💾 Archived View for gemini.spam.works › mirrors › textfiles › phreak › incoming.txt captured on 2023-01-29 at 10:37:36.

View Raw

More Information

⬅️ Previous capture (2020-10-31)

-=-=-=-=-=-=-

II==================================II
][                                  ][
|| Incoming Trunk Service Observing ||
II -        -     -       -         II
][                                  ][
||            Written by            ||
II                                  II
][          The Executioner         ][
||                                  ||
II              of the              II
][                                  ][
||    [+] PhoneLine Phantoms [+]    ||
II        -    -    -               II
][==================================][ 
 
    The ITSO (Incoming Trunk Service Observing) feature provides the ability
to perform service observing on incoming 2-wire trunk [per trunk signalling
or CCIS]. The ITSO feature provides a method to determine how effectively the
telefone system serves the customer. This assists the telefone co. in 
maintaining network quality.
    
    The intent of servince observing is to evaluate the completion performance 
of the office's subtending networks. All calls selected for observation must
originate from offices of equal or higher rank in the toll heirarchy and must
terminate in the area served by the toll office. The ESS switch randomly
selects calls for observation. Only one call can be monitored at any given
time for the ITSO feature. Equipment malfunctions, network overloads, or other
problems preventing call completion are detected. The calls are also directly
monitored for transmission quality. Each service observing position, located in
the SES (Service Evaluation System) bureau is capable of monitoring calls.
 
    The information required by the service observer is provided to the SES
bureau from the ESS switch via a dedicated data link and a voice monitoring
channel. A 1200 baud data link is used to transmit call progress data and
control signals between the ESS switch and the SES bureau. The dedicated
one-way voice channel is required for monitoring voice transmission. The
interface is capable of monitoring one call at a time.
 
     The SES has complete control over the SES/ESS interface. The observing
feature is a demand system where the demand originates with the SES. There
are 5 possible control messages that the SES can send to an ESS switch.
They are:
 
   1. ENABLE- This message is accepted when the interface is in the idle state.
      It directs the ESS switch to obtain the next observable call.
 
   2. RELEASE- This message is used to release the present call and return the
      interface to the idle state or to release the present test and return to
      idle state.
 
   3. TONE TEST- This message is used ony if the interface is in the idle
      state. It causes a 1-milliwatt tone to be applied to the voice channel.
 
   4. TERMINATION TEST- This messages is only accepted if the interface is in
      the idle state. It causes a quiet termination to be applied to the voice
      channel for 30 seconds (unless a RELEASE order is sent).
  
   5. DATA ECHO TEST- This message is accepted only if the interface is in the
      idle state. It sends a message to the ESS switch to verify the sanity of
      the data channel. The ESS switch appends a unique 2-character header to
      the received message and outputs the recieved message to the data
      channel.
 
   There are 15 potential call progress messages that the ESS switch can
generate and send to the SES. They are:
 
   1. SEIZURE- This message indicates that the ESS switch has found a candidate
      call. If the SES does not recieve this signal within a period of time
      after being enabled, a RELEASE message is transmitted be the SES.
 
   2. RELEASE AKNOWLEDE- This message is transmitted whenever the ESS switch
      decodes a RELEASE signal deo the SES. The interface returns to the idle
      state and the SES is allowed to attempt to observe a new call.
 
   3. TERMINATION- This message is Xmited when the interface returns to the
      idle state due to an abnormal ending of the call observation in progress,
      or when the tone or termination test times out.
 
   4. INCOMING TRUNK DISCONNECT- This message is Xmitted to the SES for every
      calling party on on-hook occurrence.
 
   5. ON-HOOK- This message is Xmitted to the SES for every called party
      on-hook occurrence.
 
   6. OFF-HOOK- This message is xmitted to the SES for every called party
      off-hook occurrence.   
 
   7. EMERGENCY- This message indicates an emergency announcement is being
      applied to the calling party.
 
   8. 60 IPM- This call progress message indicates that the busy tone is being
      applied to the calling party.
 
   9. 120 IPM- This call progess message indicates that recoreder tone is being
      applied to the calling party.
 
  10. NO CIRCUIT AVAILABLE- This call progress message indicates that a no
      circuit available is being applied to the calling party.
 
  11. VACANT CODE ANNOUNCEMENT- This message indicates that a vacant code 
      announcement is being applied to the calling party.
 
  12. RECORDER- This message indicates that a recorder announcement is being
      applied to the calling party.
 
  13. AUDIBLE RING- This message indicates that audible ringing is being
      applied to the calling party. In the case of a locally terminating call,
      the observer is not bridged onto the call until after answer and is
      therefore unable to detect the actual audible ringing.
 
  14. CALLED NUMBER DIGITS- This message contains the called number of digits.
 
  15. DATA ECHO TEST- This contains the DATA ECHO TEST message.
{ 
       The 4 states of SES/ESS interface are as follows:
 
        o Idle- This is the wait state of the interface. It is the stae to
          which the interface returns after tests and completing observations.
 
        o Active- This state is entered only when the ESS switch recieves an
          ENABLE message frm the SES. Service observing is performed in this
          state. This state is maintained for no moe than 3 minutes (2-wire
          trunks) after seizure.
 
        o Tone Test- This can only be entered from the idle state upon receipt
          of a tone test order. In this state, a 1- milliwatt tone is applied
          to the voice channel. The interface returns to the idle state upon
          the RELEASE message or after a 30 second test.
 
        o Termination Test- This state can only be entered from the idle state 
          upon the TERM. TEST message. In this state a quiet term. is applied
          to the voice channel. The interface returns to the idle state upon
          the RELEASE or after 30 secs.
 
     Action to establish an observation is initiated when the SES send an
ENABLE message to the ESS switch. This message triggers the switch to begin
looking for an observable call. When the switch has found a call, the
SEIZURE and CALLED NUMBER DIGITS messages are transmitted to the SES.
 
     From this point on, the SES observes the progress of the call using the
progress messages.
 
=====================================
=All sysops are allowed to put this =
=file on their BBS's.               =
=====================================
 
(C) 1985 Sexy-Exy & PLP          
 
Dedicated to Christi and Linda.
 
 


X-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-X
 Another file downloaded from:                               NIRVANAnet(tm)

 & the Temple of the Screaming Electron   Jeff Hunter          510-935-5845
 Burn This Flag                           Zardoz               408-363-9766
 realitycheck                             Poindexter Fortran   510-527-1662
 My Dog Bit Jesus                         Suzanne d'Fault      510-658-8078
 New Dork Sublime                         Demented Pimiento    415-864-DORK
 The Shrine                               Tom Joseph           408-747-0778

                          "Raw Data for Raw Nerves"