AST RESEARCH TECHNICAL BULLETIN TB-0031 7-17-84 AST MONOGRAPHPLUS TECHNICAL REFERENCE MANUAL In Table 4-1 that is located on page 4-2 of Technical Reference Manual (part no. 000127-002A) there are some corrections necessary under the column "Graphics Mode". A "change page" has recently been distributed to make corrections, but it also contains one error in the table. Listed below is the corrected table. Table 4-1 CRTC Internal Registers Register Text Mode Graphics Mode Number Parameter (decimal/hex) (decimal hex) Units :00 Horizontal total 97/:61 56/:38 Characters :01 Horizontal display 80/:50 42/:2D Characters :02 HSync position 82/:52 48/:30 Characters :03 HSync width 15/:0F 08/:08 Characters :04 Vertical total 25/:19 90/:5A Rows :05 Vertical adjust 06/:06 00/:00 Lines :06 Vertical displayed 25/:19 87/:57 Rows :07 VSync position 25/:19 87/:57 Rows :08 Interlace mode 02/:02 02/:02 ----- :09 Maximum scan line 13/:0D 03/:03 Lines address :0A Cursor start line 11/:0B 00/:00 Lines :0B Cursor end line 12/:0C 00/:00 Lines :0C Screen start 00/:00 00/:00 ----- address (high) :0D Screen start 00/:00 00/:00 ----- address (low) :0E Cursor address 00/:00 00/:00 ----- (high) :0F Cursor address 00/:00 32/:20 ----- (low) :10 Reserved ------ ------ ----- :11 Reserved ------ ------ -----