💾 Archived View for uscoffings.net › retro-computing › systems › Tandy › t › dmp130.txt captured on 2023-03-20 at 20:26:03.

View Raw

More Information

⬅️ Previous capture (2022-06-04)

-=-=-=-=-=-=-


#: 55892 S1/The Soapbox
    26-Jan-94  23:39:49
Sb: #55881-#DMP-130 DIP SWITCHES
Fm: Frank Gottschalk 72623,40
To: DANNY E. BASS 71024,1751 (X)

Danny, my DMP130A has a 2 switch and an 8 switch block(s) at the back and may
be different than your DMP130. Hope this helps and this post comes out in
tabular form:

          Tandy Codes                     IBM Codes
       SW2-1     SW2-2                SW2-1      SW2-2
       OFF       OFF =Parallel        ON=Cancel   ON=Error
                                      Code OFF    Buzzer ON
       OFF       ON =600 Baud
       ON        OFF =1200  "         OFF=Cancel   OFF=Error
       ON        ON =2400  "          Code Valid   Buzzer OFF



SW1-1   OFF=Tandy Codes                  ON= IBM Codes
SW1-2   ON= CR=CR                        ON= CR=CR
        OFF= CR=NL                       OFF= CR=NL
SW1-3   ON= LF=NL                        ON= LF=NL
        OFF= LF=LF                       OFF= LF=LF
SW1-4   ON= 12" Form                     ON= 12"Form
        OFF= 11" Form                    OFF= 11"Form
SW1-5   ON= 1" Skip                      ON= 1" Skip
        OFF= NO Skip                     OFF= NO Skip
SW1-6   ON= 1/8" LF                      ON= 1/8" LF
        OFF= 1/6" LF                     OFF= 1/6" LG
SW1-7   ON= IBM Characters               ON= Character Set 2
        OFF= Tandy Characters            OFF= Character Set 1
SW1-8   ON= WP Mode                      ON= Buffer Full=CR
        OFF= DP Mode                     OFF= Buffer Full=NL

Hope this helps.   Frank G.