💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0182b.tb captured on 2023-06-16 at 21:36:54.
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0182B 6-30-86 CC432 WRAP PLUG When running the diagnostics program 'CC432TEST' on the AST CC432 board, it is required that you install the shorting plugs at positions 2, 4 and 8. (Reference Users Manual part number 000140-001, April 1984, page 5-3.) Since these shorting plugs are at 1, 3 and 8 when you are running emulation, it is necessary to remove the cover of the PC and change these shorting plugs before you can run diagnostics. Some users find this inconvenient. The following is a wiring configuration for the wrap plug part number 202034-001 which will allow you to run diagnostics without having to move the shorting plugs to 2, 4 and 8: Connect Pins 2 to 3 4 to 5 to 22 6 to 8 to 20 15 to 17 to 24 Then follow the normal test procedures outlined in Section 5.4, pages 5-4 thru 5-9. NOTE: As a portion of the data is in pictorial form, it is not included here. To obtain a complete copy of this technical bulletin, contact: AST RESEARCH, INC. 2121 Alton Avenue Irvine, California 92714-4992 Attention: Product Support (Technical Bulletin)