NAM Programming (Reprogramming) Instructions
For 30+ Cellular Telephones
<--Part 1-->
Presented By:
/E/D/I/S/O/N///C/A/R/T/E/R/
Of
NETWORK 23
24 HOURS
1200/2400 BAUD
(402) 467-2474
-----------------------------------------------------------------------------
PLEASE NOTE: Area specific numbers contained within these programming
instructions may not be accurate for your cellular area.
-----------------------------------------------------------------------------
Programming Instructions for:
DIAMONDTEL MESA90X HANDHELD
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
PRESS FCN 7
ENTER 4 DIGIT SECURITY CODE
ENTER NEW 3 DIGIT UNLOCK CODE
PRESS CLR
PWR up unit
Press "END" and hold within 10 seconds of pwr up
Enter "5132920"
Release END key.
0 SEND DUAL NO
XXXXXXXXXX SEND NO1
_ _ _ _ _ SEND SID1
1 SEND LU1
1 SEND EX1
334 SEND IPCH1
07 SEND ACCOLC1
0 SEND PREF1
10 SEND GIM1
0 SEND RI1
1 SEND DTX1
1 SEND AR1
1234 SEND SEC
1 SEND EE
1 SEND C TONE
0 SEND AL
0 SEND BO
1 SEND BEEP
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
TO RESET NAM FROM THE LIMIT OF 3 PROGRAM ATTEMPTS
PWR up unit
Press "END" and hold within 10 seconds of pwr up
TO RESET NAM OF MESA 90 HANDHELD USE THE CODE "6972814"
Programming Instructions for:
DIAMONDTEL MESA99X HANDHELD
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
PRESS FCN 7
ENTER 4 DIGIT SECURITY CODE
ENTER NEW 3 DIGIT UNLOCK CODE
PRESS CLR
PWR up unit
Press "END" and hold within 10 seconds of pwr up
Enter "5132920"
Release END key.
0 SEND DUAL NO
XXXXXXXXXX SEND NO1
_ _ _ _ _ SEND SID1
1 SEND LU1
1 SEND MIN MARK1
334 SEND IPCH1
07 SEND ACCOLC1
10 SEND GIM1
0 SEND RI1
0 SEND DTX1
0 SEND AR1
1234 SEND SEC
1 SEND CONTINUE D.T.M.F.
0 SEND AUTO LOCK
0 SEND BOOSTER
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
Programming Instructions for:
GATEWAY CP 900 HANDHELD
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
CURRENT UNLOCK CODE CAN NOT BE SEEN AND MUST BE KNOWN TO CHANGE
THE CURRENT UNLOCK CODE.
PRESS MENU
ENTER 03
ENTER CURRENT 4 DIGIT SECURITY CODE
ENTER NEW 4 DIGIT SECURITY CODE
PHONE WILL AUTO EXIT TO READY
ACTION TO STORE DISPLAY
PRESS MENU 99 ENTR SCRTY CODE(FCTRY PRST IS 9999) PROGRAM NAM
_ _ _ _ _ SEND SID
XXXXXXXXXX SEND PHONE NUMBER
0334 SEND IPC
07 SEND ACCOL
10 SEND GIM
1 SEND MOBILE I.D. NUMBER
1 SEND LOCAL USE MARK
2 SEND SYSTEM SELECT (B)
UPON PRESSING SEND THE PHONE WILL CYCLE TO WAIT AND THEN RETURN TO THE
READY MODE.
TO DISPLAY THE NEW PHONE NUMBER:
PRESS RCL 00
Programming Instructions for:
GENERAL ELECTRIC MINI II
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
PRESS FCN 7
ENTER 4 DIGIT SECURITY CODE
ENTER NEW 3 DIGIT UNLOCK CODE
PRESS CLR
PWR up unit
Press and hold END key within 10 seconds of pwr up
Enter "6282905"
Release END key
0 Press SEND DUAL NO
XXXXXXXXXX Press SEND NO1
_ _ _ _ _ Press SEND SID1
1 Press SEND LU1
1 Press SEND EX1
0334 Press SEND IPCH1
07 Press SEND ACCOLC1
0 Press SEND PREF1
10 Press SEND GIM1
0 Press SEND RI1
1 Press SEND DTX1
1 Press SEND AR1
1234 Press SEND SEC
1 Press SEND EE
1 Press SEND C DTMF
0 Press SEND AL
0 Press SEND BEEP
0 Press SEND BO
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
Programming Instructions for:
GENERAL ELECTRIC MINI
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE
FOLLOW THE INSTRUCTIONS THAT FOLLOW
PWR up unit
Press and hold CL key within 10 seconds of pwr up
0Enter "7591122"
Release CL key
XXXXXXXXXX PRESS SEND MIN
123 PRESS SEND UNLOCK
_ _ _ _ _ PRESS SEND SID
1 PRESS SEND LU
1 PRESS SEND MIN MARK
334 PRESS SEND IPCH
07 PRESS SEND ACCOLC
0 PRESS SEND PS
10 PRESS SEND GIM
1 PRESS SEND EE
0 PRESS SEND BOOSTER
1 PRESS SEND AR
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
Programming Instructions for:
MITSUBISHI 800
ACTION TO STORE DISPLAY
PWR up unit
Press and Hold STO within 10 Seconds of pwr up
Enter "5474432"
Release STO
0 Press SEND dUAL
XXXXXXXXXX Press SEND NO1
_ _ _ _ _ Press SEND SId1
1 Press SEND LU1
0 Press SEND MIN Mark
0334 Press SEND IPCH
07 Press SEND ACCOLC
0 Press SEND PS1
10 Press SEND GI1
1234 Press SEND SECUrity
1 Press SEND EE
0 Press SEND dt
1 Press SEND HF
0 Press SEND InHIbit
1 Press SEND C tOnE
0 Press SEND SyS A/B
0 Press SEND dUAL HS
0 Press SEND InHibit Ld
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
Programming Instructions for:
MITSUBISHI 900
ACTION TO STORE DISPLAY
PWR up unit
Press and Hold END key within 10 seconds of pwr up
Enter "6972814"
Release END key
0 Press SEND DUAL NO
XXXXXXXXXX Press SEND NO1
_ _ _ _ _ Press SEND SID1
1 Press SEND LU1
0 Press SEND EX1
0334 Press SEND IPCH1
07 Press SEND ACCOLC1
0 Press SEND PREF1
10 Press SEND GIM1
0 Press SEND RI1
1 Press SEND DTX1
1 Press SEND AR1
1234 Press SEND SEC
1 Press SEND EE
1 Press SEND C DTMF
0 Press SEND AL
0 Press SEND BO
1 Press SEND BEEP
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
TO ENTER TEST MODE HOLD END ON PWR UP-CODE 0944635
Programming Instructions for:
MOTOROLA 8000H
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THIS FUNCTION IS PROVIDED IN STEP 9 OF THE PROGRAMMING
MODE
PWR up unit
Enter STORE #123456123456 RCL
If the phone is fresh from factory then
Enter STORE #000000000000 RCL
If the phone is used or already programmed then
Enter STORE #123456123456 RCL
DISPLAY WILL SHOW 01
PRESS *
_ _ _ _ _ * 02 (SID)
XXX * 03 (Area Code)
XXX XXXX * 04 (Phone #)
14 * 05
07 * 06
00 * 07
123456 * 08
123 * 09
334 * 10
010100 * 11
000 *
PRESS * TO REVIEW ENTRIES
TO BURN NAM: PRESS SEND WHILE 01,02,03, ETC. IS DISPLAYED
SET TO SCAN B MODE BY :
RCL * : PRESS * UNTIL SCAN B MODE SHOWS then:
press store
Programming Instructions for:
MOTOROLA ULTRA CLASSIC HANDHELD
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THE UNLOCK CODE IS PROGRAMMED IN STEP 8 OF THE PROGRAMMING
MODE
FOR NEW PHONE: Press FCN, 0 + Security code entered twice (Factory
preset is 000000), RCL
The message 01 will appear in the display to confirm programming mode.
Press * 01 Press *
1) _ _ _ _ _ Press * 02 Press *
2) XXX Press * 03 Press *
3) XXX XXXX Press * 04 Press *
4) 14 Press * 05 Press *
5) 07 Press * 06 Press *
6) 10 Press * 07 Press *
7) 123456 Press * 08 Press *
8) 123 Press * 09 Press *
9) 0334 Press * 10 Press *
10) 010101 Press * 11 Press *
11) 101 Press * 12 Press *
Review entries by pressing "*" repeatedly.
Press SEND to program phone.
Programming Instructions for:
NEC P300
ACTION TO STORE DISPLAY
THESE INSTRUCTIONS FOR SERIAL NUMBERS AFTER 135-839601
Insert NAM Programming Adapter (NECAM #41-2019) into plug connector on P300
phone bottom.
PWR On
RCL # 0 1 to enter test mode. Phone will display shaded blocks.
RCL # 7 6 to select NAM. Phone will show 76-
Press 0 # to program NAM 1. (NAM 1=0,NAM 2=1,NAM 3=2,NAM 4=3)
RCL # 7 1 to enter programming mode.
XXXXXXXXXX PRESS # MIN
1234 PRESS # LOCK CODE
_ _ _ _ _ PRESS # SID
10 PRESS # GROUP I.D.
0334 PRESS # INITIAL PAGING CH
0 PRESS # SYSTEM SELECT (1=A)
07 PRESS # ACCOLC
1 PRESS # MIN MARK 1
1 PRESS # LOCAL USE
911 PRESS # EMERGENCY NO.
Press Clr (and hold) to exit programming and return to TEST MODE.
Press RCL # 0 2 to burn and exit to standby.
THESE INSTRUCTIONS FOR SERIAL NUMBERS PRIOR TO 135-839601
Insert NAM Programming Cable (41-2019)
PWR on
RCL # 7 6 to enter TEST MODE
Press 0 # to select NAM.
RCL # 7 1
You are now in Programming Mode.
Enter NAM info as above.
Press and hold CLR to exit.
Pwr down.
Programming Instructions for:
NEC P9100
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE
FOLLOW THE INSTRUCTIONS THAT FOLLOW
Make sure NAM battery is fully charged before attempting programming
Switch power on
Press RCL #01 display will then show shaded blocks
For a USED phone - to clear nam and accumulated call timer
Press RCL #39
To program NAM1
Press RCL #760#
To enter programming mode Press RCL #71
XXXXXXXXXX Press # MIN
1234 Press # Lock Code
_ _ _ _ _ Press # SYS. I.D.
10 Press # G.I. Mark
0334 Press # First Paging Channel
0 Press # System Select
07 Press # ACCOLC
0 Press # MIN Mark
1 Press # Local Use
TO EXIT PROGRAM MODE AT THIS TIME PRESS CLR AND HOLD
DISPLAY WILL SHOW TEST MODE
TO EXIT TEXT MODE PRESS RCL#02
IF THE MEMORY IS CLEARED VIA RCL #39 DURING THE PROGRAMMING THEN THE PHONE
WILL AUTOMATICALLY ENTER FULL-LOCK AFTER EXITING THE TEST MODE
TO UNLOCK: FCN #XXXX(4 DIGIT LOCK CODE FOR LAST NAM PROGRAMMED).
Programming Instructions for:
NOKIA P-30
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
PRESS SEL 7 UNLCODE APPEARS ON THE DISPLAY
ENTER 5 DIGIT SECURITY CODE AND THE CURRENT UNLOCK CODE APPEARS IN
THE DISPLAY PRESS CLR AND ENTER THE NEW FOUR DIGIT UNLOCK CODE
PRESS SEL TO STORE THE NEW CODE - NOTE: IF YOU DON'T PRESS SEL WITHIN
FIVE SECONDS THE DISPLAY WILL CLEAR AND CANCEL THE FUNCTION
PWR up unit
Enter *17*2001*12345*
HO-Id must appear on display
Press SEL to view current value
Display will be one step behind TO STORE instructions
_ _ _ _ _ Press SEL ACCESS (SID)
1 Press SEL LOCAL
1 Press SEL PhonE n
XXXXXXXXXX Press SEL CLASS
10 Press SEL PAGE ch
334 Press SEL O-LOAd
07 Press SEL GrouP
10 Press SEL SEC
12345 Press SEL AUTO EXIT PROGRAM MODE
TO EXIT PROGRAMMING MODE AT ANY TIME PRESS "END"
WHEN THE SEL KEY IS PRESSED FOLLOWING THE LAST PARAMETER VALUE, THE PHONE
WILL AUTOMATICALLY EXIT THE NAM PROGRAMMING MODE AND RETURN TO NORMAL
OPERATION
Programming Instructions for:
NOVATEL PTR800
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE
FOLLOW THE INSTRUCTIONS THAT FOLLOW
PWR up unit
Press FCN
Press FCN again
Enter *626776*
Display will show CMT REV and a date code - Press Volume Up
Display will show NAM SELECT1 Press Volume Up
_ _ _ _ _ PRESS # PRESS VOLUME UP SIDH
PRESS VOLUME UP SCM
XXXXXXXXXX PRESS # PRESS VOLUME UP MIN
0333 PRESS # PRESS VOLUME UP IDCCA
0334 PRESS # PRESS VOLUME UP IDCCB
0334 PRESS # PRESS VOLUME UP IPCH
07 PRESS # PRESS VOLUME UP ACCOLC
10 PRESS # PRESS VOLUME UP GIM
123 PRESS # PRESS VOLUME UP LOCK A
456 PRESS # PRESS VOLUME UP LOCK B
1 PRESS # PRESS VOLUME UP OPTION LC
1 PRESS # PRESS VOLUME UP OPTION EX
0 PRESS # PRESS VOLUME UP OPTION PS
0 PRESS # PRESS VOLUME UP OPTION NSC
1 PRESS # PRESS VOLUME UP OPTION EE
1 PRESS # PRESS VOLUME UP OPTION REP
0 PRESS # PRESS VOLUME UP OPTION HA
0 PRESS # PRESS VOLUME UP OPTION HF
0 PRESS # PRESS VOLUME UP OPTION F1
0 PRESS # PRESS VOLUME UP OPTION F2
0 PRESS # PRESS VOLUME UP OPTION F3
0 PRESS # PRESS VOLUME UP OPTION F4
TO EXIT PROGRAMMING MODE AT ANY TIME PRESS FCN END
FCN FCN *6462257* WILL CLEAR THE NAM IF IT HAS BEEN PROGRAMMED MORE THAN
3 TIMES OR IF THE NEED EXISTS TO CLEAR THE MEMORY
Programming Instructions for:
NOVATEL PTR825
ACTION TO STORE DISPLAY
PWR up unit
Press FCN
Press FCN again
Enter *697201*
Display will show CMT REV 972 105 Press Volume Up
1 PRESS # VOL UP NAM SELECT 1
_ _ _ _ _ PRESS # VOL UP SIDH
10 PRESS VOL UP SCM
XXXXXXXXXX PRESS # VOL UP MIN
0333 PRESS VOL UP IDCCA
0334 PRESS VOL UP IDCCB
0334 PRESS # VOL UP IPCH
07 PRESS # VOL UP ACCOLC
10 PRESS # VOL UP GIM
123 PRESS # VOL UP LOCK A
123 PRESS # VOL UP LOCK B
1 PRESS # VOL UP LC
1 PRESS # VOL UP OPTION EX
0 PRESS # VOL UP PS - PREF SYSTEM
0 PRESS VOL UP OPTION NSC
1 PRESS # VOL UP OPTION EE-END TO END
1 PRESS # VOL UP OPTION REP
0 PRESS # VOL UP HORN ALERT
0 PRESS # VOL UP HANDS FREE
0 PRESS # VOL UP OPTION F1
0 PRESS # VOL UP OPTION F2
0 PRESS # VOL UP OPTION F3
1 PRESS # VOL UP OPTION F4 AIR RND UP
0 PRESS # VOL UP OPTION F5 FUTURE USE
0 PRESS # VOL UP OPTION F6 FUTURE USE
0 PRESS # VOL UP OPTION F7 FUTURE USE
Programming will now wrap to beginning SIDH display.
Press VOL UP to review entries
Programming Instructions for:
OKI HANDHELD MODEL # 750
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE
Pwr up unit
Press (*) and (#) simultaneously
Enter 10 digit Sec Code as follows: *12345678#
What follows can be done only once!
The display "Enter NEW PW-Sto"
Enter 0123456789 then press STORE
Pwr unit down.
Pwr up unit
Press MENU and RCL simultaneously
Enter 0123456789 Software Version and
ESN Number in HEX
Clears in 2 secs.
Spd Dial Mem Clear
Press 0 Press STO Def Data Reset
Press 0 Press STO
NAM 1 Mode
Own #111 111-1111
XXX XXX XXXX Press STO Vol Up Security
123456 Press STO Vol Up OPTION
1100 Press STO Vol Up SCM
1010 Press STO Vol Up GIM
10 Press STO Vol Up Unlock #
1234 Press STO Vol Up ACCOLC #
07 Press STO Vol Up IPCH NO.
0334 Press STO Vol Up
_ _ _ _ _ Press STO Vol Up System ID:
At this time you may exit the programming mode by pressing CLR to bypass
the other NAM modules.
Programming Instructions for:
OKI HANDHELD MODEL # 900
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE
Pwr up unit
Press RCL and MENU simultaneously
Enter 10 digit Sec Code as follows: *12345678#
What follows can be done only once!
The display "Enter NEW PW-Sto"
Enter 0123456789 then press STORE.
The display "Re-Enter New PW-Sto"
Enter 0123456789 then press STORE to enter Programming Mode.
IF You don't wish to keep the new password then Pwr unit down.
Software Version and
ESN Number in HEX
Clears in 2 secs.
Spd Dial Mem Clear
Press * Press STO SPD DIAL MEM CLEAR
Press * Press STO DEFAULT DATA CLEAR
NAM 1 Mode
Own #111 111-1111
XXX XXX XXXX Press STO Vol Up MIN
123456 Press STO Vol Up SECURITY
_ _ _ _ _ Press STO Vol Up SYSTEM ID:
0334 Press STO Vol Up IPCH
07 Press STO Vol Up ACCOLC #
15 Press STO Vol Up GROUP I.D.
1234 Press STO Vol Up UNLOCK CODE
1010 Press STO Vol Up STATION CLASS
1110 Press STO Vol Up OPTION
At this time you may exit the programming mode by pressing CLR to bypass
the other NAM modules.
Programming Instructions for:
PANASONIC EB3500
Charged Battery and Nam Adaptor are needed.
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE
- 0000# to enter program mode
_ _ _ _ _ Press STO 01 SIDH
XXXXXXXXXX Press STO 02 OWNDL
0 Press STO 03 PRESYS
334 Press STO 04 IPCH
07 Press STO 05 ACCOLC
10 Press STO 06 GIM
00 Press STO 07 DLMT
10 Press STO 08 SCM
911 Press STO 09 SPDL
1234 Press STO 10 LOCK
1 1 0 1 1 0 0 0 Press STO 11 FCN 1
0 0 0 1 0 1 0 0 Press STO 12 FCN 2
1 1 1 1 0 1 1 1 Press STO 13 FCN 3
STO **
END to program phone
Programming Instructions for:
COLT TRANSPORTABLE
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE
FOLLOW THE INSTRUCTIONS THAT FOLLOW
Phone must be locked, to accomplish: press FUNC 5
Enter: FUNC #626# FUNC
The software revision date will be shown.
Press SEND
This will advance phone through memory locations.
E.S.N. will be displayed, press SEND again.
XXX Press SEND AREA CODE
XXX XXXX Press SEND PHONE NUMBER
_ _ _ _ _ Press SEND SYSTEM ID
07 Press SEND ACCOLC
10 Press SEND GIM
1 Press SEND LOCAL USE MARK
1 Press SEND MIN MARK (MOBILE ID)
123 Press SEND LOCK CODE
0 Press SEND AUTOMATIC LOCK
123 Press SEND CALL RESTRICTION
12 Press SEND CALL COUNTER RESET
1 Press SEND ENABLE HANDSFREE
0 Press SEND DISABLE HORN ALERT
0 Press SEND HA TURN OFF TIME
12 Press SEND TOTAL AIRTIME RESET
TO REVIEW PROGRAMMING AT THIS TIME PRESS SEND.
TO EXIT PROGRAMMING AND STORE DATA AT ANY TIME PRESS
END FUNC END - WAKE UP WILL SOUND, PHONE WILL BE LOCKED
ENTER UNLOCK CODE- 123
SYSTEM PREFERENCE MUST BE KEYPAD SELECTED! PRESS FUNC 7 FOR "A" NON W/L
OR PRESS FUNC 8 FOR "B" W/L SYS.
Programming Instructions for:
DIAMONDTEL MESA 55 TRANSPORTABLE
ACTION TO STORE DISPLAY
PWR up unit
Press "CL" and hold within 10 seconds of pwr up
Enter "1951426"
Current Mobile I.D. will display
XXXXXXXXXX Press SEND MIN
123 Press SEND 1 SECURITY
_ _ _ _ _ Press SEND 2 SID
1 Press SEND 3 LU
1 Press SEND 4 MIN MARK
334 Press SEND 5 IPCH
07 Press SEND 6 ACCOLC
0 Press SEND 7 PREF SYS
10 Press SEND 8 GIM
1 Press SEND 9 EE
1 Press SEND 10 ENBL HANDSFREE
0 Press SEND 11 RI
04 Press SEND 12 AUX 1
07 Press SEND 13 AUX 2
Phone automatically returns to show the 10 digits MIN number at this time
and to indicate that the NAM has been programmed. The END key should be
pressed to burn the NAM.
Programming Instructions for:
DIAMONDTEL MESA95 TRANSPORTABLE
ACTION TO STORE DISPLAY
PWR up unit
Press and hold Clr within 10 Seconds of pwr up
Enter "1951426"
Release Clr
0 Press SEND duaAL no
XXXXXXXXXX Press SEND no1
_ _ _ _ _ Press SEND SId1
1 Press SEND LU1
1 Press SEND E1
334 Press SEND IPCH1
07 Press SEND ACCOLC1
0 Press SEND PS1
10 Press SEND GI1
5 Press SEND t InC1
1234 Press SEND SECUrIty
1 Press SEND EE
0 Press SEND dt
0 Press SEND HF
0 Press SEND InHIbIt
1 Press SEND Ctone
0 Press SEND dIS CU
0 Press SEND dIS IGn
SEnSE
0 Press SEND DUAL HS
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
TO RESET NAM FROM THE LIMIT OF 3 PROGRAM ATTEMPTS
FOLLOW THE BLOCK OF INSTRUCTIONS AT TOP USING "8291112" W/CLR
TO RESET NAM OF MESA 90 HANDHELD USE THE CODE "6972814"
Programming Instructions for:
FUJITSU MOBILE PHONE
ACTION TO STORE DISPLAY
PWR up unit
Unit must be locked to program.
To lock press F+LOCK
PWR down unit.
PWR up unit.
Within 10 seconds press #626#7764726 (#NAM#PROGRAM)
A continuous tone will be heard for 7 seconds.
PRESS AND HOLD THE * KEY WHILE THE TONE SOUNDS,
DO NOT LET GO!
The tone will change to an intermittent tone, then it will stop.
Release the * key.
CONGRATULATIONS!!! YOU ARE NOW IN PROGRAMMING MODE!
_ _ _ _ _ PRESS STOR 1 SIDH
1 PRESS STOR 2 LOCAL
1 PRESS STOR 3 MIN MARK
XXXXXXXXXX PRESS STOR 4 MIN
10 PRESS STOR 5 STATION
0334 PRESS STOR 6 IPCH
07 PRESS STOR 7 ACCOLC
0 PRESS STOR 8 PS
10 PRESS STOR 9 GIM
1234 PRESS STOR 10 LOCK
1 PRESS STOR 11 CALL TIME
2 PRESS STOR 12 AUTO LOCK
1 PRESS STOR 13 CALL REST
PRESS STOR TO REVIEW ENTRIES.
WHEN AT MODE #1 PRESS SEND TO BURN NAM AND RETURN TO NORMAL OPERATION.
IF PROGRAMMING WAS DONE INCORRECTLY A SHORT HIGH TONE WILL BE HEARD, YOU
MUST THEN REPEAT DATA ENTRY. YOU MUST PRESS STOR AFTER EACH ENTRY FOR THE
CHECKSUM FUNCTION TO BE FULFILLED.
Programming Instructions for:
GENERAL ELECTRIC CARFONE XR3000
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THE UNLOCK CODE IS PROGRAMMED IN STEP 2 OF THE PROGRAMMING
MODE
PWR up unit
Press "CL" and hold within 10 seconds of pwr up
Enter "923885"
Serial # will display
Press Send key to advance to first entry
XXXXXXXXXX Press SEND MIN
123 Press SEND UNLOCK
_ _ _ _ _ Press SEND SID
1 Press SEND LU
1 Press SEND MIN MARK
334 Press SEND IPCH
07 Press SEND ACCOLC
0 Press SEND PS
10 Press SEND GIM
0 Press SEND AUX
1 Press SEND HANDS
PRESS SEND TO REVIEW ENTRIES. NOTE: AREA CODE (402) WILL DISPLAY FOR MIN
THEN AUTO SWITCH TO REST OF NUMBER ON DISPLAY - BE PATIENT
PRESS "E" KEY TO COMPLETE PROGRAMMING OF THE XR 3000 AT THIS TIME
Programming Instructions for:
GOLDSTAR SERIES 5000 MOBILE
ACTION TO STORE DISPLAY
PWR up Unit
Press FCN 4 to see the selected NAM. Press * to advance. Select NAM1.
Press FCN, 9, 9, * "Enter Code" will be displayed.
Enter 1234567890
XXXXXXXXXX PRESS MEM Enter MIN
_ _ _ _ _ PRESS MEM Enter System ID
0334 PRESS MEM Enter IPCH
07 (ACCOLC) PRESS MEM Enter OVLD Class
1234 PRESS MEM LOCK CODE
123456 PRESS MEM SECURITY CODE
1234 PRESS MEM ALARM DISARM CODE
0 PRESS MEM PREFFERED SYSTEM
0 PRESS MEM STATION CLASS MARK
1 PRESS MEM HANDS FREE MARK (ON)
1 PRESS MEM LOCAL USE MARK (ON)
1 PRESS MEM MIN MARK (ON)
0 PRESS MEM HORN ALERT (OFF)
0 PRESS MEM OPT. SPEAKER (OFF)
TO SAVE TO NAM NOW PRESS MEM
TO REVIEW ENTRIES USE THE VOLUME UP OR DOWN KEYS
Programming Instructions for:
MITSUBISHI 555,560,600
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
TO PROGRAM THIS FUNCTION YOU MUST BE OUT OF THE PROGRAMMING MODE
ENTER FCN 6 AND THEN ENTER THE NEW 3 DIGIT UNLOCK CODE
PRESS CLR.
To program from keypad remove and discard Nam Pad
PWR up unit
Press and Hold STO key within 10 seconds of pwr up
Enter "5474432"
Release STO key
XXXXXXXXXX Press SEND MIN
123 Press SEND SECURITY CODE
_ _ _ _ _ Press SEND SID
1 Press SEND LU
1 Press SEND MIN MARK
334 Press SEND IPCH1
07 Press SEND ACCOLC1
0 Press SEND PS1
10 Press SEND GIM
1 Press SEND EE
1 Press SEND HANDS FREE
0 Press SEND ROAM INHIBIT
0 Press SEND A/B SELECT
00 Press SEND f3-f0 DUAL HEAD
00 Press SEND f7-f4 LD INH
TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME
Installing the LOCK CODE
To program the customer's lock code, the phone must be out ot the
programming mode.
To program, enter FCN, 6,3-digit security code, the a 3-digit lock code.
Press CLR.
Programming Instructions for:
NEC M3700 SERIES MOBILE
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE
FOLLOW THE INSTRUCTIONS THAT FOLLOW
A NAM PROGRAMMER ADAPTOR (NECAM #41-2012) IS
REQUIRED
PWR UP
TO ENTER TEST MODE:
RCL, #,0,1. WILL CYCLE TO SHADED
TO CLEAR MEMORY:
RCL # 3 9
select nam
RCL # 7 6 0 # nam 1
RCL # 7 6 1 # nam 2
TO ENTER PROGRAMMING MODE:
RCL #71
XXX XXX XXXX PRESS # Telephone No. (MIN)
1234 PRESS # Lock Code
_ _ _ _ _ PRESS # Home Area (SYS I.D.)
10 PRESS # G-NO (Group I.D.)
0334 PRESS # First Paging Channel
0 for wireline PRESS # System Select
07 PRESS # ACCOLC
1 PRESS # ACCESS
1 PRESS # Local Use
To exit PROGRAMMING MODE PRESS CLR and hold TEST MODE will show
to exit TEST MODE RCL #02
IF MEM WAS CLEARED VIA RCL #39, PHONE WILL AUTOMATICALLY ENTER FULL-LOCK
AFTER EXITING THE TEST MODE.
TO UNLOCK PRESS FCN # 1234.
Programming Instructions for:
NOKIA LX-11
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
PRESS SEL,5 THEN ENTER 5 DIGIT SECURITY CODE
PRESS SEL TO RECEIVE DISPLAY OF CURRENT UNLOCK CODE
PRESS 5 NOW TO CLEAR ALL CALL TIMERS
ENTER THE NEW UNLOCK CODE
PRESS SEL TO ACCEPT
PWR up unit
Enter *3001#12345 Then - SEL 9 END
IdEnt IF InFO should appear on display
Pressing END will move you through the parameters
Pressing SND will toggle between choices available
_ _ _ _ _ Press END HO-Id (SID)
1 Press END ACCESS
1 Press END LOCL OPt
XXXXXXXXXX Press END Phonxx
08 Press END St CLASS
334 Press END PAging Ch
07 Press END O-LOAd CLASS
B Press END PrEF SyS
10 Press END grOUP Id
12345 Press END SECUrIty
-------- (Can't be changed) Press END 1 dAtE
00/00/90 (INSTALLATION DATE) Press END 2 dAtE
TO EXIT PROGRAMMING MODE AT ANY TIME PRESS "END" TO STORE LAST PARAMETER
THEN POWER DOWN
WHEN THE "END" KEY IS PRESSED FOLLOWING THE LAST PARAMETER, THE TEXT
Prog donE WILL APPEAR ON DISPLAY
Programming Instructions for:
NOKIA M-10
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THIS FUNCTION IS PROVIDED BY THE SECURITY CODE PROGRAMMED AT THE
TIME OF PROGRAMMING
PWR up unit
Enter *17*3001*1234*
HO-Id must appear on display
Press SEL to view current value
Display will be one step behind TO STORE instructions
_ _ _ _ _ Press SEL ACCESS (SID)
1 Press SEL LOCAL
1 Press SEL PhonE n
XXXXXXXXXX Press SEL CLASS
08 Press SEL PAGE ch
334 Press SEL O-LOAd
07 Press SEL GrouP
10 Press SEL SEC
1234 Press SEL AUTO EXIT PROGRAM MODE
TO EXIT PROGRAMMING MODE AT ANY TIME PRESS "END"
WHEN THE SEL KEY IS PRESSED FOLLOWING THE LAST PARAMETER VALUE, THE PHONE
WILL AUTOMATICALLY EXIT THE NAM PROGRAMMING MODE AND RETURN TO NORMAL
OPERATION
Programming Instructions for:
NOVATEL 8305 TRANSPORTABLE
CA08 SOFTWARE VERSION
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
IF EQUIPMENT IS PROVIDED WITH A MENU KEY THEN ENTER THE MENU PORTION OF
THE PHONE AND DISPLAY AND IF NECESSARY REPROGRAM THE UNLOCK CODE FROM
THERE.
IF PHONE DOES NOT HAVE A MENU KEY THEN THERE CAN BE NO PROGRAMMING OF THE
UNLOCK CODE... THE SECURITY CODE WILL BE ALL THAT IS PROVIDED
Lock Phone by pressing FCN 1
Enter Programming Mode by pressing #259
Screen will display the software revision number
Press Volume Up
Screen will display Phone's E.S.N.
Press Volume Up
Screen will display INIT REP USE SND
Press SEND to erase any numbers stored in the phones memory
Press Volume Up
_ _ _ _ _ Send Vol. Up SIDH system I.D.
XXX XXX XXXX Send Vol. Up MIN mobile I.D.
Must be changed when done Send Vol. Up LOCK CODE 1
programming - BY CUSTOMER
Must be changed when done Send Vol. Up LOCK CODE 2
programming - BY CUSTOMER
SET Vol. Up Option EX extnd adrss
334 press send to change Vol. Up IPCH initial pge
07 Send Vol. Up ACCOLC overload
10 Send Vol. Up GIM group i.d.
333 Vol. Up IDCCA initl a
334 Vol. Up IDCCB initl b
1 Vol. Up REG TBL SIZE
Volume up through the four invalid System I.D. addresses
SET Vol. Up OPTION LU local use
B press send to change Vol. Up OPTION PS (prefered sys)
CLR Vol. Up OPTION IRI rm inhbt
CLR Vol. Up OPTION SSD
SET Vol. Up OPTION QRC qck rcall
SET Vol. Up OPTION QST qck store
SET Vol. Up OPTION WUT wake tone
SET Vol. Up OPTION EE use dtmf
SET Vol. Up OPTION FD use dtmf
SET Vol. Up OPTION MFD ext dtmf
SET Vol. Up OPTION 32D dgt dial
CLR Vol. Up OPTION MLH timer
CLR Vol. Up OPTION LHM timer
CLR Vol. Up OPTION CRU timer dsp
CLR Vol. Up OPTION NLM timer
SET for on CLR for off Vol. Up OPTION HA hrn alert
CLR Vol. Up OPTION ONL diagnostc
END to exit or VOLUME UP to review entries.
Programming Instructions for:
OKI CDL400
ACTION TO STORE DISPLAY
To Enter Programming mode:
Press IN SEQUENCE:
END RCL FUNC CLR SND
Screen shows Entr id
Enter 08693427
XXX XXX XXXX PRESS # PRESS * PHon
_ _ _ _ _ PRESS # PRESS * S id no
0334 PRESS # PRESS * iPCH
07 PRESS # PRESS * ACC oLC
123 PRESS # PRESS * LoC Cod
10 PRESS # PRESS * G id
0000 PRESS # PRESS * Stn CLS
0111 PRESS # PRESS * HORN ALERT, HANDS
FREE, LOCAL USE,
MIN. MARK.
PRESS END AT THIS TIME TO EXIT PROGRAMMING MODE.
__________________________________________________________________________
TO REPROGRAM TELEPHON NUMBER AND SYSTEM I.D. # -
PRESS IN SEQUENCE THE FOLLOWING KEYSTROKES:
FUNC 90 * 123 (SECURITY CODE)
PHon WILL DISPLAY
ENTER NEW PHONE NUMBER
XXX XXX XXXX PRESS # PRESS * PHon
_ _ _ _ _ PRESS # PRESS * S id no
PRESS END AT THIS TIME TO EXIT PROGRAMMING MODE.
___________________________________________________________________________
To Re-Initialize Nam Memory for Handset Programmable Models -
Func 99*
Enter Last 8 digits of S.N.
Press *
Programming Instructions for:
PANASONIC EB362
Charged Battery and Nam Adaptor(Grey Cord w/25pin Connector)are needed.
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE
- 0000# to enter program mode
50 Press SND NAM 1 MODE
_ _ _ _ _ Press STO 01 SIDH
XXXXXXXXXX Press STO 02 OWNDL
1 2 3 Press STO 03 LOCK
0 0 0 0 0 0 0 0 0 0 0 0 (12) Press STO 04 SPDL
00 Press STO 05 SCM
334 Press STO 06 IPCH
07 Press STO 07 ACCOLC
10 Press STO 08 GIM
1 1 0 1 1 1 0 0 Press STO 09 FEATURE A
0 0 0 0 0 1 0 0 Press STO 10 FEATURE B
1 0 0 0 0 0 1 1 Press STO 11 FEATURE C
00 Press STO 12 DLMT
STO **
Turn power off
Programming Instructions for:
PANASONIC EB-500 OR TP-500
ACTION TO STORE DISPLAY
USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE -
THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE
Attach Nam Programmer Cable (Our Stock # 823)
Pwr up unit
Enter *0000# 0
You are now in the NAM 1 Program mode.
_ _ _ _ _ Press STO 01 S.I.D.
XXXXXXXXXX Press STO 02 OWN #
0 Press STO 03 O for W/L system
334 Press STO 04 IPCH
07 Press STO 05 ACCOLC
10 Press STO 06 GIM
00 Press STO 07 Digit Dial Limit
08 Press STO 08 SCM (3watt i.d.)
911 Press STO 09 Rcl 00
1234 Press STO 10 Security Code
11000000 Press STO 11 FUNCTION BYTE 1
00010010 Press STO 12 FUNCTION BYTE 2
10010111 Press STO 13 FUNCTION BYTE 3
TO BURN NAM AT THIS TIME Press STO ** NAM is burned
Turn off unit
Detach programming cable
Programming Instructions for:
RADIO SHACK 17-1002 TRANSPORTABLE
THIS UNIT REQUIRES A SERVICE HANDSET TO BE PROGRAMMED!!!
A Mobira Service Handset (Modified) may be used. It is made from an ME53
or ME57 handset by opening and adding a jumper to the left of the one
factory installed just below the white 24 pin connector joining the top and
bottom PCB's. Also, pins 1 and 14 of the handset connector must be jumpered
at the radio end. To disassemble the handset, carefully pry off the
plastic earpad retaining housing to expose on hexdrive screw. Two other
screws are under the rubber plugs at either side of the microphone. The
handset then splits apart. This is a ticklish job and isn't recommended
except in an extreme case and not with the customer's handset. The
modification does not affect normal operation of the handset. It is not
known if a Radio Shack handset will work the same.
After the Service Handset has been applied -
To enter LOCAL MODE (which takes the phone off the air and allows service
commands to be obeyed) press 01#. The display should clear and noise is
heard from the earpiece.
To enter the NAM programming mode, enter 48#. The display shows 48 briefly
and clears.
ACTION TO STORE DISPLAY
0 _ _ _ _ _ PRESS * (5 Digit SID)
1 1 PRESS *
2 1 PRESS *
3 XXXXXXXXXX PRESS *
4 10 PRESS *
5 334 PRESS *
6 07 PRESS *
7 0 PRESS *
8 10 PRESS *
9 12345 PRESS *
Press * to exit NAM Programming Mode and return to Local Mode.
To enter the NAM reading Mode, press 49#. The display will show 49
Programming Instructions for:
RADIO SHACK 17-1003 TRANSPORTABLE
- 17*1003* To enter program mode. If screen does not clear, enter 1234*
Screen
Programming Instructions for:
UNIDEN CP- 900 THRU 5000 SERIES MOBILES AND TRANSPORTABLES
THIS UNIT REQUIRES A PROGRAMMING HANDSET (MODEL CP-210 DIAGNOSTIC)
Make sure the unit is properly connected to a 13.8 volt supply (cig
lighter) and power on after utility handset is attached.
Upon connecting utility handset to phone, the display will show 1 on the
upper line and OP in the middle.
You are now in the TEST MODE!
Press SELECT, 2, SEND Top will show 2 0 and Current S.I.D.
You are now in the PROGRAM MODE
ACTION TO STORE DISPLAY
0 _ _ _ _ _ PRESS STORE SID
1 1 PRESS STORE LOCAL USE
2 1 PRESS STORE ACCES METH (MIN MARK)
3 XXXXXXXXXX PRESS STORE MIN
4 0334 PRESS STORE INITIAL PAGING CH
5 07 PRESS STORE ACCESS OVERLOAD
6 0 PRESS STORE PREF SYS (O-B,1-A)
7 10 PRESS STORE GROUP I.D. MARK
8 1234 PRESS STORE LOCK CODE (SEE re:)
9 1 PRESS STORE DTMF DURATION
A 0 PRESS STORE AUTO SHUT-OFF
Enter the data for the selected item. If an error is made during data
entry the CLR key can be used to erase single keys.
PRESS SEND to burn NAM. Phone will display PASS. If FAIL is displayed
you must repeat programming sequence.
To read the NAM (review) press SELECT 3 SEND. Enter RCL then the number
of the item that you wish to view. Press the CLR key to exit and return
to test mode.
TO VIEW THE SERIAL NUMBER OF THE UNIT BEING PROGRAMMED -
Press SELECT 4 SEND while in the Test Mode to display the phone's serial
number in decimal form. The manufacturer ID (172) will be displayed on
the top line while the remainder of the serial number will appear on the
bottom line Press the CLR key to return to the Test Mode display.
-------------------------------------------------------------------------------
DEFINITIONS:
XXX - Area Code or Prefix
XXXXXXX - Prefix & Suffix
XXXXXXXXXX - Area Code, Prefix, & Suffix
_ _ _ _ _ - Digits (One Line Per Digit [Sample To Left Is 5 Digits])
MIN* (Mobile Identification Number):
10 digit directory telephone number.
UNLOCK (Lock Code):
3 digit code to unlock radio (WARNING - The radio cannot
be unlocked if this code is forgotten).
NOTE: You can read this code by using the programming procedure.
SID* (Home System Identification):
5 digit number for assigned cellular system.
LU* (Local Use):
0 or 1. 1=local control option and responds to local control messages.
MIN MARK* 0 or 1. 1=home station sends extended address information
upon origination and page response.
IPCH* (Initial Paging Channel in Home):
3 digit number to identify the channel number of the first
paging channel when station is home.
ACCOLC* (Access Overload Class):
2 digit number to identify which overload class field controls
the access attempts.
PS* (Perferred System):
0 or 1. 1=Preferred system is System A
0=Preferred system is System B
GIM* (Group Identification Mark):
2 digit number which indicates how many bits of SID, starting
with the most significant, comprise the GIM.
AUX 0 or 1. 1=Auxiliary signal is enabled for horn relay.
External adapter must be used for this feature.
HANDS 0 or 1. 1=Handsfree feature is enabled.
External adapter must be used for this feature.
ALT LOCK (Alternate Lock Code):
3 digit lock code to be used with the partial lock feature.
This feature is active only with the GE CF-2000 and CF-2500
Carfone models.
This entry is ignored for GE CF-1000 Carfone models.
- These values are Cellular System dependent. Entering an
incorrect value will deny service on the system.
- * * * * * * * * * * * * * * W A R N I N G * * * * * * * * * * * * * * * * * *
When a cellular phone transmits, it sends its Electronic
Identification Number and its assigned telephone number
back to the cellular phone companys computer. This leaves
an electronic trail. If the phone is registered to you and
you change the phone number you run a risk of being tracked
by the Electronic Identification Number.
If the phone is not registered to you, you can be tracked by
the numbers you call frequently. It wouldn't be very smart to
phone home to see how the little woman is doing or check to
see if the latest software came on UPS. And remember, when
you use a cellular phone it goes out over the airways. This
means anyone with the know-how can listen to you. All some
people need is a juicy bit of information and a phone number
and you leave yourself open to all kinds of scams, blackmail,
and legal problems.
* * * M O R E * N O T E S * * *
Most cellular companys do not turn off the numbers that are not
in use. Better yet I do not know of a company that tracks numbers
that are not assigned. They seem to keep the low numbers filled
in. When someone turns in a phone they reassign that number
instead of a new number. If you put a number in your phone, use
a high number. Chances are it is not assigned to anyone. The
calls you make on a unassigned number usually will go unnoticed.
Better yet monitor the number you wish to use with a scanner for
a period of time to check for activity.
Happy foning.....
- * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
NETWORK 23 BBS, 24 HOURS, 1200/2400 BAUD, (402) 467-2474
- * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
This file was downloaded from......
_ _______ _____ _ _ ____ ____ _____
| | | _ | ___| | / /| __|| __ \ | ___|
| | | | | | | | | |/ / | |__ ||__| || |___
| | | | |_| | | | / | __|| _/ |___ |
| | | | _ | | | \ | | | \ | |
| | | | | | | |___| |\ \_| |___| |\ \_____| |
| |____| |_| |_|_______| \__________| \________|
| ____ |_______ _ __ _______
| | | | _ | | | \ | _ _|
| | | | |_| | | | | \ \ | | | |
| | | | _ | | | | |\ \| | | |
| | | | | | | |__| | | \ \ | | |
|_| |___| |_|________| \__| |_|
Call [UK] 081-656-1517
Worldwide +44 81 656 1517
24hrs!!
Downloaded From P-80 Systems 304-744-2253