💾 Archived View for spam.works › mirrors › textfiles › hacking › rampart1.hac captured on 2023-06-14 at 16:56:00.
-=-=-=-=-=-=-
!!WHACKOLAND!WHACKOLAND!! W W H -> HACKING RAMPART <- H A SYSTEMS PT. I A C C K INTRODUCTION K O & O ' IN DEPTH COMMAND ' S SUMMARY S !!WHACKOLAND!WHACKOLAND!! INFO ON RAMPART SYSTEMS ----------------------- RAMPART SYSTEMS ARE USED BY CO'S SUCH AS METRO,MCI,SPRINT,ECT. WE HAVE FOUND THAT THEY ARE USUALLY SET UP LIKE WESTERN UNION'S EASYLINK SYSTEM. HERE IS A EXMAMPLE FOR METRO... YOU DIAL THE LDS SERVICE WHICH IN THIS CASE IS 314/342-1130 THEN YOU WOULD ENTER A CODE SUCH AS XXXXXX, THEN IT WOULD GIVE A CARRIER. YOU HAVE TO HAVE 1200BPS TO CONNECT WITH THIS SYSTEM. HACKING RAMPART --------------- FIRST OFF YOU'LL HAVE TO GET A ACCT. OR CODE TO ACCESS THE RAMPART SYSTEM TO DO THIS YOU'LL NEED TO WRITE A SIMPLE PROGRAM THAT WILL WARDIAL THAT LDS AND ENTER CODES EITHER SEQ. OR RAND., AND DO NOT HAVE IT DIAL A CARRIER LIKE ON A REGULAR CODE HACKER. IF IT IS THE CODE YOU ARE LOOKING FOR IT WILL GIVE A CARRIER IMMEDIATLEY AFTER DIALING IT. IT WILL CONNECT 300 & 1200, BUT WILL ONLY LET YOU ON THE MAIN SYSTEM 1200BPS WHEN IT FINDS A CODE FOR RAMPART HAVE IT CHECK FOR THE CARRIER DETECT, AND RECORD THE CODE'S THAT GET THE CARRIER DETECT. ] HACKING RAMPART ACCT [ OK AFTER YOU HAVE GOTTEN THIS FAR AND ARE CONNECTED TO THE SYSTEM, IT WILL GIVE YOU A '>' PROMPT. YOU CAN EITHER ENTER 'LOG' OR 'ACCT,PW'. WHEN YOU ENTER LOG IT WILL SAY: ACCT OR ID: PASSWORD: BASIC ACCTS ON RAMPART SYSTEMS THAT I HAVE FOUND WERE... ACCOUNT - PASSWORD -------------- ------------------ DEMO : DEMO SYSTEST : SYSMNGR RAMPART : SYSTEST HELP : SYSTEST OR HELP NOTE: THESE AREN'T PRIVLEDGED ACCTS. TO GET A PRIV. ACCT, YOU MUST HAVE THE RUT PASSWORD & ID. RAMPART SYSTEMS COMMAND SUMMARY PT I ------------------------------------ NOTE: YOU SHOULD READ THE INTRODUCTION TO HACKING RAMPART SYSTEMS, BEFORE YOU START ON THIS FILE. OK THIS IS GOING TO MAINLY TELL ABOUT WHAT THE COMMANDS AND SUB-COMMANDS ARE USED FOR ON THE RAMPART SYSTEM. HELP THE HELP FUNCTION ENABLES THE USER TO ENQUIRE ABOUT RAMPART SYSTEM CONCEPTS, COMMANDS, AND SYNTAX. TYPE "HELP HELP" FOR MORE SPECIFIC INFORMATION ON USE OF THE HELP FUNCTION. MORE HELP IS AVAILABLE UNDER THE SUB- TOPICS: HELP ABORT RUN REFERRAL TRUNK-NUMBERS DATABASE CHECK EDIT SEE HACKING RAMPART PT III FOR A SUM- MARY FOLLOWING COMMANDS ------------------------------------- PUT DISPLAY TERMINAL TEST REPORT PRIME ROUTINE LOGOUT ERROR-CODES --------------- ->ABORT ABORT <DEMAND OR ROUTINE> ENABLES THE USER TO ABORT ROUTINE TEST- ING OR SELECTED DEMAND TESTS. TO STOP TESTS ACTIVE ON A SINGLE PORT, PUT THAT PORT OUT OF SERVICE. DEMAND ABORTS WILL NOT COMPLETE UNTIL THE CURRENT TRUNK UNDER TEST HAS BEEN FULLY TESTED. ROUTINE ABORTS ARE THE SAME AS DEMAND ABORTS. > ABORT SUB CMDS < DEMAND ROUTINE ->ABORT DEMAND <TERMINAL/NUMBER> (OR ALL) ABORTS ALL DEMAND TESTS FOR THE SPECIFIED TERMINAL NUMBER. IF NO TERMINAL NUMBER IS GIVEN, ALL DEMAND TESTS FOR THIS TERMINAL ARE ABORTED. IF 'ALL' IS SOECIFIED, ALL DEMAND TESTS IN THE SYSTEM ARE ABORTED. TO DETERMINE THE NUMBER OF A TERMINAL WHICH ORIGINATED A DEMAND REQUEST, USE THE 'DISPLAY PORT' AND 'DISPLAY DEMAND QUEUE' COMMANDS. NOTE: IF A DEMAND TEST IS IN PROGRESS, IT WILL BE ABORTED AFTER THE CURRENT TRUNK HAS COMPLETED TESTING. ->ABORT ROUTINE STOPS ROUTINE TESTING WITHOUT AFFECTING REGULAR START AND END TIMES. ROUTINE TESTING WILL NOT START AGAIN UNTIL THE REGULAR START TIME IS REACHED. ->RUN RUNS THE PROGRAM-NAME RUN'S THE RAMPART UTILITY PROGRAMS 'RUN USE' RUNS THE USER EDITOR(SAME AS 'EDIT' COMMAND) 'RUN CIP' RUNS THE CENTRAL OFFICE FILE COMPILER(TYPE 'HELP DATABASE' FOR AN EXPLANATION OF THE CONTENTS OF THIS FILE) 'RUN TAC' RUNS THE TRUNK FILE COMPILER (SHOULD BE RUN ONLY AFTER RUNNING 'CIP' - TYPE 'HELP DATABASES' FOR A EXPLA- NATION OF THIS FILE) 'RUN CODUMP' RUNS THE UTILITY WHICH DUMPS COI(CENTRAL OFFICE INFORMATION)TO THE SYSTEM LINE PRINTER 'RUN RTGDDMP' RUNS THE UTILITY WHICH DUMPS THE ROUTINE TEST FILES TO THE SYSTEM LINE PRINTER 'RUN DOWN' RUNS THE PROGRAM WHICH SHUTS DOWN RAMPART APPLICATIONS PROGRAMS IN AN ORDERLY FASHION. (DO NOT USE THIS IT IS TO YOUR ADVNTAGE NOT TO FOR IT WILL NOT ALLOW YOU<UNPRIV.> TO USE ANY CMDS.) ->REFERRAL NUMBERS REFERRAL NUMBERS ENABLE THE USER TO QUICKLY SPECIFY A SINGLE TRUNK GROUP IN THE SYSTEM BY ITS NUMERIC REFERRANCE. FOR EXAMPLE, THE TRUNK GROUP 'TG123' FROM OFFICE 'ABC' TO OFFICE 'XYZ' CAN BE SPECIFIED BY A SINGLE NUMBER IN RAMPART COMMANDS RATHER THAN ENTERING THE NEAREND,FAREND, AND GROUP ID IN THIER ENTIRETY. NOTE: THE REFERRAL NUMBER FOR A PART- ICULAR TRUNK GROUP MAY CHANGE IF THE DATABASE IS RE-COMPILED. FORMAT: REF-ERRAL NUMBER RF NUMBER THE EASIEST WAS TO DETERMINE THE REFER- RAL NUMBER OF A TRUNK GROUP IS TO USE THE 'DISPLAY TRUNK' COMMAND. ->DISPLAY TRUNK DISPLAY TRUNK(GROUPS) NEAREND<FAREND> <GROUP^ID> OR DISPLAY TRUNK (GROUP) REFERRAL NUMBER DISPLAYS DATABASE INFORMATION ON THE TRUNK GROUP(S) SPECIFIED. INCLUDED IS REFERRAL NUMBER, NEAREND, FAREND, GROUP ID, NUMBER OF TRUNKS, SYSTEM TRUNK NUMBERS, AND LIMITS DATA. O IF ONLY 'NEAREND' IS SPECIFIED, ALL TRUNK GROUPS ORIGINATING FROM THE OFFICE SPECIFIED ARE DISPLAYED O IF 'NEAREND' AND 'FAREND' ARE SPECIFIED, ALL GROUPS BETWEEN THESE TWO OFFICES ARE DISPLAYED O SPECIFYING 'NEAREND', 'FAREND', AND 'GROUP^ID',OR SPECIFYING THE REFERAL NUMBER UNIQUELY DESCRIBES A SINGLE TRUNK GROUP. ->TRUNK TRUNK NUMBERS RAMPART USES TWO DIFFERENT TRUNK NUMBERING SYSTEMS; NAMELY, USER TRUNK NUMBERS AND SYSTEM TRUNK NUMBERS. USER TRUNK NUMBERS ALWAYS START AT ONE, AND END AT THE NUMBER OF TRUNKS IN THE GROUP. SYSTEM TRUNK NUMBERS ARE THE NUMBERS USED TO ACCESS TRUNKS ON THE SWITCH AND MAY RANGE FROM 0 TO 65000. FOR COMMANDS WHICH REQUIRE TRUNK NUMBERS,THE '/SY' SWITCH SHOULD BE ADDED TO THE COMMAND LINE WHEN REFER- ENCING SYSTEM TRUNK NUMBERS. ->DATABASE RAMPART DATABASE OVERVIEW THE RAMPART USER DATABASE IS COMPRISED OF THE FOLLOWING TWO FILES: (1) CENTR. OFFICE DESCRIPTOR(COD) FILE- THE EQUIPMENT LOCATED IN THE CENTRAL OFFICE KNOWN TO THE SYSTEM. IT CONTAINS SUCH INFO. AS COMMON LANGAUGE CODES, LITERAL CENTRAL OFFICE NAMES, ROTL TYPE AND ACCESS NUMBER, TESTLINE TYPES AND ACCESS NUMBERS,ECT. (2) TRUNK SOURCE FILE- THIS FILE DESCRIBES THE TRUNKS LINKING <CO>IN THE <COD>FILE. IT CONTAINS SUCH INFO AS TRUNK GROUP ID, NUMBER OF TRUNKS IN GROUP, LIMITS DATA, TRANSMIT LEVEL, SIGNALLING,ROUTINE TEST INTERVAL,ECT. THESE FILES CAN BE UPDATED BY THE USER SOURCE EDITOR (USE) PROGRAM (INVOKED BY THE CMDS 'EDIT' & 'RUN USE'). [DATABASE SUB-CMDS] EXAMPLE COD CEN-TRAL^OFFICE TRUNK ->DATABASE COD THIS FILE CONTAINS INFORMATION ON THE EQPT. LOCATED IN <CO> KNOWN TO RAMPRT. FOR DETAILED INFORMATION ON ITS CONT., RUN THE USER SOURCE EDITOR,SPECIFY COD FILE EDIT, INVOKE CHANGE MODE ON AN EXSISTING CENTRAL OFFICE RECORD, AND USE THE HELP FACILITY BUILT INTO THE EDITOR. DATABASE EXAMPLE ---------------- ,-------------------, , #3 EAX ROTL , , (TEST PORT ACCESS , , NUMBER = 5551234), ------------------- : : : ::::::::::::: :::::::::105 RESPONDER: ::::::::::::: ->CHECK THIS COMMAND CAUSES A RAMPART TEST PORT TO TO INITIATE A SELFCHECK SEQUENCE AND RETURN THE SELFCHECK DISPOSITION TO THE REQUESTING TERMINAL. FORMAT: CHECK <PORT> PORT # (OR ALL). ->EDIT INVOKES THE USER SOURCE FILE EDITOR PROGRAM WHICH IS USED TO UPDATE THE RAMPART DATA BASE. THIS PRG. HAS ITS OWN HELP FACILITY. FOR INFO. ON THE RAMPART DATABASE IN GENERAL, TYPE 'HELP DATABASE'. !WHACKOLAND!WHACKOLAND! T READ PART II OF T >T< W HACKING RAMPART FOR W C MORE IN DEPTH CMDS C B AND SUB^CMDS. B !WHACKOLAND!WHACKOLAND! WHACKOLAND (314) 256-8220 DOWNLOADED FROM P-80 SYSTEMS.....