💾 Archived View for gemini.spam.works › mirrors › textfiles › computers › DOCUMENTATION › help.txt captured on 2022-07-16 at 23:37:40.

View Raw

More Information

⬅️ Previous capture (2022-06-12)

-=-=-=-=-=-=-

The following TIPS and TRICKS are provided courtesy of T&J SOFTWARE.
They are not related to ChAoS Online or to Chat With Lisa. But they
do use the same DoorFrame software as Lisa. So if you are having
problems with Lisa, the following information might help:


WILDCAT! 4.0
============

  a LARGE number of conferences. I would suggest picking up a copy
  of a file called FDOORSYS.ZIP written by Tim Rider (Tim can be
  reached on The Source BBS at 310-371-3737). Here is what Tim's
  documentation states:


  specifications of DOOR.SYS, all the conferences that a user is
  joined to are written to line #23 of DOOR.SYS.  32,000 conferences
  takes up a lot of room, and some SysOps have a DOOR.SYS file that may
  end up to be over 100k. Some doors have been choking on the large
  DOOR.SYS, so I wrote this small utility to remove that line."



RENEGADE BBS
============

  doors, try using X00 v1.50+. Several Renegade systems have reported
  problems using BNU with the doors.


  section, [E] System Toggles, then [U] to turn the SWAP FILE 'ON'.

TRIBBS v5.02+
=============

  Set the doors up using the PCBOARD.SYS drop file.


  the amount of time that was actually used. Try using another drop
  file, or copying the DOOR.SYS to a separate directory and then
  telling the door to look there for it.


        in the door such as Bordello, Studs, and Studette.

Remote Access v2.0
==================

  different caller drop file such as DORINFO1.DEF. This is currently
  being examined!

Keyboard Timeouts
=================

  timeout", you will need to set the following environmental variable
  in your AUTOEXEC.BAT.

  SET NO87=ON

  This will turn off your co-processor and allow the door to function
  properly.

Overflow Errors
===============

  counts are set too low -- try raising the tick counts.


  make sure NONE of your security level definitions have the MAXIMUM
  DAILY DOWNLOADS set to more than 32,000 -- anything over that will
  cause an OVERFLOW ERROR in ANY door using DOORFRAME.

Garbled Information on Remote
=============================

  cannot receive or receives garbled information, check and make sure
  you are passing the correct IRQ to the door (if you are running a
  non-standard IRQ).

Graphic Cards (general)
=======================

  came with the card. Use the normal DOS ANSI.SYS for the screens
  to show correctly.


  called TANSI.SYS, use this ansi driver instead of the standard
  ANSI.SYS.

DESQview/X
==========

  have a math coprocessor.

Lockups on certain COM PORTS
============================

  IRQ to the command line or batch file! Example:  LISA LISA.CFG /5

Wildcat! 3.x
============

  you must use the caller drop file DOOR.SYS to make sure the callers 
  remaining time is passed back to Wildcat!



  All of our doors will run on the Wildcat! IM version using DigiFos
  v1.3. I have received TWO different setup routines concerning the
  IM version, here's an example:

  DF LOCK%WCNODEID%           -OR-      DF ON
  CD\DOORS\STUDS                        CD\DOORS\STUDS
  STUDS! STUDS!.CFG /FD                 STUDS! STUDS!.CFG
  CD\WC30                               CD\WC30
  DF OFF                                DF OFF

  Comments on either setup would be greatly appreciated!

Spitfire BBS's
==============

  back to the BBS, switch to using DOOR.SYS instead of SFDOORS.DAT. 
  This happens on some Spitfire configurations when using SFDOORS.DAT.

Using DESQview
==============

  character codes on the local monitor, be sure to load the file
  DVANSI.COM in the main batch file that starts your BBS!