💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0339.tb captured on 2023-06-16 at 21:39:13.
-=-=-=-=-=-=-
AST RESEARCH, INC. TECHNICAL BULLETIN #TB-0339 12/10/87 AST-5250 ASYNC DIALUP - POSSIBLE CONFIGURATION PROBLEMS Here is some additional information that is not contained in the file README that comes on the software diskette. (The version that this information was obtained from was version 4.14 of the AST-5250 Async. Dialup). The setup for AST modems operating at speeds greater than 2400 baud includes a command for MNP error correction in reliable mode (\N2). MNP error correction has been found to cause problems on certain kinds of calls with the AST-5250 Async Dialup. Several examples include: Canadian phone lines and long-distance calls that use TASI multiplexing. It appears that the telephone company equipment is filtering part of the signal in these cases. This can lead to communications errors such as "Master not communicating with PC" or cause System/3X screens to be sent as many as 18 times as reported from a Canadian site that examined the signals with a protocol analyzer. If these errors occur, it may be necessary to change the modem initialization string so that (\N2) becomes (\N1). Additionally, problems have been reported with some modems timing out before the slave sends its identification. There have also been problems reported when customers have used hardware flow control with their modems. Hayes and AST modems appear to function properly with no errors of these types. References: ---------- -AT&T Technical Journal -AST 2400, 2X2400, 2X9600 modem user's manuals -Hayes Smartmodem 2400 user's manual