💾 Archived View for gemini.bortzmeyer.org › rfc-mirror › rfc6526.txt captured on 2023-06-16 at 18:05:41.

View Raw

More Information

⬅️ Previous capture (2021-11-30)

-=-=-=-=-=-=-







Internet Engineering Task Force (IETF)                         B. Claise
Request for Comments: 6526                                     P. Aitken
Category: Standards Track                                     A. Johnson
ISSN: 2070-1721                                      Cisco Systems, Inc.
                                                                G. Muenz
                                                             TU Muenchen
                                                              March 2012


                 IP Flow Information Export (IPFIX) Per
           Stream Control Transmission Protocol (SCTP) Stream

Abstract

   This document specifies an extension to the specifications in RFC
   5101, IP Flow Information Export (IPFIX), when using the Partial
   Reliability extension of SCTP (PR-SCTP, Partial Reliability Stream
   Control Transmission Protocol).

   When implemented at both the Exporting Process and Collecting
   Process, this method offers several advantages, such as the ability
   to calculate Data Record losses for PR-SCTP per Template, immediate
   export of Template Withdrawal Messages, immediate reuse of Template
   IDs within an SCTP stream, reduced likelihood of Data Record loss,
   and reduced demands on the Collecting Process.  When implemented in
   only the Collecting Process or Exporting Process, then normal IPFIX
   behavior will be seen without all of the additional benefits.

Status of This Memo

   This is an Internet Standards Track document.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Further information on
   Internet Standards is available in Section 2 of RFC 5741.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   http://www.rfc-editor.org/info/rfc6526.










Claise, et al.               Standards Track                    [Page 1]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


Copyright Notice

   Copyright (c) 2012 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.





































Claise, et al.               Standards Track                    [Page 2]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


Table of Contents

   1. Introduction ....................................................3
      1.1. Relationship with IPFIX and PSAMP ..........................4
      1.2. Applicability ..............................................5
      1.3. Limitations ................................................5
   2. Terminology .....................................................6
      2.1. Conventions Used in This Document ..........................6
      2.2. IPFIX Documents Overview ...................................6
      2.3. PSAMP Documents Overview ...................................7
   3. IPFIX Protocol Specifications: Limitations and Improvements .....7
      3.1. Data Record Loss Calculated Per Template ...................7
           3.1.1. IPFIX Protocol Specifications: Limitation ...........7
           3.1.2. IPFIX Export Per SCTP Stream: Advantage .............8
      3.2. Immediate Template Withdrawal and Reuse ....................8
           3.2.1. IPFIX Protocol Specifications: Limitation ...........8
           3.2.2. IPFIX Export Per SCTP Stream: Advantages ............9
      3.3. Requirement for Data Set Buffering .........................9
           3.3.1. IPFIX Protocol Specifications: Limitation ...........9
           3.3.2. IPFIX Export Per SCTP Stream: Advantages ...........10
   4. Specifications .................................................10
      4.1. New Information Element ...................................10
      4.2. Template Management .......................................11
      4.3. SCTP ......................................................12
      4.4. Template Withdrawal Message ...............................13
      4.5. The Collecting Process's Side .............................14
           4.5.1. SCTP ...............................................14
           4.5.2. Enabling the Per-SCTP-Stream Extension .............14
           4.5.3. Disabling the Per-SCTP-Stream Extension ............15
           4.5.4. Calculating Data Record Loss Per Template ..........16
   5. Resource Impact ................................................16
   6. Examples .......................................................17
   7. IANA Considerations ............................................20
   8. Security Considerations ........................................21
   9. References .....................................................21
      9.1. Normative References ......................................21
      9.2. Informative References ....................................21
   10. Acknowledgments ...............................................22

1.  Introduction

   The IPFIX protocol [RFC5101] has the goal of exporting Flow
   information.  This protocol is designed to export information about
   IP traffic Flows and related measurement data, where a Flow is
   defined by a set of key attributes (e.g., source and destination IP
   address, source and destination port, etc.).  However, thanks to its
   Template mechanism, the IPFIX protocol can export any type of




Claise, et al.               Standards Track                    [Page 3]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   information, as long as the relevant Information Element is specified
   in the IPFIX information model [RFC5102], registered with IANA
   [IANA], or specified as an enterprise-specific Information Element.

   The IPFIX protocol [RFC5101] specifies that traffic measurements for
   Flows are exported using a TLV (Type, Length, Value) format.  The
   information is exported using a Template Record, which is sent once
   to export the {Type, Length} pairs that define the data format for
   the Information Elements in a Flow.  The Data Records specify values
   for each Flow.

   The IPFIX protocol [RFC5101] is flexible: It foresees the usage of
   multiple SCTP streams per association; it allows the transmission of
   Data Sets, Template Sets, and/or Options Template Sets on any SCTP
   stream; it offers full and partially reliable export of Data Sets; it
   specifies both ordered and out-of-order delivery of Data Sets.
   However, due to bandwidth restrictions and packet losses in the
   network as well as resource constraints on the Exporter and Collector
   (e.g., limited buffer sizes), it is not always possible to export all
   Data Sets in a reliable way.

   This document specifies a method for exporting a Template Record and
   its associated Data Sets in a single SCTP stream, limiting each
   Template ID to a single SCTP stream if possible, and imposing
   in-order transmission.

   This method offers several advantages over IPFIX export as specified
   in [RFC5101], such as the ability to calculate Data Record losses for
   PR-SCTP per Template, immediate export of Template Withdrawal
   Messages, immediate reuse of Template IDs within an SCTP stream,
   reduced likelihood of Data Record loss, and reduced demands on the
   Collecting Process.

1.1.  Relationship with IPFIX and PSAMP

   The specifications in this document apply to the IPFIX protocol
   specifications [RFC5101].  However, they only apply to the SCTP
   transport protocol [RFC4960] option of the IPFIX protocol
   specifications (see Section 10 of [RFC5101]), specifically if the
   Partial Reliability extension [RFC3758] is used.  All specifications
   from [RFC5101] apply, unless specified otherwise in this document.

   As the Packet Sampling (PSAMP) protocol specifications [RFC5476] are
   based on the IPFIX protocol specifications, the specifications in
   this document are also valid for the PSAMP protocol.






Claise, et al.               Standards Track                    [Page 4]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


1.2.  Applicability

   The specifications contained in this document are applicable to cases
   where application requirements include knowing how many Data Records
   of a certain type (i.e., from a certain Template) were lost.  A
   typical example is a router exporting billing records, where the
   Exporting Process cannot afford to export all the Flow Records
   reliably, due to limited resources to buffer a large number of Flow
   Records.  Such a situation may occur if Data Sets are generated at a
   higher rate at the Exporter than can be transferred to the Collector
   because of bandwidth limitations in the network or slow reception at
   the Collector.

   To be more precise, the specification applicability is the case where
   multiple Templates are simultaneously active within a single SCTP
   Transport Session and the calculation of the Data Record loss for a
   particular Template is required.  Indeed, with the current IPFIX
   specifications [RFC5101], if an IPFIX Message is lost (UDP or SCTP
   partially reliable), it is not possible to determine to which
   Template(s) the lost Data Records belong.

   Exporting Processes following the specifications in this document
   will interoperate with existing Collecting Processes that comply with
   [RFC5101]; no changes are required at the Collecting Process to
   receive data from an Exporting Process compliant with this method.
   However, Collecting Processes may implement additional support for
   per-stream export specified in this document in order to realize all
   the benefits of the approach specified herein.  Since the
   specifications in this document mandate in-order transmission of
   (Options) Templates and associated Data Records, late arrival of
   (Options) Templates at the Collecting Process is avoided, which means
   that there are no Data Records that need to be dropped or buffered.

1.3.  Limitations

   When multiple Templates are required, this method requires multiple
   SCTP streams in the association between the Exporting Process and
   Collecting Process, ideally one stream per Template.  To properly
   handle the transmission of additional Templates during the Transport
   Session, additional SCTP streams are sometimes required.  These SCTP
   streams can only be added within the existing SCTP association if the
   specifications in [RFC6525] are supported.









Claise, et al.               Standards Track                    [Page 5]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


2.  Terminology

   IPFIX-specific terminology used in this document is defined in
   Section 2 of [RFC5101].  As in [RFC5101], these IPFIX-specific terms
   have the first letter of a word capitalized when used in this
   document.

   Note that, in this document, "(Options) Template" is used to refer to
   Templates and Options Templates.  Unless otherwise specified,
   "Template" alone refers to Templates exclusive of Options Templates.

   Template Reuse Delay

      The time the Exporting Process needs to wait after sending the
      last Data Set described by a given Template before sending a
      Template Withdrawal Message for the Template.  A suitable default
      value is 5 seconds, as specified in [RFC5101].

2.1.  Conventions Used in This Document

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].

2.2.  IPFIX Documents Overview

   The IPFIX protocol [RFC5101] provides network administrators with
   access to Flow information.

   The architecture for the export of measured Flow information out of
   an IPFIX Exporting Process to a Collecting Process is defined in the
   IPFIX architecture [RFC5470], per the requirements defined in
   [RFC3917].

   The IPFIX architecture [RFC5470] specifies how IPFIX Data Records and
   Templates are carried via a congestion-aware transport protocol from
   IPFIX Exporting Processes to IPFIX Collecting Processes.

   IPFIX has a formal description of IPFIX Information Elements, their
   names, their types, and additional semantic information, as specified
   in the IPFIX information model [RFC5102].

   Finally, the IPFIX applicability statement [RFC5472] describes what
   types of applications can use the IPFIX protocol and how they can use
   the information provided.  Furthermore, it shows how the IPFIX
   framework relates to other architectures and frameworks.





Claise, et al.               Standards Track                    [Page 6]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


2.3.  PSAMP Documents Overview

   The document "A Framework for Packet Selection and Reporting"
   [RFC5474] describes the Packet Sampling (PSAMP) framework for network
   elements to select subsets of packets by statistical and other
   methods, and to export a stream of reports on the selected packets to
   a Collector.

   The set of packet selection techniques (sampling, filtering, and
   hashing) supported by PSAMP are described in "Sampling and Filtering
   Techniques for IP Packet Selection" [RFC5475].

   The PSAMP protocol [RFC5476] specifies the export of packet
   information from a PSAMP Exporting Process to a PSAMP Collecting
   Process.  Like IPFIX, PSAMP has a formal description of its
   Information Elements, their names, their types, and additional
   semantic information.  The PSAMP information model is defined in
   [RFC5477].

3.  IPFIX Protocol Specifications: Limitations and Improvements

   For three specific topics ("Data Record Loss Calculated Per
   Template", "Immediate Template Withdrawal and Reuse", and
   "Requirement for Data Set Buffering"), this section explains the
   limitations of the IPFIX protocol specifications on the one hand, and
   the advantages of the method specified in this document on the other.

3.1.  Data Record Loss Calculated Per Template

3.1.1.  IPFIX Protocol Specifications: Limitation

   Section 6.3.2 of [RFC3917], "Requirements for IP Flow Information
   Export" discusses the data transfer reliability issues:

      Loss of flow records during the data transfer from the Exporting
      Process to the Collecting Process must be indicated at the
      Collecting Process.

   However, in some cases, it may be important to know how many Data
   Records of a certain type were lost (e.g., in the case of billing),
   and IPFIX does not conventionally provide this information.

   A Collecting Process can detect out-of-sequence, dropped, or
   duplicate IPFIX Messages by tracking the Sequence Number [RFC5101].
   Note that the Sequence Number field in the IPFIX Message header
   increases with the number of IPFIX Data Records within the SCTP
   stream, so loss will be detected per stream.




Claise, et al.               Standards Track                    [Page 7]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   The IPFIX protocol specifications [RFC5101] specify that Data Records
   defined by any Template may be sent on any SCTP stream.  As such, if
   there is more than one Template defined within the whole SCTP
   association, then there is no way of knowing with which Template any
   lost Data Record is associated.  This is true, no matter what
   convention the Exporting Process uses to send Data Records on
   different SCTP streams, as the protocol makes no guarantees.

   Note that a workaround allowed by the IPFIX specifications in
   [RFC5101] is to use only one Template Record per SCTP Transport
   Session, at the cost of multiplying the number of SCTP Transport
   Sessions when multiple Template Records are required.

3.1.2.  IPFIX Export Per SCTP Stream: Advantage

   Using the specifications in this document, it is guaranteed that any
   lost Data Records will be associated only with the Templates that are
   defined on that SCTP stream.  By defining only one Template per SCTP
   stream, it is ensured that any loss is associated with that single
   Template.  So, by exporting each Template and its corresponding Data
   Records in a separate SCTP stream from other Templates and Data
   Records, the loss pertaining to each specific Template can be deduced
   from the Sequence Number field in the IPFIX Message headers.

3.2.  Immediate Template Withdrawal and Reuse

3.2.1.  IPFIX Protocol Specifications: Limitation

   A Collecting Process must have received the Template Record
   associated with the Data Records to be able to decode the information
   in the Data Records.  [RFC5101] specifies the following:

      The Exporting Process SHOULD transmit the Template Set and Options
      Template Set in advance of any Data Sets that use that (Options)
      Template ID, to help ensure that the Collecting Process has the
      Template Record before receiving the first Data Record.

   The fact that the Collecting Process cannot decode the Data Records
   without the corresponding Template Record may result in Data Records
   being discarded by the Collecting Process, as specified in [RFC5101]:

      The Collecting Process normally receives Template Records from the
      Exporting Process before receiving Data Records.  The Data Records
      are then decoded and stored by the Collector.  If the Template
      Records have not been received at the time Data Records are
      received, the Collecting Process MAY store the Data Records for a
      short period of time and decode them after the Template Records
      are received.



Claise, et al.               Standards Track                    [Page 8]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


3.2.2.  IPFIX Export Per SCTP Stream: Advantages

   By exporting each Template Record and the corresponding Data Records
   within a single SCTP stream and imposing in-order transmission, the
   Template Record will always arrive before the associated Data
   Records.  Therefore, there is no risk that the Collecting Process
   discards Data Records while waiting for the Template Record to
   arrive.

   Furthermore, when reusing a Template ID within an SCTP stream, the
   Template Withdrawal Message will be guaranteed to arrive before the
   new definition of the Template, and therefore the Template Record may
   be sent directly after the Template Withdrawal Message.  In other
   words, the Template Reuse Delay restriction (5 seconds by default, as
   specified in [RFC5101]) does not need to be applied to Template ID
   reuse within the same SCTP stream.

   Another advantage of the new specifications in this document is a
   reduced load on the Collecting Process.  Indeed, the Collecting
   Process doesn't have to store the Data Records while waiting for the
   Template Record, as the transmission order is always guaranteed.
   This way, extra reliability of the Data Records is achieved without
   extra burden on the Collecting Process.

3.3.  Requirement for Data Set Buffering

3.3.1.  IPFIX Protocol Specifications: Limitation

   The fact that the protocol specifications in [RFC5101] are flexible
   in terms of SCTP stream(s) on which the Template Set, Options
   Template Set, and corresponding Data Sets are exported implies that
   the (Options) Template Record might be exported on a different SCTP
   stream than the corresponding Data Records.  This might cause Data
   Record loss in the Collecting Process, as ordered transmission across
   SCTP streams is not guaranteed.

   For example, a Template Record may be blocked pending reliable
   transmission on one SCTP stream while the corresponding Data Records
   may be transmitted immediately in another SCTP stream.  Also, due to
   different levels of SCTP stream congestion, it is possible that even
   if the Template Record and corresponding Data Records are sent
   reliably, Data Records sent on a different SCTP stream than the
   Template Record might still arrive before the Template Record.








Claise, et al.               Standards Track                    [Page 9]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


3.3.2.  IPFIX Export Per SCTP Stream: Advantages

   By exporting each Template Record and all corresponding Data Records
   within a single SCTP stream, and imposing in-order transmission, the
   issue of ordered transmission across multiple SCTP streams is
   avoided.

   By exporting all corresponding Data Records within the same ordered
   SCTP stream as the Template Record, each SCTP stream is independent
   and self-contained, and the interaction between SCTP streams is
   limited to that of the Options Template and associated Data Records
   sent in different streams.  This has several advantageous
   consequences, including order preservation that does not result in
   the blocking of unrelated data, and load reduction on the Collecting
   Process (as the Template Records are guaranteed to be delivered
   before the associated Data Records, there is no need for the
   buffering of Data Sets that correspond with Templates that are
   missing).

4.  Specifications

   This section specifies Exporting Process and Collecting Process
   behavior different from that in [RFC5101] in order to realize the
   benefits of per-stream export.  Note that Exporting Processes
   following these specifications will interoperate with [RFC5101]-
   compliant Collecting Processes, but that Collecting Processes will
   have to follow additional non-interoperable specifications to realize
   the full benefits of the technique.  These new specifications, which
   add to those in [RFC5101], are described with the key words defined
   in [RFC2119].

4.1.  New Information Element

   dataRecordsReliability

      Description:
         The export reliability of Data Records, within this SCTP
         stream, for the element(s) in the Options Template scope.  A
         typical example of an element for which the export reliability
         will be reported is the Template ID, as specified in the Data
         Records Reliability Options Template.  A value of 'True' means
         that the Exporting Process MUST send any Data Records
         associated with the element(s) reliably within this SCTP
         stream.  A value of 'False' means that the Exporting Process
         MAY send any Data Records associated with the element(s)
         unreliably within this SCTP stream.





Claise, et al.               Standards Track                   [Page 10]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


      Abstract Data Type: boolean
      Data Type Semantics: identifier
      ElementId: 276
      Status: current

   Per Section 6.1.5 of [RFC5101], the boolean data type is encoded as a
   single octet, with the value of 1 for True and the value of 2 for
   False.

4.2.  Template Management

   To take advantage of per-stream export, Exporting Processes MUST
   follow the specification in this section in addition to Section 8,
   "Template Management", of [RFC5101].

   As specified in [RFC5101], Template Sets and Options Template Sets
   MUST be sent reliably.

   Any Data Sets associated with a Template Record MUST be sent on the
   same SCTP stream on which the Template Record was sent.

   The Data Records Reliability Options Template is used to explicitly
   inform the Collecting Process which Templates will be used in each
   SCTP stream and whether each set of associated Data Records will be
   sent reliably or unreliably.  After defining a Template ID and before
   sending any associated Data Records on an SCTP stream, the Exporting
   Process MUST notify the Collecting Process of its intention to send
   those Data Records reliably or unreliably within that SCTP stream.
   It does this by sending a Data Record defined by the Data Records
   Reliability Options Template for the Template associated with the
   Data Records to be sent.  If it does not, then the Collecting Process
   MUST disable this extension for the SCTP association.  The one
   exception to this rule is that the Data Records associated with the
   Data Records Reliability Options Template don't require an explicit
   notification, as these MUST always be sent reliably.

   The Data Records Reliability Options Template MUST contain the
   following Information Elements:

      Scope:     Template ID
      Non-scope: dataRecordsReliability

   After sending a value of 'True' for the dataRecordsReliability
   Element, the Exporting Process MUST send any Data Records associated
   with the currently defined Template ID reliably within this SCTP
   stream.  After sending a value of 'False' for the





Claise, et al.               Standards Track                   [Page 11]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   dataRecordsReliability Element, the Exporting Process MAY send any
   Data Records associated with the Template ID unreliably within this
   SCTP stream.

   If the Exporting Process wants to change the Data Records Reliability
   value (from reliable to unreliable, or vice versa) for Data Records
   on an SCTP stream, the Template MUST be withdrawn, and a new Template
   MUST be used.

   The Data Records Reliability Options Template MAY contain other
   non-scope Information Elements associated with the (Options)
   Template.

   When an Options Template (including the Data Records Reliability
   Options Template) and associated Data Records are sent in the same
   SCTP stream, the first associated Data Record can follow the Options
   Template immediately.  When the Options Template and associated Data
   Records are sent in different SCTP streams, the Exporting Process
   SHOULD transmit the Options Template in advance of any Data Sets that
   use it, to help ensure that the Collector has received the Options
   Template Record before receiving the first associated Data Record.

   It is RECOMMENDED that the Exporting Process only sends a single
   Template and corresponding Data Sets within a single SCTP stream in
   order to enable calculation of the potential Data Record loss for
   this Template.  The Exporting Process MAY group related (Options)
   Templates and their associated Data Records within a single SCTP
   stream so that loss statistics are calculated for the group of
   Templates that are being sent unreliably within the SCTP stream.
   This is suitable in cases where there are only slight variations
   among the Templates in a group (e.g., the omission of unavailable
   fields for export efficiency) and may be necessary if the SCTP
   association does not support enough SCTP streams to export each
   Template in its own SCTP stream.

   If an SCTP stream contains a mixture of Data Records defined by
   Template Records and by Options Template Records, the Data Records
   defined by the Options Template Records SHOULD be sent reliably so
   that the Collecting Process does not consider any loss to be
   associated with the Options Data Records.

4.3.  SCTP

   To take advantage of per-stream export, Exporting Processes MUST
   manage SCTP streams according to the specification in this section,
   in addition to Section 10.2.4.3, "Stream", of [RFC5101].





Claise, et al.               Standards Track                   [Page 12]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   PR-SCTP [RFC3758] MUST be implemented by all compliant
   implementations.

   All IPFIX Messages in an SCTP stream MUST be sent in order.

   As specified in [RFC5101], depending on the requirements of the
   application, the Exporting Process may send Data Sets with full or
   partial reliability.

   If the Exporting Process is required to export a new Template Record
   but there are no more free SCTP streams available, it SHOULD attempt
   to increase the number of outbound SCTP streams to which it is able
   to send, per [RFC6525].  Alternatively, the Exporting Process MAY add
   the Template Set and Data Records to an existing SCTP stream at the
   cost of diluting the granularity of any Data Record loss attribution.
   An alternative that may result in the loss of Flow Records (for
   example, due to lack of buffering on the Exporter) is to restart the
   SCTP association with an increased number of SCTP streams.

4.4.  Template Withdrawal Message

   To take advantage of per-stream export, Exporting Processes MUST send
   Template Withdrawal Messages according to the specification in this
   section, in addition to Section 8, "Template Management", of
   [RFC5101].

   As specified in [RFC5101], Templates that are no longer in use SHOULD
   be deleted.  Before reusing a Template ID, the Template MUST be
   deleted.  In order to delete an allocated Template, the Template is
   withdrawn through the use of a Template Withdrawal Message.

   The Template Withdrawal Message MUST be sent on the same SCTP stream
   as the associated Template Record.

   The Template Withdrawal Message MUST be sent reliably, using SCTP-
   ordered delivery per [RFC5101].  As all IPFIX Messages are sent in
   order within an SCTP stream (per the specifications in this
   document), the IPFIX Message containing the Template Withdrawal
   Message will not arrive at the Collecting Process before any
   associated and previously sent Data Record.  As a consequence, no
   Data Records will be lost due to delayed arrival at the Collecting
   Process.

   The Template ID from a withdrawn Template MAY be reused on the same
   SCTP stream immediately after the Template Withdrawal Message is
   sent.  This case is equivalent to the use of a Template Reuse Delay
   value of 0.




Claise, et al.               Standards Track                   [Page 13]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   After reusing the Template ID, the Exporting Process MUST send a Data
   Record associated with the Data Records Reliability Options Template
   to specify the reliability level of the Data Records associated with
   the new Template.

   If the Template ID is to be reused on a different SCTP stream, the
   new Template Record MUST NOT be sent before the Template Reuse Delay
   interval.

   A Template Withdrawal Message to withdraw all Templates for the
   Observation Domain ID specified in the IPFIX Message header MUST NOT
   be used.

   Multiple Template IDs MAY be withdrawn with a single Template
   Withdrawal Message under the condition that all the Template IDs in
   the Template Withdrawal Message are used on the same SCTP stream as
   the Template Withdrawal Message.

4.5.  The Collecting Process's Side

   Collecting Processes must operate in a fashion slightly contrary to
   [RFC5101] in order to realize the full benefits of per-stream export.
   However, the specification in this section contains a mechanism that
   allows per-stream-capable Collecting Processes to selectively enable
   per-stream export, in order to ensure interoperability of per-stream-
   capable Collecting Processes with Exporting Processes that do not
   implement per-stream export.

4.5.1.  SCTP

   As specified in [RFC5101], the Collecting Process SHOULD listen for a
   new association request from the Exporting Process.  The Exporting
   Process will request a number of SCTP streams to use for export.

   A Collecting Process SHOULD support the procedure for the addition of
   an SCTP stream specified in [RFC6525].

4.5.2.  Enabling the Per-SCTP-Stream Extension

   In IPFIX, there is no explicit notification of the Exporting
   Process's capabilities.  There is also no return channel for the
   Collecting Process to communicate its capabilities.

   When the Exporting Process is sending according to the per-SCTP-
   stream extension, the first Data Record received by the Collecting
   Process will be associated with the Data Records Reliability Options





Claise, et al.               Standards Track                   [Page 14]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   Template.  In this case, the Collecting Process enables the extension
   for this Transport Session.  Otherwise, the Collecting Process MUST
   NOT enable the extension for this Transport Session.

   The Collecting Process MUST accept other non-scope Information
   Elements in the Data Records Reliability Options Template.

4.5.3.  Disabling the Per-SCTP-Stream Extension

   Nothing prevents an implementation that does not meet the
   specification of the per-SCTP-stream extension from sending a
   Template that looks like a dataRecordsReliability Options Template.
   Therefore, a Collecting Process MUST detect if the Exporting Process
   fails to meet the specification fully.  If any of the conditions
   below is met, the Exporting Process does not properly use the
   per-SCTP-stream extension, and the Collecting Process MUST log an
   error message and disable this extension for the SCTP association.

      1. A Data Record is received before the appropriate Data Record
         associated with the Data Records Reliability Options Template
         has been received on the same SCTP stream (see Section 4.2).
         Note: Data Records associated with the Data Records Reliability
         Options Template are an exception to this rule.

      2. A Data Record associated with a Data Records Reliability
         Options Template is received on an SCTP stream for a
         (non-Options) Template that was defined on a different SCTP
         stream.

      3. A second Data Record associated with the Data Records
         Reliability Options Template is received for the same (Options)
         Template.

      4. A Data Record or a Template Withdrawal Message is associated
         with a Template that was defined on a different SCTP stream.

      5. Loss of Data Records is detected within a stream where a Data
         Record associated with the Data Records Reliability Options
         Template indicating unreliable transmission for any Template
         has not been received.

      6. A message is received with the SCTP U(nordered) flag set to 1
         (i.e., the message was sent unordered), even if it is processed
         in order.







Claise, et al.               Standards Track                   [Page 15]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


4.5.4.  Calculating Data Record Loss Per Template

   As specified in [RFC5101], the IPFIX protocol has a Sequence Number
   field in the IPFIX Message header that increases with the number of
   IPFIX Data Records in the IPFIX Message.  A Collecting Process may
   detect out-of-sequence, dropped, or duplicate IPFIX Messages by
   tracking the Sequence Number.

   When one or more sequential IPFIX Messages are considered lost, the
   number of lost Data Records is equal to the Sequence Number of the
   first IPFIX Message Header following the lost packets (S2) minus the
   Sequence Number of the first lost IPFIX Message (S1).  The Sequence
   Number of the first lost IPFIX Message can be calculated as the
   Sequence Number of the last IPFIX Message before the sequence of lost
   IPFIX Messages (S0) plus the number of Data Records in that IPFIX
   Message (N0).

      S1 = S0 + N0
      loss = (S2 - S1) (mod(2^32))
           = (S2 - (S0 + N0)) (mod(2^32))

   Note that modulo 2^32 arithmetic is required, since the Sequence
   Number may wrap within the series of lost IPFIX Messages.  If less
   than 2^32 Data Records are lost in a sequence (which can be assumed
   in practice), the above equation returns the exact number of lost
   Data Records.

   Note that using an unsigned32 type for the loss would automatically
   take care of the mod(2^32) operation.

   As this Sequence Number is incremented per SCTP stream, the loss of
   Data Records sent in that SCTP stream can be calculated in the case
   of partially reliable export.  This loss can be attributed to the
   Data Records sent for the (Options) Template(s) whose records are
   being sent unreliably within that SCTP stream.

5.  Resource Impact

   Although adding the new SCTP streams requires a message exchange, it
   is more lightweight to set up additional SCTP streams than to set up
   a new SCTP association, since the only overhead of adding SCTP
   stream(s) to an existing SCTP association is the addition of 16-24
   more bytes (allocated in the SCTP association, a single time),
   whereas setting up a new SCTP association requires more overhead.

   In terms of throughput impact, the fact that these specifications
   discourage multiplexing Templates and Data Records of different
   Template IDs may lead to a slightly larger IPFIX Message overhead.



Claise, et al.               Standards Track                   [Page 16]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   If the Data Record rate is low for a specific Template (and hence a
   specific SCTP stream), the Exporting Process might not be able to
   fill the IPFIX Messages with Data Records associated with other
   Templates.  In such a situation, there is a potential overhead due to
   additional IPFIX Message headers and SCTP chunk headers.

   Finally, with respect to the processing overhead on the Exporter, a
   lot of state information must be stored when a large number of SCTP
   streams are used within an SCTP association.  However, no comparison
   of the performance impact of multiple streams within an SCTP
   association versus opening the same number of independent SCTP
   associations is available.

6.  Examples

   Figure 1 shows an example where SCTP stream 10 carries a Template
   Record with Template ID 257 transmitted with full reliability (FR),
   together with associated Data Records transmitted with partial
   reliability (PR).  The Data Records Reliability Options Template with
   Template ID 256 is transmitted with full reliability.  Its
   corresponding Data Set contains one Data Record.

   Record 1:

      o Scope:     Template ID = 257
      o Non-scope: dataRecordsReliability = False

                      +--------+       +---------+   +--------+
                      |        |       |         |   |        |
        stream 10 ----| Data   | . . . |  Data   |---| Data   |---...
                      |   257  |       |    257  |   |   256  |
                      |      PR|       |       PR|   |      FR|
                      +--------+       +---------+   +--------+

                             +----------+       +-------------+
                             |          |       | Reliability |
                             |          |       | Options     |
                       ...---| Template |-------| Template    |------>
                             |     257  |       |        256  |
                             |        FR|       |           FR|
                             +----------+       +-------------+

                                 Figure 1








Claise, et al.               Standards Track                   [Page 17]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   Note that Template 257 will always be processed before the Data
   Records by the Collecting Process, because all IPFIX Messages are
   sent in order within an SCTP stream.  Therefore, the job of the
   Collecting Process is simplified.  Furthermore, the Data Record loss
   for Template 257 can easily be calculated by the Collecting Process.

   If an Options Template is necessary to understand the content of a
   Data Record (i.e., the scope in the Options Template Record is an
   Information Element contained in the Data Record or associated with
   the Data Record), the Options Template Record should be sent in the
   same SCTP stream, as displayed in Figure 2.

                       +--------+   +--------+     +--------+
                       |        |   |        |     |        |
         stream 20 ----| Data   |...| Data   |-----| Data   |--- ...
                       |   260  |   |   260  |     |   259  |
                       |      PR|   |      PR|     |      FR|
                       +--------+   +--------+     +--------+

                              +--------+       +----------+
                              |        |       |          |
                        ...---| Data   |-------| Template |---...
                              |   258  |       |     260  |
                              |      FR|       |        FR|
                              +--------+       +----------+

                           +----------+       +-------------+
                           | Options  |       | Reliability |
                           | Template |       | Options     |
                     ...---|          |-------| Template    |------>
                           |     259  |       |        258  |
                           |        FR|       |           FR|
                           +----------+       +-------------+

                                 Figure 2

   Figure 2 shows an example where SCTP stream 20 carries the following:

   -  a Data Records Reliability Options Template with Template ID 258,
      transmitted with full reliability.

   -  an Options Template Record with Template ID 259, transmitted with
      full reliability.  This Options Template Record contains
      additional information related to the subsequent Data Records
      based on Template ID 260.  Typical examples are the Common
      Properties information [RFC5473] or the Selector Report
      Interpretation [RFC5476].




Claise, et al.               Standards Track                   [Page 18]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   -  a Template Record with Template ID 260, transmitted with full
      reliability.

   -  a Data Set specified by the Reliability Options Template with
      Template ID 258, transmitted with full reliability.

      The Data Set contains three Data Records:

      Record 1:
         o Scope:     Template ID = 258
         o Non-scope: dataRecordsReliability = True

      Record 2:
         o Scope:     Template ID = 259
         o Non-scope: dataRecordsReliability = True

      Record 3:
         o Scope:     Template ID = 260
         o Non-scope: dataRecordsReliability = False

      These Data Records inform the Collecting Process that the Data
      Records for Template IDs 258 and 259 are sent reliably, while the
      Data Records for Template ID 260 are not.  Note that the first
      Data Record associated with the Data Record Reliability Options
      Template (Template ID 258) is not required and can be omitted.

   -  a Data Record specified by Template ID 259, transmitted with full
      reliability.

   -  a Data Record specified by Template ID 260, transmitted with
      partial reliability.

   If the Collecting Process observes some Data Record loss using the
   Sequence Number, the loss can only stem from the Data Records
   associated with Template ID 260, as these are the only Data Records
   not exported reliably.  Therefore, the calculation of loss per
   Template ID 260 is possible.

   Note that Options Templates 258, 259, and 260 will always arrive
   before their associated Data Records, respectively, because all IPFIX
   Messages must be sent in order within an SCTP stream.










Claise, et al.               Standards Track                   [Page 19]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   Figure 3 shows an example where SCTP stream 30 carries a Template
   Record with Template ID 262 transmitted with full reliability, an
   associated Data Record transmitted with full reliability, and a
   Template Withdrawal Message, followed by a redefinition of Template
   ID 262, and finally the Data Record associated with the new Template
   transmitted with partial reliability.  The Template Withdrawal
   Message and the new definition of Template ID 262 are sent
   immediately, without waiting for the Template Reuse Delay interval.

                       +--------+   +----------+     +----------+
                       |        |   |Data      |     |          |
      stream 30 ... ---| Data   |...|  261     |-----| Template |---
                       |   262  |   |tmpID: 262|     |    262   |
                       |      PR|   |dRR: False|     |        FR|
                       +--------+   +----------+     +----------+

                 +----------+     +--------+       +----------+
                 | Template |     |        |       | Data     |
              ...| Withdraw |-----| Data   |-------|   261    |---...
                 |    262   |     |   262  |       |tmpID: 262|
                 |        FR|     |      FR|       |dRR:  True|
                 +----------+     +--------+       +----------+

                           +----------+       +-------------+
                           |          |       | Reliability |
                           | Template |       | Options     |
                     ...---|          |-------| Template    |------>
                           |     262  |       |        261  |
                           |        FR|       |           FR|
                           +----------+       +-------------+

              dRR: Data Records Reliability

                                 Figure 3

   The second Data Record associated with the Data Records Reliability
   Options Template shows that the Data Records associated with the
   newly specified Template ID 262 will be sent unreliably.

7.  IANA Considerations

   According to the process defined in [RFC5102], IANA has allocated the
   dataRecordsReliability Information Element (defined in Section 4.1)
   in the "IPFIX Information Elements" registry [IANA].







Claise, et al.               Standards Track                   [Page 20]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


8.  Security Considerations

   The same security considerations as for the IPFIX protocol [RFC5101]
   apply.

9.  References

9.1.  Normative References

   [RFC2119]   Bradner, S., "Key words for use in RFCs to Indicate
               Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC3758]   Stewart, R., Ramalho, M., Xie, Q., Tuexen, M., and P.
               Conrad, "Stream Control Transmission Protocol (SCTP)
               Partial Reliability Extension", RFC 3758, May 2004.

   [RFC4960]   Stewart, R., Ed., "Stream Control Transmission Protocol",
               RFC 4960, September 2007.

   [RFC5101]   Claise, B., Ed., "Specification of the IP Flow
               Information Export (IPFIX) Protocol for the Exchange of
               IP Traffic Flow Information", RFC 5101, January 2008.

   [RFC5102]   Quittek, J., Bryant, S., Claise, B., Aitken, P., and J.
               Meyer, "Information Model for IP Flow Information
               Export", RFC 5102, January 2008.

   [RFC5475]   Zseby, T., Molina, M., Duffield, N., Niccolini, S., and
               F. Raspall, "Sampling and Filtering Techniques for IP
               Packet Selection", RFC 5475, March 2009.

   [RFC6525]   Stewart, R., Tuexen, M., and P. Lei, "Stream Control
               Transmission Protocol (SCTP) Stream Reconfiguration",
               RFC 6525, February 2012.

9.2.  Informative References

   [IANA] IPFIX Information Elements Registry,
               <http://www.iana.org/assignments/ipfix>.

   [RFC3917]   Quittek, J., Zseby, T., Claise, B., and S. Zander,
               "Requirements for IP Flow Information Export (IPFIX)",
               RFC 3917, October 2004.

   [RFC5470]   Sadasivan, G., Brownlee, N., Claise, B., and J. Quittek,
               "Architecture for IP Flow Information Export", RFC 5470,
               March 2009.




Claise, et al.               Standards Track                   [Page 21]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


   [RFC5472]   Zseby, T., Boschi, E., Brownlee, N., and B. Claise, "IP
               Flow Information Export (IPFIX) Applicability", RFC 5472,
               March 2009.

   [RFC5473]   Boschi, E., Mark, L., and B. Claise, "Reducing Redundancy
               in IP Flow Information Export (IPFIX) and Packet Sampling
               (PSAMP) Reports", RFC 5473, March 2009.

   [RFC5474]   Duffield, N., Ed., Chiou, D., Claise, B., Greenberg, A.,
               Grossglauser, M., and J. Rexford, "A Framework for Packet
               Selection and Reporting", RFC 5474, March 2009.

   [RFC5476]   Claise, B., Ed., Johnson, A., and J. Quittek, "Packet
               Sampling (PSAMP) Protocol Specifications", RFC 5476,
               March 2009.

   [RFC5477]   Dietz, T., Claise, B., Aitken, P., Dressler, F., and G.
               Carle, "Information Model for Packet Sampling Exports",
               RFC 5477, March 2009.

10.  Acknowledgments

   The authors would like to thank Brian Trammell for his expert
   feedback and continuous effort to improve the specifications; Elisa
   Boschi for her thorough reading; Randall Stewart, Peter Lei, and
   Michael Tuexen for their SCTP-related feedback and expertise; and
   Tobias Limmer.
























Claise, et al.               Standards Track                   [Page 22]

RFC 6526                  IPFIX Per SCTP Stream               March 2012


Authors' Addresses

   Benoit Claise
   Cisco Systems, Inc.
   De Kleetlaan 6a b1
   Diegem 1813
   Belgium

   Phone: +32 2 704 5622
   EMail: bclaise@cisco.com


   Paul Aitken
   Cisco Systems, Inc.
   96 Commercial Quay
   Commercial Street
   Edinburgh, EH6 6LX, United Kingdom

   Phone: +44 131 561 3616
   EMail: paitken@cisco.com


   Andrew Johnson
   Cisco Systems, Inc.
   96 Commercial Quay
   Commercial Street
   Edinburgh, EH6 6LX, United Kingdom

   Phone: +44 131 561 3641
   EMail: andrjohn@cisco.com


   Gerhard Muenz
   Technische Universitaet Muenchen
   Department of Informatics - I8
   Boltzmannstr. 3
   Garching D-85748
   DE

   EMail: muenz@net.in.tum.de
   URI: http://www.net.in.tum.de/~muenz










Claise, et al.               Standards Track                   [Page 23]