhysAddress.  The FRS agent will
                    return an octet string of zero length for
                    ifPhysAddress.  The value other(1) means that an
                    address has been assigned to this interface, but
                    the numbering plan is not enumerated here."
            REFERENCE   "E.164 [29]
                         X.121 [30]"
            ::= { frLportEntry 1 }

        frLportContact  OBJECT-TYPE
            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the network
                    contact for this UNI/NNI logical port."
            ::= { frLportEntry 2 }

        frLportLocation OBJECT-TYPE
            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the frame
                    relay network location for this UNI/NNI logical
                    port."
            ::= { frLportEntry 3 }

        frLportType     OBJECT-TYPE
            SYNTAX      INTEGER {
                        uni(1),
                        nni(2)
                        }
            MAX-ACCESS  read-only



Rehbehn & Fowler            Standards Track                    [Page 18]

RFC 2954                Frame Relay Service MIB             October 2000


            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the type of
                    network interface for this logical port."
            ::= { frLportEntry 4 }

        frLportAddrDLCILen OBJECT-TYPE
            SYNTAX      INTEGER {
                        twoOctets10Bits(1),
                        threeOctets10Bits(2),
                        threeOctets16Bits(3),
                        fourOctets17Bits(4),
                        fourOctets23Bits(5)
                        }
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Q.922
                    Address field length and DLCI length for this
                    UNI/NNI logical port."
            REFERENCE   "Q.922 [25]"
            ::= { frLportEntry 5 }

        frLportVCSigProtocol OBJECT-TYPE
            SYNTAX      INTEGER {
                        none(1),
                        lmi(2),
                        ansiT1617D(3),
                        ansiT1617B(4),
                        ccittQ933A(5)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Local
                    In-Channel Signaling Protocol that is used for
                    this frame relay UNI/NNI logical port.

                    none(1):        Interface does not use a PVC
                                    signaling protocol

                    lmi(2):         Interface operates the Stratacom/
                                    Nortel/DEC Local Management
                                    Interface Specification protocol

                    ansiT1617D(3):  Interface operates the ANSI T1.617
                                    Annex D PVC status protocol



Rehbehn & Fowler            Standards Track                    [Page 19]

RFC 2954                Frame Relay Service MIB             October 2000


                      ansiT1617B(4):  Interface operates the ANSI
T1.617
                                      Annex B procedures

                      ccittQ933A(5):  Interface operates the ITU Q.933
                                      Annex A PVC status protocol"
              REFERENCE   "LMI [24]
                           T1.617 Annex D [17],
                           Q.933 Annex A [22]"
              ::= { frLportEntry 6 }

        frLportVCSigPointer OBJECT-TYPE
            SYNTAX      OBJECT IDENTIFIER
            MAX-ACCESS  read-only
            STATUS      deprecated
            DESCRIPTION
                    "The value of this object is used as a pointer to
                    the table that contains the Local In-Channel
                    Signaling Protocol parameters and errors for this
                    UNI/NNI logical port.

                    This object has been deprecated to reflect the
                    fact that the local in-channel signaling
                    parameters are accessed from a single table
                    (frMgtVCSigTable) that includes parameters for all
                    possible signaling protocols.  Early design
                    anticipated multiple tables, one for each
                    signaling protocol."
            ::= { frLportEntry 7 }

        frLportDLCIIndexValue OBJECT-TYPE
            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object contains a hint to be used for
                    frPVCEndptDLCIIndex when creating entries in the
                    frPVCEndptTable.  The SYNTAX of this object
                    matches the SYNTAX of the frPVCEndptDLCIIndex - an
                    object that is restricted to legal Q.922 DLCI
                    values for the size of the address field.

                    The value 0 indicates that no unassigned entries
                    are available.

                    To obtain the frPVCEndptDLCIIndex value for a new
                    entry, the manager issues a management protocol
                    retrieval operation to obtain the current value of



Rehbehn & Fowler            Standards Track                    [Page 20]

RFC 2954                Frame Relay Service MIB             October 2000


                    this object.  After each retrieval, the agent must
                    modify the value to the next unassigned index to
                    prevent assignment of the same value to multiple
                    management systems.

                    A management system should repeat the read to
                    obtain a new value should an attempt to create the
                    new row using the previously returned hint fail."
            REFERENCE   "Q.922 [25]"
            ::= { frLportEntry 8 }

        frLportTypeAdmin   OBJECT-TYPE
            SYNTAX      INTEGER {
                        uni(1),
                        nni(2)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object desired identifies the
                    type of network interface for this logical port."
              ::= { frLportEntry 9 }

        frLportVCSigProtocolAdmin OBJECT-TYPE
            SYNTAX      INTEGER {
                        none(1),
                        lmi(2),
                        ansiT1617D(3),
                        ansiT1617B(4),
                        ccittQ933A(5)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Local In-Channel Signaling Protocol that is used
                    for this frame relay UNI/NNI logical port.  This
                    value must be made the active protocol as soon as
                    possible on the device.

                    Refer to frLportVCSigProtocol for a description of
                    each signaling protocol choices."
            REFERENCE   "LMI [24]
                         T1.617 Annex D [17],
                         Q.933 Annex A [22]"
            ::= { frLportEntry 10 }

        frLportFragControl OBJECT-TYPE



Rehbehn & Fowler            Standards Track                    [Page 21]

RFC 2954                Frame Relay Service MIB             October 2000


            SYNTAX      INTEGER {
                        on(1),
                        off(2)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "This object controls the transmission and
                    reception of fragmentation frames for this UNI or
                    NNI interface.

                    on(1)   Frames are fragmented using the interface
                            fragmentation format
                            Note:  The customer side of the interface
                            must also be configured to fragment
                            frames.

                    off(2)  Frames are not fragmented using the
                            interface fragmentation format."
            REFERENCE   "FRF.12 [21]"
            DEFVAL { off }
            ::= { frLportEntry 11 }

        frLportFragSize OBJECT-TYPE
            SYNTAX      Integer32 (0..4096)
            UNITS       "Octets"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object is the size in octets of
                    the maximum size of each fragment to be sent when
                    fragmenting.  This object is only used by the
                    fragmentation transmitter, and the two sides of
                    the interface may differ.  The fragment size
                    includes the octets for the frame relay header,
                    the UI octet, the NLPID, the fragmentation header,
                    and the fragment payload. If frLportFragControl is
                    set to off, this value should be zero."
            REFERENCE   "FRF.12 [21]"
            DEFVAL { 0 }
            ::= { frLportEntry 12 }

        --
        -- Frame Relay Management VC Signaling
        --

        frMgtVCSigTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF FrMgtVCSigEntry



Rehbehn & Fowler            Standards Track                    [Page 22]

RFC 2954                Frame Relay Service MIB             October 2000


            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay Management VC Signaling
                    Parameters and Errors table."
            ::= { frnetservObjects 2 }

        frMgtVCSigEntry OBJECT-TYPE
            SYNTAX      FrMgtVCSigEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Management VC
                    Signaling Parameters Errors table."
            INDEX       { ifIndex }
            ::= { frMgtVCSigTable 1 }

        FrMgtVCSigEntry ::=
            SEQUENCE {
                frMgtVCSigProced             INTEGER,
                frMgtVCSigUserN391           INTEGER,
                frMgtVCSigUserN392           INTEGER,
                frMgtVCSigUserN393           INTEGER,
                frMgtVCSigUserT391           INTEGER,
                frMgtVCSigNetN392            INTEGER,
                frMgtVCSigNetN393            INTEGER,
                frMgtVCSigNetT392            INTEGER,
                frMgtVCSigNetnN4             INTEGER,
                frMgtVCSigNetnT3             INTEGER,
                frMgtVCSigUserLinkRelErrors  Counter32,
                frMgtVCSigUserProtErrors     Counter32,
                frMgtVCSigUserChanInactive   Counter32,
                frMgtVCSigNetLinkRelErrors   Counter32,
                frMgtVCSigNetProtErrors      Counter32,
                frMgtVCSigNetChanInactive    Counter32,
                frMgtVCSigProcedAdmin        INTEGER,
                frMgtVCSigUserN391Admin      INTEGER,
                frMgtVCSigUserN392Admin      INTEGER,
                frMgtVCSigUserN393Admin      INTEGER,
                frMgtVCSigUserT391Admin      INTEGER,
                frMgtVCSigNetN392Admin       INTEGER,
                frMgtVCSigNetN393Admin       INTEGER,
                frMgtVCSigNetT392Admin       INTEGER,
                frMgtVCSigNetnT3Admin        INTEGER
        }

        frMgtVCSigProced OBJECT-TYPE
            SYNTAX      INTEGER {



Rehbehn & Fowler            Standards Track                    [Page 23]

RFC 2954                Frame Relay Service MIB             October 2000


                        u2nnet(1),
                        bidirect(2),
                        u2nuser(3)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the local
                    in-channel signaling procedural role that is used
                    for this UNI/NNI logical port.  Bidirectional
                    procedures implies that both user-side and
                    network-side procedural roles are used.

                    u2nnet(1)   Logical port operates user to network
                                procedure in the role of the network
                                side

                    bidirect(2) Logical port operates the
                                bidirectional procedure (both user
                                and network side roles)

                    u2nuser(3)  Logical port operates user to network
                                procedure in the role of the user
                                side"
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 1 }

        frMgtVCSigUserN391 OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            UNITS       "Polls"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    N391 full status polling cycle value for this
                    UNI/NNI logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated and an
                    attempt to read will result in the noSuchInstance
                    exception response."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 6 }
            ::= { frMgtVCSigEntry 2 }

        frMgtVCSigUserN392 OBJECT-TYPE
            SYNTAX      INTEGER (1..10)



Rehbehn & Fowler            Standards Track                    [Page 24]

RFC 2954                Frame Relay Service MIB             October 2000


            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    N392 error threshold value for this UNI/NNI
                    logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 3 }
            ::= { frMgtVCSigEntry 3 }

        frMgtVCSigUserN393 OBJECT-TYPE
            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    N393 monitored events count value for this UNI/NNI
                    logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 4 }
            ::= { frMgtVCSigEntry 4 }

        frMgtVCSigUserT391 OBJECT-TYPE
            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    T391 link integrity verification polling timer
                    value for this UNI/NNI logical port.  If the
                    logical port is not performing user-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 10 }
            ::= { frMgtVCSigEntry 5 }

        frMgtVCSigNetN392 OBJECT-TYPE
            SYNTAX      INTEGER (1..10)



Rehbehn & Fowler            Standards Track                    [Page 25]

RFC 2954                Frame Relay Service MIB             October 2000


            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side N392 error threshold value (nN2 for LMI) for
                    this UNI/NNI logical port.  If the logical port is
                    not performing network-side procedures, then this
                    object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            DEFVAL { 3 }
            ::= { frMgtVCSigEntry 6 }

        frMgtVCSigNetN393 OBJECT-TYPE
            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side N393 monitored events count value (nN3 for
                    LMI) for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            DEFVAL { 4 }
            ::= { frMgtVCSigEntry 7 }

        frMgtVCSigNetT392 OBJECT-TYPE
            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side T392 polling verification timer value (nT2
                    for LMI)  for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            DEFVAL { 15 }
            ::= { frMgtVCSigEntry 8 }



Rehbehn & Fowler            Standards Track                    [Page 26]

RFC 2954                Frame Relay Service MIB             October 2000


        frMgtVCSigNetnN4 OBJECT-TYPE
            SYNTAX      INTEGER (5..5)
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side nN4 maximum status enquires received value
                    for this UNI/NNI logical port.  If the logical
                    port is not performing network-side procedures or
                    is not performing LMI procedures, then this object
                    is not instantiated.

                    This object applies only to LMI and always has a
                    value of 5."
            REFERENCE   "LMI [24]"
            ::= { frMgtVCSigEntry 9 }

        frMgtVCSigNetnT3 OBJECT-TYPE
            SYNTAX      INTEGER (5 | 10 | 15 | 20 | 25 | 30)
            UNITS       "Seconds"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side nT3 timer (for nN4 status enquires received)
                    value for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures or is not performing LMI procedures,
                    then this object is not instantiated.

                      This object applies only to LMI."
              REFERENCE   "LMI [24]"
              DEFVAL { 20 }
              ::= { frMgtVCSigEntry 10 }

        frMgtVCSigUserLinkRelErrors OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of user-side local in-channel
                    signaling link reliability errors (i.e., non-
                    receipt of Status/Status Enquiry messages or
                    invalid sequence numbers in a Link Integrity
                    Verification Information Element) for this UNI/NNI
                    logical port.  If the logical port is not



Rehbehn & Fowler            Standards Track                    [Page 27]

RFC 2954                Frame Relay Service MIB             October 2000


                    performing user-side procedures, then this object
                    is not instantiated."
            ::= { frMgtVCSigEntry 11 }

        frMgtVCSigUserProtErrors OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of user-side local in-channel
                    signaling protocol errors (i.e., protocol
                    discriminator, unnumbered information, message
                    type, call reference, and mandatory information
                    element errors) for this UNI/NNI logical port. If
                    the logical port is not performing user-side
                    procedures, then this object is not instantiated."
            ::= { frMgtVCSigEntry 12 }

      frMgtVCSigUserChanInactive OBJECT-TYPE
          SYNTAX      Counter32
          UNITS       "Events"
          MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of times the user-side channel was
                    declared inactive (i.e., N392 errors in N393
                    events) for this UNI/NNI logical port. If the
                    logical port is not performing user-side
                    procedures, then this object is not instantiated."
            ::= { frMgtVCSigEntry 13 }

        frMgtVCSigNetLinkRelErrors OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of network-side local in-channel
                    signaling link reliability errors (i.e., non-
                    receipt of Status/Status Enquiry messages or
                    invalid sequence numbers in a Link Integrity
                    Verification Information Element) for this UNI/NNI
                    logical port."
            ::= { frMgtVCSigEntry 14 }

        frMgtVCSigNetProtErrors OBJECT-TYPE
            SYNTAX      Counter32



Rehbehn & Fowler            Standards Track                    [Page 28]

RFC 2954                Frame Relay Service MIB             October 2000


            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of network-side local in-channel
                    signaling protocol errors (i.e., protocol
                    discriminator, message type, call reference, and
                    mandatory information element errors) for this
                    UNI/NNI logical port."
            ::= { frMgtVCSigEntry 15 }

        frMgtVCSigNetChanInactive OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of times the network-side channel was
                    declared inactive (i.e., N392 errors in N393
                    events) for this UNI/NNI logical port."
            ::= { frMgtVCSigEntry 16 }

        frMgtVCSigProcedAdmin OBJECT-TYPE
            SYNTAX      INTEGER {
                        u2nnet(1),
                        bidirect(2),
                        u2nuser(3)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the local
                    in-channel signaling procedural role that is used
                    for this UNI/NNI logical port.  Bidirectional
                    procedures implies that both user-side and
                    network-side procedural roles are used.

                    u2nnet(1)   Logical port operates user to network
                                procedure in the role of the network
                                side

                    bidirect(2) Logical port operates the
                                bidirectional procedure (both user
                                and network side roles)

                    u2nuser(3)  Logical port operates user to network
                                procedure in the role of the user
                                side"



Rehbehn & Fowler            Standards Track                    [Page 29]

RFC 2954                Frame Relay Service MIB             October 2000


            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { u2nnet }
            ::= { frMgtVCSigEntry 17 }

        frMgtVCSigUserN391Admin OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            UNITS       "Polls"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side N391 full status polling cycle value for
                    this UNI/NNI logical port.  If the logical port is
                    not performing user-side (bidirectional)
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 18 }

        frMgtVCSigUserN392Admin OBJECT-TYPE
            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side N392 error threshold value for this
                    UNI/NNI logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 19 }

        frMgtVCSigUserN393Admin OBJECT-TYPE
            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side N393 monitored events count value for
                    this UNI/NNI logical port.  If the logical port is
                    not performing user-side (bidirectional)
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"



Rehbehn & Fowler            Standards Track                    [Page 30]

RFC 2954                Frame Relay Service MIB             October 2000


            ::= { frMgtVCSigEntry 20 }

        frMgtVCSigUserT391Admin OBJECT-TYPE
            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side T391 link integrity verification polling
                    timer value for this UNI/NNI logical port.  If the
                    logical port is not performing user-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 21 }

        frMgtVCSigNetN392Admin OBJECT-TYPE
            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side N392 error threshold value (nN2 for
                    LMI) for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            ::= { frMgtVCSigEntry 22 }

        frMgtVCSigNetN393Admin OBJECT-TYPE
            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side N393 monitored events count value
                    (nN3 for LMI) for this UNI/NNI logical port.  If
                    the logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            ::= { frMgtVCSigEntry 23 }



Rehbehn & Fowler            Standards Track                    [Page 31]

RFC 2954                Frame Relay Service MIB             October 2000


        frMgtVCSigNetT392Admin OBJECT-TYPE
            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side T392 polling verification timer value
                    (nT2 for LMI)  for this UNI/NNI logical port. If
                    the logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            ::= { frMgtVCSigEntry 24 }

        frMgtVCSigNetnT3Admin OBJECT-TYPE
            SYNTAX      INTEGER (5 | 10 | 15 | 20 | 25 | 30)
            UNITS       "Seconds"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side nT3 timer (for nN4 status enquires
                    received) value for this UNI/NNI logical port. If
                    the logical port is not performing network-side
                    procedures or is not performing LMI procedures,
                    then this object is not instantiated.  This object
                    applies only to LMI."
            REFERENCE   "LMI [24]"
            ::= { frMgtVCSigEntry 25 }

        --
        -- Frame Relay PVC End-points
        --

        frPVCEndptTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF FrPVCEndptEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay PVC End-Point table.  This table
                    is used to model a PVC end-point.  This table
                    contains the traffic parameters and statistics for
                    a PVC end-point.

                    This table is used to identify the traffic
                    parameters for a bi-directional PVC segment end-



Rehbehn & Fowler            Standards Track                    [Page 32]

RFC 2954                Frame Relay Service MIB             October 2000


                    point, and it also provides statistics for a PVC
                    segment end-point.

                    A PVC segment end-point is identified by a UNI/NNI
                    logical port index value and DLCI index value.

                    If the frame relay service provider allows the
                    frame relay CNM subscriber to create, modify or
                    delete PVCs using SNMP, then this table is used to
                    identify and reserve the requested traffic
                    parameters of each PVC segment end-point.  The
                    Connection table is used to 'connect' the end-
                    points together.  Not all implementations will
                    support the capability of
                    creating/modifying/deleting PVCs using SNMP as a
                    feature of frame relay CNM service.

                    Uni-directional PVCs are modeled with zero valued
                    traffic parameters in one of the directions (In or
                     Out direction) in this table.

                    To create a PVC, the following procedures shall be
                    followed:

                    1)  Create the entries for the PVC segment
                        endpoints in the frPVCEndptTable by specifying
                        the traffic parameters for the bi-directional
                        PVC segment endpoints. As shown in figure 2, a
                        point-to-point PVC has two endpoints, thus two
                        entries in this table.  Uni-directional PVCs
                        are modeled with zero valued traffic
                        parameters in one direction; all the `In'
                        direction parameters for one frame relay PVC
                        End-point or all the `Out' direction
                        parameters for the other frame relay PVC
                        Endpoint.

                        In    _____________________________  Out
                       >>>>>>|                             |>>>>>>>>
                       ______|    Frame Relay Network      |________
                        Out  |                             |  In
                       <<<<<<|_____________________________|<<<<<<<<
                     Frame Relay                         Frame Relay
                         PVC                                 PVC
                       Endpoint                            Endpoint

                                Figure 2, PVC Terminology




Rehbehn & Fowler            Standards Track                    [Page 33]

RFC 2954                Frame Relay Service MIB             October 2000


                    2)  Go to the Frame Relay Connection Group."
            ::= { frnetservObjects 3 }

        frPVCEndptEntry OBJECT-TYPE
            SYNTAX      FrPVCEndptEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay PVC Endpoint table."
            INDEX   { ifIndex, frPVCEndptDLCIIndex }
            ::= { frPVCEndptTable 1 }

        FrPVCEndptEntry ::=
            SEQUENCE {
                frPVCEndptDLCIIndex            Integer32,
                frPVCEndptInMaxFrameSize       Integer32,
                frPVCEndptInBc                 Integer32,
                frPVCEndptInBe                 Integer32,
                frPVCEndptInCIR                Integer32,
                frPVCEndptOutMaxFrameSize      Integer32,
                frPVCEndptOutBc                Integer32,
                frPVCEndptOutBe                Integer32,
                frPVCEndptOutCIR               Integer32,
                frPVCEndptConnectIdentifier    Integer32,
                frPVCEndptRowStatus            RowStatus,
                frPVCEndptRcvdSigStatus        INTEGER,
                frPVCEndptInFrames             Counter32,
                frPVCEndptOutFrames            Counter32,
                frPVCEndptInDEFrames           Counter32,
                frPVCEndptInExcessFrames       Counter32,
                frPVCEndptOutExcessFrames      Counter32,
                frPVCEndptInDiscards           Counter32,
                frPVCEndptInOctets             Counter32,
                frPVCEndptOutOctets            Counter32,
                frPVCEndptInDiscardsDESet      Counter32,
                frPVCEndptInFramesFECNSet      Counter32,
                frPVCEndptOutFramesFECNSet     Counter32,
                frPVCEndptInFramesBECNSet      Counter32,
                frPVCEndptOutFramesBECNSet     Counter32,
                frPVCEndptInCongDiscards       Counter32,
                frPVCEndptInDECongDiscards     Counter32,
                frPVCEndptOutCongDiscards      Counter32,
                frPVCEndptOutDECongDiscards    Counter32,
                frPVCEndptOutDEFrames          Counter32,
                frPVCEndptAtmIwfConnIndex      Integer32

            }




Rehbehn & Fowler            Standards Track                    [Page 34]

RFC 2954                Frame Relay Service MIB             October 2000


        frPVCEndptDLCIIndex OBJECT-TYPE
            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the DLCI
                    value for this PVC end-point.

                    The values are restricted to the legal range for
                    the size of address field supported by the logical
                    port (frLportAddrDLCILen)."
            REFERENCE   "Q.922 [25]"
            ::= { frPVCEndptEntry 1 }

        frPVCEndptInMaxFrameSize OBJECT-TYPE
            SYNTAX      Integer32 (1..4096)
            UNITS       "Octets"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is the size in octets of
                    the largest frame relay information field for this
                    PVC end-point in the ingress direction (into the
                    frame relay network).  The value of
                    frPVCEndptInMaxFrameSize must be less than or
                    equal to the corresponding ifMtu for this frame
                    relay UNI/NNI logical port."
            REFERENCE   "FRF.1 [31]
                         Q.922 [25]
                         Q.933 [22]"
            DEFVAL { 1600 }
            ::= { frPVCEndptEntry 2 }

        frPVCEndptInBc OBJECT-TYPE
            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed burst size (Bc) parameter (measured in
                    bits) for this PVC end-point in the ingress
                    direction (into the frame relay network).

                    Note that the max value of this range is lower
                    than the max value allowed by Q.933 (16383 *
                    10**6).




Rehbehn & Fowler            Standards Track                    [Page 35]

RFC 2954                Frame Relay Service MIB             October 2000


                    Note that the value is encoded in bits whilst the
                    Q.933 Link layer core parameters information
                    element encodes this information using octet
                    units."
            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 3 }

        frPVCEndptInBe OBJECT-TYPE
            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the excess
                    burst size (Be) parameter (measured in bits) for
                    this PVC end-point in the ingress direction (into
                    the frame relay network).

                    Note that the max value of this range is lower
                    than the max value allowed by Q.933 (16383 *
                    10**6).

                    Note that the value is encoded in bits whilst the
                    Q.933 Link layer core parameters information
                    element encodes this information using octet
                    units."
            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 4 }

        frPVCEndptInCIR OBJECT-TYPE
            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits per Second"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed information rate (CIR) parameter
                    (measured in bits per second) for this PVC end-
                    point in the ingress direction (into the frame
                    relay network).

                    Note that the max value of this range is lower
                    than the max value allowed by Q.933 (2047 *
                    10**6)."
            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 5 }

        frPVCEndptOutMaxFrameSize OBJECT-TYPE



Rehbehn & Fowler            Standards Track                    [Page 36]

RFC 2954                Frame Relay Service MIB             October 2000


            SYNTAX      Integer32 (1..4096)
            UNITS       "Octets"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is the size in octets of
                    the largest frame relay information field for this
                    PVC end-point in the egress direction (out of the
                    frame relay network).  The value of
                    frPVCEndptOutMaxFrameSize must be less than or
                    equal to the corresponding ifMtu for this frame
                    relay UNI/NNI logical port."
            REFERENCE   "FRF.1 [31]
                         Q.922 [25]
                         Q.933 [22]"
            DEFVAL { 1600 }
            ::= { frPVCEndptEntry 6 }

        frPVCEndptOutBc OBJECT-TYPE
            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed burst size (Bc) parameter (measured in
                    bits) for this PVC end-point in the egress
                    direction (out of the frame relay network).

                    Note that the max value of this range is lower
                    than the max value allowed by Q.933 (16383 *
                    10**6).

                    Note that the value is encoded in bits whilst the
                    Q.933 Link layer core parameters information
                    element encodes this information using octet
                    units."
            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 7 }

        frPVCEndptOutBe OBJECT-TYPE
            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the excess
                    burst size (Be) parameter (measured in bits) for



Rehbehn & Fowler            Standards Track                    [Page 37]

RFC 2954                Frame Relay Service MIB             October 2000


                    this PVC end-point in the egress direction (out of
                    the frame relay network).

                    Note that the max value of this range is lower
                    than the max value allowed by Q.933 (16383 *
                    10**6).

                    Note that the value is encoded in bits whilst the
                    Q.933 Link layer core parameters information
                    element encodes this information using octet
                    units."
            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 8 }

        frPVCEndptOutCIR OBJECT-TYPE
            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits per Second"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed information rate (CIR) parameter
                    (measured in bits per second) for this PVC end-
                    point in the egress direction (out of the frame
                    relay network).

                    Note that the max value of this range is lower
                    than the max value allowed by Q.933 (2047 *
                    10**6)."
            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 9 }

        frPVCEndptConnectIdentifier OBJECT-TYPE
            SYNTAX      Integer32 (0..2147483647)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object is used to associate PVC end-points
                    as being part of one PVC segment connection. This
                    value of this object is equal to the value of
                    frPVCConnectIndex, which is used as one of the
                    indices into the frPVCConnectTable.

                    A connection that has been cross-connected via the
                    FR/ATM PVC Service IWF cross-connect table will
                    return the value zero when this object is read. In
                    case of these interworked connections, the
                    frPVCEndptAtmIwfConnIndex object must be accessed



Rehbehn & Fowler            Standards Track                    [Page 38]

RFC 2954                Frame Relay Service MIB             October 2000


                    to select the entry in the FR/ATM PVC Service IWF
                    cross-connect table.

                    The value of this object is provided by the agent,
                    after the associated entries in the
                    frPVCConnectTable or frAtmIwfConnectionTable have
                    been created."
            ::= { frPVCEndptEntry 10 }

        frPVCEndptRowStatus OBJECT-TYPE
            SYNTAX      RowStatus
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "This object is used to create new rows in this
                    table, modify existing rows, and to delete
                    existing rows.  To create a new PVC, the entries
                    for the PVC segment end-points in the
                    frPVCEndptTable must first be created.  Next, the
                    frPVCConnectTable is used to associate the frame
                    relay PVC segment end-points.  In order for the
                    manager to have the necessary error diagnostics,
                    the frPVCEndptRowStatus object must initially be
                    set to `createAndWait(5)'.  While the
                    frPVCEndptRowStatus object is in the
                    `createAndWait(5)' state, the manager can set each
                    columnar object and get the necessary error
                    diagnostics.  The frPVCEndptRowStatus object may
                    not be set to `active(1)' unless the following
                    columnar objects exist in this row:
                    frPVCEndptInMaxFrameSize, frPVCEndptInBc,
                    frPVCEndptInBe, frPVCEndptInCIR,
                    frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,
                    frPVCEndptOutBe, and frPVCEndptOutCIR."
            ::= { frPVCEndptEntry 11 }

        frPVCEndptRcvdSigStatus OBJECT-TYPE
            SYNTAX      INTEGER {
                        deleted(1),
                        active(2),
                        inactive(3),
                        none(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the PVC
                    status received via the local in-channel signaling



Rehbehn & Fowler            Standards Track                    [Page 39]

RFC 2954                Frame Relay Service MIB             October 2000


                    procedures for this PVC end-point.  This object is
                    only pertinent for interfaces that perform the
                    bidirectional procedures.

                    Each value has the following meaning:
                      deleted(1):  This PVC is not listed in the full
                                   status reports received from the
                                   user device.  The object retains
                                   this value for as long as the PVC
                                   is not listed in the full status
                                   reports

                    active(2):   This PVC is reported as active, or
                                   operational, by the user device.

                      inactive(3): This PVC is reported as inactive,
                                   or non-operational, by the user
                                   device.

                      none(4):     This interface is only using the
                                   network-side in-channel signaling
                                   procedures, so this object does
                                   not apply."
            ::= { frPVCEndptEntry 12 }

        frPVCEndptInFrames OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) for this PVC end-point. This includes
                    any frames discarded by the network due to
                    submitting more than Bc + Be data or due to any
                    network congestion recovery procedures."
            ::= { frPVCEndptEntry 13 }

        frPVCEndptOutFrames OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    regardless of whether they are Bc or Be frames for
                    this PVC end-point."
            ::= { frPVCEndptEntry 14 }



Rehbehn & Fowler            Standards Track                    [Page 40]

RFC 2954                Frame Relay Service MIB             October 2000


        frPVCEndptInDEFrames OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) with the DE bit set to (1) for this PVC
                    end-point."
            ::= { frPVCEndptEntry 15 }

        frPVCEndptInExcessFrames OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) for this PVC end-point which were
                    treated as excess traffic.  Frames which are sent
                    to the network with DE set to zero are treated as
                    excess when more than Bc bits are submitted to the
                    network during the Committed Information Rate
                    Measurement Interval (Tc).  Excess traffic may or
                    may not be discarded at the ingress if more than
                    Bc + Be bits are submitted to the network during
                    Tc.  Traffic discarded at the ingress is not
                    recorded in frPVCEndptInExcessFrames.  Frames
                    which are sent to the network with DE set to one
                    are also treated as excess traffic."
            ::= { frPVCEndptEntry 16 }

        frPVCEndptOutExcessFrames OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    for this PVC end-point which were treated as
                    excess traffic.  (The DE bit may be set to one.)"
            ::= { frPVCEndptEntry 17 }

        frPVCEndptInDiscards OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current



Rehbehn & Fowler            Standards Track                    [Page 41]

RFC 2954                Frame Relay Service MIB             October 2000


            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that were discarded due to traffic
                    enforcement for this PVC end-point.  Congestion
                    discards are not counted in this object."
            ::= { frPVCEndptEntry 18 }

        frPVCEndptInOctets OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of octets received by the network
                    (ingress) for this PVC end-point.  This counter
                    should only count octets from the beginning of the
                    frame relay header field to the end of user data.
                    If the network supporting frame relay can not
                    count octets, then this count should be an
                    approximation."
            ::= { frPVCEndptEntry 19 }

        frPVCEndptOutOctets OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of octets sent by the network (egress)
                    for this PVC end-point.  This counter should only
                    count octets from the beginning of the frame relay
                    header field to the end of user data.  If the
                    network supporting frame relay can not count
                    octets, then this count should be an
                    approximation."
            ::= { frPVCEndptEntry 20 }

        frPVCEndptInDiscardsDESet OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that were discarded with the DE bit set
                    due to traffic enforcement for this PVC end-point.
                    Congestion discards are not counted in this
                    object."



Rehbehn & Fowler            Standards Track                    [Page 42]

RFC 2954                Frame Relay Service MIB             October 2000


            ::= { frPVCEndptEntry 21 }

        frPVCEndptInFramesFECNSet OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that have the FECN bit set for this PVC
                    end-point."
            ::= { frPVCEndptEntry 22 }

        frPVCEndptOutFramesFECNSet OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    that have the FECN bit set for this PVC end-
                    point."
            ::= { frPVCEndptEntry 23 }

        frPVCEndptInFramesBECNSet OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that have the BECN bit set for this PVC
                    end-point."
            ::= { frPVCEndptEntry 24 }

        frPVCEndptOutFramesBECNSet OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    that have the BECN bit set for this PVC end-
                    point."
            ::= { frPVCEndptEntry 25 }

        frPVCEndptInCongDiscards OBJECT-TYPE
            SYNTAX      Counter32



Rehbehn & Fowler            Standards Track                    [Page 43]

RFC 2954                Frame Relay Service MIB             October 2000


            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that were discarded due to input buffer
                    congestion, rather than traffic enforcement, for
                    this PVC end-point."
            ::= { frPVCEndptEntry 26 }

        frPVCEndptInDECongDiscards OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames counted by
                    frPVCEndptInCongDiscards with the DE bit set to
                    (1)."
            ::= { frPVCEndptEntry 27 }

        frPVCEndptOutCongDiscards OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    that were discarded due to output buffer
                    congestion for this PVC end-point."
            ::= { frPVCEndptEntry 28 }

        frPVCEndptOutDECongDiscards OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames counted by
                    frPVCEndptOutCongDiscards with the DE bit set to
                    (1)."
            ::= { frPVCEndptEntry 29 }

        frPVCEndptOutDEFrames OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current



Rehbehn & Fowler            Standards Track                    [Page 44]

RFC 2954                Frame Relay Service MIB             October 2000


            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    with the DE bit set to (1) for this PVC end-
                    point."
            ::= { frPVCEndptEntry 30 }

        frPVCEndptAtmIwfConnIndex OBJECT-TYPE
            SYNTAX      Integer32  (0..2147483647)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object contains the index value of the
                    FR/ATM cross-connect table entry used to link the
                    frame relay PVC with an ATM PVC.

                    Each row of the frPVCEndptTable that is not
                    cross-connected with an ATM PVC must return the
                    value zero when this object is read.

                    The value of this object is initialized by the
                    agent after the associated entries in the
                    frAtmIwfConnectionTable have been created.

                    The value of this object is reset to zero
                    following destruction of the associated entry in
                    the frAtmIwfConnectionTable"
            ::= { frPVCEndptEntry 31 }

        --
        -- Frame Relay PVC Connections
        --

        frPVCConnectIndexValue OBJECT-TYPE
            SYNTAX      INTEGER (0..2147483647)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object returns a hint to be used for
                    frPVCConnectIndex when creating entries in the
                    frPVCConnectTable.

                    The value 0 indicates that no unassigned entries
                    are available.

                    To obtain the frPVCConnectIndex value for a new
                    entry, the manager issues a management protocol
                    retrieval operation to obtain the current value of
                    this object.  After each retrieval, the agent must



Rehbehn & Fowler            Standards Track                    [Page 45]

RFC 2954                Frame Relay Service MIB             October 2000


                    modify the value to the next unassigned index to
                    prevent assignment of the same value to multiple
                    management systems.

                    A management system should repeat the read to
                    obtain a new value should an attempt to create the
                    new row using the previously returned hint fail."
            ::= { frnetservObjects 4 }

        frPVCConnectTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF FrPVCConnectEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay PVC Connect Table is used to
                    model the bi-directional PVC segment flows
                    including:  point-to-point PVCs, point-to-
                    multipoint PVCs, and multipoint-to-multipoint
                    PVCs.

                    This table has read-create access and is used to
                    associate PVC end-points together as belonging to
                    one connection.  The frPVCConnectIndex is used to
                    associate all the bi-directional flows.  Not all
                    implementations will support the capability of
                    creating/modifying/deleting PVCs using SNMP as a
                    feature of frame relay CNM service.

                    Once the entries in the frPVCEndptTable are
                    created, the following step are used to associate
                    the PVC end-points as belonging to one PVC
                    connection:

                    1)  Obtain a unique frPVCConnectIndex
                        using the frPVCConnectIndexValue object.

                    2)  Connect the PVC segment endpoints together
                        with the applicable frPVCConnectIndex value
                        obtained via  frPVCConnectIndexValue.  The
                        entries in this table are created by using
                        the frPVCConnectRowStatus object.

                    3)  The agent will provide the value of the
                        corresponding instances of
                        frPVCEndptConnectIdentifier with the
                        frPVCConnectIndex value.

                    4)  Set frPVCConnectAdminStatus to `active(1)' in



Rehbehn & Fowler            Standards Track                    [Page 46]

RFC 2954                Frame Relay Service MIB             October 2000


                        all rows for this PVC segment to turn the
                        PVC on.

                    For example, the Frame Relay PVC Connection Group
                    models a bi-directional, point-to-point PVC
                    segment as one entry in this table.

                    Frame Relay                           Frame Relay
                     Network                                 Network
                     Low Port                               High Port
                             __________________________________
                            |                                  |
                       _____| >> from low to high PVC flow  >> |_____
                            | << from high to low PVC flow  << |
                            |__________________________________|

                    The terms low and high are chosen to represent
                    numerical ordering of a PVC segment's endpoints
                    for representation in this table.  That is, the
                    endpoint with the lower value of ifIndex is termed
                    'low', while the opposite endpoint of the segment
                    is termed 'high'.  This terminology is to provide
                    directional information; for example the
                    frPVCConnectL2hOperStatus and
                    frPVCConnectH2lOperStatus as illustrated above.

                    If the Frame Relay Connection table is used to
                    model a unidirectional PVC, then one direction
                    (either from low to high or from high to low) has
                     its Operational Status equal to down.

                     A PVC segment is a portion of a PVC that traverses
                    one Frame Relay Network, and a PVC segment is
                    identified by its two end-points (UNI/NNI logical
                    port index value and DLCI index value) through one
                    Frame Relay Network."
            ::= { frnetservObjects 5 }

        frPVCConnectEntry OBJECT-TYPE
            SYNTAX      FrPVCConnectEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay PVC Connect table.
                    This entry is used to model a PVC segment in two
                    directions."
            INDEX { frPVCConnectIndex,
                    frPVCConnectLowIfIndex,



Rehbehn & Fowler            Standards Track                    [Page 47]

RFC 2954                Frame Relay Service MIB             October 2000


                    frPVCConnectLowDLCIIndex,
                    frPVCConnectHighIfIndex,
                    frPVCConnectHighDLCIIndex }
            ::= { frPVCConnectTable 1 }

        FrPVCConnectEntry ::=
            SEQUENCE {
                frPVCConnectIndex            Integer32,
                frPVCConnectLowIfIndex       InterfaceIndex,
                frPVCConnectLowDLCIIndex     Integer32,
                frPVCConnectHighIfIndex      InterfaceIndex,
                frPVCConnectHighDLCIIndex    Integer32,
                frPVCConnectAdminStatus      INTEGER,
                frPVCConnectL2hOperStatus    INTEGER,
                frPVCConnectH2lOperStatus    INTEGER,
                frPVCConnectL2hLastChange    TimeStamp,
                frPVCConnectH2lLastChange    TimeStamp,
                frPVCConnectRowStatus        RowStatus,
                frPVCConnectUserName         SnmpAdminString,
                frPVCConnectProviderName     SnmpAdminString
        }

          frPVCConnectIndex OBJECT-TYPE
              SYNTAX      Integer32 (0..2147483647)
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "The value of this object is equal to the
                      frPVCConnectIndexValue obtained to uniquely
                      identify this PVC segment connection."
              ::= { frPVCConnectEntry 1 }

        frPVCConnectLowIfIndex OBJECT-TYPE
            SYNTAX      InterfaceIndex
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to IF-MIB
                    ifIndex value of the UNI/NNI logical port for this
                    PVC segment.  The term low implies that this PVC
                    segment end-point has the numerically lower
                    ifIndex value than the connected/associated PVC
                    segment end-point.

                    RFC 1604 permitted a zero value for this object to
                    identify termination at a non-frame relay
                    interface.  However, this cross-connect table is
                    limited to frame relay connections.  See the frame



Rehbehn & Fowler            Standards Track                    [Page 48]

RFC 2954                Frame Relay Service MIB             October 2000


                    relay/ATM IWF MIB [28] for the cross-connect table
                    used for those types of connections."
            ::= { frPVCConnectEntry 2 }

        frPVCConnectLowDLCIIndex OBJECT-TYPE
            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the DLCI
                    value for this end-point of the PVC segment."
            REFERENCE   "Q.922 [25]"
            ::= { frPVCConnectEntry 3 }

        frPVCConnectHighIfIndex OBJECT-TYPE
            SYNTAX      InterfaceIndex
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to IF-MIB
                    ifIndex value for the UNI/NNI logical port for
                    this PVC segment.  The term high implies that this
                    PVC segment end-point has the numerically higher
                    ifIndex value than the connected/associated PVC
                    segment end-point."
            ::= { frPVCConnectEntry 4 }

        frPVCConnectHighDLCIIndex OBJECT-TYPE
            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the egress
                    DLCI value for this end-point of the PVC segment."
            REFERENCE   "Q.922 [25]"
            ::= { frPVCConnectEntry 5 }

        frPVCConnectAdminStatus OBJECT-TYPE
            SYNTAX      INTEGER {
                        active(1),
                        inactive(2),
                        testing(3)
                        }
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    administrative status of this bi-directional PVC



Rehbehn & Fowler            Standards Track                    [Page 49]

RFC 2954                Frame Relay Service MIB             October 2000


                    segment.  The active(1) state means the PVC
                    segment is currently operational; the inactive(2)
                    state means the PVC segment is currently not
                    operational; the testing(3) state means the PVC
                    segment is currently undergoing a test.  This
                    state is set by an administrative entity.  This
                    value affects the PVC status indicated across the
                    ingress NNI/UNI of both end-points of the bi-
                    directional PVC segment.  When a PVC segment
                    connection is created using this table, this
                    object is initially set to `inactive(2)'.  After
                    the frPVCConnectRowStatus object is set to
                    `active(1)' (and the corresponding/associated
                    entries in the frPVCEndptTable have their
                    frPVCEndptRowStatus object set to `active(1)'),
                    the frPVCConnectAdminStatus object may be set to
                    `active(1)' to turn on the PVC segment
                    connection."
            ::= { frPVCConnectEntry 6 }

        frPVCConnectL2hOperStatus OBJECT-TYPE
            SYNTAX      INTEGER {
                        active(1),
                        inactive(2),
                        testing(3),
                        unknown(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the current
                    operational status of the PVC segment connection
                    in one direction; (i.e., in the low to high
                    direction). This value affects the PVC status
                    indicated across the ingress NNI/UNI (low side) of
                    the PVC segment.

                    The values mean:

                    active(1)   - PVC is currently operational

                    inactive(2) - PVC is currently not operational.
                                  This may be because of an underlying
                                  LMI or DS1 failure.

                    testing(3)  - PVC is currently undergoing a test.
                                  This may be because of an underlying
                                  frLport or DS1 undergoing a test.



Rehbehn & Fowler            Standards Track                    [Page 50]

RFC 2954                Frame Relay Service MIB             October 2000


                    unknown(4)  - the status of the PVC currently can
                                  not be determined."
            ::= { frPVCConnectEntry 7 }

        frPVCConnectH2lOperStatus OBJECT-TYPE
            SYNTAX      INTEGER {
                        active(1),
                        inactive(2),
                        testing(3),
                        unknown(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the current
                    operational status of the PVC segment connection
                    in one direction; (i.e., in the high to low
                    direction)..  This value affects the PVC status
                    indicated across the ingress NNI/UNI (high side)
                    of the PVC segment.

                    The values mean:

                    active(1)   - PVC is currently operational

                    inactive(2) - PVC is currently not operational.
                                  This may be because of an underlying
                                  LMI or DS1 failure.

                    testing(3)  - PVC is currently undergoing a test.
                                  This may be because of an underlying
                                  frLport or DS1 undergoing a test.

                    unknown(4)  - the status of the PVC currently can
                                  not be determined."
            ::= { frPVCConnectEntry 8 }

        frPVCConnectL2hLastChange OBJECT-TYPE
            SYNTAX      TimeStamp
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of the Interface MIB's sysUpTime object
                    at the time this PVC segment entered its current
                    operational state in the low to high direction.
                    If the current state was entered prior to the last
                    re-initialization of the FRS agent, then this
                    object contains a zero value."



Rehbehn & Fowler            Standards Track                    [Page 51]

RFC 2954                Frame Relay Service MIB             October 2000


            ::= { frPVCConnectEntry 9 }

        frPVCConnectH2lLastChange OBJECT-TYPE
            SYNTAX      TimeStamp
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of the Interface MIB's sysUpTime object
                    at the time this PVC segment entered its current
                    operational state in the high to low direction.
                    If the current state was entered prior to the last
                    re-initialization of the FRS agent, then this
                    object contains a zero value."
            ::= { frPVCConnectEntry 10 }

        frPVCConnectRowStatus OBJECT-TYPE
            SYNTAX      RowStatus
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The status of this entry in the
                    frPVCConnectTable.  This variable is used to
                    create new connections for the PVC end-points and
                    to change existing connections of the PVC end-
                    points.  This object must be initially set to
                    `createAndWait(5)'. In this state, the agent
                    checks the parameters in the associated entries in
                    the frPVCEndptTable to verify that the PVC end-
                    points can be connected (i.e., the In parameters
                    for one PVC end-point are equal to the Out
                    parameters for the other PVC end-point).  This
                    object can not be set to `active(1)' unless the
                    following columnar object exists in this row:
                    frPVCConnectAdminStatus.  The agent also supplies
                    the associated value of frPVCConnectIndex for the
                    frPVCEndptConnectIdentifier instances.  To turn on
                    a PVC segment connection, the
                    frPVCConnectAdminStatus is set to `active(1)'."
            ::= { frPVCConnectEntry 11 }

        frPVCConnectUserName OBJECT-TYPE
            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "This is a service user assigned textual
                    representation of a PVC."
            ::= { frPVCConnectEntry 12 }



Rehbehn & Fowler            Standards Track                    [Page 52]

RFC 2954                Frame Relay Service MIB             October 2000


        frPVCConnectProviderName OBJECT-TYPE
            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "This is a system supplied textual representation
                    of PVC.  It is assigned by the service provider."
            ::= { frPVCConnectEntry 13 }

        --
        -- The Frame Relay Accounting
        --

        frAccountPVCTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF FrAccountPVCEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay Accounting PVC table.  This table
                    is used to perform accounting on a PVC segment
                    end-point basis."
            ::= { frnetservObjects 6 }

        frAccountPVCEntry OBJECT-TYPE
            SYNTAX      FrAccountPVCEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Accounting PVC
                    table."
            INDEX   {   ifIndex,
                        frAccountPVCDLCIIndex }
            ::= { frAccountPVCTable 1 }

        FrAccountPVCEntry ::=
            SEQUENCE {
                frAccountPVCDLCIIndex            Integer32,
                frAccountPVCSegmentSize          Integer32,
                frAccountPVCInSegments           Counter32,
                frAccountPVCOutSegments          Counter32
            }

        frAccountPVCDLCIIndex OBJECT-TYPE
            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the DLCI



Rehbehn & Fowler            Standards Track                    [Page 53]

RFC 2954                Frame Relay Service MIB             October 2000


                    value for this PVC segment end-point."
            REFERENCE   "Q.922 [25]"
            ::= { frAccountPVCEntry 1 }

        frAccountPVCSegmentSize OBJECT-TYPE
            SYNTAX      Integer32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the Segment
                    Size for this PVC segment end-point."
            ::= { frAccountPVCEntry 2 }

        frAccountPVCInSegments OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number
                    of segments received by this PVC segment end-
                    point."
            ::= { frAccountPVCEntry 3 }

        frAccountPVCOutSegments OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number
                    of segments sent by this PVC segment end-point."
            ::= { frAccountPVCEntry 4 }

        --
        -- Accounting on a Frame Relay Logical Port
        --

        frAccountLportTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF FrAccountLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay Accounting Logical Port table.
                    This table is used to perform accounting on a
                    UNI/NNI Logical Port basis."
            ::= { frnetservObjects 7 }



Rehbehn & Fowler            Standards Track                    [Page 54]

RFC 2954                Frame Relay Service MIB             October 2000


        frAccountLportEntry OBJECT-TYPE
            SYNTAX      FrAccountLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Accounting Logical
                    Port table."
            INDEX   {   ifIndex }
            ::= { frAccountLportTable 1 }

        FrAccountLportEntry ::=
            SEQUENCE {
                frAccountLportSegmentSize
                    Integer32,
                frAccountLportInSegments
                    Counter32,
                frAccountLportOutSegments
                    Counter32
            }

        frAccountLportSegmentSize OBJECT-TYPE
            SYNTAX      Integer32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the Segment
                    Size for this UNI/NNI logical port."
            ::= { frAccountLportEntry 1 }

        frAccountLportInSegments OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number
                    of segments received by this UNI/NNI logical
                    port."
            ::= { frAccountLportEntry 2 }

        frAccountLportOutSegments OBJECT-TYPE
            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number



Rehbehn & Fowler            Standards Track                    [Page 55]

RFC 2954                Frame Relay Service MIB             October 2000


                    of segments sent by this UNI/NNI logical port."
            ::= { frAccountLportEntry 3 }

          --
          -- Frame Relay Network Service Notifications
          --

        frPVCConnectStatusChange  NOTIFICATION-TYPE
            OBJECTS { frPVCConnectIndex,
                      frPVCConnectLowIfIndex,
                      frPVCConnectLowDLCIIndex,
                      frPVCConnectHighIfIndex,
                      frPVCConnectHighDLCIIndex,
                      frPVCConnectL2hOperStatus,
                      frPVCConnectH2lOperStatus,
                      frPVCEndptRcvdSigStatus }
            STATUS  deprecated
            DESCRIPTION
                    "Refer to the description of the
                    frPVCConnectStatusNotif notification that has
                    replaced this notification.  The notification is
                    deprecated due to the incorrect inclusion of index
                    values and to take advantage of the trap prefix
                    for automatic conversion from SMIv2 to SMIv1 by
                    making the one but last sub-ID a zero (i.e. the
                    so-called trap prefix)."
            ::= { frnetservTraps 1 }

        frPVCConnectStatusNotif  NOTIFICATION-TYPE
            OBJECTS { frPVCConnectL2hOperStatus,
                      frPVCConnectH2lOperStatus,
                      frPVCEndptRcvdSigStatus }
            STATUS  current
            DESCRIPTION
                    "This notification indicates that the indicated
                    PVC has changed state.

                    This notification is not sent if an FR-UNI changes
                    state; a linkDown or linkUp notification should be
                    sent instead.  The first instance of
                    frPVCEndptRcvdSigStatus is for the endpoint with
                    LowIfIndex, LowDLCIIndex.  The second instance of
                    frPVCEndptRcvdSigStatus is for the endpoint with
                    HighIfIndex, HighDLCIIndex"
            ::= { frnetservTrapsPrefix 2 }

        -- Conformance Information




Rehbehn & Fowler            Standards Track                    [Page 56]

RFC 2954                Frame Relay Service MIB             October 2000


        frnetservConformance  OBJECT IDENTIFIER
            ::= { frnetservMIB 3 }

        frnetservGroups       OBJECT IDENTIFIER
            ::= { frnetservConformance 1 }
        frnetservCompliances  OBJECT IDENTIFIER
            ::= { frnetservConformance 2 }


        --
        --  Service (Read-only) Modules
        --
        frnetservCompliance2 MODULE-COMPLIANCE
            STATUS      current
            DESCRIPTION
                    "The compliance statement for SNMP entities which
                    have Frame Relay Network Service Interfaces.

                    The distinction between 'service' and 'switch' is
                    that a 'switch' is configured via this MIB.
                    Hence, the various read/write objects have write
                    capability.  A 'service' represents a passive
                    monitor-only customer network management
                    interface.  The various read/write objects are
                    restricted to read-only capability."
            MODULE -- this module
                MANDATORY-GROUPS { frnetservLportGroup2,
                                   frnetservMgtVCSigGroup,
                                   frnetservPVCEndptGroup,
                                   frnetservPVCEndptGroup2,
                                   frnetservPVCConnectGroup,
                                   frnetservPVCConnectNamesGroup,
                                   frnetservPVCNotifGroup2 }

                GROUP       frnetservAccountPVCGroup
                DESCRIPTION
                    "This group is optional for frame relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a PVC basis this frame
                    relay interface."
                GROUP       frnetservAccountLportGroup
                DESCRIPTION
                    "This group is optional for frame relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a logical port basis
                    this frame relay interface."

                OBJECT      frPVCEndptInMaxFrameSize



Rehbehn & Fowler            Standards Track                    [Page 57]

RFC 2954                Frame Relay Service MIB             October 2000


                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptInBc
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptInBe
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptInCIR
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutMaxFrameSize
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutBc
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutBe
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutCIR
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptRowStatus
             -- subset of RowStatus
                SYNTAX      INTEGER { active(1) }
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required, and only one of the
                    six enumerated values for the RowStatus textual
                    convention need be supported, specifically:
                    active(1)."



Rehbehn & Fowler            Standards Track                    [Page 58]

RFC 2954                Frame Relay Service MIB             October 2000


                OBJECT      frPVCConnectAdminStatus
                MIN-ACCESS  read-only
                DESCRIPTION
                     "Write access is not required."

                OBJECT      frPVCConnectRowStatus
             -- subset of RowStatus
                SYNTAX      INTEGER { active(1) }
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required, and only one of the
                    six enumerated values for the RowStatus textual
                    convention need be supported, specifically:
                    active(1)."

                OBJECT      frLportFragControl
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frLportFragSize
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCConnectUserName
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCConnectProviderName
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

              ::= { frnetservCompliances 2 }

        --
        -- Switch (Configuration) Compliance
        --
        frnetSwitchCompliance MODULE-COMPLIANCE
            STATUS      current
            DESCRIPTION
                    "The compliance statement for SNMP entities which
                    have Frame Relay Network Switch objects.

                    The distinction between 'service' and 'switch' is
                    that a 'switch' is configured via this MIB.



Rehbehn & Fowler            Standards Track                    [Page 59]

RFC 2954                Frame Relay Service MIB             October 2000


                    Hence, the various read/write objects have write
                    capability.  A 'service' represents a passive
                    monitor-only customer network management
                    interface.  The various read/write objects are
                    restricted to read-only capability."
            MODULE -- this module
                MANDATORY-GROUPS { frnetservLportGroup2,
                                   frnetservLportAdminGroup,
                                   frnetservMgtVCSigGroup,
                                   frnetservMgtVCSigAdminGroup,
                                   frnetservPVCEndptGroup,
                                   frnetservPVCEndptGroup2,
                                   frnetservPVCConnectGroup,
                                   frnetservPVCConnectNamesGroup,
                                   frnetservPVCNotifGroup2 }

                GROUP       frnetservAccountPVCGroup
                DESCRIPTION
                    "This group is optional for frame relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a PVC basis this frame
                    relay interface."
                GROUP       frnetservAccountLportGroup
                DESCRIPTION
                    "This group is optional for frame relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a logical port basis
                    this frame relay interface."

              ::= { frnetservCompliances 3 }

         --
         -- Historical RFC 1604 Compliance Modules
         --

        frnetservCompliance MODULE-COMPLIANCE
            STATUS  deprecated
            DESCRIPTION
                    "The compliance statement for SNMP entities which
                    have Frame Relay Network Service Interfaces.

                    This compliance statement has been deprecated in
                    favor of frnetservCompliance2.  The new compliance
                    module expands the mandatory groups to include
                    notification and other new objects."

            MODULE -- this module
                MANDATORY-GROUPS { frnetservLportGroup,



Rehbehn & Fowler            Standards Track                    [Page 60]

RFC 2954                Frame Relay Service MIB             October 2000


                                   frnetservMgtVCSigGroup,
                                   frnetservPVCEndptGroup,
                                   frnetservPVCConnectGroup }

                GROUP       frnetservAccountPVCGroup
                DESCRIPTION
                    "This group is optional for Frame Relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a PVC basis this Frame
                    Relay interface."

                GROUP       frnetservAccountLportGroup
                DESCRIPTION
                    "This group is optional for Frame Relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a logical port basis
                    this Frame Relay interface."

                OBJECT      frPVCEndptInMaxFrameSize
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCEndptInBc
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."
                OBJECT      frPVCEndptInBe
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCEndptInCIR
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCEndptOutMaxFrameSize
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCEndptOutBc
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCEndptOutBe



Rehbehn & Fowler            Standards Track                    [Page 61]

RFC 2954                Frame Relay Service MIB             October 2000


                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCEndptOutCIR
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCEndptRowStatus
             -- subset of RowStatus
                SYNTAX      INTEGER { active(1) }
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required, and only one of the
                    six enumerated values for the RowStatus textual
                    convention need be supported, specifically:
                    active(1)."

                OBJECT      frPVCConnectAdminStatus
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required."

                OBJECT      frPVCConnectRowStatus
             -- subset of RowStatus
                SYNTAX      INTEGER { active(1) }
                MIN-ACCESS  read-only
                DESCRIPTION
                    "Write access is not required, and only one of the
                    six enumerated values for the RowStatus textual
                    convention need be supported, specifically:
                    active(1)."
            ::= { frnetservCompliances 1 }

         --
         -- Frame Relay Service MIB Object Groups
         --
         frnetservLportGroup  OBJECT-GROUP
             OBJECTS { frLportNumPlan, frLportContact, frLportLocation,
                       frLportType,
                       frLportAddrDLCILen, frLportVCSigProtocol,
                       frLportVCSigPointer }
             STATUS  deprecated
             DESCRIPTION
                     "A collection of objects providing information
                     applicable to a Frame Relay Logical Port.  This
                     group has been deprecated to eliminate reference



Rehbehn & Fowler            Standards Track                    [Page 62]

RFC 2954                Frame Relay Service MIB             October 2000


                     to the object frLportVCSigPointer.

                     Use the new group frnetservLportGroup2 as a
                     replacement for this group."
             ::= { frnetservGroups 1 }

        frnetservMgtVCSigGroup  OBJECT-GROUP
            OBJECTS { frMgtVCSigProced,
                      frMgtVCSigUserN391,
                      frMgtVCSigUserN392,
                      frMgtVCSigUserN393,
                      frMgtVCSigUserT391,
                      frMgtVCSigNetN392,
                      frMgtVCSigNetN393,
                      frMgtVCSigNetT392,
                      frMgtVCSigNetnN4,
                      frMgtVCSigNetnT3,
                      frMgtVCSigUserLinkRelErrors,
                      frMgtVCSigUserProtErrors,
                      frMgtVCSigUserChanInactive,
                      frMgtVCSigNetLinkRelErrors,
                      frMgtVCSigNetProtErrors,
                      frMgtVCSigNetChanInactive }
            STATUS  current
            DESCRIPTION
                    "A collection of objects providing information
                    applicable to the Local In-Channel Signaling
                    Procedures used for a UNI/NNI logical port."
            ::= { frnetservGroups 2 }

        frnetservPVCEndptGroup  OBJECT-GROUP
            OBJECTS { frPVCConnectIndexValue,
                      frPVCEndptInMaxFrameSize,
                      frPVCEndptInBc,
                      frPVCEndptInBe,
                      frPVCEndptInCIR,
                      frPVCEndptOutMaxFrameSize,
                      frPVCEndptOutBc,
                      frPVCEndptOutBe,
                      frPVCEndptOutCIR,
                      frPVCEndptConnectIdentifier,
                      frPVCEndptRowStatus,
                      frPVCEndptRcvdSigStatus,
                      frPVCEndptInFrames,
                      frPVCEndptOutFrames,
                      frPVCEndptInDEFrames,
                      frPVCEndptInExcessFrames,
                      frPVCEndptOutExcessFrames,



Rehbehn & Fowler            Standards Track                    [Page 63]

RFC 2954                Frame Relay Service MIB             October 2000


                      frPVCEndptInDiscards,
                      frPVCEndptInOctets,
                      frPVCEndptOutOctets }
            STATUS  current
            DESCRIPTION
                    "A collection of objects providing information
                    applicable to a Frame Relay PVC end-point."
            ::= { frnetservGroups 3 }

        frnetservPVCConnectGroup  OBJECT-GROUP
            OBJECTS { frPVCConnectAdminStatus,
                      frPVCConnectL2hOperStatus,
                      frPVCConnectH2lOperStatus,
                      frPVCConnectL2hLastChange,
                      frPVCConnectH2lLastChange,
                      frPVCConnectRowStatus }
            STATUS  current
            DESCRIPTION
                    "A collection of objects providing information
                    applicable to a Frame Relay PVC connection."
            ::= { frnetservGroups 4 }

        frnetservAccountPVCGroup  OBJECT-GROUP
            OBJECTS { frAccountPVCSegmentSize,
                      frAccountPVCInSegments,
                      frAccountPVCOutSegments }
            STATUS  current
            DESCRIPTION
                    "A collection of objects providing accounting
                    information application to a Frame Relay PVC end-
                    point."
            ::= { frnetservGroups 5 }

        frnetservAccountLportGroup  OBJECT-GROUP
            OBJECTS { frAccountLportSegmentSize,
                      frAccountLportInSegments,
                      frAccountLportOutSegments }
            STATUS  current
            DESCRIPTION
                    "A collection of objects providing accounting
                    information application to a Frame Relay logical
                    port."
            ::= { frnetservGroups 6 }

        frnetservLportGroup2  OBJECT-GROUP
            OBJECTS { frLportNumPlan,
                      frLportContact,
                      frLportLocation,



Rehbehn & Fowler            Standards Track                    [Page 64]

RFC 2954                Frame Relay Service MIB             October 2000


                      frLportType,
                      frLportAddrDLCILen,
                      frLportVCSigProtocol,
                      frLportFragControl,
                      frLportFragSize }
            STATUS  current
            DESCRIPTION
                    "A collection of objects providing information
                    applicable to a Frame Relay Logical Port.

                    This new version of the Logical Port Group
                    eliminates the frLportVCSigPointer and adds
                    support for fragmentation."
            ::= { frnetservGroups 7 }

        frnetservPVCEndptGroup2  OBJECT-GROUP
              OBJECTS { frPVCEndptInDiscardsDESet,
                        frPVCEndptInFramesFECNSet,
                        frPVCEndptOutFramesFECNSet,
                        frPVCEndptInFramesBECNSet,
                        frPVCEndptOutFramesBECNSet,
                        frPVCEndptInCongDiscards,
                        frPVCEndptInDECongDiscards,
                        frPVCEndptOutCongDiscards,
                        frPVCEndptOutDECongDiscards,
                        frPVCEndptOutDEFrames,
                        frPVCEndptAtmIwfConnIndex }
              STATUS  current
              DESCRIPTION
                    "Additions to the PVC end-point group.  These
                    additions provide new frame counters to track
                    frame loss.  In addition, the new FR/ATM IWF MIB
                    cross-connect index is included."
              ::= { frnetservGroups 8 }

        frnetservPVCConnectNamesGroup  OBJECT-GROUP
              OBJECTS { frPVCConnectUserName,
                        frPVCConnectProviderName }
              STATUS  current
              DESCRIPTION
                    "Additions to the PVC Connect Group."
              ::= { frnetservGroups 9 }

        frnetservLportAdminGroup OBJECT-GROUP
              OBJECTS { frLportDLCIIndexValue,
                        frLportTypeAdmin,
                        frLportVCSigProtocolAdmin }
              STATUS  current



Rehbehn & Fowler            Standards Track                    [Page 65]

RFC 2954                Frame Relay Service MIB             October 2000


              DESCRIPTION
                    "Administrative (R/W) objects for creating a
                    switch logical port."
              ::= { frnetservGroups 10 }

        frnetservMgtVCSigAdminGroup OBJECT-GROUP
              OBJECTS { frMgtVCSigProcedAdmin,
                        frMgtVCSigUserN391Admin,
                        frMgtVCSigUserN392Admin,
                        frMgtVCSigUserN393Admin,
                        frMgtVCSigUserT391Admin,
                        frMgtVCSigNetN392Admin,
                        frMgtVCSigNetN393Admin,
                        frMgtVCSigNetT392Admin,
                        frMgtVCSigNetnT3Admin }
              STATUS  current
              DESCRIPTION

                    "A collection of objects providing information
                    applicable to the Local In-Channel Signaling
                    Procedures used for a UNI/NNI logical port."
              ::= { frnetservGroups 11 }

        frnetservPVCNotifGroup NOTIFICATION-GROUP
              NOTIFICATIONS { frPVCConnectStatusChange }
              STATUS    deprecated
              DESCRIPTION
                    "Deprecated notification group.  The
                    frPVCConnectStatusChange notification was flawed
                    because it included redundant indexes and was not
                    properly encoded for SMIv1 conversion."
            ::= { frnetservGroups 12 }

        frnetservPVCNotifGroup2 NOTIFICATION-GROUP
              NOTIFICATIONS { frPVCConnectStatusNotif }
              STATUS    current
              DESCRIPTION
                    "A collection of notifications that apply to frame
                    relay PVC Connections "
            ::= { frnetservGroups 13 }

        END









Rehbehn & Fowler            Standards Track                    [Page 66]

RFC 2954                Frame Relay Service MIB             October 2000


4.  Acknowledgments

   This document was produced by the Frame Relay Service MIB Working
   Group.

   The working group thanks Bert Wijnen, David Perkins, and Bob Stewart
   for their assistance in reviewing the MIB.

5.  References

   [1]  Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for
        Describing SNMP Management Frameworks", RFC 2571, April 1999.

   [2]  Rose, M. and K. McCloghrie, "Structure and Identification of
        Management Information for TCP/IP-based Internets", STD 16, RFC
        1155, May 1990.

   [3]  Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
        RFC 1212, March 1991.

   [4]  Rose, M., "A Convention for Defining Traps for use with the
        SNMP", RFC 1215, March 1991.

   [5]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M.  and S. Waldbusser, "Structure of Management Information
        Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.

   [6]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M.  and S. Waldbusser, "Textual Conventions for SMIv2", STD 58,
        RFC 2579, April 1999.

   [7]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M.  and S. Waldbusser, "Conformance Statements for SMIv2", STD
        58, RFC 2580, April 1999.

   [8]  Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
        Network Management Protocol", STD 15, RFC 1157, May 1990.

   [9]  Case, J., McCloghrie, K., Rose M., and S. Waldbusser,
        "Introduction to Community-based SNMPv2", RFC 1901, January
        1996.

   [10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport
        Mappings for Version 2 of the Simple Network Management Protocol
        (SNMPv2)", RFC 1906, January 1996.






Rehbehn & Fowler            Standards Track                    [Page 67]

RFC 2954                Frame Relay Service MIB             October 2000


   [11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
        Processing and Dispatching for the Simple Network Management
        Protocol (SNMP)", RFC 2572, April 1999.

   [12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
        for version 3 of the Simple Network Management Protocol
        (SNMPv3)", RFC 2574, April 1999.

   [13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
        Operations for Version 2 of the Simple Network Management
        Protocol (SNMPv2)", RFC 1905, January 1996.

   [14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC
        2573, April 1999.

   [15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
        Control Model (VACM) for the Simple Network Management Protocol
        (SNMP)", RFC 2575, April 1999.

   [16] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
        to Version 3 of the Internet-standard Network Management
        Framework", RFC 2570, April 1999.

   [17] ANSI T1.617-1991, American National Standard for
        Telecommunications - Integrated Services Digital Network (ISDN)
        - Digital Subscriber Signaling System No. 1 (DSS1) - Signaling
        Specification for Frame Relay Bearer Service.

   [18] Brown, C. and F. Baker, "Management Information Base for Frame
        Relay DTEs", RFC 2115, September 1997.

   [19] Brown, C. and A. Malis, "Multi-Protocol Interconnect over Frame
        Relay", STD 55, RFC 2427, September 1998.

   [20] Fowler, D, "Definitions of Managed Objects for the DS0 and DS0
        Bundle Interface Types", RFC 2494, January 1999.

   [21] Frame Relay Forum, "Frame Relay Fragmentation Implementation
        Agreement", FRF.12, December 1997.

   [22] ITU-T Recommendation Q.933,Integrated Services Digital Network
        (ISDN) Digital Subscriber Signalling System No. 1 (DSS 1) -
        Signalling Specifications for Frame Mode Switched and Permanent
        Virtual Connection Control and Status Monitoring, December 1995







Rehbehn & Fowler            Standards Track                    [Page 68]

RFC 2954                Frame Relay Service MIB             October 2000


   [23] ITU-T Recommendation X.36, Interface Between Data Terminal
        Equipment (DTE) and Data Circuit-Terminating Equipment (DCE) For
        Public Data Networks Providing Frame Relay Data Transmission
        Service By Dedicated Circuit, April 1995

   [24] Digital Equipment Corporation, et. al., "Frame Relay
        Specification with Extensions Based on Proposed T1S1 Standards",
        Revision 1.0, September 18, 1990

   [25] ITU-T Recommendation Q.922, Integrated Services Digital Network
        (ISDN) Data Link Layer Specification For Frame Mode Bearer
        Services, February 1992

   [26] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",
        RFC 2863, June 2000.

   [27] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
        "Management Information Base for Version 2 of the Simple Network
        Management Protocol (SNMPv2)", RFC 1907, January 1996.

   [28] Rehbehn, K., Nicklass, O. and G. Mouradian, "Definitions of
        Managed Objects for Monitoring and Controlling the Frame
        Relay/ATM PVC Service Interworking Function", RFC 2955, October
        2000.

   [29] ITU-T Recommendation E.164/I.331, The International Public
        Telecommunication Numbering Plan, May 1997

   [30] ITU-T Recommendation X.121, International Numbering Plan For
        Public Data Networks, October 1996

   [31] Frame Relay Forum, "The Frame Relay Forum User-to-Network
        Implementation Agreement (UNI)", FRF 1.2, July 2000.

6.  Security Considerations

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write and/or read-create.  Such
   objects may be considered sensitive or vulnerable in some network
   environments.  The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.

   No managed objects in this MIB contain sensitive information.







Rehbehn & Fowler            Standards Track                    [Page 69]

RFC 2954                Frame Relay Service MIB             October 2000


   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), even then, there is no
   control as to who on the secure network is allowed to access and
   GET/SET (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementers consider the security
   features as provided by the SNMPv3 framework.  Specifically, the use
   of the User-based Security Model RFC 2574 [12] and the View-based
   Access Control Model RFC 2575 [15] is recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to the objects only to those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.

7.  Authors' Addresses

   Kenneth Rehbehn
   Megisto Systems, Inc.
   20251 Century Boulevard
   Germantown, MD, USA 20874

   Phone: (301) 515-3672
   EMail: krehbehn@megisto.com


   David Fowler
   Syndesis Limited
   28 Fulton Way
   Richmond Hill, Ontario, Canada L4B 1J5

   Phone: (905) 886-7818
   EMail: fowler@syndesis.com

















Rehbehn & Fowler            Standards Track                    [Page 70]

RFC 2954                Frame Relay Service MIB             October 2000


APPENDIX A  Update Information

   The changes from RFC 1604 are the following:

   (1)  Added the object frLportDLCIIndexValue to automatically generate
        index values for new DLC rows.

   (2)  Add the following objects to support manager writing to objects:

        Logical Port Objects
            frLportTypeAdmin
            frLportVCSigProtocolAdmin

        VC Objects
            frMgtVCSigProcedAdmin
            frMgtVCSigUserN391Admin
            frMgtVCSigUserN392Admin
            frMgtVCSigUserN393Admin
            frMgtVCSigUserT391Admin
            frMgtVCSigNetN392Admin
            frMgtVCSigNetN393Admin
            frMgtVCSigNetT392Admin
            frMgtVCSigNetnT3Admin

   (3)  Add objects to control fragmentation:

        frLportFragControl frLportFragSize

   (4)  Added objects to track frames offered to network (in) and
        delivered (out) for increased visibility into policing-driven
        discards, congestion-driven discards, DE-bit setting, and
        congestion bit setting:

        frPVCEndptInDiscardsDESet
        frPVCEndptInFramesFECNSet
        frPVCEndptOutFramesFECNSet
        frPVCEndptInFramesBECNSet
        frPVCEndptOutFramesBECNSet
        frPVCEndptInCongDiscards
        frPVCEndptInDECongDiscards
        frPVCEndptOutCongDiscards
        frPVCEndptOutDECongDiscards
        frPVCEndptOutDEFrames

   (5)  Added the PVC object frPVCEndptAtmIwfConnIndex to identify the
        type of connection, frame relay or ATM IWF; and to identify the
        cross-connect row of the FR/ATM IWF MIB.




Rehbehn & Fowler            Standards Track                    [Page 71]

RFC 2954                Frame Relay Service MIB             October 2000


   (6)  Added objects to provide printable names of the connection user
        and service provider:

        frPVCConnectUserName
        frPVCConnectProviderName

   (7)  Added a new notification to correct flaws in the RFC1604 trap.
        The flaws include improper OID suffix (SMIv1 compatibility
        issue) and the inclusion of redundant index fields

   (8)  Updated compliance modules and object groups to reflect the new
        objects and notification:

        frnetservCompliance2 -      New service-centric (read-only)
                                    compliance module

        frnetSwitchCompliance -     New switch-centric (read-write)
                                    compliance module

        frnetservCompliance -       Original RFC 1604 Module, now
                                    deprecated

        frnetservLportGroup -       Original RFC 1604 logical port
                                    group, now deprecated

        frnetservLportGroup2 -      Replacement logical port group

        frnetservPVCEndptGroup2 -   Extension objects with this
                                    revision of the MIB

        frnetservPVCConnectNamesGroup - New group w/ display names
                                    for connections

        frnetservLportAdminGroup -  New group w/ read-write objects
                                    for the logical port

        frnetservMgtVCSigAdminGroup - New group w/ read-write objects
                                    for the signaling protocol

        frnetservPVCNotifGroup -    Group deprecated to eliminate
                                    obsolete frPVCConnectStatusChange
                                    notification

        frnetservPVCNotifGroup2 -   New group added with w/
                                    frPVCConnectStatusNotif

   (9)  Added UNITS and REFERENCE clauses for objects that needed the
        clarification.



Rehbehn & Fowler            Standards Track                    [Page 72]

RFC 2954                Frame Relay Service MIB             October 2000


   (10) Changed references to "proxy-agent" to "FRS agent" to avoid
        confusion with other proxy-agent terminology.

   (11) Changed objects using the DisplayString TC to use the
        SnmpAdminString TC.

   (12) frMgtVCSigProced - Expanded to include the u2nuser(3)
        enumeration for the UNI protocol operation where the logical
        port operates in the user role.

   (13) DESCRIPTION text added to specify agent response when object is
        not instantiated  for the following objects:

        frMgtVCSigUserN391
        frMgtVCSigUserN393
        frMgtVCSigUserT391
        frMgtVCSigUserN392
        frMgtVCSigNetN391
        frMgtVCSigNetN393
        frMgtVCSigNetT391
        frMgtVCSigNetN392
        frMgtVCSigNetnN4
        frMgtVCSigNetnT3
        frMgtVCSigUserLinkRelErrors
        frMgtVCSigUserProtErrors
        frMgtVCSigUserChanInactive

   (14) DESCRIPTION text addressing case of logical port not performing
        network-side procedures was removed from following objects:

        frMgtVCSigNetLinkRelErrors
        frMgtVCSigNetChanInactive
        frMgtVCSigNetProtErrors

   (15) frPVCEndptConnectIdentifier - Operation described for the case
        of FR/ATM IWF cross-connect operation.

   (16) frPVCEndptRcvdSigStatus - Added description of enumerated
        values.

   (17) frPVCEndptInDiscards - Clarified DESCRIPTION to state that
        congestion discards are not counted by object.

   (18) frPVCConnect{Low|High}IfIndex - Changed to use InterfaceIndex TC
        and changed reference to MIB-II to the new IF-MIB.  Removed
        statement asserting that a zero value means the port is not a FR
        logical port.




Rehbehn & Fowler            Standards Track                    [Page 73]

RFC 2954                Frame Relay Service MIB             October 2000


   (19) frPVCConnectIndex - Added a range to the SYNTAX clause

   (20) frPVCConnect{L2h|H2l}OperStatus - Added DESCRIPTION text for
        each enumerated value.

   (21) frAccountPVCDLCIIndex - Added a range to the SYNTAX clause

   (22) frPVCCOnnectStatusChange Notification - STATUS change to
        deprecated.  Obsoleted to eliminate inappropriate inclusion of
        index objects

   (23) frPVCConnectStatusNotif Notification - Replaces
        frPVCConnectStatusChange.  In addition, the notification now
        requires 2 instances of the frPVCEndptRcvdSigStatus object, one
        for each endpoint of the connection.

   (24) Guidance added to recommend ifLinkUpDownTrapEnable be set on.

   (25) Behavior of the PVC status and endpoint signaling status is
        clarified for the case of underlying layer failure.

   (26) Overview text re-written for clarity.

   (27) Clarified role of system group.

   (28) Established maximum frame size of 4096 and default value of
        1600.

   (29) Clarified that DLC index range is restricted to valid range for
        the specific length of address field used on the logical port.

   (30) Figure 1 and accompanying text was removed to eliminate a
        confusing "MIB stack" concept.  See the section titled "Relation
        to Other MIBs" for replacement text.

















Rehbehn & Fowler            Standards Track                    [Page 74]

RFC 2954                Frame Relay Service MIB             October 2000


Intellectual Property Rights

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementers or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.






























Rehbehn & Fowler            Standards Track                    [Page 75]

RFC 2954                Frame Relay Service MIB             October 2000


Full Copyright Statement

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.



















Rehbehn & Fowler            Standards Track                    [Page 76]