💾 Archived View for spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0039.tb captured on 2023-06-16 at 21:35:29.
-=-=-=-=-=-=-
AST RESEARCH TECHNICAL BULLETIN TB-0039 7-31-84 MONOGRAPHPLUS WITH AMDEK MD#310A BLANK SCREEN ON POWER UP When using AMDEK monitor 310A and AST MonoGraphPlus card or IBM monochrome adaptor card, an intermittent blank screen upon power up may occur. We have information from AMDEK Technical Group that a change notice has been published to resolve this problem. A copy of this notice is attached for reference. It is suggested that AMDEK Technical Support be contacted prior to modification of their product. The following phone number is to be used at AMDEK Inc. for support of this problem (312) 595-6890. AMDEK CORP. 2201 Lively Blvd. Elk Grove Village, Illinois 60007 TLX: 25-4786 N O T I C E When the 310A monitor is connected to the IBM-PC (or compatible) and the character display is generated, a sympton can occur in which the character display cannot be seen on the monitor. This symptom can also occur when switching modes as with a Hercules Graphics Card. Should this problem occur with your monitor we recommend one of the following solutions: SHORT TERM SOLUTION: Be sure to always turn on the computer first, then the monitor. LONG TERM SOLUTION: Locate resistor R-203 on the motherboard inside the monitor. Disconnect or cut one leg of the resistor from the motherboard. (When viewed from the rear R-203 is at the top right hand corner of the motherboard.) This modification of the 310A will not void the two year warranty. If you have questions or need additional assistance in making this modification please call our technical support department at (312) 595-6890.