💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0719.tb captured on 2023-06-16 at 21:42:22.
-=-=-=-=-=-=-
============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0719 11-07-91 ============================================================================= AST ETHERNODE AND SMC CONCENTRATORS/HUBS PROBLEM: When connecting multiple NetWare servers using SMC's (Standard Microsystems Corporation) Concentrators/hubs, the error "file server not found" is displayed on the workstation. If only one file server is connected, a connection can be made. CAUSE: SMC has a documented bug which does not allow connecting multiple servers via their earlier concentrators/hubs. SOLUTION: Customers experiencing this problem should contact SMC for an upgrade to a revision G or higher.