💾 Archived View for gemini.spam.works › mirrors › textfiles › phreak › BLUEBOXING › blue.box captured on 2022-07-17 at 10:30:29.
⬅️ Previous capture (2022-06-12)
-=-=-=-=-=-=-
BLUE BOX PLANS NOTE TO ALL:THIS IS AN ORIGINAL PHILE FROM THE OSUNY BBS(NOW DEFUNCT)...IT IS STILL A VERY COMMONPLACE FILE, AND MANY LAW ENFORCEMENT AGENCIES DO HAVE A PRINTUP OF THIS FILE...IF YOU WERE EVER CAUGHT WITH A COPY OF THIS PHILE, I HAVE ABSOLUTELY NO IDEA NOR GRASP OF WHAT THE CONSEQUENCES WOULD BE..ALSO NOTE THAT IT IS AN OLD HARDWARE TYPE FILE...UNLESS YOU ARE REALLY INTERESTED IN BUILDING ONE, AND CAN ACCEPT THE CONSEQUENCES OF BEING CAUGHT WITH A HARDWARE BLUE BOX(OUTLINED ON D1'S "PHREAKERS RIGHTS") THEN DO NOT TAKE THIS FILE AND TRY TO USE IT...IT CAN CERTAINLY MEAN NOTHING BUT TROUBLE FOR YOU.... Press [RETURN] \-=-=-=-=-=-=-=-=-=/ \ / \ THE ART AND / \ PRACTICE OF / \ BLUE BOXING / \ / \=-=-=-=-=-=-=-=-=/ =)>ORIGINALLY TYPED BY:<(= ^-NICKIE HALFLINGER-^ ^- & MR. AMERICA -^ THIS IS THE TONE MATRIX FOR A BOX WHICH GENERATES TONES THAT OPERATORS USE TO DIAL..ROTARY WORKS AS WELL, ON OPERATOR LINES, BUT THIS IS TECHNOLOGICAL(!). NOW I AGREE WITH THE OPINION OF A WELL KNOWN PHREAK THAT 'BOXING' IS/WILL BE FOR THE MOST PART DEAD, BUT THIS IS TRADITION... FIRST,YOU DIAL DIR.ASST, OR AN OPER. ETC, THEN YOU BLAST THE LINE WITH A 2600HZ TONE. THIS GIVES YOU THE LINE, THIS IS ALSO HOW MA BELL TRACKS DOWN BLUE BOXERS... Press [RETURN] THERE ARE 2600HZ DETECTORS SYSTEMS, AND EVEN ON OLD #4 CROSSBARS... ONCE ON A OPER.TRUNK LINE, YOU USE YOUR BLUE BOX/ROTARY TO DIAL... SO, IF YOU USE 2600HZ, WHICH IS NECESSARY, UNLESS YOU ARE *VERY* CAREFUL, YOU WILL BE SNAGGED. FINALLY, THIS IS WHAT YOU READ!SO LONG AND HARD FOR: 700 : 1 : 2 : 4 : 7 : 11 : 900 : + : 3 : 5 : 8 : 12 : 1100 : + : + : 6 : 9 : KP : 1300 : + : + : + : 10 : KP2 : 1500 : + : + : + : + : ST : : 900 : 1100 : 1300 : 1500 : 1700 : USE KP TO START A CALL, AND ST TO STOP, WITH THE BELOVED 2600HZ TONE TO DISCONNECT. I ALSO HEAR THAT 2600HZ RESETS SPRINT NODES AND GIVES YOU THEIR INITIAL TONE.. NOW, IF YOU'RE WONDERING ABOUT WHAT TO CALL FROM AN OPERATOR TRUNK, HERE ARE SOME GOODIES TO HELP YOU OUT: XXX+101 - TOLL SWITCHING Press [RETURN] XXX+121 - LOCAL OPERATOR XXX+131 - INFORMATION XXX+141 - RATE & ROUTE XXX+181 - COIN REFUND OPERATOR XXX+11501 - MOBILE OPERATOR XXX+11521 - MOBILE OPERATOR XXX+11511 - CONFERENCE OPERATOR THESE WORK WITH ROTARY OR OPERATORS TONES, BUT ONLY ON OPER. TRUNK LINES... THANKS FOR LISTENING! BLUE BOXES, PART II WHILE READING THE FINE ARTICLE ON THE BLUE BOX I SAW THAT THERE A LOT OF DATA LEFT OUT OF THE DOCUMENT. I HOPE THIS ADDS, IN SOME SMALL WAY, TO THE INFORMATION. Press [RETURN] FIRST THE TONES. WHILE ALL THE INFORMATION IS CORRECT, THE TIMING SPECS WERE NOT INCLUDED. THE TONE PAIRS ARE TO REMAIN ON FOR 1/10 SEC. WITH 1/10 SEC. OF SLIENCE BETWEEN DIGITS. THE 'KP' TONES SHOULD BE SENT FOR 2/10 SEC. A WAY TO DEFEAT THE 2600HZ TRAPS IS TO SEND ALONG WITH THE 2600HZ SOME PINK NOISE(MOST OF THE ENERGY IN THIS SIGNAL SHOULD BE ABOVE 3000HZ, THIS SIGNAL WON'T MAKE IT OVER THE TOLL NETWORK, BUT SHOULD CARRY AS FAR AS YOUR LOCAL TOLL CENTER) SO THAT THE TRAPS WON'T FIND 'PURE' 2600HZ ON THE TRUNK. THIS IS NOT A PERFECTLY SAFE WAY TO BOX, BUT IT SHOULD SLOW DOWN THE DISCOVERY. AS TO USE, THE FIRST THING YOU NEED TO UNDERSTAND IS THAT THERE ARE TWO(2) TYPES OF TOLL COMPLETING TRUNK, INWARD AND OUTWARD. THE NAMES ARE REFERENCE TO THE OFFICE THAT IS SWITCHING THE CALL(THE TOLL CENTER THAT SERVES THE WATS LINE YOU CALLED) AND EACH TYPE OF TRUNK HAS A DIFFERENT CLASS OF SERVICE. FROM AN INWARD TOLL COMPLETING TRUNK, YOU CAN REACH THE DIFFERENT SERVICE OPERATORS, THE TOLL TEST BOARD, AND THE INWARD OPERATOR. SOME OFFICES ALSO ALLOW REMOTE TESTING AND IT IS IN THESE OFFICES THAT YOU CAN ACCESS THE OUTWARD TOLL COMPLETING TRUNKS. THE OUTWARD TRUNKS ALLOW YOU TO MAKE VERIFICATION(EMERGENCY) CALLS, DO Press [RETURN] SERVICE MONITORING(TAPPING), STACK TRUNKS(BUSY OUT ALL TRUNKS BETWEEN LA AND NYC), ENABLE AND DISABLE TSPS POSITIONS, AND IN SOME CASES(ON SOME 4A'S) ISSUE TEMPORARY REROUTING INSTRUCTIONS( SEND ALL CALLS FROM LA TO NYC VIA MIAMI, BOSTON, OR ANY OTHER CLASS 5 OFFICE OR OFFICES). BOTH TYPE OF TRUNK ALLOW YOU TO PLACE A 'STANDARD' CALL WITH A BOX. IN SOME OFFICES, MOSTLY THE SMALL ONES WITH A TOLL TEST BOARD THAT IS UNATTENDED AT NIGHT AND ON WEEKENDS, YOU CAN GET AN OUTWARD TOLL COMPLETING TRUNK AS WELL AS PERFORMING OTHER TEST AND ROUTING FUNCTIONS. YOU DO THIS BY USING THREE DIGIT CODES THAT ARE INVALID EXCHANGES(NOT OF THE PATTERN NNX[SEE NOTE 1]). DURING THE SIXITES THE CODES USED WERE FAIRLY STANDARD AND CONSISTENT, HOWEVER WHEN THE BOXES BECAME POPULAR AND THE PHREAKS STARTED DOING THINGS LIKE ROUTING ALL CALLS FROM DALLAS TO FT. WORTH VIA WASHINGTON D.C. MOTHER STARTED CHANGING THE TEST CODES ON A RANDOM(AS FAR AS I KNOW) BASIS. WHAT I WOULD SUGGEST IS THAT EVERYBODY INTERESTED IN DOING THIS SORT OF THING PICK OUT A NICE QUIET LITTLE OFFICE SOMEWHERE AND WORK ON DISCOVERING THE CODES ACCEPTABLE TO THAT OFFICE. EACH NUMBERING PLAN AREA(NPA, ALSO KNOWN AS AREA CODE) HAS Press [RETURN] AN OFFICE DESIIGNATED AS ITS MASTER OFFICE. THIS OFFICE CONTROLS ALL OF THE OTHER TOLL OFFICES IN THE AREA AS WELL AS SERVING AS A CONCENTRATION POINT FOR MOST OUT OF AREA CALLS. TO ACCESS THE SERVICES OF A NON-MASTER OFFICE YOU NEED IT'S 'CITY CODE', THIS IS A THREE(3) DIGIT CODE THAT IS OF THE FORM 0XX, AND IS SENT AFTER THE AREA CODE[SEE NOTE 2]. AS AN EXAMPLE, THE 'CITY CODE' FOR CANTON, OHIO IS 042; THUS TO REACH THE INWARD OPERATOR IN CANTON, YOU WOULD SEND 'KP-216-042-121-ST' WHERE AS IF YOU WANTED THE INWARD OPERATOR IN CLEVELAND, YOU WOULD SEND 'KP-216-121-ST'. THE REASON THIS IS NECESSARY IS THAT THE OPERATOR IN CLEVELAND CAN'T VERIFY A NUMBER IN CANTON, SO IF YOU WANT TO VERIFY SOMEONE IN CANTON YOU NEED THE CITY CODE. ALSO, MOST AREA MASTER OFFICES HAVE DEDICATED DATA TRUNKS TO THE NETWORK CONTROL CENTER AND THUS DON'T ACCEPT TEST AND REROUTING COMMANDS OVER THE SWITCHED NET- WORK. IN CONCLUSION, THE SWITCHING NETWORK WILL DO A LOT MORE FOR YOU THEN CONNECT YOU TO PEOPLE AND THE SMALL OFFICES THAT REQUIRE A 'CITY CODE' ARE THE TYPE OF OFFICE TO TRY TO BREAK. NICKIE HAFLINGER, THE COVEN. Press [RETURN] NOTE 1: THE NORMAL FORMAT FOR TELEPHONE NUMBERS IS AS FOLLOWS: NYN/NNX-XXXX. WHERE N=ANY DIGIT EXCEPT 1 AND 0; Y=0 OR 1, AND X=ANY DIGIT. YES I KNOW THAT IN SOME AREA CODES THE NNX FORMAT HAS CHANGED TO NXX. THIS IS A NEW OCCURRENCE AND ONLY OCCUR WHERE THERE HAS BE AN OUTRAGEOUS POPULATION INCREASE IN THE LAST FEW YEARS AND ALL OF THE FUNNY EXCHANGES ARE CONNECTED DIRECTLY TO MASTER OFFICES AND THUS DON'T CONFLICT WITH THE 'CITY CODE' FORMAT. NOTE 2: YOU CAN OBTAIN THE 'CITY CODE' FOR A NUMBER BY CALLING RATE AND ROUTE AND ASKING FOR THE 'NUMBERS ROUTE' TO NYN/NNX(I.E. 914/725). OR IF YOU LEAVE ME A MESSAGE WITH THE AREA CODE AND FIRST THREE OF A NUMBER, I WILL GET YOU THE 'CITY CODE'. THIS BULLETIN WILL DEAL ONLY WITH THE BASIC CONTRUCTION, Press [RETURN] ' TROUBLESHOOTING AND ADJUSTMENT OF THE BLUE BOX. IF YOU WOULD LIKE TO KNOW THE SPECIFIC JOB OF ANY PART IN THE CIRCUIT JUST WRITE ME A MSG AND I WILL BE GLAD TO ANS- WER IT. WE ALL KNOW THAT THE TOUCH TONES FREQUENCIES ARE COMPOSED OF TWO TONES (TWO DIFFERENT FREQS.) SO THAT IS THE REASON WHY WE HAVE 2 VCO'S ( VOLTAGE CONTROLLED OSCILATORS). WE WILL CALL THESE VCO#1 AND VCO#2. IF YOU HAVE NOTICED VCO#1 ANS VCO#2 ARE EXACTLY THE SAME TYPE OF CIRCUITS. THAT IS WHY ONLY ONE WAS DRAWN. BUT REMEMBER THAT WHATEVER GOES FOR VCO#1 ALSO GOES FOR VCO#2. BOTH VCO'S ARE COMPOSED OF A HANDFULL OF PARTS. ONE CHIP TWO CAPACITORS 2 RESISTORS AND FIVE POTENTIOMETERS. ALL OF THIS WILL GIVE YOU (WHEN PROPERLY CALIBRATED) ONE OF THE FREQS. NECESSARY (THE OTHER ONE WILL COME FROM VCO#2) FOR THE OPERATION OF THE BB. BOTH OF THESE FREQS. WILL BE MIXED IN THE SPEAKER THUS FORMING THE REQUIRED TONE. Press [RETURN] THIS IS ONE OF THE MOST SOPHISTICATED DESIGNS I HAVE EVER MADE. WHY?. BECAUSE OTHER DESIGNS WILL DRAIN THE BATTERY AFTER 10 - CALLS! THIS DESIGN WILL MAKE THEM LAST 10 MONTHS!!!!!!. BUT NEVER THE LESS DON'T FORGET TO PUT IN A SWITCH FOR ON AND OFF. OK LET'S BUILD THE TWO VCO'S AND CALIBRATE THE UNIT BEFORE WE GET TO THE KEYBOARD CONTRUCTION. VCO CONTRUCTION === =========== TOOLS REQUIRED 1 OCILLISCOPE (RECOMENDED BUT NOT REQUIRED) 1 FREQ. COUNTER (REQUIRED) 1 VOLT METER " " " ELECTRONICS TOOLS (PLIERS,DRILL, SCREWDRIVERS, ETC) PARTS Press [RETURN] R1 1.5K RESISTOR 5% R2 1K RESISTOR 5% C1 .1UF ELECTROLYTIC CAPACITOR 16VDC C2 .01UF ELECTROLYTIC CAPACITOR (MYLAR) 16VDC IC1 2207 VCO CHIP BY EXAR ELECTRINICS REMEMBER THE ABOVE IT IS ONLY FOR VCO#1 BUT THE SAME GOES FOR VCO#2. R3-R4 150 OHM RESISTORS 5% C3-C4 .1 UF ELECTROLITIC CAPACITOR 10VDC P1-P10 200K TRIMMER POT - 20 TURNS DIODES USED IN THE KEYBOARD ARE 1N914 TYPE (40 OF THEM) AND 13 SWITCHES FOR THE KEYBOARD SPST. MOMENTARY. SPKR= YOU CAN USE A TELEPHONE SPEAKER FOR THIS(IT WORKS BEST) BUT REMEMBER TO TAKE OUT THE DIODE THAT IS CONNECTED ACCROSS IT.