💾 Archived View for gemini.spam.works › mirrors › textfiles › hamradio › MODIFICATIONS › hr26001.ham captured on 2022-07-17 at 02:14:18.
⬅️ Previous capture (2022-06-12)
-=-=-=-=-=-=-
HR2600.1 AFTER HOOKING UP MY HR-2600 TO MY PK-232, I FOUND I HAD SOME PROBLEMS USING IT IN AMTOR. SINCE I LOVE TO MODIFY AND "FIX" RIGS, I GRABBED MY TEST EQUIPMENT AND SET OUT TO FIND OUT WHY THERE WAS A LONG SWITCH-OVER DELAY TIME. AFTER A FEW MINUTES, I FOUND OUT THAT THE RECIEVER WAS COMMING UP OK. IT WAS THE MUTE CIRCUT THAT WAS SLOW. I FOUND TWO CAPACITORS THAT WERE RESPONSIBLE FOR THE DELAY IN THE MUTE CIRCUT. TO FIX THE PROBLEM, CHANGE OUT C74 AND C99 (BOTH ARE 4.7uf @ 50VDC) WITH .01uf DISC CAPACITORS WITH A VOLTAGE RATING GREATER THAN 15VDC. THESE CAPACITORS ARE ALSO FOUND IN THE HR-2510 AS WELL. THESE SEEM TO BE C139 AND C99 IN THE HR-2510 IF MY COPY IS RIGHT. THESE CAPACITORS ARE LOCATED NEXT TO THE AUDIO OUTPUT IC (TDA1905) IN THE RADIO. THIS I.C. IS LISTED AS IC2 IN THE HR-2600 AND IC103 IN THE HR-2510. I ALSO FOUND THE S/RF METER TO BE VERY SLOW IN MY RIG. I FIXED THIS BY CHANGING C302 ON THE CONTROL UNIT (LOCATED NEXT TO J304) TO A .01uf DISC CAPACITOR ALSO. THIS CAPACITOR IS ALSO IN THE HR-2510. AFTER THESE MODIFICATIONS, I HAD NO MORE PROBLEMS MAKING ANY CONNECTS IN ANY MODE. 73'S AND ENJOY THE UNIDEN! CRAIG/N7ETV @ WB6MQM LAS VEGAS, NEVADA. 89121