💾 Archived View for gmi.noulin.net › rfc › rfc3896.gmi captured on 2023-06-16 at 23:45:03. Gemini links have been rewritten to link to archived content
⬅️ Previous capture (2023-01-29)
-=-=-=-=-=-=-
Obsoletes:
Keywords: DS3-E3-MIB, management information base, Interface Type
Network Working Group O. Nicklass, Ed. Request for Comments: 3896 RAD Data Communications, Ltd. Obsoletes: 2496 September 2004 Category: Standards Track Definitions of Managed Objects for the DS3/E3 Interface Type Status of this Memo This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited. Copyright Notice Copyright (C) The Internet Society (2004). Abstract This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes objects used for managing DS3 and E3 interfaces. This document is a companion to the documents that define Managed Objects for the DS0, DS1/E1/DS2/E2 and Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) Interface Types. This document obsoletes RFC 2496. Table of Contents 1. The Internet Standard Management Framework. . . . . . . . . . 2 1.1. Changes from RFC 2496 . . . . . . . . . . . . . . . . . 2 1.2. Changes from RFC 1407 . . . . . . . . . . . . . . . . . 3 1.3. Companion Documents . . . . . . . . . . . . . . . . . . 4 2. Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.1. Use of ifTable for DS3 Layer . . . . . . . . . . . . . 4 2.2. Usage Guidelines. . . . . . . . . . . . . . . . . . . . 5 2.2.1. Usage of ifStackTable . . . . . . . . . . . . . 5 2.2.2. Usage of Channelization for DS3, DS1, DS0 . . . 7 2.2.3. Usage of Channelization for DS3, DS2, DS1 . . . 8 2.2.4. Usage of Loopbacks . . . . . . . . . . . . . . 9 2.3. Objectives of this MIB Module . . . . . . . . . . . . . 10 2.4. DS3/E3 Terminology . . . . . . . . . . . . . . . . . . 10 2.4.1. Error Events. . . . . . . . . . . . . . . . . . 10 2.4.2. Performance Parameters. . . . . . . . . . . . . 11 2.4.3. Performance Defects . . . . . . . . . . . . . . 14 Nicklass Standards Track [Page 1] RFC 3896 DS3/E3 MIB September 2004 2.4.4. Other Terms . . . . . . . . . . . . . . . . . . 16 3. Object Definitions . . . . . . . . . . . . . . . . . . . . . . 16 4. Appendix A - Use of the dsx3IfIndex and dsx3LineIndex. . . . . 54 5. Appendix B - The delay approach to Unavailable Seconds . . . . 56 6. Acknowledgments. . . . . . . . . . . . . . . . . . . . . . . . 58 7. References . . . . . . . . . . . . . . . . . . . . . . . . . . 58 7.1. Normative References . . . . . . . . . . . . . . . . . . 58 7.2. Informative References . . . . . . . . . . . . . . . . . 59 8. Security Considerations. . . . . . . . . . . . . . . . . . . . 60 9. Author's Address . . . . . . . . . . . . . . . . . . . . . . . 62 10. Full Copyright Statement . . . . . . . . . . . . . . . . . . . 63 1. The Internet Standard Management Framework For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 [RFC3410]. Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580]. 1.1. Changes from RFC 2496 The changes from [RFC2496] are the following: (1) The dsx3FracIfIndex SYNTAX matches the description range. (2) Reference was added to Circuit Identifier object. (3) Usage of ifStackTable section was updated. (4) Align the DESCRIPTION clauses of few statistic objects with the near end definition, the far end definition and with [RFC3593]. (5) Add new value, dsx3M13, to dsx3LineType. Nicklass Standards Track [Page 2] RFC 3896 DS3/E3 MIB September 2004 1.2. Changes from RFC 1407 The changes from RFC 1407 are the following: (1) The Fractional Table has been deprecated. (2) This document uses SMIv2. (3) Values are given for ifTable and ifXTable. (4) Example usage of ifStackTable is included. (5) dsx3IfIndex has been deprecated. (6) The definition of valid intervals has been clarified for the case where the agent proxied for other devices. In particular, the treatment of missing intervals has been clarified. (7) An inward loopback has been added. (8) Additional lineStatus bits have been added for Near End in Unavailable Signal State, Carrier Equipment Out of Service. (9) A read-write line Length object has been added. (10) Added a lineStatus last change, trap and enabler. (11) Textual Conventions for statistics objects have been used. (12) A new object, dsx3LoopbackStatus, has been introduced to reflect the loopbacks established on a DS3/E3 interface and the source to the requests. dsx3LoopbackConfig continues to be the desired loopback state while dsx3LoopbackStatus reflects the actual state. (13) A dual loopback has been added to allow the setting of an inward loopback and a line loopback at the same time. (14) An object has been added to indicated whether or not this is a channelized DS3/E3. (15) A new object has been added to indicate which DS1 is to set for remote loopback. Nicklass Standards Track [Page 3] RFC 3896 DS3/E3 MIB September 2004 1.3. Companion Documents This document is a companion to the documents that define Managed Objects for the DS0 [RFC2494], DS1/E1/DS2/E2 [RFC3895], and Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) [RFC3592] Interface Types. 2. Overview These objects are used when the particular media being used to realize an interface is a DS3/E3 interface. At present, this applies to these values of the ifType variable in the Internet-standard MIB: ds3 (30) The DS3 definitions contained herein are based on the DS3 specifications in ANSI T1.102-1987 [ANSI-T1.102], ANSI T1.107-1988 [ANSI-T1.107], ANSI T1.107a-1990 [ANSI-T1.107a], and ANSI T1.404-1989 [ANSI-T1.404]. The E3 definitions contained herein are based on the E3 specifications in CCITT G.751 [CCITT-G.751] and ETSI T/NA(91)18 [ETSI-T/NA(91)18]. 2.1. Use of ifTable for DS3 Layer Only the ifGeneralInformationGroup needs to be supported. ifTable Object Use for DS3 Layer =================================================================== ifIndex Interface index. ifDescr See interfaces MIB [RFC2863] ifType ds3(30) ifSpeed Speed of line rate DS3 - 44736000 E3 - 34368000 ifPhysAddress The value of the Circuit Identifier. If no Circuit Identifier has been assigned this object should have an octet string with zero length. ifAdminStatus See interfaces MIB [RFC2863] ifOperStatus See interfaces MIB [RFC2863] ifLastChange See interfaces MIB [RFC2863] Nicklass Standards Track [Page 4] RFC 3896 DS3/E3 MIB September 2004 ifName See interfaces MIB [RFC2863] ifLinkUpDownTrapEnable Set to enabled(1). ifHighSpeed Speed of line in Mega-bits per second (either 45 or 34) ifConnectorPresent Set to true(1) normally, except for cases such as DS3/E3 over AAL1/ATM where false(2) is appropriate 2.2. Usage Guidelines 2.2.1. Usage of ifStackTable The object dsx3IfIndex has been deprecated. This object previously allowed a very special proxy situation to exist for Routers and CSUs. This section now describes how to use ifStackTable to represent this relationship. The paragraphs discussing dsx3IfIndex and dsx3LineIndex have been preserved in Appendix A for informational purposes. The ifStackTable is used in the proxy case to represent the association between pairs of interfaces, e.g., this DS3 is attached to that DS3. This use is consistent with the use of the ifStackTable to show the association between various sub-layers of an interface. In both cases entire PDUs are exchanged between the interface pairs - in the case of a DS3, entire DS3 frames are exchanged; in the case of PPP and HDLC, entire HDLC frames are exchanged. This usage is not meant to suggest the use of the ifStackTable to represent Time Division Multiplexing (TDM) connections in general. External&Internal interface scenario: the SNMP Agent resides on a host external from the device supporting DS3/E3 interfaces (e.g., a router). The Agent represents both the host and the DS3/E3 device. Nicklass Standards Track [Page 5] RFC 3896 DS3/E3 MIB September 2004 Example: A shelf full of CSUs connected to a Router. An SNMP Agent residing on the router proxies for itself and the CSU. The router has also an Ethernet interface: +-----+ | | | | | | +---------------------+ |E | | 44.736 MBPS | ds3 M13 Line#A | ds3 C-bit Parity |t | R |---------------+ - - - - - - - - - +------> |h | | | | |e | O | 44.736 MBPS | ds3 M13 Line#B | ds3 C-bit Parity |r | |---------------+ - - - - - - - - - - +------> |n | U | | | |e | | 44.736 MBPS | ds3 M13 Line#C | ds3 C-bit Parity |t | T |---------------+ - - - -- -- - - - - +------> | | | | | |-----| E | 44.736 MBPS | ds3 M13 Line#D | ds3 C-bit Parity | | |---------------+ - - - - -- - - - - +------> | | R | |_____________________| | | | | +-----+ The assignment of the index values could for example be: ifIndex Description 1 Ethernet 2 Line#A Router 3 Line#B Router 4 Line#C Router 5 Line#D Router 6 Line#A CSU Router 7 Line#B CSU Router 8 Line#C CSU Router 9 Line#D CSU Router 10 Line#A CSU Network 11 Line#B CSU Network 12 Line#C CSU Network 13 Line#D CSU Network Nicklass Standards Track [Page 6] RFC 3896 DS3/E3 MIB September 2004 The ifStackTable is then used to show the relationships between the various DS3 interfaces. ifStackTable Entries HigherLayer LowerLayer 2 6 3 7 4 8 5 9 6 10 7 11 8 12 9 13 If the CSU shelf is managed by itself by a local SNMP Agent, the situation would be identical, except the Ethernet and the 4 router interfaces are deleted. Interfaces would also be numbered from 1 to 8. ifIndex Description 1 Line#A CSU Router 2 Line#B CSU Router 3 Line#C CSU Router 4 Line#D CSU Router 5 Line#A CSU Network 6 Line#B CSU Network 7 Line#C CSU Network 8 Line#D CSU Network ifStackTable Entries HigherLayer LowerLayer 1 5 2 6 3 7 4 8 2.2.2. Usage of Channelization for DS3, DS1, DS0 An example is given here to explain the channelization objects in the DS3, DS1, and DS0 MIBs to help the implementor use the objects correctly. Treatment of E3 and E1 would be similar, with the number of DS0s being different depending on the framing of the E1. Nicklass Standards Track [Page 7] RFC 3896 DS3/E3 MIB September 2004 Assume that a DS3 (with ifIndex 1) is Channelized into DS1s (without DS2s). The object dsx3Channelization is set to enabledDs1. When this object is set to enabledDS1, 28 ifEntries of type DS1 will be created by the agent. If dsx3Channelization is set to disabled, then the DS1s are destroyed. Assume the entries in the ifTable for the DS1s are created in channel order and the ifIndex values are 2 through 29. In the DS1 MIB, there will be an entry in the dsx1ChanMappingTable for each ds1. The entries will be as follows: dsx1ChanMappingTable Entries ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex 1 1 2 1 2 3 ...... 1 28 29 In addition, the DS1s are channelized into DS0s. The object dsx1Channelization is set to enabledDS0 for each DS1. There will be 24 DS0s in the ifTable for each DS1. Assume the entries in the ifTable are created in channel order and the ifIndex values for the DS0s in the first DS1 are 30 through 53. In the DS0 MIB [RFC2494], there will be an entry in the dsx0ChanMappingTable for each DS0. The entries will be as follows: dsx0ChanMappingTable Entries ifIndex dsx0Ds0ChannelNumber dsx0ChanMappedIfIndex 2 1 30 2 2 31 ...... 2 24 53 2.2.3. Usage of Channelization for DS3, DS2, DS1 An example is given here to explain the channelization objects in the DS3 and DS1 MIBs to help the implementor use the objects correctly. Assume that a DS3 (with ifIndex 1) is Channelized into DS2s. The object dsx3Channelization is set to enabledDs2. There will be 7 DS2s (ifType of DS1) in the ifTable. Assume the entries in the ifTable for the DS2s are created in channel order and the ifIndex values are 2 through 8. In the DS1 MIB [RFC3895], there will be an entry in the dsx1ChanMappingTable for each DS2. The entries will be as follows: Nicklass Standards Track [Page 8] RFC 3896 DS3/E3 MIB September 2004 dsx1ChanMappingTable Entries ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex 1 1 2 1 2 3 ...... 1 7 8 In addition, the DS2s are channelized into DS1s. The object dsx1Channelization is set to enabledDS1 for each DS2. There will be 4 DS1s in the ifTable for each DS2. Assume the entries in the ifTable are created in channel order and the ifIndex values for the DS1s in the first DS2 are 9 through 12, then 13 through 16 for the second DS2, and so on. In the DS1 MIB, there will be an entry in the dsx1ChanMappingTable for each DS1. The entries will be as follows: dsx1ChanMappingTable Entries ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex 2 1 9 2 2 10 2 3 11 2 4 12 3 1 13 3 2 14 ... 8 4 36 2.2.4. Usage of Loopbacks This section discusses the behaviour of objects related to loopbacks. The object dsx3LoopbackConfig represents the desired state of loopbacks on this interface. Using this object a Manager can request: LineLoopback PayloadLoopback (if ESF framing) InwardLoopback DualLoopback (Line + Inward) NoLoopback The remote end can also request lookbacks either through the FDL channel if ESF or inband if D4. The loopbacks that can be requested this way are: LineLoopback PayloadLoopback (if ESF framing) NoLoopback Nicklass Standards Track [Page 9] RFC 3896 DS3/E3 MIB September 2004 To model the current state of loopbacks on a DS3 interface, the object dsx3LoopbackStatus defines which loopback is currently applied to an interface. This object, which is a bitmap, will have bits turned on which reflect the currently active loopbacks on the interface as well as the source of those loopbacks. The following restrictions/rules apply to loopbacks: The far end cannot undo loopbacks set by a manager. A manager can undo loopbacks set by the far end. Both a line loopback and an inward loopback can be set at the same time. Only these two loopbacks can co-exist and either one may be set by the manager or the far end. A LineLoopback request from the far end is incremental to an existing Inward loopback established by a manager. When a NoLoopback is received from the far end in this case, the InwardLoopback remains in place. 2.3. Objectives of this MIB Module There are numerous things that could be included in a MIB for DS3/E3 signals: the management of multiplexors, CSUs, DSUs, and the like. The intent of this document is to facilitate the common management of all devices with DS3/E3 interfaces. As such, a design decision was made up front to very closely align the MIB with the set of objects that can generally be read from DS3/E3 devices that are currently deployed. 2.4. DS3/E3 Terminology The terminology used in this document to describe error conditions on a DS3 interface as monitored by a DS3 device are based on the late but not final draft of what became the ANSI T1.231 standard [ANSI- T1.231]. If the definition in this document does not match the definition in the ANSI T1.231 document, the implementer should follow the definition described in this document. 2.4.1. Error Events Bipolar Violation (BPV) Error Event A bipolar violation error event, for B3ZS(HDB3)-coded signals, is the occurrence of a pulse of the same polarity as the previous pulse without being part of the zero substitution code, B3ZS(HDB3). For B3ZS(HDB3)-coded signals, a bipolar violation error event may also include other error patterns such as: three(four) or more consecutive zeros and incorrect polarity (See T1.231 section 7.1.1.1.1). Nicklass Standards Track [Page 10] RFC 3896 DS3/E3 MIB September 2004 Excessive Zeros (EXZ) Error Event An EXZ is the occurrence of any zero string length equal to or greater than 3 for B3ZS, or greater than 4 for HDB3 (See T1.231 section 7.1.1.1.2). Line Coding Violation (LCV) Error Event This parameter is a count of both BPVs and EXZs occurring over the accumulation period. An EXZ increments the LCV by one regardless of the length of the zero string. (Also known as CV-L. See T1.231 section 7.4.1.1.) P-bit Coding Violation (PCV) Error Event For all DS3 applications, a coding violation error event is a P-bit Parity Error event. A P-bit Parity Error event is the occurrence of a received P-bit code on the DS3 M-frame that is not identical to the corresponding locally-calculated code (See T1.231 section 7.1.1.2.1). C-bit Coding Violation (CCV) Error Event For C-bit Parity and SYNTRAN DS3 applications, this is the count of coding violations reported via the C-bits. For C-bit Parity, it is a count of CP-bit parity errors occurring in the accumulation interval. For SYNTRAN, it is a count of CRC-9 errors occurring in the accumulation interval (See T1.231 section 7.1.1.2.2). 2.4.2. Performance Parameters All performance parameters are accumulated in fifteen minute intervals and up to 96 intervals (24 hours worth) are kept by an agent. Fewer than 96 intervals of data will be available if the agent has been restarted within the last 24 hours. In addition, there is a rolling 24-hour total of each performance parameter. There is no requirement for an agent to ensure fixed relationship between the start of a fifteen minute interval and any wall clock; however some agents may align the fifteen minute intervals with quarter hours. Performance parameters are of types PerfCurrentCount, PerfIntervalCount and PerfTotalCount. These textual conventions are all Gauge32, and they are used because it is possible for these objects to decrease. Objects may decrease when Unavailable Seconds occurs across a fifteen minutes interval boundary. See Unavailable Seconds discussion later in this section. Nicklass Standards Track [Page 11] RFC 3896 DS3/E3 MIB September 2004 Line Errored Seconds (LES) A Line Errored Second is a second in which one or more CV occurred OR one or more LOS defects. (Also known as ES-L. See T1.231 section 7.4.1.2.) P-bit Errored Seconds (PES) An PES is a second with one or more PCVs OR one or more Out of Frame defects OR a detected incoming AIS. This gauge is not incremented when UASs are counted. (Also known as ESP-P. See T1.231 section 7.4.2.2.) P-bit Severely Errored Seconds (PSES) A PSES is a second with 44 or more PCVs OR one or more Out of Frame defects OR a detected incoming AIS. This gauge is not incremented when UASs are counted. (Also known as SESP-P. See T1.231 section 7.4.2.5.) C-bit Errored Seconds (CES) An CES is a second with one or more CCVs OR one or more Out of Frame defects OR a detected incoming AIS. This count is only for the SYNTRAN and C-bit Parity DS3 applications. This gauge is not incremented when UASs are counted. (Also known as ESCP-P. See T1.231 section 7.4.2.2.) C-bit Severely Errored Seconds (CSES) A CSES is a second with 44 or more CCVs OR one or more Out of Frame defects OR a detected incoming AIS. This count is only for the SYNTRAN and C-bit Parity DS3 applications. This gauge is not incremented when UASs are counted. (Also known as SESCP-P. See T1.231 section 7.4.2.5.) Severely Errored Framing Seconds (SEFS) A SEFS is a second with one or more Out of Frame defects OR a detected incoming AIS. This item is not incremented during unavailable seconds. (Also known as SAS-P. See T1.231 section 7.4.2.6.) Unavailable Seconds (UAS) UAS are calculated by counting the number of seconds that the interface is unavailable. The DS3 interface is said to be unavailable from the onset of 10 contiguous PSESs, or the onset of the condition leading to a failure (see Failure States). If the condition leading to the failure was immediately preceded by one or more contiguous PSESs, then the DS3 interface unavailability starts from the onset of these PSESs. Once unavailable, and if no failure is present, the DS3 interface becomes available at the onset of 10 contiguous seconds with no PSESs. Once unavailable, and if a Nicklass Standards Track [Page 12] RFC 3896 DS3/E3 MIB September 2004 failure is present, the DS3 interface becomes available at the onset of 10 contiguous seconds with no PSESs, if the failure clearing time is less than or equal to 10 seconds. If the failure clearing time is more than 10 seconds, the DS3 interface becomes available at the onset of 10 contiguous seconds with no PSESs, or the onset period leading to the successful clearing condition, whichever occurs later. With respect to the DS3 error counts, all counters are incremented while the DS3 interface is deemed available. While the interface is deemed unavailable, the only count that is incremented is UASs. Note that this definition implies that the agent cannot determine until after a ten second interval has passed whether a given one-second interval belongs to available or unavailable time. If the agent chooses to update the various performance statistics in real time then it must be prepared to retroactively reduce the PES, PSES, CES, and CSES counts by 10 and increase the UAS count by 10 when it determines that available time has been entered. It must also be prepared to adjust the PCV, CCV, and SEFS count as necessary since these parameters are not accumulated during unavailable time. Similarly, it must be prepared to retroactively decrease the UAS count by 10 and increase the PES, CES, PCV, and CCV counts as necessary upon entering available time. A special case exists when the 10 second period leading to available or unavailable time crosses a 900 second statistics window boundary, as the foregoing description implies that the PCV, CCV, PES, CES, PSES, CSEC, SEFS, and UAS counts for the PREVIOUS interval must be adjusted. In this case successive GETs of the affected dsx3IntervalPSESs and dsx3IntervalUASs objects will return differing values if the first GET occurs during the first few seconds of the window. The agent may instead choose to delay updates to the various statistics by 10 seconds in order to avoid retroactive adjustments to the counters. A way to do this is sketched in Appendix B. In any case, a linkDown trap shall be sent only after the agent has determined for certain that the unavailable state has been entered, but the time on the trap will be that of the first UAS (i.e., 10 seconds earlier). A linkUp trap shall be handled similarly. According to [ANSI-T1.231] unavailable time begins at the _onset_ of 10 contiguous severely errored seconds -- that is, unavailable time starts with the _first_ of the 10 contiguous SESs. Also, while an interface is deemed unavailable all counters for that interface are Nicklass Standards Track [Page 13] RFC 3896 DS3/E3 MIB September 2004 frozen except for the UAS count. It follows that an implementation which strictly complies with this standard must _not_ increment any counters other than the UAS count -- even temporarily -- as a result of anything that happens during those 10 seconds. Since changes in the signal state lag the data to which they apply by 10 seconds, an ANSI-compliant implementation must pass the one-second statistics through a 10-second delay line prior to updating any counters. That can be done by performing the following steps at the end of each one second interval. i) Read near/far end CV counter and alarm status flags from the hardware. ii) Accumulate the CV counts for the preceding second and compare them to the ES and SES threshold for the layer in question. Update the signal state and shift the one-second CV counts and ES/SES flags into the 10-element delay line. Note that far-end one-second statistics are to be flagged as "absent" during any second in which there is an incoming defect at the layer in question or at any lower layer. iii) Update the current interval statistics using the signal state from the _previous_ update cycle and the one-second CV counts and ES/SES flags shifted out of the 10-element delay line. This approach is further described in Appendix B. 2.4.3. Performance Defects Failure States: The Remote Alarm Indication (RAI) failure, in SYNTRAN applications, is declared after detecting the Yellow Alarm Signal on the alarm channel. See ANSI T1.107a-1990 [ANSI- T1.107a]. The Remote Alarm Indication failure, in C-bit Parity DS3 applications, is declared as soon as the presence of either one or two alarm signals are detected on the Far End Alarm Channel. See [ANSI-T1.107]. The Remote Alarm Indication failure may also be declared after detecting the far-end SEF/AIS defect (aka yellow). The Remote Alarm Indication failure is cleared as soon as the presence of the any of the above alarms are removed. Also, the incoming failure state is declared when a defect persists for at least 2-10 seconds. The defects are the following: Loss of Signal (LOS), an Out of Frame (OOF) or an incoming Alarm Indication Signal (AIS). The Failure State is cleared when the defect is absent for less than or equal to 20 seconds. Nicklass Standards Track [Page 14] RFC 3896 DS3/E3 MIB September 2004 Far End SEF/AIS defect (aka yellow) A Far End SEF/AIS defect is the occurrence of the two X-bits in a M-frame set to zero. The Far End SEF/AIS defect is terminated when the two X-bits in a M-frame are set to one. (Also known as SASCP-PFE. See T1.231 section 7.4.4.2.6) Out of Frame (OOF) defect A DS3 OOF defect is detected when any three or more errors in sixteen or fewer consecutive F-bits occur within a DS3 M- frame. An OOF defect may also be called a Severely Errored Frame (SEF) defect. An OOF defect is cleared when reframe occurs. A DS3 Loss of Frame (LOF) failure is declared when the DS3 OOF defect is consistent for 2 to 10 seconds. The DS3 OOF defect ends when reframe occurs. The DS3 LOF failure is cleared when the DS3 OOF defect is absent for 10 to 20 seconds. (See T1.231 section 7.1.2.2.1) An E3 OOF defect is detected when four consecutive frame alignment signals have been incorrectly received in there predicted positions in an E3 signal. E3 frame alignment occurs when the presence of three consecutive frame alignment signals have been detected. Loss of Signal (LOS) defect The DS3 LOS defect is declared upon observing 175 +/- 75 contiguous pulse positions with no pulses of either positive or negative polarity. The DS3 LOS defect is terminated upon observing an average pulse density of at least 33% over a period of 175 +/- 75 contiguous pulse positions starting with the receipt of a pulse. (See T1.231 section 7.1.2.1.1) Alarm Indication Signal (AIS) defect The DS3 AIS is framed with "stuck stuffing." This implies that it has a valid M-subframe alignments bits, M-frame alignment bits, and P bits. The information bits are set to a 1010... sequence, starting with a one (1) after each M- subframe alignment bit, M-frame alignment bit, X bit, P bit, and C bit. The C bits are all set to zero giving what is called "stuck stuffing." The X bits are set to one. The DS3 AIS defect is declared after DS3 AIS is present in contiguous M-frames for a time equal to or greater than T, where 0.2 ms <= T <= 100 ms. The DS3 AIS defect is terminated after AIS is absent in contiguous M-frames for a time equal to or greater than T. (See T1.231 section 7.1.2.2.3) Nicklass Standards Track [Page 15] RFC 3896 DS3/E3 MIB September 2004 The E3 binary content of the AIS is nominally a continuous stream of ones. AIS detection and the application of consequent actions, should be completed within a time limit of 1 ms. 2.4.4. Other Terms Circuit Identifier This is a character string specified by the circuit vendor, and is useful when communicating with the vendor during the troubleshooting process (see M.1400 [ITU-T-M.1400] for additional information). Proxy In this document, the word proxy is meant to indicate an application which receives SNMP messages and replies to them on behalf of the devices which implement the actual DS3/E3 interfaces. The proxy may have already collected the information about the DS3/E3 interfaces into its local database and may not necessarily forward the requests to the actual DS3/E3 interface. It is expected in such an application that there are periods of time where the proxy is not communicating with the DS3/E3 interfaces. In these instances the proxy will not necessarily have up-to-date configuration information and will most likely have missed the collection of some statistics data. Missed statistics data collection will result in invalid data in the interval table. 3. Object Definitions DS3-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, transmission FROM SNMPv2-SMI -- [RFC2578] DisplayString, TimeStamp, TruthValue FROM SNMPv2-TC -- [RFC2579] MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580] InterfaceIndex FROM IF-MIB -- [RFC2863] PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB; -- [RFC3593] Nicklass Standards Track [Page 16] RFC 3896 DS3/E3 MIB September 2004 ds3 MODULE-IDENTITY LAST-UPDATED "200409080000Z" -- September 08, 2004 ORGANIZATION "IETF AToM MIB Working Group" CONTACT-INFO "WG charter: http://www.ietf.org/html.charters/atommib-charter.html Mailing Lists: General Discussion: atommib@research.telcordia.com To Subscribe: atommib-request@research.telcordia.com Editor: Orly Nicklass Postal: RAD Data Communications, Ltd. Ziv Tower, 24 Roul Walenberg Tel Aviv, Israel, 69719 Tel: +9723 765 9969 E-mail: orly_n@rad.com" DESCRIPTION "The is the MIB module that describes DS3 and E3 interfaces objects. Copyright (c) The Internet Society (2004). This version of this MIB module is part of RFC 3896; see the RFC itself for full legal notices." REVISION "200409080000Z" -- September 08, 2004 DESCRIPTION "The RFC 3896 version of this MIB module. The key changes made to this MIB module since its publication in RFC 2496 are as follows: (1) The dsx3FracIfIndex SYNTAX matches the description range. (2) Reference was added to Circuit Identifier object. (3) Usage of ifStackTable section was updated. (4) Align the DESCRIPTION clauses of few statistic objects with thenear end definition, the far end definition and with RFC 3593. (5) Add new value, dsx3M13, to dsx3LineType." REVISION "199808012130Z" Nicklass Standards Track [Page 17] RFC 3896 DS3/E3 MIB September 2004 DESCRIPTION "The RFC 2496 version of this MIB module. The key changes made to this MIB module since its publication in RFC 1407 are as follows: (1) The Fractional Table has been deprecated. (2) This document uses SMIv2. (3) Values are given for ifTable and ifXTable. (4) Example usage of ifStackTable is included. (5) dsx3IfIndex has been deprecated. (6) The definition of valid intervals has been clarified for the case where the agent proxied for other devices. In particular, the treatment of missing intervals has been clarified. (7) An inward loopback has been added. (8) Additional lineStatus bits have been added for Near End in Unavailable Signal State, Carrier Equipment Out of Service. (9) A read-write line Length object has been added. (10) Added a lineStatus last change, trap and enabler. (11) Textual Conventions for statistics objects have been used. (12) A new object, dsx3LoopbackStatus, has been introduced to reflect the loopbacks established on a DS3/E3 interface and the source to the requests. dsx3LoopbackConfig continues to be the desired loopback state while dsx3LoopbackStatus reflects the actual state. (13) A dual loopback has been added to allow the setting of an inward loopback and a line loopback at the same time. (14) An object has been added to indicated whether or not this is a channelized DS3/E3. (15) A new object has been added to indicate which DS1 is to set for remote loopback." Nicklass Standards Track [Page 18] RFC 3896 DS3/E3 MIB September 2004 REVISION "199301252028Z" DESCRIPTION "Initial version, published as RFC 1407." ::= { transmission 30 } -- The DS3/E3 Near End Group -- The DS3/E3 Near End Group consists of four tables: -- DS3/E3 Configuration -- DS3/E3 Current -- DS3/E3 Interval -- DS3/E3 Total -- the DS3/E3 Configuration Table dsx3ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 Configuration table." ::= { ds3 5 } dsx3ConfigEntry OBJECT-TYPE SYNTAX Dsx3ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3/E3 Configuration table." INDEX { dsx3LineIndex } ::= { dsx3ConfigTable 1 } Dsx3ConfigEntry ::= SEQUENCE { dsx3LineIndex InterfaceIndex, dsx3IfIndex InterfaceIndex, dsx3TimeElapsed INTEGER, dsx3ValidIntervals INTEGER, dsx3LineType INTEGER, dsx3LineCoding INTEGER, dsx3SendCode INTEGER, dsx3CircuitIdentifier DisplayString, dsx3LoopbackConfig INTEGER, dsx3LineStatus INTEGER, dsx3TransmitClockSource INTEGER, dsx3InvalidIntervals INTEGER, dsx3LineLength INTEGER, dsx3LineStatusLastChange TimeStamp, Nicklass Standards Track [Page 19] RFC 3896 DS3/E3 MIB September 2004 dsx3LineStatusChangeTrapEnable INTEGER, dsx3LoopbackStatus INTEGER, dsx3Channelization INTEGER, dsx3Ds1ForRemoteLoop INTEGER } dsx3LineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows proper use of ifStackTable. Previously, this object was the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers." ::= { dsx3ConfigEntry 1 } dsx3IfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (RFC 1213)." ::= { dsx3ConfigEntry 2 } dsx3TimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the Nicklass Standards Track [Page 20] RFC 3896 DS3/E3 MIB September 2004 beginning of the near end current error- measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { dsx3ConfigEntry 3 } dsx3ValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { dsx3ConfigEntry 4 } dsx3LineType OBJECT-TYPE SYNTAX INTEGER { dsx3other(1), dsx3M23(2), dsx3SYNTRAN(3), dsx3CbitParity(4), dsx3ClearChannel(5), e3other(6), e3Framed(7), e3Plcp(8), dsx3M13(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe: Nicklass Standards Track [Page 21] RFC 3896 DS3/E3 MIB September 2004 TITLE: SPECIFICATION: dsx3M23 ANSI T1.107-1988 dsx3SYNTRAN ANSI T1.107-1988 dsx3CbitParity ANSI T1.107a-1990 dsx3ClearChannel ANSI T1.102-1987 e3Framed CCITT G.751 e3Plcp ETSI T/NA(91)18 dsx3M13 ANSI T1.107a-1990." REFERENCE "American National Standard for telecommunications - digital hierarchy - formats specification, ANSI T1.107- 1988. ANSI T1.107a-1990. American National Standard for telecommunications - digital hierarchy - electrical interfaces, ANSI T1.102- 1987. CCITT - Digital Multiplex Equipment Operating at the Third Order Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264 Kbit/s and Using Positive Justification, G.751 European Telecommunications Standards Institute -- ETS '34M' -- Metropolitan Area Network Physical Convergence Layer Procedure for 34.368 Megabits per Second, T/NA(91)18, May 1991." ::= { dsx3ConfigEntry 5 } dsx3LineCoding OBJECT-TYPE SYNTAX INTEGER { dsx3Other(1), dsx3B3ZS(2), e3HDB3(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. dsx3B3ZS and e3HDB3 refer to the use of specified patterns of normal bits and bipolar violations which are used to replace sequences of zero bits of a specified length." ::= { dsx3ConfigEntry 6 } dsx3SendCode OBJECT-TYPE Nicklass Standards Track [Page 22] RFC 3896 DS3/E3 MIB September 2004 SYNTAX INTEGER { dsx3SendNoCode(1), dsx3SendLineCode(2), dsx3SendPayloadCode(3), dsx3SendResetCode(4), dsx3SendDS1LoopCode(5), dsx3SendTestPattern(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates what type of code is being sent across the DS3/E3 interface by the device. (These are optional for E3 interfaces.) Setting this variable causes the interface to begin sending the code requested. The values mean: dsx3SendNoCode sending looped or normal data dsx3SendLineCode sending a request for a line loopback dsx3SendPayloadCode sending a request for a payload loopback (i.e., all DS1/E1s in a DS3/E3 frame) dsx3SendResetCode sending a loopback deactivation request dsx3SendDS1LoopCode requesting to loopback a particular DS1/E1 within a DS3/E3 frame. The DS1/E1 is indicated in dsx3Ds1ForRemoteLoop. dsx3SendTestPattern sending a test pattern." ::= { dsx3ConfigEntry 7 } dsx3CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting." Nicklass Standards Track [Page 23] RFC 3896 DS3/E3 MIB September 2004 REFERENCE "ITU-T M.1400" ::= { dsx3ConfigEntry 8 } dsx3LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { dsx3NoLoop(1), dsx3PayloadLoop(2), dsx3LineLoop(3), dsx3OtherLoop(4), dsx3InwardLoop(5), dsx3DualLoop(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable represents the desired loopback configuration of the DS3/E3 interface. The values mean: dsx3NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value. dsx3PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. dsx3LineLoop The received signal at this interface does not go through the device (minimum penetration) but is looped back out. dsx3OtherLoop Loopbacks that are not defined here. dsx3InwardLoop The sent signal at this interface is looped back through the device. dsx3DualLoop Both dsx1LineLoop and dsx1InwardLoop will be active simultaneously." ::= { dsx3ConfigEntry 9 } Nicklass Standards Track [Page 24] RFC 3896 DS3/E3 MIB September 2004 dsx3LineStatus OBJECT-TYPE SYNTAX INTEGER (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures and a loopback (see dsx3LoopbackConfig object for the type of loopback) simultaneously. The dsx3NoAlarm must be set if and only if no other flag is set. If the dsx3loopbackState bit is set, the loopback in effect can be determined from the dsx3loopbackConfig object. The various bit positions are: 1 dsx3NoAlarm No alarm present 2 dsx3RcvRAIFailure Receiving Yellow/Remote Alarm Indication 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote Alarm Indication 8 dsx3RcvAIS Receiving AIS failure state 16 dsx3XmitAIS Transmitting AIS 32 dsx3LOF Receiving LOF failure state 64 dsx3LOS Receiving LOS failure state 128 dsx3LoopbackState Looping the received signal 256 dsx3RcvTestCode Receiving a Test Pattern 512 dsx3OtherFailure any line status not defined here 1024 dsx3UnavailSigState Near End in Unavailable Signal State 2048 dsx3NetEquipOOS Carrier Equipment Out of Service" ::= { dsx3ConfigEntry 10 } dsx3TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of Transmit Clock. Nicklass Standards Track [Page 25] RFC 3896 DS3/E3 MIB September 2004 loopTiming indicates that the recovered receive clock is used as the transmit clock. localTiming indicates that a local clock source is used or that an external clock is attached to the box containing the interface. throughTiming indicates that transmit clock is derived from the recovered receive clock of another DS3 interface." ::= { dsx3ConfigEntry 11 } dsx3InvalidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION " The number of intervals in the range from 0 to dsx3ValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations)." ::= { dsx3ConfigEntry 12 } dsx3LineLength OBJECT-TYPE SYNTAX INTEGER (0..64000) UNITS "meters" MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out." ::= { dsx3ConfigEntry 13 } dsx3LineStatusLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value." ::= { dsx3ConfigEntry 14 } Nicklass Standards Track [Page 26] RFC 3896 DS3/E3 MIB September 2004 dsx3LineStatusChangeTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether dsx3LineStatusChange traps should be generated for this interface." DEFVAL { disabled } ::= { dsx3ConfigEntry 15 } dsx3LoopbackStatus OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the current state of the loopback on the DS3 interface. It contains information about loopbacks established by a manager and remotely from the far end. The dsx3LoopbackStatus is a bit map represented as a sum, therefore is can represent multiple loopbacks simultaneously. The various bit positions are: 1 dsx3NoLoopback 2 dsx3NearEndPayloadLoopback 4 dsx3NearEndLineLoopback 8 dsx3NearEndOtherLoopback 16 dsx3NearEndInwardLoopback 32 dsx3FarEndPayloadLoopback 64 dsx3FarEndLineLoopback" ::= { dsx3ConfigEntry 16 } dsx3Channelization OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledDs1(2), enabledDs2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether this ds3/e3 is channelized or unchannelized. The value of enabledDs1 indicates Nicklass Standards Track [Page 27] RFC 3896 DS3/E3 MIB September 2004 that this is a DS3 channelized into DS1s. The value of enabledDs3 indicated that this is a DS3 channelized into DS2s. Setting this object will cause the creation or deletion of DS2 or DS1 entries in the ifTable. " ::= { dsx3ConfigEntry 17 } dsx3Ds1ForRemoteLoop OBJECT-TYPE SYNTAX INTEGER (0..29) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates which DS1/E1 on this DS3/E3 will be indicated in the remote ds1 loopback request. A value of 0 means no DS1 will be looped. A value of 29 means all DS1s/E1s will be looped." ::= { dsx3ConfigEntry 18 } -- the DS3/E3 Current Table dsx3CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 current table contains various statistics being collected for the current 15 minute interval." ::= { ds3 6 } dsx3CurrentEntry OBJECT-TYPE SYNTAX Dsx3CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3/E3 Current table." INDEX { dsx3CurrentIndex } ::= { dsx3CurrentTable 1 } Dsx3CurrentEntry ::= SEQUENCE { dsx3CurrentIndex InterfaceIndex, dsx3CurrentPESs PerfCurrentCount, dsx3CurrentPSESs PerfCurrentCount, dsx3CurrentSEFSs PerfCurrentCount, dsx3CurrentUASs PerfCurrentCount, dsx3CurrentLCVs PerfCurrentCount, Nicklass Standards Track [Page 28] RFC 3896 DS3/E3 MIB September 2004 dsx3CurrentPCVs PerfCurrentCount, dsx3CurrentLESs PerfCurrentCount, dsx3CurrentCCVs PerfCurrentCount, dsx3CurrentCESs PerfCurrentCount, dsx3CurrentCSESs PerfCurrentCount } dsx3CurrentIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3CurrentEntry 1 } dsx3CurrentPESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Errored Seconds." ::= { dsx3CurrentEntry 2 } dsx3CurrentPSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds." ::= { dsx3CurrentEntry 3 } dsx3CurrentSEFSs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds." ::= { dsx3CurrentEntry 4 } Nicklass Standards Track [Page 29] RFC 3896 DS3/E3 MIB September 2004 dsx3CurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds." ::= { dsx3CurrentEntry 5 } dsx3CurrentLCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line Coding Violations." ::= { dsx3CurrentEntry 6 } dsx3CurrentPCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Coding Violations." ::= { dsx3CurrentEntry 7 } dsx3CurrentLESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds." ::= { dsx3CurrentEntry 8 } dsx3CurrentCCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Coding Violations." ::= { dsx3CurrentEntry 9 } dsx3CurrentCESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION Nicklass Standards Track [Page 30] RFC 3896 DS3/E3 MIB September 2004 "The number of C-bit Errored Seconds." ::= { dsx3CurrentEntry 10 } dsx3CurrentCSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Severely Errored Seconds." ::= { dsx3CurrentEntry 11 } -- the DS3/E3 Interval Table dsx3IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 Interval Table contains various statistics collected by each DS3/E3 Interface over the previous 24 hours of operation. The past 24 hours are broken into 96 completed 15 minute intervals. Each row in this table represents one such interval (identified by dsx3IntervalNumber) and for one specific interface (identified by dsx3IntervalIndex)." ::= { ds3 7 } dsx3IntervalEntry OBJECT-TYPE SYNTAX Dsx3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3/E3 Interval table." INDEX { dsx3IntervalIndex, dsx3IntervalNumber } ::= { dsx3IntervalTable 1 } Dsx3IntervalEntry ::= SEQUENCE { dsx3IntervalIndex InterfaceIndex, dsx3IntervalNumber INTEGER, dsx3IntervalPESs PerfIntervalCount, dsx3IntervalPSESs PerfIntervalCount, dsx3IntervalSEFSs PerfIntervalCount, dsx3IntervalUASs PerfIntervalCount, dsx3IntervalLCVs PerfIntervalCount, dsx3IntervalPCVs PerfIntervalCount, dsx3IntervalLESs PerfIntervalCount, Nicklass Standards Track [Page 31] RFC 3896 DS3/E3 MIB September 2004 dsx3IntervalCCVs PerfIntervalCount, dsx3IntervalCESs PerfIntervalCount, dsx3IntervalCSESs PerfIntervalCount, dsx3IntervalValidData TruthValue } dsx3IntervalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3IntervalEntry 1 } dsx3IntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minutes interval completed 23 hours and 45 minutes prior to interval 1." ::= { dsx3IntervalEntry 2 } dsx3IntervalPESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Errored Seconds." ::= { dsx3IntervalEntry 3 } dsx3IntervalPSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds." Nicklass Standards Track [Page 32] RFC 3896 DS3/E3 MIB September 2004 ::= { dsx3IntervalEntry 4 } dsx3IntervalSEFSs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds." ::= { dsx3IntervalEntry 5 } dsx3IntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds. This object may decrease if the occurrence of unavailable seconds occurs across an interval boundary." ::= { dsx3IntervalEntry 6 } dsx3IntervalLCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line Coding Violations." ::= { dsx3IntervalEntry 7 } dsx3IntervalPCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Coding Violations." ::= { dsx3IntervalEntry 8 } dsx3IntervalLESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds (BPVs or illegal zero sequences)." ::= { dsx3IntervalEntry 9 } Nicklass Standards Track [Page 33] RFC 3896 DS3/E3 MIB September 2004 dsx3IntervalCCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Coding Violations." ::= { dsx3IntervalEntry 10 } dsx3IntervalCESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Errored Seconds." ::= { dsx3IntervalEntry 11 } dsx3IntervalCSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Severely Errored Seconds." ::= { dsx3IntervalEntry 12 } dsx3IntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " This variable indicates if the data for this interval is valid." ::= { dsx3IntervalEntry 13 } -- the DS3/E3 Total dsx3TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3/E3 Total Table contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval." ::= { ds3 8 } dsx3TotalEntry OBJECT-TYPE SYNTAX Dsx3TotalEntry MAX-ACCESS not-accessible Nicklass Standards Track [Page 34] RFC 3896 DS3/E3 MIB September 2004 STATUS current DESCRIPTION "An entry in the DS3/E3 Total table." INDEX { dsx3TotalIndex } ::= { dsx3TotalTable 1 } Dsx3TotalEntry ::= SEQUENCE { dsx3TotalIndex InterfaceIndex, dsx3TotalPESs PerfTotalCount, dsx3TotalPSESs PerfTotalCount, dsx3TotalSEFSs PerfTotalCount, dsx3TotalUASs PerfTotalCount, dsx3TotalLCVs PerfTotalCount, dsx3TotalPCVs PerfTotalCount, dsx3TotalLESs PerfTotalCount, dsx3TotalCCVs PerfTotalCount, dsx3TotalCESs PerfTotalCount, dsx3TotalCSESs PerfTotalCount } dsx3TotalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3TotalEntry 1 } dsx3TotalPESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 2 } dsx3TotalPSESs OBJECT-TYPE SYNTAX PerfTotalCount Nicklass Standards Track [Page 35] RFC 3896 DS3/E3 MIB September 2004 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 3 } dsx3TotalSEFSs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds, encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 4 } dsx3TotalUASs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 5 } dsx3TotalLCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Line Coding Violations encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 6 } dsx3TotalPCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of P-bit Nicklass Standards Track [Page 36] RFC 3896 DS3/E3 MIB September 2004 Coding Violations, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 7 } dsx3TotalLESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds (BPVs or illegal zero sequences) encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 8 } dsx3TotalCCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Coding Violations encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 9 } dsx3TotalCESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 10 } dsx3TotalCSESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3TotalEntry 11 } Nicklass Standards Track [Page 37] RFC 3896 DS3/E3 MIB September 2004 -- The DS3 Far End Group -- The DS3 Far End Group consists of four tables : -- DS3 Far End Configuration -- DS3 Far End Current -- DS3 Far End Interval -- DS3 Far End Total -- The DS3 Far End Configuration Table dsx3FarEndConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Far End Configuration Table contains configuration information reported in the C-bits from the remote end." ::= { ds3 9 } dsx3FarEndConfigEntry OBJECT-TYPE SYNTAX Dsx3FarEndConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Far End Configuration table." INDEX { dsx3FarEndLineIndex } ::= { dsx3FarEndConfigTable 1 } Dsx3FarEndConfigEntry ::= SEQUENCE { dsx3FarEndLineIndex InterfaceIndex, dsx3FarEndEquipCode DisplayString, dsx3FarEndLocationIDCode DisplayString, dsx3FarEndFrameIDCode DisplayString, dsx3FarEndUnitCode DisplayString, dsx3FarEndFacilityIDCode DisplayString } dsx3FarEndLineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this Nicklass Standards Track [Page 38] RFC 3896 DS3/E3 MIB September 2004 index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndConfigEntry 1 } dsx3FarEndEquipCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 2 } dsx3FarEndLocationIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 3 } dsx3FarEndFrameIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End Frame Identification code that identifies where the equipment is located within a building at a given location. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 4 } dsx3FarEndUnitCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 5 } dsx3FarEndFacilityIDCode OBJECT-TYPE Nicklass Standards Track [Page 39] RFC 3896 DS3/E3 MIB September 2004 SYNTAX DisplayString (SIZE (0..38)) MAX-ACCESS read-write STATUS current DESCRIPTION "This code identifies a specific Far End DS3 path. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 6 } -- The DS3 Far End Current dsx3FarEndCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Far End Current table contains various statistics being collected for the current 15 minute interval. The statistics are collected from the far end block error code within the C- bits." ::= { ds3 10 } dsx3FarEndCurrentEntry OBJECT-TYPE SYNTAX Dsx3FarEndCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Far End Current table." INDEX { dsx3FarEndCurrentIndex } ::= { dsx3FarEndCurrentTable 1 } Dsx3FarEndCurrentEntry ::= SEQUENCE { dsx3FarEndCurrentIndex InterfaceIndex, dsx3FarEndTimeElapsed INTEGER, dsx3FarEndValidIntervals INTEGER, dsx3FarEndCurrentCESs PerfCurrentCount, dsx3FarEndCurrentCSESs PerfCurrentCount, dsx3FarEndCurrentCCVs PerfCurrentCount, dsx3FarEndCurrentUASs PerfCurrentCount, dsx3FarEndInvalidIntervals INTEGER } dsx3FarEndCurrentIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index Nicklass Standards Track [Page 40] RFC 3896 DS3/E3 MIB September 2004 STATUS current DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx3LineIndex." ::= { dsx3FarEndCurrentEntry 1 } dsx3FarEndTimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the far end current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { dsx3FarEndCurrentEntry 2 } dsx3FarEndValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous far end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute far end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { dsx3FarEndCurrentEntry 3 } dsx3FarEndCurrentCESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds." ::= { dsx3FarEndCurrentEntry 4 } Nicklass Standards Track [Page 41] RFC 3896 DS3/E3 MIB September 2004 dsx3FarEndCurrentCSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds." ::= { dsx3FarEndCurrentEntry 5 } dsx3FarEndCurrentCCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count." ::= { dsx3FarEndCurrentEntry 6 } dsx3FarEndCurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End unavailable seconds." ::= { dsx3FarEndCurrentEntry 7 } dsx3FarEndInvalidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION " The number of intervals in the range from 0 to dsx3FarEndValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations)." ::= { dsx3FarEndCurrentEntry 8 } -- The DS3 Far End Interval Table dsx3FarEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Far End Interval Table contains various Nicklass Standards Track [Page 42] RFC 3896 DS3/E3 MIB September 2004 statistics collected by each DS3 interface over the previous 24 hours of operation. The past 24 hours are broken into 96 completed 15 minute intervals." ::= { ds3 11 } dsx3FarEndIntervalEntry OBJECT-TYPE SYNTAX Dsx3FarEndIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Far End Interval table." INDEX { dsx3FarEndIntervalIndex, dsx3FarEndIntervalNumber } ::= { dsx3FarEndIntervalTable 1 } Dsx3FarEndIntervalEntry ::= SEQUENCE { dsx3FarEndIntervalIndex InterfaceIndex, dsx3FarEndIntervalNumber INTEGER, dsx3FarEndIntervalCESs PerfIntervalCount, dsx3FarEndIntervalCSESs PerfIntervalCount, dsx3FarEndIntervalCCVs PerfIntervalCount, dsx3FarEndIntervalUASs PerfIntervalCount, dsx3FarEndIntervalValidData TruthValue } dsx3FarEndIntervalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx3LineIndex." ::= { dsx3FarEndIntervalEntry 1 } dsx3FarEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is Nicklass Standards Track [Page 43] RFC 3896 DS3/E3 MIB September 2004 the 15 minutes interval completed 23 hours and 45 minutes prior to interval 1." ::= { dsx3FarEndIntervalEntry 2 } dsx3FarEndIntervalCESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. In the case where the agent is a proxy and data is not available, return noSuchInstance." ::= { dsx3FarEndIntervalEntry 3 } dsx3FarEndIntervalCSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds." ::= { dsx3FarEndIntervalEntry 4 } dsx3FarEndIntervalCCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count." ::= { dsx3FarEndIntervalEntry 5 } dsx3FarEndIntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End unavailable seconds." ::= { dsx3FarEndIntervalEntry 6 } dsx3FarEndIntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only Nicklass Standards Track [Page 44] RFC 3896 DS3/E3 MIB September 2004 STATUS current DESCRIPTION " This variable indicates if the data for this interval is valid." ::= { dsx3FarEndIntervalEntry 7 } -- The DS3 Far End Total dsx3FarEndTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Far End Total Table contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval." ::= { ds3 12 } dsx3FarEndTotalEntry OBJECT-TYPE SYNTAX Dsx3FarEndTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Far End Total table." INDEX { dsx3FarEndTotalIndex } ::= { dsx3FarEndTotalTable 1 } Dsx3FarEndTotalEntry ::= SEQUENCE { dsx3FarEndTotalIndex InterfaceIndex, dsx3FarEndTotalCESs PerfTotalCount, dsx3FarEndTotalCSESs PerfTotalCount, dsx3FarEndTotalCCVs PerfTotalCount, dsx3FarEndTotalUASs PerfTotalCount } dsx3FarEndTotalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx3LineIndex." ::= { dsx3FarEndTotalEntry 1 } Nicklass Standards Track [Page 45] RFC 3896 DS3/E3 MIB September 2004 dsx3FarEndTotalCESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3FarEndTotalEntry 2 } dsx3FarEndTotalCSESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3FarEndTotalEntry 3 } dsx3FarEndTotalCCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3FarEndTotalEntry 4 } dsx3FarEndTotalUASs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0." ::= { dsx3FarEndTotalEntry 5 } -- the DS3/E3 Fractional Table -- This table is deprecated. Nicklass Standards Track [Page 46] RFC 3896 DS3/E3 MIB September 2004 dsx3FracTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FracEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This table is deprecated in favour of using ifStackTable. Implementation of this table was optional. It was designed for those systems dividing a DS3/E3 into channels containing different data streams that are of local interest. The DS3/E3 fractional table identifies which DS3/E3 channels associated with a CSU are being used to support a logical interface, i.e., an entry in the interfaces table from the Internet- standard MIB. For example, consider a DS3 device with 4 high speed links carrying router traffic, a feed for voice, a feed for video, and a synchronous channel for a non-routed protocol. We might describe the allocation of channels, in the dsx3FracTable, as follows: dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4 dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6 dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6 dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6 dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6 dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6 dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6 dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6 dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6 dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6 dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6 dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6 dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6 dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6 For dsx3M23, dsx3 SYNTRAN, dsx3CbitParity, and dsx3ClearChannel there are 28 legal channels, numbered 1 through 28. For e3Framed there are 16 legal channels, numbered 1 through 16. The channels (1..16) correspond directly to the equivalently numbered time-slots." ::= { ds3 13 } Nicklass Standards Track [Page 47] RFC 3896 DS3/E3 MIB September 2004 dsx3FracEntry OBJECT-TYPE SYNTAX Dsx3FracEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry in the DS3 Fractional table." INDEX { dsx3FracIndex, dsx3FracNumber } ::= { dsx3FracTable 1 } Dsx3FracEntry ::= SEQUENCE { dsx3FracIndex INTEGER, dsx3FracNumber INTEGER, dsx3FracIfIndex INTEGER } dsx3FracIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS deprecated DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FracEntry 1 } dsx3FracNumber OBJECT-TYPE SYNTAX INTEGER (1..31) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS deprecated DESCRIPTION "The channel number for this entry." ::= { dsx3FracEntry 2 } dsx3FracIfIndex OBJECT-TYPE SYNTAX INTEGER (0..'7fffffff'h) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "An index value that uniquely identifies an interface. The interface identified by a particular value of this index is the same interface as identified by the same value an Nicklass Standards Track [Page 48] RFC 3896 DS3/E3 MIB September 2004 ifIndex object instance. If no interface is currently using a channel, the value should be zero. If a single interface occupies more than one time slot, that ifIndex value will be found in multiple time slots." ::= { dsx3FracEntry 3 } -- DS3 TRAPS ds3Traps OBJECT IDENTIFIER ::= { ds3 15 } dsx3LineStatusChange NOTIFICATION-TYPE OBJECTS { dsx3LineStatus, dsx3LineStatusLastChange } STATUS current DESCRIPTION "A dsx3LineStatusChange trap is sent when the value of an instance of dsx3LineStatus changes. It can be utilized by an NMS to trigger polls. When the line status change results in a lower level line status change (i.e., ds1), then no traps for the lower level are sent." ::= { ds3Traps 0 1 } -- conformance information ds3Conformance OBJECT IDENTIFIER ::= { ds3 14 } ds3Groups OBJECT IDENTIFIER ::= { ds3Conformance 1 } ds3Compliances OBJECT IDENTIFIER ::= { ds3Conformance 2 } -- compliance statements ds3Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for DS3/E3 interfaces." MODULE -- this module MANDATORY-GROUPS { ds3NearEndConfigGroup, ds3NearEndStatisticsGroup } GROUP ds3FarEndGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS3 Interface. However, only C-bit Parity and SYNTRAN DS3 applications have the capability (option) of providing this information." GROUP ds3NearEndOptionalTrapGroup Nicklass Standards Track [Page 49] RFC 3896 DS3/E3 MIB September 2004 DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS3 Interface. If it is implemented then ds3NearEndOptionalConfigGroup should also be implemented." GROUP ds3NearEndOptionalConfigGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS3 interface." OBJECT dsx3LineType MIN-ACCESS read-only DESCRIPTION "Write access for the line type is not required." OBJECT dsx3LineCoding MIN-ACCESS read-only DESCRIPTION "Write access for the line coding is not required." OBJECT dsx3SendCode MIN-ACCESS read-only DESCRIPTION "Write access for the send code is not required." OBJECT dsx3LoopbackConfig MIN-ACCESS read-only DESCRIPTION "Write access for loopbacks is not required." OBJECT dsx3TransmitClockSource MIN-ACCESS read-only DESCRIPTION "Write access for the transmit clock source is not required." OBJECT dsx3LineLength MIN-ACCESS read-only DESCRIPTION "Write access for the line length is not required." OBJECT dsx3Channelization MIN-ACCESS read-only DESCRIPTION "Write access for the channelization is not required." Nicklass Standards Track [Page 50] RFC 3896 DS3/E3 MIB September 2004 ::= { ds3Compliances 1 } -- units of conformance ds3NearEndConfigGroup OBJECT-GROUP OBJECTS { dsx3LineIndex, dsx3TimeElapsed, dsx3ValidIntervals, dsx3LineType, dsx3LineCoding, dsx3SendCode, dsx3CircuitIdentifier, dsx3LoopbackConfig, dsx3LineStatus, dsx3TransmitClockSource, dsx3InvalidIntervals, dsx3LineLength, dsx3LoopbackStatus, dsx3Channelization, dsx3Ds1ForRemoteLoop} STATUS current DESCRIPTION "A collection of objects providing configuration information applicable to all DS3/E3 interfaces." ::= { ds3Groups 1 } ds3NearEndStatisticsGroup OBJECT-GROUP OBJECTS { dsx3CurrentIndex, dsx3CurrentPESs, dsx3CurrentPSESs, dsx3CurrentSEFSs, dsx3CurrentUASs, dsx3CurrentLCVs, dsx3CurrentPCVs, dsx3CurrentLESs, dsx3CurrentCCVs, dsx3CurrentCESs, dsx3CurrentCSESs, dsx3IntervalIndex, dsx3IntervalNumber, dsx3IntervalPESs, dsx3IntervalPSESs, dsx3IntervalSEFSs, dsx3IntervalUASs, dsx3IntervalLCVs, dsx3IntervalPCVs, dsx3IntervalLESs, dsx3IntervalCCVs, Nicklass Standards Track [Page 51] RFC 3896 DS3/E3 MIB September 2004 dsx3IntervalCESs, dsx3IntervalCSESs, dsx3IntervalValidData, dsx3TotalIndex, dsx3TotalPESs, dsx3TotalPSESs, dsx3TotalSEFSs, dsx3TotalUASs, dsx3TotalLCVs, dsx3TotalPCVs, dsx3TotalLESs, dsx3TotalCCVs, dsx3TotalCESs, dsx3TotalCSESs } STATUS current DESCRIPTION "A collection of objects providing statistics information applicable to all DS3/E3 interfaces." ::= { ds3Groups 2 } ds3FarEndGroup OBJECT-GROUP OBJECTS { dsx3FarEndLineIndex, dsx3FarEndEquipCode, dsx3FarEndLocationIDCode, dsx3FarEndFrameIDCode, dsx3FarEndUnitCode, dsx3FarEndFacilityIDCode, dsx3FarEndCurrentIndex, dsx3FarEndTimeElapsed, dsx3FarEndValidIntervals, dsx3FarEndCurrentCESs, dsx3FarEndCurrentCSESs, dsx3FarEndCurrentCCVs, dsx3FarEndCurrentUASs, dsx3FarEndInvalidIntervals, dsx3FarEndIntervalIndex, dsx3FarEndIntervalNumber, dsx3FarEndIntervalCESs, dsx3FarEndIntervalCSESs, dsx3FarEndIntervalCCVs, dsx3FarEndIntervalUASs, dsx3FarEndIntervalValidData, dsx3FarEndTotalIndex, dsx3FarEndTotalCESs, dsx3FarEndTotalCSESs, dsx3FarEndTotalCCVs, dsx3FarEndTotalUASs } STATUS current Nicklass Standards Track [Page 52] RFC 3896 DS3/E3 MIB September 2004 DESCRIPTION "A collection of objects providing remote configuration and statistics information applicable to C-bit Parity and SYNTRAN DS3 interfaces." ::= { ds3Groups 3 } ds3DeprecatedGroup OBJECT-GROUP OBJECTS { dsx3IfIndex, dsx3FracIndex, dsx3FracNumber, dsx3FracIfIndex } STATUS deprecated DESCRIPTION "A collection of obsolete objects that may be implemented for backwards compatibility." ::= { ds3Groups 4 } ds3NearEndOptionalConfigGroup OBJECT-GROUP OBJECTS { dsx3LineStatusLastChange, dsx3LineStatusChangeTrapEnable } STATUS current DESCRIPTION "A collection of objects that may be implemented on DS3/E3 interfaces." ::= { ds3Groups 5 } ds3NearEndOptionalTrapGroup NOTIFICATION-GROUP NOTIFICATIONS { dsx3LineStatusChange } STATUS current DESCRIPTION "A collection of notifications that may be implemented on DS3/E3 interfaces." ::= { ds3Groups 6 } END Nicklass Standards Track [Page 53] RFC 3896 DS3/E3 MIB September 2004 4. Appendix A - Use of dsx3IfIndex and dsx3LineIndex This Appendix exists to document the previous use if dsx3IfIndex and dsx3LineIndex and to clarify the relationship of dsx3LineIndex as defined in RFC 1407 with the dsx3LineIndex as defined in this document. The following shows the old and new definitions and the relationship: [New Definition]: "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows proper use of ifStackTable. [Old Definition]: "this object is the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." When the "Old Definition" was created, it was described this way to allow a manager to treat the value _as if_ it were an ifIndex, i.e., the value would either be: 1) an ifIndex value or 2) a value that was guaranteed to be different from all valid ifIndex values. The new definition is a subset of that definition, i.e., the value is always an ifIndex value. The following is Section 3.1 from [RFC1407]: Different physical configurations for the support of SNMP with DS3/E3 equipment exist. To accommodate these scenarios, two different indices for DS3/E3 interfaces are introduced in this MIB. These indices are dsx3IfIndex and dsx3LineIndex. External interface scenario: the SNMP Agent represents all managed DS3/E3 lines as external interfaces (for example, an Agent residing on the device supporting DS3/E3 interfaces directly): Nicklass Standards Track [Page 54] RFC 3896 DS3/E3 MIB September 2004 For this scenario, all interfaces are assigned an integer value equal to ifIndex, and the following applies: ifIndex=dsx3IfIndex=dsx3LineIndex for all interfaces. The dsx3IfIndex column of the DS3/E3 Configuration table relates each DS3/E3 interface to its corresponding interface (ifIndex) in the Internet-standard MIB (MIB-II STD 17, [RFC1213]). External&Internal interface scenario: the SNMP Agents resides on an host external from the device supporting DS3/E3 interfaces (e.g., a router). The Agent represents both the host and the DS3/E3 device. The index dsx3LineIndex is used to not only represent the DS3/E3 interfaces external from the host/DS3/E3-device combination, but also the DS3/E3 interfaces connecting the host and the DS3/E3 device. The index dsx3IfIndex is always equal to ifIndex. Example: A shelf full of CSUs connected to a Router. An SNMP Agent residing on the router proxies for itself and the CSU. The router has also an Ethernet interface: +-----+ | | | | | | +---------------------+ |E | | 44.736 MBPS | ds3 M13 Line#A | ds3 C-bit Parity |t | R |---------------+ - - - - - - - - - +------> |h | | | | |e | O | 44.736 MBPS | ds3 M13 Line#B | ds3 C-bit Parity |r | |---------------+ - - - - - - - - - - +------> |n | U | | | |e | | 44.736 MBPS | ds3 M13 Line#C | ds3 C-bit Parity |t | T |---------------+ - - - -- -- - - - - +------> | | | | | |-----| E | 44.736 MBPS | ds3 M13 Line#D | ds3 C-bit Parity | | |---------------+ - - - - -- - - - - +------> | | R | |_____________________| | | | | +-----+ Nicklass Standards Track [Page 55] RFC 3896 DS3/E3 MIB September 2004 The assignment of the index values could for example be: ifIndex (= dsx3IfIndex) dsx3LineIndex 1 NA NA (Ethernet) 2 Line#A Router Side 6 2 Line#A Network Side 7 3 Line#B Router Side 8 3 Line#B Network Side 9 4 Line#C Router Side 10 4 Line#C Network Side 11 5 Line#D Router Side 12 5 Line#D Network Side 13 For this example, ifNumber is equal to 5. Note the following description of dsx3LineIndex: the dsx3LineIndex identifies a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number greater than ifNumber and numbering inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers. If the CSU shelf is managed by itself by a local SNMP Agent, the situation would be: ifIndex (= dsx3IfIndex) dsx3LineIndex 1 Line#A Network Side 1 2 Line#A RouterSide 2 3 Line#B Network Side 3 4 Line#B RouterSide 4 5 Line#C Network Side 5 6 Line#C Router Side 6 7 Line#D Network Side 7 8 Line#D Router Side 8 5. Appendix B - The delay approach to Unavialable Seconds. This procedure is illustrated below for a DS3 C-Bit parity application. Similar rules would apply for other interfaces covered by this MIB. The procedure guarantees that the statistical counters are correctly updated at all times, although they lag real time by 10 seconds. At the end of each 15 minutes interval the current interval counts are transferred to the most recent interval entry and each interval is shifted up by one position, with the oldest being discarded if necessary in order to make room. The current interval Nicklass Standards Track [Page 56] RFC 3896 DS3/E3 MIB September 2004 counts then start over from zero. Note, however, that the signal state calculation does not start afresh at each interval boundary; rather, signal state information is retained across interval boundaries. +----------------------------------------------------------------+ | READ COUNTERS & STATUS INFO FROM HARDWARE | | | |BPV EXZ LOS PCV CCV AIS SEF OOF LOF FEBE RAI | +----------------------------------------------------------------+ | | | | | | | | | | | | | | | | | | | | | | V V V V V V V V V V V +----------------------------------------------------------------+ | ACCUM ONE-SEC STATS, CHK ERR THRESHOLDS, & UPDT SIGNAL STATE | | | |<------------- NEAR END ---------------->| |<---- FAR END ----->| | | |LCV LES PCV CCV PES CES PSES CSES SEFS A/U CCV CES CSES SEFS A/U| +----------------------------------------------------------------+ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | V V V V V V V V V | V V V V | +--------------------------------------+ | +-----------------+ | | ONE-SEC DELAY | | | ONE-SEC DELAY | | | (1 OF 10) | | | (1 OF 10) | | +--------------------------------------+ | +-----------------+ | | | | | | | | | | | | | | | | / / / / / / / / / / / / / / / | | | | | | | | | | | | | | | V V V V V V V V V | V V V V | +--------------------------------------+ | +-----------------+ | | ONE-SEC DELAY | | | ONE-SEC DELAY | | | (10 OF 10) | | | (10 OF 10) | | +--------------------------------------+ | +-----------------+ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | V V V V V V V V V V V V V V V +----------------------------------------------------------------+ | UPDATE STATISTICS COUNTERS | | | |<------------- NEAR END ---------------->| |<---- FAR END ----->| | | |LCV LES PCV CCV PES CES PSES CSES SEFS UAS CCV CES CSES SEFS UAS| +----------------------------------------------------------------+ Note that if such a procedure is adopted there is no current interval data for the first ten seconds after a system comes up. Nicklass Standards Track [Page 57] RFC 3896 DS3/E3 MIB September 2004 noSuchInstance must be returned if a management station attempts to access the current interval counters during this time. It is an implementation-specific matter whether an agent assumes that the initial state of the interface is available or unavailable. 6. Acknowledgments This document was produced by the AToM MIB Working Group. The Editor would like to dedicate a special thanks to C. Mike Heard for providing a top notch doctor review and many helpful suggestions, and to acknowledge D. Fowler, Editor of RFC 2496, T. Cox and K. Tesink Editors of RFC 1407. 7. References 7.1. Normative References [RFC2578] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. [RFC2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB", RFC 2863, June 2000. [ANSI-T1.102] American National Standard for telecommunications - digital hierarchy - electrical interfaces, ANSI T1.102-1987. [ANSI-T1.107] American National Standard for telecommunications - digital hierarchy - formats specification, ANSI T1.107- 1988. [ANSI-T1.107a] ANSI T1.107a-1990. [ANSI-T1.404] American National Standard for telecommunications - Carrier-to-Customer Installation - DS3 Metallic Interface, ANSI T1.404-1989. Nicklass Standards Track [Page 58] RFC 3896 DS3/E3 MIB September 2004 [ANSI-T1.231] American National Standard for Telecommunications -- Layer 1 In- Service Digital Transmission Performance Monitoring T1.231, Sept 1993. [CCITT-G.751] CCITT - Digital Multiplex Equipment Operating at the Third Order Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264 Kbit/s and Using Positive Justification, G.751 [ETSI-T/NA(91)18] European Telecommunications Standards Institute -- ETS "34M" -- Metropolitan Area Network Physical Convergence Layer Procedure for 34.368 Megabits per Second, T/NA(91)18, May 1991. [RFC3593] Tesink, K., "Textual Conventions for MIB Modules Using Performance History Based on 15 Minute Intervals", RFC 3593, September 2003. [ITU-T-M.1400] ITU-T M.1400: Designation For Interconnections Among Network Operators, October 2001. 7.2. Informative References [RFC1213] McCloghrie, K. and M. Rose, "Management Information Base for Network Management of TCP/IP-based internets:MIB-II", STD 17, RFC 1213, March 1991. [RFC1407] Cox, T. and K. Tesink, "Definitions of Managed Objects for the DS3/E3 Interface Type", RFC 1407, January 1993. [RFC2496] Fowler, D., "Definitions of Managed Object for the DS3/E3 Interface Type", RFC 2496, January 1999. [RFC3895] Nicklass, O., Ed., "Definitions of Managed Objects for the DS1, E1, DS2, and E2 Interface Types", RFC 3895, September 2004. [RFC3592] Tesink, K., "Definitions of Managed Objects for the Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) Interface Type", RFC 3592, September 2003. [RFC2494] Fowler, D., "Definitions of Managed Objects for the DS0 and DS0 Bundle Interface Type", RFC 2494, January 1999. Nicklass Standards Track [Page 59] RFC 3896 DS3/E3 MIB September 2004 [RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet-Standard Management Framework", RFC 3410, December 2002. 8. Security Considerations There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. The specific the objects and their sensitivities/vulnerabilities are as follows. Setting the following objects to incorrect values may result in traffic interruptions: dsx3LineType dsx3LineCoding dsx3SendCode dsx3LoopbackConfig dsx3TransmitClockSource dsx3LineLength dsx3Channelization dsx3Ds1ForRemoteLoop In the case of dsx3LineType, for example, both ends of a DS3/E3 must have the same value in order for traffic to flow. In the case of dsx3SendCode and dsx3LoopbackConfig, for another example, traffic may stop transmitting when particular loopbacks are applied. Setting the following objects to an incorrect value will result in the remote end receiving an incorrect Path Identification message, which may result in a connectivity inconsistency: dsx3FarEndEquipCode dsx3FarEndLocationIDCode dsx3FarEndFrameIDCode dsx3FarEndUnitCode dsx3FarEndFacilityIDCode Nicklass Standards Track [Page 60] RFC 3896 DS3/E3 MIB September 2004 Setting the following object to an incorrect value will not harm the traffic, but it may cause a circuit to be mis-identified and thereby create difficulties for service personnel when attempting to troubleshoot a problem: dsx3CircuitIdentifier Setting the following object can cause an increase in the number of traps received by the network management station: dsx3LineStatusChangeTrapEnable The readable objects in this MIB module (i.e., the objects with a MAX-ACCESS other than not-accessible) may be considered sensitive in some environments since, collectively, they provide extensive information about the performance of interfaces in DS3/E3 equipment or networks and can reveal some aspects of their configuration. In such environments it is important to control even GET and NOTIFY access to these objects and possibly to encrypt the values of these objects when sending them over the network via SNMP. SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module. It is RECOMMENDED that implementers consider the security features as provided by the SNMPv3 framework (see [RFC3410], section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy). Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them. Nicklass Standards Track [Page 61] RFC 3896 DS3/E3 MIB September 2004 9. Author's Address Orly Nicklass (editor) RAD Data Communications, Ltd. Ziv Tower, 24 Roul Walenberg Tel Aviv, Israel, 69719 Phone: 9723-765-9969 EMail: orly_n@rad.com Nicklass Standards Track [Page 62] RFC 3896 DS3/E3 MIB September 2004 10. Full Copyright Statement Copyright (C) The Internet Society (2004). This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights. This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/S HE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Intellectual Property The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the IETF's procedures with respect to rights in IETF Documents can be found in BCP 78 and BCP 79. Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr. The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf- ipr@ietf.org. Acknowledgement Funding for the RFC Editor function is currently provided by the Internet Society. Nicklass Standards Track [Page 63]