💾 Archived View for gemini.bortzmeyer.org › rfc-mirror › rfc3202.txt captured on 2022-06-04 at 03:00:59.

View Raw

More Information

⬅️ Previous capture (2021-11-30)

-=-=-=-=-=-=-







Network Working Group                                     R. Steinberger
Request for Comments: 3202                             Paradyne Networks
Category: Standards Track                                    O. Nicklass
                                            RAD Data Communications Ltd.
                                                            January 2002


                     Definitions of Managed Objects
               for Frame Relay Service Level Definitions

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2002).  All Rights Reserved.

Abstract

   This memo defines an extension of the Management Information Base
   (MIB) for use with network management protocols in TCP/IP-based
   internets.  In particular, it defines objects for managing the Frame
   Relay Service Level Definitions.

Table of Contents

   1. The SNMP Management Framework ...............................    2
   2. Conventions .................................................    3
   3. Overview ....................................................    3
   3.1. Frame Relay Service Level Definitions .....................    4
   3.2. Terminology ...............................................    5
   3.3. Network Model .............................................    5
   3.4. Reference Points ..........................................    6
   3.5. Measurement Methodology ...................................    8
   3.6. Theory of Operation .......................................    9
   3.6.1. Capabilities Discovery ..................................    9
   3.6.2. Determining Reference Points for Row Creation ...........   10
   3.6.2.1. Graphical Examples of Reference Points ................   11
   3.6.2.1.1. Edge-to-Edge Interface Reference Point Example ......   12
   3.6.2.1.2. Edge-to-Edge Egress Queue Reference Point Example ...   13
   3.6.2.1.3. End-to-End Using Reference Point Example ............   14
   3.6.3. Creation Process ........................................   15
   3.6.4. Destruction Process .....................................   15



Steinberger & Nicklass      Standards Track                     [Page 1]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   3.6.4.1. Manual Row Destruction ................................   15
   3.6.4.2. Automatic Row Destruction .............................   16
   3.6.5. Modification Process ....................................   16
   3.6.6. Collection Process ......................................   16
   3.6.6.1. Remote Polling ........................................   16
   3.6.6.2. Sampling ..............................................   17
   3.6.6.3. User History ..........................................   17
   3.6.7. Use of MIB Module in Calculation of Service Level
   Definitions ....................................................   17
   3.6.8. Delay ...................................................   20
   3.6.9. Frame Delivery Ratio ....................................   20
   3.6.10. Data Delivery Ratio ....................................   21
   3.6.11. Service Availability ...................................   21
   4. Relation to Other MIB Modules ...............................   22
   5. Structure of the MIB Module .................................   23
   5.1. frsldPvcCtrlTable .........................................   23
   5.2. frsldSmplCtrlTable ........................................   23
   5.3. frsldPvcDataTable .........................................   23
   5.4. frsldPvcSampleTable .......................................   24
   5.5. frsldCapabilities .........................................   24
   6. Persistence of Data .........................................   24
   7. Object Definitions ..........................................   24
   8. Acknowledgments .............................................   61
   9. References ..................................................   61
   10. Security Considerations ....................................   63
   11. Authors' Addresses .........................................   63
   12. Full Copyright Statement ...................................   64

1.  The SNMP Management Framework

   The SNMP Management Framework presently consists of five major
   components:

   o  An overall architecture, described in RFC 2571 [1].

   o  Mechanisms for describing and naming objects and events for the
      purpose of management.  The first version of this Structure of
      Management Information (SMI) is called SMIv1 and described in STD
      16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4].  The
      second version, called SMIv2, is described in STD 58, RFC 2578
      [5], RFC 2579 [6] and RFC 2580 [7].

   o  Message protocols for transferring management information.  The
      first version of the SNMP message protocol is called SNMPv1 and
      described in STD 15, RFC 1157 [8].  A second version of the SNMP
      message protocol, which is not an Internet standards track
      protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC




Steinberger & Nicklass      Standards Track                     [Page 2]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


      1906 [10].  The third version of the message protocol is called
      SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574
      [12].

   o  Protocol operations for accessing management information.  The
      first set of protocol operations and associated PDU formats is
      described in STD 15, RFC 1157 [8].  A second set of protocol
      operations and associated PDU formats is described in RFC 1905
      [13].

   o  A set of fundamental applications described in RFC 2573 [14] and
      the view-based access control mechanism described in RFC 2575
      [15].

   A more detailed introduction to the current SNMP Management Framework
   can be found in RFC 2570 [16].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the mechanisms defined in the SMI.

   This memo specifies a MIB module that is compliant to the SMIv2.  A
   MIB conforming to the SMIv1 can be produced through the appropriate
   translations.  The resulting translated MIB must be semantically
   equivalent, except where objects or events are omitted because no
   translation is possible (use of Counter64).  Some machine readable
   information in SMIv2 will be converted into textual descriptions in
   SMIv1 during the translation process.  However, this loss of machine
   readable information is not considered to change the semantics of the
   MIB.

2.  Conventions

   The keywords MUST, MUST NOT, REQUIRED, SHALL, SHALL NOT, SHOULD,
   SHOULD NOT, RECOMMENDED, NOT RECOMMENDED, MAY, and OPTIONAL, when
   they appear in this document, are to be interpreted as described in
   RFC 2119 [22].

3.  Overview

   This MIB module addresses the items required to manage the Frame
   Relay Forum's Implementation Agreement for Service Level Definitions
   (FRF.13 [17]).  At present, this applies to these values of the
   ifType variable in the Internet-standard MIB:

   o  frameRelay (32)

   o  frameRelayService (44)



Steinberger & Nicklass      Standards Track                     [Page 3]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   This section provides an overview and background of how to use this
   MIB module.

3.1.  Frame Relay Service Level Definitions

   The frame relay service level definitions address specific
   characteristics of a frame relay service that can be used to
   facilitate the following tasks:

   o  Evaluation of frame relay service providers, offerings or
      products.

   o  Measurement of Quality of Service.

   o  Enforcement of Service Level Agreements.

   o  Planning or describing a frame relay network.

   The following parameters are defined in FRF.13 [17] as a sufficient
   set of values to accomplish the tasks previously stated.

   o  Delay - The amount of time elapsed, in microseconds, from the time
      a frame exits the source to the time it reaches the destination.
      NOTE: FRF.13 [17] defines this value in terms of milliseconds.

   o  Frame Delivery Ratio - The ratio of the number of frames delivered
      to the destination versus the number of frames sent by the source.
      This ratio can be further divided by inspecting either only the
      frames within the CIR or only the frames in excess of the CIR.

   o  Data Delivery Ratio - The ratio of the amount of data delivered to
      the destination versus the amount of data sent by the source.
      This ratio can be further divided by inspecting either only the
      data within the CIR or only the data in excess of the CIR.

   o  Service Availability - The amount of time the frame relay service
      was not available.  There are three types of availability
      statistics defined in FRF.13 [17]: Mean Time to Repair, Virtual
      Connection Availability, and Mean Time Between Service Outages.
      The later two require information about the scheduled outage time.
      It is assumed that scheduled outage time information will be
      maintained by the network management software, so it is not
      included in the MIB module.

   Consult FRF.13 [17] for more details.






Steinberger & Nicklass      Standards Track                     [Page 4]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


3.2.  Terminology

   o  CIR - The Committed Information Rate (CIR) is the subscriber data
      rate (expressed in bits/second) that the network commits to
      deliver under normal network conditions [18].

   o  DLCI - Data Link Connection Identifier [18].

   o  Logical Port - This term is used to model the Frame Relay
      "interface" on a device [18].

   o  NNI - Network to Network Interface [18].

   o  Permanent Virtual Connection (PVC) - A virtual connection that has
      its end-points and bearer capabilities defined at subscription
      time [18].

   o  Reference Point (RP) - The point of reference within the network
      model at which the calculations or data collection takes place.

   o  UNI - User to Network Interface [18].

3.3.  Network Model

   The basic model, as illustrated in figure 1 below, contains two frame
   relay DTE endpoints connected to a network cloud via a frame relay
   UNI interface.  The network cloud can contain zero or more internal
   frame relay NNI connections that interconnect multiple networks.  The
   calculations and data collection can be performed at any reference
   point within the network.

   +-------------+                                       +-------------+
   | Frame Relay |                                       | Frame Relay |
   | DTE Device  |                                       | DTE Device  |
   +------+------+                                       +------+------+
          |                                                     |
         UNI                                                   UNI
      Connection                                            Connection
          |                                                     |
   +------+------+    NNI     +-------------+    NNI     +------+------+
   |  Network A  +------------+  Network B  +------------+  Network C  |
   +-------------+ Connection +-------------+ Connection +-------------+

                                 Figure 1
                    Frame Relay Network Reference Model






Steinberger & Nicklass      Standards Track                     [Page 5]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


3.4.  Reference Points

   The collection and calculations of the service level definitions
   apply to two reference points within the network.  These two points
   are the locations where the frames are referenced in the collection
   of the service level specific information.  The reference points used
   in the MIB module are shown in figure 2 below.  For completeness, the
   module also allows for proprietary reference points which MAY exist
   anywhere in the network that is not a previously defined reference
   point.  The meaning of the proprietary reference points is
   insignificant unless defined by the device manufacturer.








































Steinberger & Nicklass      Standards Track                     [Page 6]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


      +---------------------------+
      |+-----------+ +-----------+|
      ||           | |Measurement||
      ||Frame Relay---Engine     --(Source RP)----+
      ||DTE        | |(If Exists)||               |
      |+-----------+ +-----------+|               |
      +---------------------------+               |
        Frame Relay Source                        |
       +------------------------------------------+
       |             Frame Relay Network
       |            +----------------------------------+
       |            | +------------------------------+ |
       |            | | +---------+ +---------+      | |
       |            | | |         | | Traffic |      | |
       +--(Ingress RP)--- L1 / L2 --- Policing|      | |
                    | | | Control | | Engine  |      | |
                    | | +---------+ +----|----+      | |
                    | |                  |           | |
                    | |         (Traffic Policing RP)| |
                    | +------------------|-----------+ |
                    |    Ingress Node    |             |
                    |                    |             |
                    |        +-----------|-----------+ |
                    |        |  Intermediate Nodes   | |
                    |        +-----------|-----------+ |
                    |                    |             |
                    |      Egress Node   |             |
                    |     +--------------|-----------+ |
                    |     | (Egress Queue Input RP)  | |
                    |     |              |           | |
                    |     |      +-------+------+    | |
                    |     |      | Egress Queue |    | |
                    |     |      +-------+------+    | |
                    |     |              |           | |
                    |     | (Egress Queue Output RP) | |
                    |     +--------------|-----------+ |
                    +--------------------|-------------+
         Frame Relay Destination         |
      +---------------------------+      +-----------+
      |+-----------+ +-----------+|                  |
      ||           | |Measurement||                  |
      ||Frame Relay---Engine     --(Destination RP)--+
      ||DTE        | |(If Exists)||
      |+-----------+ +-----------+|
      +---------------------------+

                                Figure 2
                     Reference Points (FRF.13 [17])



Steinberger & Nicklass      Standards Track                     [Page 7]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   The MIB variables frsldPvcCtrlTransmitRP and frsldPvcCtrlReceiveRP
   allow the user to view and configure the reference points at which
   the calculations occur.  These variables are specific to the device
   on which they are located.  Frame relay devices act as both frame
   sources and frame destinations.  The definitions in this MIB module
   apply to the interaction of a pair of devices on the network path.
   The same device can potentially use different reference points for
   calculation and collection of the statistics based on whether the
   referenced frame is sent or received by the device.  When the device
   is acting as a frame source, the value of frsldPvcCtrlTransmitRP
   reflects the reference point used for all source calculations
   pertaining to the specified PVC.  When the device is acting as a
   frame destination, the value of frsldPvcCtrlReceiveRP reflects the
   reference point used for all destination calculations pertaining to
   the specified PVC.

   For example, FRF.13 [17] defines an Edge-to-Edge Egress Queue
   measurement domain as a domain in which measurement is performed
   between an Ingress Reference Point and an Egress Queue Input
   Reference Point.  For this domain between a source device and a
   destination device, the value of frsldPvcCtrlTransmitRP for the
   source device would be set to ingTxLocalRP(2) and the value of
   frsldPvcCtrlReceiveRP for the destination device would be set to
   eqiRxLocalRP(4).  While it is usually the case that the reference
   points would be equivalent on the remote device when monitoring
   frames going in the opposite direction, there is no requirement for
   them to be so.

   It can be seen from the above example that a total of four reference
   points are required in order to collect information for both
   directions of traffic flow.  The reference points represent the
   transmit and receive directions at both ends of a PVC.  If a device
   has knowledge of the information from the remote device, it is
   possible to collect the statistics from a single device.  This is not
   always the case.  In most instances, two devices will need to be
   monitored to capture a complete description of the service level on a
   PVC.  The reference points a single device is capable of monitoring
   are contained in the frsldRPCaps object.

3.5.  Measurement Methodology

   This document neither recommends nor suggests a method of
   implementation.  This is left to the device manufacturer and should
   be independent of the data that is actually collected.

   Periodic collection of this data can be performed through either
   polling of the data table, use of the sample tables or use of the
   user history group of RFC 2021 [19].



Steinberger & Nicklass      Standards Track                     [Page 8]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


3.6.  Theory of Operation

   The following sections describe how to use this MIB module.  They
   include row handling, data collection and data calculation.  The
   recommendations here in are suggestions as to implementation and do
   not infer that they are the only method that can be used to perform
   such operations.

3.6.1.  Capabilities Discovery

   Three objects are provided specifically to aid the network manager in
   discovering the capabilities of the device with respect to this MIB
   module.

   o  frsldPvcCtrlWriteCaps  This object reports the write capabilities
                             of the PVC Control Table.  Use this object
                             to determine which objects can be modified.
                             This need only be referenced if row
                             creation or modification is to be
                             performed.

   o  frsldSmplCtrlWriteCaps This object reports the write capabilities
                             of the Sample Control Table.  Use this
                             object to determine which objects can be
                             modified.  The group need only be
                             referenced if the sample tables will be
                             used to collect historical information.

   o  frsldRPCaps            This object reports the reference points at
                             which the device is capable of collecting
                             information.  This object needs to be
                             referenced if row creation is to be
                             performed in the PVC Control Table.
                             Devices can only create rows containing
                             supported reference points.

   These objects do not imply that there is no need for an Agent
   Capabilities macro for devices that do not fully support every object
   in this MIB module.  They are provided specifically to aid in the
   ensured network management operations of this MIB module with respect
   to row creation and modification.

   An additional four objects are provided to report and control memory
   the utilization of this MIB module.  These objects are
   frsldMaxPvcCtrls, frsldNumPvcCtrls, frsldMaxSmplCtrls are
   frsldNumSmplCtrls.  Together, they allow a manager to control the





Steinberger & Nicklass      Standards Track                     [Page 9]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   amount of memory allocated for specific utilization by this MIB
   module.  This is done by setting the maximum allowed allocation of
   controls.

3.6.2.  Determining Reference Points for Row Creation

   The performance of a PVC is monitored by evaluating the uni-
   directional flow of frames from an ingress point to an egress point.
   Reference points describe where each of the two measurements are
   made.  Monitoring both of the uni-directional flows that make-up the
   PVC frame traffic requires a total of four reference points as shown
   in Figures 3 through 5.  A monitoring point that evaluates traffic is
   restricted to counting frames that pass the reference points hosted
   locally on the monitoring point.  Thus, if the monitoring point is
   near the ingress point of the flow, it will count the frames entering
   into the frame relay network.  The complete picture of frame loss for
   the uni-directional flow requires information from the downstream
   reference point located at another (remote) monitoring point.

   The local monitoring point MAY be implemented in such way that the
   information from the downstream monitoring point is moved to the
   local monitoring point using implementation-specific mechanisms.  In
   this case all information required to calculate frame loss becomes
   available from the local measurement point.  The local measurement
   point agent is capable of reporting all the objects in the
   FrsldPvcDataEntry row - the counts for offered frames entering the
   network and delivered frames exiting the network.

   Alternatively, the local monitoring point MAY be restricted to counts
   of frames observed on the local device only.  In this case, the
   objects of the FrsldPvcDataEntry row reporting what happened on the
   remote device are not available.

   The following list shows the possible valid reference points for an
   FRF.13 SLA from the source reference point to the destination
   reference point in both directions.

   o  Local Information Only

         Local Device:  srcLocalRP, desLocalRP
         Remote Device: srcLocalRP, desLocalRP

   o  Remote Information Only

         Local Device:  srcRemoteRP, desRemoteRP
         Remote Device: srcRemoteRP, desRemoteRP





Steinberger & Nicklass      Standards Track                    [Page 10]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   o  Mixed Two Device Model 1 (Local Device Always Transmitter)

         Local Device:  srcLocalRP, desRemoteRP
         Remote Device: srcLocalRP, desRemoteRP

   o  Mixed Two Device Model 2 (Local Device Always Receiver)

         Local Device:  srcRemoteRP, desLocalRP
         Remote Device: srcRemoteRP, desLocalRP

   o  Mixed One Device Model 1 (Directional Rows)

         First Row:  srcRemoteRP, desLocalRP (Receiver Row)
         Second Row: srcLocalRP, desRemoteRP (Sender Row)

   o  Mixed One Device Model 2 (Device Based Rows)

         First Row:  srcLocalRP, desLocalRP (Local Row)
         Second Row: srcRemoteRP, desRemoteRP (Remote Row)

   Each of the above combinations is valid and provides the same
   information.

   The following steps are recommended to find which reference points
   need to be configured:

   1) Locate both of the devices at either end of the PVC to be
      monitored.

   2) Determine the capabilities by referencing the frsldRPCaps object
      of each device.

   3) Locate the best combination of the two devices such that the
      necessary reference points are all represented.

   4) If any one of the necessary reference points does not exist in the
      combination of the two devices, it is not possible to monitor the
      FRF.13 defined SLA between the two reference point on the PVC.

3.6.2.1.  Graphical Examples of Reference Points

   FRF.13 [17] defines three specific combinations of reference points:
   Edge-to-Edge Interface, Edge-to-Edge Egress Queue and End-to-End.

   Examples of valid reference points that may be used for each of these
   are discussed in the sections below.





Steinberger & Nicklass      Standards Track                    [Page 11]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   It is often the case that a device knows as a minimum either only
   local information or both local and remote information.  Because
   these are two common examples, each will be illustrated below.

3.6.2.1.1.  Edge-to-Edge Interface Reference Point Example

            Device 1                               Device 2
         +-------------+                        +-------------+
         |   Ingress   |                        |   Egress    |
         |   +-----+   |                        |   +-----+   |
         |(A)|     |   |      Traffic Flow      |   |     |(B)|
      -->-->--     -->-->-->-->-->-->-->-->-->-->-->-     -->-->-->
         |   |     |   |   From Device 1 to 2   |   |     |   |
         |   +-----+   |                        |   +-----+   |
         |             |                        |             |
         |   Egress    |                        |   Ingress   |
         |   +-----+   |                        |   +-----+   |
         |(D)|     |   |      Traffic Flow      |   |     |(C)|
      <--<--<-     -<--<--<--<--<--<--<--<--<--<--<--     --<--<--
         |   |     |   |   From Device 2 to 1   |   |     |   |
         |   +-----+   |                        |   +-----+   |
         +-------------+                        +-------------+

            where (A), (B), (C) and (D) are reference points

                                Figure 3

   For devices with only local knowledge, one row is required on each
   device as follows:

   (A) frsldPvcCtrlTransmitRP for Device 1 = ingTxLocalRP(2)

   (B) frsldPvcCtlrReceiveRP for Device 2 = eqoRxLocalRP(5)

   (C) frsldPvcCtrlTransmitRP for Device 2 = ingTxLocalRP(2)

   (D) frsldPvcCtlrReceiveRP for Device 1 = eqoRxLocalRP(5)

   In which a single row is created on Device 1 containing reference
   points (A) and (D), and a single row is created on Device 2
   containing reference points (C) and (B).

   For devices with both local and remote knowledge, the two rows can
   exist in any combination on either device.  For this example, the
   transmitting devices will be responsible for information regarding
   the flow for which they are the origin.  Only one row is required per
   device for this example.




Steinberger & Nicklass      Standards Track                    [Page 12]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   (A) frsldPvcCtrlTransmitRP for Device 1 = ingTxLocalRP(2)

   (B) frsldPvcCtlrReceiveRP for Device 1 = eqoRxRemoteRP(11)

   (C) frsldPvcCtrlTransmitRP for Device 2 = ingTxLocalRP(2)

   (D) frsldPvcCtlrReceiveRP for Device 2 = eqoRxRemoteRP(11)

3.6.2.1.2.  Edge-to-Edge Egress Queue Reference Point Example

            Device 1                               Device 2
         +-------------+                        +-------------+
         |   Ingress   |                        |   Egress    |
         |   +-----+   |                        |   +-----+   |
         |(A)|     |   |      Traffic Flow      |(B)|     |   |
      -->-->--     -->-->-->-->-->-->-->-->-->-->-->-     -->-->-->
         |   |     |   |   From Device 1 to 2   |   |     |   |
         |   +-----+   |                        |   +-----+   |
         |             |                        |             |
         |   Egress    |                        |   Ingress   |
         |   +-----+   |                        |   +-----+   |
         |   |     |(D)|      Traffic Flow      |   |     |(C)|
      <--<--<-     -<--<--<--<--<--<--<--<--<--<--<--     --<--<--
         |   |     |   |   From Device 2 to 1   |   |     |   |
         |   +-----+   |                        |   +-----+   |
         +-------------+                        +-------------+

            where (A), (B), (C) and (D) are reference points

                                Figure 4

   For devices with only local knowledge, one row is required on each
   device as follows:

   (A) frsldPvcCtrlTransmitRP for Device 1 = ingTxLocalRP(2)

   (B) frsldPvcCtlrReceiveRP for Device 2 = eqiRxLocalRP(4)

   (C) frsldPvcCtrlTransmitRP for Device 2 = ingTxLocalRP(2)

   (D) frsldPvcCtlrReceiveRP for Device 1 = eqiRxLocalRP(4)

   In which a single row is created on Device 1 containing reference
   points (A) and (D), and a single row is created on Device 2
   containing reference points (C) and (B).






Steinberger & Nicklass      Standards Track                    [Page 13]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   For devices with both local and remote knowledge, the two rows can
   exist in any combination on either device.  For this example, the
   transmitting devices will be responsible for information regarding
   the flow for which they are the origin.  Only one row is required per
   device for this example.

   (A) frsldPvcCtrlTransmitRP for Device 1 = ingTxLocalRP(2)

   (B) frsldPvcCtlrReceiveRP for Device 1 = eqiRxRemoteRP(10)

   (C) frsldPvcCtrlTransmitRP for Device 2 = ingTxLocalRP(2)

   (D) frsldPvcCtlrReceiveRP for Device 2 = eqiRxRemoteRP(10)

3.6.2.1.3.  End-to-End Using Reference Point Example

            Device 1                               Device 2
         +-------------+                        +-------------+
         |   Source    |                        | Destination |
         |   +-----+   |                        |   +-----+   |
         |(A)|     |   |      Traffic Flow      |   |     |(B)|
      -->-->--     -->-->-->-->-->-->-->-->-->-->-->-     -->-->-->
         |   |     |   |   From Device 1 to 2   |   |     |   |
         |   +-----+   |                        |   +-----+   |
         |             |                        |             |
         | Destination |                        |   Source    |
         |   +-----+   |                        |   +-----+   |
         |(D)|     |   |      Traffic Flow      |   |     |(C)|
      <--<--<-     -<--<--<--<--<--<--<--<--<--<--<--     --<--<--
         |   |     |   |   From Device 2 to 1   |   |     |   |
         |   +-----+   |                        |   +-----+   |
         +-------------+                        +-------------+

            where (A), (B), (C) and (D) are reference points

                                Figure 5

   For devices with only local knowledge, one row is required on each
   device as follows:

   (A) frsldPvcCtrlTransmitRP for Device 1 = srcLocalRP(1)

   (B) frsldPvcCtlrReceiveRP for Device 2 = desLocalRP(1)

   (C) frsldPvcCtrlTransmitRP for Device 2 = srcLocalRP(1)

   (D) frsldPvcCtlrReceiveRP for Device 1 = desLocalRP(1)




Steinberger & Nicklass      Standards Track                    [Page 14]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   In which a single row is created on Device 1 containing reference
   points (A) and (D), and a single row is created on Device 2
   containing reference points (C) and (B).

   For devices with both local and remote knowledge, the two rows can
   exist in any combination on either device.  For this example, the
   transmitting devices will be responsible for information regarding
   the flow for which they are the origin.  Only one row is required per
   device for this example.

   (A) frsldPvcCtrlTransmitRP for Device 1 = srcLocalRP(1)

   (B) frsldPvcCtlrReceiveRP for Device 1 = desRemoteRP(7)

   (C) frsldPvcCtrlTransmitRP for Device 2 = srcLocalRP(1)

   (D) frsldPvcCtlrReceiveRP for Device 2 = desRemoteRP(7)

3.6.3.  Creation Process

   In some cases, devices will automatically populate the rows of PVC
   Control Table and potentially the Sample Control Table.  However, in
   many cases, it may be necessary for a network manager to manually
   create rows.

   Manual creation of rows requires the following steps:

   1) Ensure the PVC exists between the two devices.

   2) Determine the necessary reference points for row creation.

   3) Create the row(s) in each device as needed.

   4) Create the row(s) in the sample control tables if desired.

3.6.4.  Destruction Process

3.6.4.1.  Manual Row Destruction

   Manual row destruction is straight forward.  Any row can be destroyed
   and the resources allocated to it are freed by setting the value of
   its status object (either frsldPvcCtrlStatus or frsldSmplCtrlStatus)
   to destroy(6).  It should be noted that when frsldPvcCtrlStatus is
   set to destroy(6) all associated sample control, sample and data
   table rows will also be destroyed.  Similarly, when
   frsldSmplCtrlStatus is set to destroy(6) all sample rows will also be





Steinberger & Nicklass      Standards Track                    [Page 15]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   destroyed.  The frsldPvcCtrlPurge objects do not apply to manual row
   destruction.  If the row is set to destroy(6) manually, the rows are
   destroyed as part of the set.

3.6.4.2.  Automatic Row Destruction

   Rows is the tables may be destroyed automatically based on the
   existence of the DLCI on which they rely.  This behavior is
   controlled by the frsldPvcCtrlPurge and frsldPvcCtrlDeleteOnPurge
   objects.  When a DLCI no longer exists in the device, the data in the
   tables has no relation to anything known on the network.  However,
   there may be some need to keep the historic information active for a
   short period after the destruction or removal of a DLCI.  If the
   basis for the row no longer exists, the row will be destroyed at the
   end of the purge interval that is controlled by frsldPvcCtrlPurge.

   The effects of automatic row destruction are the same as manual row
   destruction.

3.6.5.  Modification Process

   All read-create items in this MIB module can be modified at any time
   if they are fully supported.  Write access is not required.  To
   simplify the use of the MIB frsldPvcCtrlWriteCaps and
   frsldSmplCtrlWriteCaps state which of the read-create variables can
   actually be written on a particular device.

3.6.6.  Collection Process

3.6.6.1.  Remote Polling

   This MIB module supports data collection through remote polling of
   the free running counters in the PVC Data Table.  Remote polling is a
   common method used to capture real-time statistics.  A remote
   management station polls the device to collect the desired
   information.  It is recommended all statistics for a single PVC be
   collected in a single PDU.

   The following objects are designed around the concept of real-time
   polling:

   o  frsldPvcDataMissedPolls
   o  frsldPvcDataFrDeliveredC
   o  frsldPvcDataFrDeliveredE
   o  frsldPvcDataFrOfferedC
   o  frsldPvcDataFrOfferedE
   o  frsldPvcDataDataDeliveredC
   o  frsldPvcDataDataDeliveredE



Steinberger & Nicklass      Standards Track                    [Page 16]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   o  frsldPvcDataDataOfferedC
   o  frsldPvcDataDataOfferedE
   o  frsldPvcDataHCFrDeliveredC
   o  frsldPvcDataHCFrDeliveredE
   o  frsldPvcDataHCFrOfferedC
   o  frsldPvcDataHCFrOfferedE
   o  frsldPvcDataHCDataDeliveredC
   o  frsldPvcDataHCDataDeliveredE
   o  frsldPvcDataHCDataOfferedC
   o  frsldPvcDataHCDataOfferedE
   o  frsldPvcDataUnavailableTime
   o  frsldPvcDataUnavailables

3.6.6.2.  Sampling

   The sample tables provide the ability to historically sample data
   without requiring the additional overhead of polling.  At key
   periods, a network management station can collect the samples needed.
   This method allows the manager to perform the collection of data at
   times that will least affect the active network traffic.

   The sample data can be collected using a series of SNMP getNext or
   getBulk operations.  The value of frsldPvcSmplIdx increments with
   each new collection bucket.  This allows the managers to skip
   information that has already been collected.  However, care should be
   taken in that the value can roll over after a long period of time.

   The start and end times of a collection period allow the manager to
   know what the actual period of collection was.  It is possible for
   there to be discontinuities in the sample table, so both start and
   end should be referenced.

3.6.6.3.  User History

   User history, as defined in RFC 2021 [19], is an alternative
   mechanism that can be used to get the same benefits as the sample
   table by using the objects provided for real-time polling.  Some
   devices MAY have the ability to use user history and opt not to
   support the sample tables.  If this is the case, the information from
   the data table can be used to define a group of user history objects.

3.6.7.  Use of MIB Module in Calculation of Service Level Definitions

   The objects in this MIB module can be used to calculate the
   statistics defined in FRF.13 [17].  The description below describes
   the calculations for one direction of the data flow, i.e., data sent
   from local transmitter to a remote receiver.  A complete set of
   bidirectional information would require calculations based on both



Steinberger & Nicklass      Standards Track                    [Page 17]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   directions.  For the purposes of this description, the reference
   points used SHOULD consistently represent data that is sent by one
   device and received by the other.

   A complete evaluation requires the combination of two uni-directional
   flows.  It is possible for a management station to combine all of the
   calculated information into one conceptual row.  Doing this requires
   that each of the metrics are collected for both flow directions and
   grouped by direction  If the information is split between two
   devices, the management station must know which two devices to
   communicate with for the collection of all information.  The grouping
   of information SHOULD be from ingress to egress in each flow
   direction.

   The calculations below use the following terminology:

   o  DelayAvg

         The average delay on the PVC.  This is represented within the
         MIB module by frsldPvcSmplDelayAvg.

   o  FrDeliveredC

         The number of frames received by the receiving device through
         the receive reference point that were delivered within CIR.
         This is represented within the MIB module by one of
         frsldPvcDataFrDeliveredC, frsldPvcDataHCFrDeliveredC,
         frsldPvcSmplFrDeliveredC, or frsldPvcSmplHCFrDeliveredC.

   o  FrDeliveredE

         The number of frames received by the receiving device through
         the receive reference point that were delivered in excess of
         CIR.  This is represented within the MIB module by one of
         frsldPvcDataFrDeliveredE, frsldPvcDataHCFrDeliveredE,
         frsldPvcSmplFrDeliveredE, or frsldPvcSmplHCFrDeliveredE.

   o  FrOfferedC

         The number of frames offered by the transmitting device through
         the transmit reference point that were sent within CIR.  This
         is represented within the MIB module by one of
         frsldPvcDataFrOfferedC, frsldPvcDataHCFrOfferedC,
         frsldPvcSmplFrOfferedC, or frsldPvcSmplHCFrOfferedC.







Steinberger & Nicklass      Standards Track                    [Page 18]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   o  FrOfferedE

         The number of frames offered by the transmitting device through
         the transmit reference point that were sent in excess of CIR.
         This is represented within the MIB module by one of
         frsldPvcDataFrOfferedE, frsldPvcDataHCFrOfferedE,
         frsldPvcSmplFrOfferedE, or frsldPvcSmplHCFrOfferedE.

   o  DataDeliveredC

         The number of octets received by the receiving device through
         the receive reference point that were delivered within CIR.
         This is represented within the MIB module by one of
         frsldPvcDataDataDeliveredC, frsldPvcDataHCDataDeliveredC,
         frsldPvcSmplDataDeliveredC, or frsldPvcSmplHCDataDeliveredC.

   o  DataDeliveredE

         The number of octets received by the receiving device through
         the receive reference point that were delivered in excess of
         CIR.  This is represented within the MIB module by one of
         frsldPvcDataDataDeliveredE, frsldPvcDataHCDataDeliveredE,
         frsldPvcSmplDataDeliveredE, or frsldPvcSmplHCDataDeliveredE.

   o  DataOfferedC

         The number of octets offered by the transmitting device through
         the transmit reference point that were sent within CIR.  This
         is represented within the MIB module by one of
         frsldPvcDataDataOfferedC, frsldPvcDataHCDataOfferedC,
         frsldPvcSmplDataOfferedC, or frsldPvcSmplHCDataOfferedC.

   o  DataOfferedE

         The number of octets offered by the transmitting device through
         the transmit reference point that were sent in excess of CIR.
         This is represented within the MIB module by one of
         frsldPvcDataDataOfferedE, frsldPvcDataHCDataOfferedE,
         frsldPvcSmplDataOfferedE, or frsldPvcSmplHCDataOfferedE.

   o  UnavailableTime

         The amount of time the PVC was not available during the
         interval of interest.  This is represented within the MIB
         module by either frsldPvcDataUnavailableTime or
         frsldPvcSmplUnavailableTime.





Steinberger & Nicklass      Standards Track                    [Page 19]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   o  Unavailables

         The number of times the PVC was declared to be unavailable
         during the interval of interest.  This is represented within
         the MIB module by either frsldPvcDataUnavailables or
         frsldPvcSmplUnavailables.

3.6.8.  Delay

   The frame transfer delay is defined as the amount of time elapsed, in
   microseconds, from the time a frame exits the source to the time it
   reaches the destination.  The average delay can be found using the
   MIB variable described in DelayAvg above.  The delay may be
   calculated as either round trip or one way, and this information is
   held in the frsldPvcCtrlDelayType MIB variable.  If the delay be
   calculated as round trip, the value of DelayAvg represents the
   average of the total delays of the round trips.  In this case, the
   manager SHOULD divide the value returned by the agent by two to
   obtain the frame transfer delay.  In the case that
   frsldPvcCtrlDelayType is oneWay, the value of DelayAvg represents the
   average of the frame transfer delays and SHOULD be used as is.

3.6.9.  Frame Delivery Ratio

   The frame delivery ratio is defined as the total number of frames
   delivered to the destination divided by the frames offered by the
   source.  The destination values can be obtained using FrDeliveredC
   and FrDeliveredE.  The source values can be obtained using FrOfferedC
   and FrOfferedE.

                          FrDeliveredC + FrDeliveredE
   Frame Delivery Ratio = ---------------------------
                            FrOfferedC + FrOfferedE

                                     FrDeliveredC
   Committed Frame Delivery Ratio =  ------------
                                      FrOfferedC

                                  FrDeliveredE
   Excess Frame Delivery Ratio =  ------------
                                   FrOfferedE










Steinberger & Nicklass      Standards Track                    [Page 20]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


3.6.10.  Data Delivery Ratio

   The data delivery ratio is defined as the total amount of data
   delivered to the destination divided by the data offered by the
   source.  The destination values can be obtained using DataDeliveredC
   and DataDeliveredE.  The source values can be obtained using
   DataOfferedC and DataOfferedE.

                         DataDeliveredC + DataDeliveredE
   Data Delivery Ratio = -------------------------------
                           DataOfferedC + DataOfferedE

                                   DataDeliveredC
   Committed Data Delivery Ratio = --------------
                                    DataOfferedC

                                DataDeliveredE
   Excess Data Delivery Ratio = --------------
                                 DataOfferedE

3.6.11.  Service Availability

   Some forms of service availability measurement defined in FRF.13 [17]
   require knowledge of the amount of time the network is allowed to be
   unavailable during the period of measurement.  This is called the
   excluded outage time and will be represented in the measurements
   below as ExcludedTime.  It is assumed that the management software
   will maintain this information in that it often relates to specific
   times and dates that many devices are not capable of maintaining.
   Further, it may change based on a moving maintenance window that the
   device cannot track well.

   Mean Time to Repair (FRMTTR) = 0 if Unavailables is 0.

                       UnavailableTime
   Otherwise, FRMTTR = ---------------
                        Unavailables


   Virtual Connection Availability (FRVCA) = 0 if IntervalTime equals
                                                  ExcludedTime.

                      IntervalTime - ExcludedTime - UnavailableTime
   Otherwise, FRVCA = --------------------------------------------- *100
                               IntervalTime - ExcludedTime


   Mean Time Between Service Outages (FRMTBSO) = 0 if Unavailables is 0.



Steinberger & Nicklass      Standards Track                    [Page 21]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   Otherwise, FRMTBSO = IntervalTime - ExcludedTime - UnavailableTime
                        ---------------------------------------------
                                       Unavailables

4.  Relation to Other MIB Modules

   There is no explicit relation to any other frame relay MIB module nor
   are any required to implement this MIB module.  However, there is a
   need for knowledge of ifIndexes and some understanding of DLCIs.  The
   ifIndex information can be found in the IF-MIB [21] which is
   required.  The DLCI information can be found in either the Frame
   Relay DTE MIB (RFC 2115) [20] or the Frame Relay Network Services MIB
   (RFC 2954) [18]; however, neither is required.

   Upon setting of frsldPvcCtrlStatus in the frsldPvcCtrlTable to
   active(1) the system can be in one of the following three states:

   (1) The respective DLCI is known and is active.  This corresponds to
       a state in which frPVCEndptRowStatus is active(1) and
       frPVCEndptRcvdSigStatus is either active(2) or none(4) for the
       Frame Relay Network Services MIB (RFC 2954) [18].  For the Frame
       Relay DTE MIB, the same state is shown by frCircuitRowStatus of
       active(1) and  frCircuitState of active(2).

   (2) The respective DLCI has not been created.  This corresponds to a
       state in which the row with either frPVCEndptDLCIIndex or
       frCircuitDlci equal to the respective DLCI does not exist in
       either the frPVCEndptTable or the frCircuitTable respectively.

   (3) The respective DLCI has just been removed.  This corresponds to a
       state in which either frPVCEndptRowStatus is no longer active(1)
       or frPVCEndptRcvdSigStatus is no longer active(2) or none(4) for
       the Frame Relay Network Services MIB (RFC 2954) [18].  For the
       Frame Relay DTE MIB, the same state is shown when either
       frCircuitRowStatus is no longer active(1) or frCircuitState is no
       longer active(2).

   For the first case, the row in the frsldPvcDataTable will be filled.
   If frsldSmplCtrlStatus in the frsldSmplCtrlTable for the respective
   DLCI is also `active' the frsldPvcSampleTable will be filled as well.

   For the second case, the respective rows will not be added to any of
   the data or sample tables and frsldPvcCtrlStatus SHOULD report
   notReady(3).







Steinberger & Nicklass      Standards Track                    [Page 22]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   For the third case, frsldPvcCtrlDeleteOnPurge should direct the
   behavior of the system.  If all tables are purged, this case will be
   equivalent to the second case above.  Otherwise, frsldPvcCtrlStatus
   SHOULD remain active(1).

5.  Structure of the MIB Module

   The FRSLD-MIB consists of the following components:

   o  frsldPvcCtrlTable

   o  frsldSmplCtrlTable

   o  frsldPvcDataTable

   o  frsldPvcSampleTable

   o  frsldCapabilities

   Refer to the compliance statement defined within for a definition of
   what objects MUST be implemented.

5.1.  frsldPvcCtrlTable

   The frsldPvcCtrlTable is the central control table for operations of
   the Frame Relay Service Level Definitions MIB.  It provides variables
   to control the parameters required to calculate the objects in the
   other tables.

   A row in this table MUST exist in order for a row to exist in any
   other table in this MIB module.

5.2.  frsldSmplCtrlTable

   This is an optional table to allow control of sampling of the data in
   the data table.

5.3.  frsldPvcDataTable

   This table contains the calculated data.  It relies on configuration
   from the control table.










Steinberger & Nicklass      Standards Track                    [Page 23]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


5.4.  frsldPvcSampleTable

   This table contains samples of the delivery and availability
   information from the data table as well as delay information
   calculated over the sample period.  It relies on configuration from
   both the control table and the sample control table.

5.5.  frsldCapabilities

   This is a group of objects that define write capabilities of the
   read-create objects in the tables above.

6.  Persistence of Data

   The data in frsldPvcCtrlTable and frsldSmplCtrlTable SHOULD persist
   through power cycles.  Note, however, that the symantics of readiness
   for the rows still applies.  This means that it is possible for a row
   to be reprovisioned as notReady(3) if the underlying DLCI does not
   persist.  The data collected in the other tables SHOULD NOT persist
   through power cycles in that the reference TimeStamp is no longer
   valid.

7.  Object Definitions

FRSLD-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE,
    Counter32, Gauge32, Integer32,
    Counter64, TimeTicks, mib-2             FROM SNMPv2-SMI
    CounterBasedGauge64                     FROM HCNUM-TC
    TEXTUAL-CONVENTION, RowStatus,
    TimeStamp                               FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP         FROM SNMPv2-CONF
    ifIndex                                 FROM IF-MIB
    DLCI                                    FROM FRAME-RELAY-DTE-MIB;

    frsldMIB MODULE-IDENTITY
        LAST-UPDATED "200201030000Z" -- January 3, 2002
        ORGANIZATION "IETF Frame Relay Service MIB Working Group"
        CONTACT-INFO
          "IETF Frame Relay Service MIB (frnetmib) Working Group

           WG Charter:    http://www.ietf.org/html.charters/
                                 frnetmib-charter.html
           WG-email:      frnetmib@sunroof.eng.sun.com
           Subscribe:     frnetmib-request@sunroof.eng.sun.com
           Email Archive: ftp://ftp.ietf.org/ietf-mail-archive/frnetmib



Steinberger & Nicklass      Standards Track                    [Page 24]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


           Chair:      Andy Malis
                       Vivace Networks
           Email:      Andy.Malis@vivacenetworks.com

           WG editor:  Robert Steinberger
                       Paradyne Networks and
                       Fujitsu Network Communications
           Email:      robert.steinberger@fnc.fujitsu.com

           Co-author:  Orly Nicklass
                       RAD Data Communications Ltd.
           EMail:      Orly_n@rad.co.il"
        DESCRIPTION
            "The MIB module to describe generic objects for
             FRF.13 Frame Relay Service Level Definitions."
        REVISION "200201030000Z" -- January 3, 2002
        DESCRIPTION
            "Initial version, published as RFC 3202"
        ::= { mib-2 95 }

    --
    -- Textual Conventions
    --
    FrsldTxRP ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "The reference point a PVC uses for calculation
             of transmitter related statistics.

             The valid values for this type of object are as follows:
               - srcLocalRP(1) for the local source
               - ingTxLocalRP(2) for the local ingress queue input
               - tpTxLocalRP(3) for the local traffic policing
               - eqiTxLocalRP(4) for the local egress queue input
               - eqoTxLocalRP(5) for the local egress queue output
               - otherTxLocalRP(6) for any other local transmit point
               - srcRemoteRP(7) for the remote source
               - ingTxLocalRP(8) for the remote ingress queue input
               - tpTxLocalRP(9) for the remote traffic policing
               - eqiTxRemoteRP(10) for the remote egress queue input
               - eqoTxRemoteRP(11) for the remote egress queue output
               - otherTxRemoteRP(12) for any other remote xmit point"
        REFERENCE
            "FRF.13: Section 2.3"
        SYNTAX      INTEGER {
                      srcLocalRP(1),
                      ingTxLocalRP(2),
                      tpTxLocalRP(3),



Steinberger & Nicklass      Standards Track                    [Page 25]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


                      eqiTxLocalRP(4),
                      eqoTxLocalRP(5),
                      otherTxLocalRP(6),
                      srcRemoteRP(7),
                      ingTxRemoteRP(8),
                      tpTxRemoteRP(9),
                      eqiTxRemoteRP(10),
                      eqoTxRemoteRP(11),
                      otherTxRemoteRP(12)
                    }

    FrsldRxRP ::= TEXTUAL-CONVENTION
        STATUS      current
        DESCRIPTION
            "The reference point a PVC uses for calculation
             of receiver related statistics.

             The valid values for this object are as follows:
               - desLocalRP(1) for the local destination
               - ingRxLocalRP(2) for the local ingress queue input
               - tpRxLocalRP(3) for the local traffic policing
               - eqiRxLocalRP(4) for the local egress queue input
               - eqoRxLocalRP(5) for the local egress queue output
               - otherRxLocalRP(6) for any other local receive point
               - desRemoteRP(7) for the remote destination
               - ingRxRemoteRP(8) for the remote ingress input
               - tpRxRemoteRP(9) for the remote traffic policing
               - eqiRxRemoteRP(10) for the remote egress queue input
               - eqoRxRemoteRP(11) for the remote egress queue output
               - otherRxRemoteRP(12) for any other remote receive point"
        REFERENCE
            "FRF.13: Section 2.3"
        SYNTAX      INTEGER {
                      desLocalRP(1),
                      ingRxLocalRP(2),
                      tpRxLocalRP(3),
                      eqiRxLocalRP(4),
                      eqoRxLocalRP(5),
                      otherRxLocalRP(6),
                      desRemoteRP(7),
                      ingRxRemoteRP(8),
                      tpRxRemoteRP(9),
                      eqiRxRemoteRP(10),
                      eqoRxRemoteRP(11),
                      otherRxRemoteRP(12)
                    }

    --



Steinberger & Nicklass      Standards Track                    [Page 26]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


    -- Base Objects
    ---

    frsldObjects      OBJECT IDENTIFIER ::= { frsldMIB 1 }
    frsldCapabilities OBJECT IDENTIFIER ::= { frsldMIB 2 }
    frsldConformance  OBJECT IDENTIFIER ::= { frsldMIB 3 }

    -- The Frame Relay Service Level Definitions PVC Control Table
    --
    -- This table is used to define and display the parameters of
    -- service level definitions on individual PVCs.

    frsldPvcCtrlTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF FrsldPvcCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The Frame Relay Service Level Definitions
             PVC control table."
        ::= { frsldObjects 1 }

    frsldPvcCtrlEntry OBJECT-TYPE
        SYNTAX      FrsldPvcCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the Frame Relay Service Level
             Definitions PVC control table."
        INDEX    { ifIndex, frsldPvcCtrlDlci,
                   frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP}
        ::= { frsldPvcCtrlTable 1 }

    FrsldPvcCtrlEntry ::=
        SEQUENCE {
            --
            -- Index Control Variables
            --
            frsldPvcCtrlDlci                DLCI,
            frsldPvcCtrlTransmitRP          FrsldTxRP,
            frsldPvcCtrlReceiveRP           FrsldRxRP,
            frsldPvcCtrlStatus              RowStatus,
            --
            -- Service Level Definitions Setup Variables
            --
            frsldPvcCtrlPacketFreq          Integer32,
            --
            -- Delay Specific Setup Variables
            --



Steinberger & Nicklass      Standards Track                    [Page 27]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


            frsldPvcCtrlDelayFrSize         Integer32,
            frsldPvcCtrlDelayType           INTEGER,
            frsldPvcCtrlDelayTimeOut        Integer32,
            --
            -- Data Persistence Control Variables
            --
            frsldPvcCtrlPurge               Integer32,
            frsldPvcCtrlDeleteOnPurge       INTEGER,
            frsldPvcCtrlLastPurgeTime       TimeStamp
        }

    frsldPvcCtrlDlci OBJECT-TYPE
        SYNTAX      DLCI
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The value of this object is equal to the DLCI
             value for this PVC."
        ::= { frsldPvcCtrlEntry 1 }

    frsldPvcCtrlTransmitRP OBJECT-TYPE
        SYNTAX      FrsldTxRP
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The reference point this PVC uses for calculation
             of transmitter related statistics.  This object
             together with frsldPvcCtrlReceiveRP define the
             measurement domain."
        REFERENCE
            "FRF.13: Section 2.3"
        ::= { frsldPvcCtrlEntry 2 }

    frsldPvcCtrlReceiveRP OBJECT-TYPE
        SYNTAX      FrsldRxRP
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The reference point this PVC uses for calculation
             of receiver related statistics.  This object
             together with frsldPvcCtrlTransmitRP define the
             measurement domain."
        ::= { frsldPvcCtrlEntry 3 }

    frsldPvcCtrlStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current



Steinberger & Nicklass      Standards Track                    [Page 28]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        DESCRIPTION
            "The status of the current row.  This object is
             used to add, delete, and disable rows in this
             table.  When the status changes to active(1) for the
             first time, a row will also be added to the data
             table below.  This row SHOULD not be removed until
             the status is changed to deleted.

             When this object is set to destroy(6), all associated
             sample and data table rows will also be deleted.
             When this object is changed from active(1) to any
             other valid value, the defined purge behavior will
             affect the data and sample tables.

             The rows added to this table MUST have a valid
             ifIndex and an ifType related to frame relay.  Further,
             the reference points referred to by frsldPvcCtrlTransmitRP
             and frsldPvcCtrlReceiveRP MUST be supported (see the
             frsldRPCaps object).

             If at any point the row is not in the active(1) state
             and the DLCI no longer exists, the state SHOULD
             report notReady(3).

             The data in this table SHOULD persist through power
             cycles.  The symantics of readiness for the rows still
             applies.  This means that it is possible for a row to be
             reprovisioned as notReady(3) if the underlying DLCI does
             not persist."
        ::= { frsldPvcCtrlEntry 4 }

    frsldPvcCtrlPacketFreq OBJECT-TYPE
        SYNTAX      Integer32 (0..3600)
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The frequency in seconds between initiation of
             specialized packets used to collect delay and / or
             delivery information as supported by the device.
             A value of zero indicates that no packets will
             be sent."
        DEFVAL { 60 }
        ::= { frsldPvcCtrlEntry 5 }

    frsldPvcCtrlDelayFrSize OBJECT-TYPE
        SYNTAX      Integer32 (1..8188)
        UNITS       "octets"



Steinberger & Nicklass      Standards Track                    [Page 29]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The size of the payload in the frame used for
             calculation of network delay."
        DEFVAL { 128 }
        ::= { frsldPvcCtrlEntry 6 }

    frsldPvcCtrlDelayType OBJECT-TYPE
        SYNTAX      INTEGER {
                      oneWay(1),
                      roundTrip(2)
                    }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
                "The type of delay measurement performed."
        REFERENCE
            "FRF.13: Section 3"
        ::= { frsldPvcCtrlEntry 7 }

    frsldPvcCtrlDelayTimeOut OBJECT-TYPE
        SYNTAX      Integer32 (1..3600)
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "A delay frame will count as a missed poll if
             it is not updated in the time specified by
             frsldPvcCtrlDelayTimeOut."
        DEFVAL { 60 }
        ::= { frsldPvcCtrlEntry 8 }

    frsldPvcCtrlPurge OBJECT-TYPE
        SYNTAX      Integer32 (0..172800) -- up to 48 hours
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object defines the amount of time the device
             will wait, after discovering that a DLCI does not exist,
             the DLCI was deleted or the value of frsldPvcCtrlStatus
             changes from active(1) to either notInService(2) or
             notReady(3), prior to automatically purging the history
             in the sample tables and resetting the data in the data
             tables to all zeroes.  If frsldPvcCtrlStatus is manually
             set to destroy(6), this object does not apply."
        DEFVAL { 0 }



Steinberger & Nicklass      Standards Track                    [Page 30]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        ::= { frsldPvcCtrlEntry 9 }

    frsldPvcCtrlDeleteOnPurge OBJECT-TYPE
        SYNTAX      INTEGER {
                      none(1),
                      sampleContols(2),
                      all(3)
                    }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object defines whether rows will
             automatically be deleted from the tables
             when the information is purged.

             - A value of none(1) indicates that no rows
               will deleted.  The last known values will
               be preserved.
             - A value of sampleControls(2) indicates
               that all associated sample control rows
               will be deleted.
             - A value of all(3) indicates that all
               associated rows SHOULD be deleted."
        DEFVAL { all }
        ::= { frsldPvcCtrlEntry 10 }

    frsldPvcCtrlLastPurgeTime OBJECT-TYPE
        SYNTAX      TimeStamp
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object returns the value of sysUpTime
             at the time the information was last purged.
             This value SHOULD be set to the sysUpTime
             upon setting frsldPvcCtrlStatus to active(1)
             for the first time.  Each time a
             discontinuity in the counters occurs, this
             value MUST be set to the sysUpTime.

             If frsldPvcCtrlStatus has never been active(1),
             this object SHOULD return 0.

             This object SHOULD be used as the discontinuity
             timer for the counters in frsldPvcDataTable."
        ::= { frsldPvcCtrlEntry 11 }

    -- The Frame Relay Service Level Definitions Sampling Control
    -- Table



Steinberger & Nicklass      Standards Track                    [Page 31]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


    --
    -- This table is used to define the sample control parameters
    -- of service level definitions on individual PVCs.

    frsldSmplCtrlTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF FrsldSmplCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The Frame Relay Service Level Definitions
             sampling control table."
        ::= { frsldObjects 2 }

    frsldSmplCtrlEntry OBJECT-TYPE
        SYNTAX      FrsldSmplCtrlEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the Frame Relay Service Level
             Definitions sample control table."
        INDEX    { ifIndex, frsldPvcCtrlDlci,
                   frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP,
                   frsldSmplCtrlIdx }
        ::= { frsldSmplCtrlTable 1 }

    FrsldSmplCtrlEntry ::=
        SEQUENCE {
            --
            -- Index Control Variables
            --
            frsldSmplCtrlIdx                Integer32,
            frsldSmplCtrlStatus             RowStatus,
            --
            -- Collection Control Variables
            --
            frsldSmplCtrlColPeriod          Integer32,
            frsldSmplCtrlBuckets            Integer32,
            frsldSmplCtrlBucketsGranted     Integer32
        }

    frsldSmplCtrlIdx OBJECT-TYPE
        SYNTAX  Integer32 (1..256)
        MAX-ACCESS not-accessible
        STATUS  current
        DESCRIPTION
            "The unique index for this row in the
             sample control table."
        ::= { frsldSmplCtrlEntry 1 }



Steinberger & Nicklass      Standards Track                    [Page 32]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


    frsldSmplCtrlStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The status of the current row.  This object is
             used to add, delete, and disable rows in this
             table.  This row SHOULD NOT be removed until the
             status is changed to destroy(6).  When the status
             changes to active(1), the collection in the sample
             tables below will be activated.

             The rows added to this table MUST have a valid
             ifIndex, an ifType related to frame relay,
             frsldPvcCtrlDlci MUST exist for the specified
             ifIndex and frsldPvcCtrlStatus MUST have a
             value of active(1).

             The value of frsldPvcCtrlStatus MUST be active(1)
             to transition this object to active(1).  If
             the value of frsldPvcCtrlStatus becomes anything
             other than active(1) when the state of this object
             is not active(1), this object SHOULD be set to
             notReady(3).

             The data in this table SHOULD persist through power
             cycles.  The symantics of readiness for the rows still
             applies.  This means that it is possible for a row to be
             reprovisioned as notReady(3) if the underlying DLCI does
             not persist."
        ::= { frsldSmplCtrlEntry 2 }

    frsldSmplCtrlColPeriod OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        UNITS       "seconds"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The amount of time in seconds that defines a
             period of collection for the statistics.
             At the end of each period, the statistics will be
             sampled and a row is added to the sample table."
        ::= { frsldSmplCtrlEntry 3 }

    frsldSmplCtrlBuckets OBJECT-TYPE
        SYNTAX      Integer32 (1..65535)
        MAX-ACCESS  read-create
        STATUS      current



Steinberger & Nicklass      Standards Track                    [Page 33]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        DESCRIPTION
            "The number of discrete buckets over which the
             data statistics are sampled.

             When this object is created or modified, the device
             SHOULD attempt to set the frsldSmplCtrlBuckets-
             Granted to a value as close as is possible
             depending upon the implementation and the available
             resources."
        DEFVAL { 60 }
        ::= { frsldSmplCtrlEntry 4 }

    frsldSmplCtrlBucketsGranted OBJECT-TYPE
        SYNTAX      Integer32 (0..65535)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of discrete buckets granted.  This
             object will return 0 until frsldSmplCtrlStatus is
             set to active(1).  At that time the buckets will be
             allocated depending upon implementation and
             available resources."
        ::= { frsldSmplCtrlEntry 5 }

    -- The Frame Relay Service Level Definitions PVC Data Table
    --
    -- This table contains the accumulated values of
    -- the collected data.  This table is the table that should
    -- be referenced by external polling mechanisms if time
    -- based polling be desired.

     frsldPvcDataTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF FrsldPvcDataEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The Frame Relay Service Level Definitions
             data table.

             This table contains accumulated values of the
             collected data.  It is the table that should be
             referenced by external polling mechanisms if
             time based polling be desired."
        ::= { frsldObjects 3 }

    frsldPvcDataEntry OBJECT-TYPE
        SYNTAX      FrsldPvcDataEntry
        MAX-ACCESS  not-accessible



Steinberger & Nicklass      Standards Track                    [Page 34]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        STATUS      current
        DESCRIPTION
            "An entry in the Frame Relay Service Level
             Definitions data table."
        INDEX    { ifIndex, frsldPvcCtrlDlci,
                  frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP}
        ::= { frsldPvcDataTable 1 }

    FrsldPvcDataEntry ::=
        SEQUENCE {
            frsldPvcDataMissedPolls       Counter32,
            frsldPvcDataFrDeliveredC      Counter32,
            frsldPvcDataFrDeliveredE      Counter32,
            frsldPvcDataFrOfferedC        Counter32,
            frsldPvcDataFrOfferedE        Counter32,
            frsldPvcDataDataDeliveredC    Counter32,
            frsldPvcDataDataDeliveredE    Counter32,
            frsldPvcDataDataOfferedC      Counter32,
            frsldPvcDataDataOfferedE      Counter32,
            frsldPvcDataHCFrDeliveredC    Counter64,
            frsldPvcDataHCFrDeliveredE    Counter64,
            frsldPvcDataHCFrOfferedC      Counter64,
            frsldPvcDataHCFrOfferedE      Counter64,
            frsldPvcDataHCDataDeliveredC  Counter64,
            frsldPvcDataHCDataDeliveredE  Counter64,
            frsldPvcDataHCDataOfferedC    Counter64,
            frsldPvcDataHCDataOfferedE    Counter64,
            frsldPvcDataUnavailableTime   TimeTicks,
            frsldPvcDataUnavailables      Counter32
        }

    frsldPvcDataMissedPolls OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The total number of polls that have been determined
             to be missed.  These polls are typically associated
             with the calculation of delay but may also be
             used for the calculation of other statistics.  If an
             anticipated poll is not received in a reasonable
             amount of time, it should be counted as missed.
             The value used to determine the reasonable amount
             of time is contained in frsldPvcCtrlDelayTimeOut.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by



Steinberger & Nicklass      Standards Track                    [Page 35]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             frsldPvcCtrlLastPurgeTime."
        ::= { frsldPvcDataEntry 1 }

    frsldPvcDataFrDeliveredC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliveredc)"
        ::= { frsldPvcDataEntry 2 }

    frsldPvcDataFrDeliveredE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliverede)"
        ::= { frsldPvcDataEntry 3 }

    frsldPvcDataFrOfferedC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by



Steinberger & Nicklass      Standards Track                    [Page 36]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferedc)"
        ::= { frsldPvcDataEntry 4 }

    frsldPvcDataFrOfferedE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferede)"
        ::= { frsldPvcDataEntry 5 }

    frsldPvcDataDataDeliveredC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliveredc)"
        ::= { frsldPvcDataEntry 6 }

    frsldPvcDataDataDeliveredE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.

             Discontinuities in the value of this counter can



Steinberger & Nicklass      Standards Track                    [Page 37]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliverede)"
        ::= { frsldPvcDataEntry 7 }

    frsldPvcDataDataOfferedC OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP within CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferedc)"
        ::= { frsldPvcDataEntry 8 }

    frsldPvcDataDataOfferedE OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferede)"
        ::= { frsldPvcDataEntry 9 }

    frsldPvcDataHCFrDeliveredC OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.  This object is a 64-bit version
             of frsldPvcDataFrDeliveredC.



Steinberger & Nicklass      Standards Track                    [Page 38]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliveredc)"
        ::= { frsldPvcDataEntry 10 }

    frsldPvcDataHCFrDeliveredE OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.  This object is a 64-bit
             version of frsldPvcDataFrDeliveredE.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliverede)"
        ::= { frsldPvcDataEntry 11 }

    frsldPvcDataHCFrOfferedC OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP within CIR.  This object is
             a 64-bit version of frsldPvcDataFrOfferedC.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferedc)"
        ::= { frsldPvcDataEntry 12 }

    frsldPvcDataHCFrOfferedE OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION



Steinberger & Nicklass      Standards Track                    [Page 39]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR.  This
             object is a 64-bit version of frsldPvcDataFrOfferedE.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferede)"
        ::= { frsldPvcDataEntry 13 }

    frsldPvcDataHCDataDeliveredC OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR.  This object is a 64-bit version of
             frsldPvcDataDataDeliveredC.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliveredc)"
        ::= { frsldPvcDataEntry 14 }

    frsldPvcDataHCDataDeliveredE OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR.  This object is a 64-bit
             version of frsldPvcDataDataDeliveredE.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliverede)"
        ::= { frsldPvcDataEntry 15 }




Steinberger & Nicklass      Standards Track                    [Page 40]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


    frsldPvcDataHCDataOfferedC OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP within CIR.  This object is
             a 64-bit version of frsldPvcDataDataOfferedC.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferedc)"
        ::= { frsldPvcDataEntry 16 }

    frsldPvcDataHCDataOfferedE OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR.
             This object is a 64-bit version of
             frsldPvcDataDataOfferedE.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferede)"
        ::= { frsldPvcDataEntry 17 }

    frsldPvcDataUnavailableTime OBJECT-TYPE
        SYNTAX      TimeTicks
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The amount of time this PVC was declared unavailable
             for any reason since this row was created."
        REFERENCE
            "FRF.13: Section 6.1 (OutageTime)"
        ::= { frsldPvcDataEntry 18 }

    frsldPvcDataUnavailables OBJECT-TYPE
        SYNTAX      Counter32



Steinberger & Nicklass      Standards Track                    [Page 41]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of times this PVC was declared unavailable
             for any reason since this row was created.

             Discontinuities in the value of this counter can
             occur at re-initialization of the management system
             and at other times as indicated by
             frsldPvcCtrlLastPurgeTime."
        REFERENCE
            "FRF.13: Section 6.1 (OutageCount)"
        ::= { frsldPvcDataEntry 19 }

    -- The Frame Relay Service Level Definitions PVC Sample Table
    --
    -- This table contains the sampled delay, delivery and
    -- availability information.

    frsldPvcSampleTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF FrsldPvcSampleEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The Frame Relay Service Level Definitions
             sample table."
        ::= { frsldObjects 4 }

    frsldPvcSampleEntry OBJECT-TYPE
        SYNTAX      FrsldPvcSampleEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in the Frame Relay Service Level
             Definitions data sample table."
        INDEX    { ifIndex, frsldPvcCtrlDlci,
                   frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP,
                   frsldSmplCtrlIdx, frsldPvcSmplIdx }
        ::= { frsldPvcSampleTable 1 }

    FrsldPvcSampleEntry ::=
        SEQUENCE {
            frsldPvcSmplIdx              Integer32,
            frsldPvcSmplDelayMin         Gauge32,
            frsldPvcSmplDelayMax         Gauge32,
            frsldPvcSmplDelayAvg         Gauge32,
            frsldPvcSmplMissedPolls      Gauge32,
            frsldPvcSmplFrDeliveredC     Gauge32,



Steinberger & Nicklass      Standards Track                    [Page 42]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


            frsldPvcSmplFrDeliveredE     Gauge32,
            frsldPvcSmplFrOfferedC       Gauge32,
            frsldPvcSmplFrOfferedE       Gauge32,
            frsldPvcSmplDataDeliveredC   Gauge32,
            frsldPvcSmplDataDeliveredE   Gauge32,
            frsldPvcSmplDataOfferedC     Gauge32,
            frsldPvcSmplDataOfferedE     Gauge32,
            frsldPvcSmplHCFrDeliveredC   CounterBasedGauge64,
            frsldPvcSmplHCFrDeliveredE   CounterBasedGauge64,
            frsldPvcSmplHCFrOfferedC     CounterBasedGauge64,
            frsldPvcSmplHCFrOfferedE     CounterBasedGauge64,
            frsldPvcSmplHCDataDeliveredC CounterBasedGauge64,
            frsldPvcSmplHCDataDeliveredE CounterBasedGauge64,
            frsldPvcSmplHCDataOfferedC   CounterBasedGauge64,
            frsldPvcSmplHCDataOfferedE   CounterBasedGauge64,
            frsldPvcSmplUnavailableTime  TimeTicks,
            frsldPvcSmplUnavailables     Gauge32,
            frsldPvcSmplStartTime        TimeStamp,
            frsldPvcSmplEndTime          TimeStamp
        }

    frsldPvcSmplIdx OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The bucket index of the current sample.  This
             increments once for each new bucket in the
             table."
        ::= { frsldPvcSampleEntry 1 }

    frsldPvcSmplDelayMin OBJECT-TYPE
        SYNTAX      Gauge32
        UNITS       "microseconds"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The minimum delay reported in microseconds measured
             for any information packet that arrived during this
             interval.

             A value of zero means that no data is available."
        REFERENCE
            "FRF.13: Section 3.1 (FTD)"
        ::= { frsldPvcSampleEntry 2 }

    frsldPvcSmplDelayMax OBJECT-TYPE
        SYNTAX      Gauge32



Steinberger & Nicklass      Standards Track                    [Page 43]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        UNITS       "microseconds"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The largest delay reported in microseconds measured
             for any information packet that arrived during this
             interval.

             A value of zero means that no data is available."
        REFERENCE
            "FRF.13: Section 3.1 (FTD)"
        ::= { frsldPvcSampleEntry 3 }

    frsldPvcSmplDelayAvg OBJECT-TYPE
        SYNTAX      Gauge32
        UNITS       "microseconds"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The average delay reported in microseconds measured
             for all delay packets that arrived during this
             interval.

             A value of zero means that no data is available."
        REFERENCE
            "FRF.13: Section 3.1 (FTD)"
        ::= { frsldPvcSampleEntry 4 }

    frsldPvcSmplMissedPolls OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The total number of polls that were missed during
             this interval."
        ::= { frsldPvcSampleEntry 5 }

    frsldPvcSmplFrDeliveredC OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR during this interval.

             If it is the case that the high capacity counters
             are also used, this MUST report the value of the



Steinberger & Nicklass      Standards Track                    [Page 44]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCFrDeliveredC."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliveredc)"
        ::= { frsldPvcSampleEntry 6 }

    frsldPvcSmplFrDeliveredE OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR during this interval.

             If it is the case that the high capacity counters
             are also used, this MUST report the value of the
             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCFrDeliveredE."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliverede))"
        ::= { frsldPvcSampleEntry 7 }

    frsldPvcSmplFrOfferedC OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP within CIR during this
             interval.

             If it is the case that the high capacity counters
             are also used, this MUST report the value of the
             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCFrOfferedC."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferedc)"
        ::= { frsldPvcSampleEntry 8 }

    frsldPvcSmplFrOfferedE OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR
             during this interval.



Steinberger & Nicklass      Standards Track                    [Page 45]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             If it is the case that the high capacity counters
             are also used, this MUST report the value of the
             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCFrOfferedE."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferede)"
        ::= { frsldPvcSampleEntry 9 }

    frsldPvcSmplDataDeliveredC OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR during this interval.

             If it is the case that the high capacity counters
             are also used, this MUST report the value of the
             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCDataDeliveredC."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliveredc)"
        ::= { frsldPvcSampleEntry 10 }

    frsldPvcSmplDataDeliveredE OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlDeliveredRP and determined to have been
             sent in excess of the CIR during this interval.

             If it is the case that the high capacity counters
             are also used, this MUST report the value of the
             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCDataDeliveredE."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliverede)"
        ::= { frsldPvcSampleEntry 11 }

    frsldPvcSmplDataOfferedC OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through



Steinberger & Nicklass      Standards Track                    [Page 46]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             frsldPvcCtrlTransmitRP within CIR during this
             interval.

             If it is the case that the high capacity counters
             are also used, this MUST report the value of the
             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCDataOfferredC."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferedc)"
        ::= { frsldPvcSampleEntry 12 }

    frsldPvcSmplDataOfferedE OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR
             during this interval.

             If it is the case that the high capacity counters
             are also used, this MUST report the value of the
             lower 32 bits of the CounterBasedGauge64 value of
             frsldPvcSmplHCDataOfferedE."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferede)"
        ::= { frsldPvcSampleEntry 13 }

    frsldPvcSmplHCFrDeliveredC OBJECT-TYPE
        SYNTAX      CounterBasedGauge64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR during this interval.  This object
             is a 64-bit version of frsldPvcSmplFrDeliveredC."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliveredc)"
        ::= { frsldPvcSampleEntry 14 }

    frsldPvcSmplHCFrDeliveredE OBJECT-TYPE
        SYNTAX      CounterBasedGauge64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were received at
             frsldPvcCtrlReceiveRP and determined to have been



Steinberger & Nicklass      Standards Track                    [Page 47]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


             sent in excess of the CIR during this interval.
             This object is a 64-bit version of frsldPvcSmpl-
             FrDeliveredE."
        REFERENCE
            "FRF.13: Section 4.1 (FramesDeliverede)"
       ::= { frsldPvcSampleEntry 15 }

    frsldPvcSmplHCFrOfferedC OBJECT-TYPE
        SYNTAX      CounterBasedGauge64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP within CIR during this
             interval.  This object is a 64-bit version of
             frsldPvcSmplFrOfferedC."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferedc)"
        ::= { frsldPvcSampleEntry 16 }

    frsldPvcSmplHCFrOfferedE OBJECT-TYPE
        SYNTAX      CounterBasedGauge64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of frames that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR
             during this interval.  This object is a 64-bit
             version of frsldPvcSmplFrOfferedE."
        REFERENCE
            "FRF.13: Section 4.1 (FramesOfferede)"
        ::= { frsldPvcSampleEntry 17 }

    frsldPvcSmplHCDataDeliveredC OBJECT-TYPE
        SYNTAX      CounterBasedGauge64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent within CIR during this interval.  This value
             is a 64-bit version of frsldPvcSmplDataDeliveredC."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliveredc)"
        ::= { frsldPvcSampleEntry 18 }

    frsldPvcSmplHCDataDeliveredE OBJECT-TYPE
        SYNTAX      CounterBasedGauge64



Steinberger & Nicklass      Standards Track                    [Page 48]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were received at
             frsldPvcCtrlReceiveRP and determined to have been
             sent in excess of the CIR during this interval.  This
             value is a 64-bit version of frsldPvcSmplData-
             DeliveredE."
        REFERENCE
            "FRF.13: Section 5.1 (DataDeliverede)"
        ::= { frsldPvcSampleEntry 19 }

    frsldPvcSmplHCDataOfferedC OBJECT-TYPE
        SYNTAX      CounterBasedGauge64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP within CIR during this
             interval.  This value is a 64-bit version of
             frsldPvcSmplDataOfferedC."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferedc)"
        ::= { frsldPvcSampleEntry 20 }

    frsldPvcSmplHCDataOfferedE OBJECT-TYPE
        SYNTAX      CounterBasedGauge64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of octets that were offered through
             frsldPvcCtrlTransmitRP in excess of the CIR
             during this interval.  This object is a 64-bit
             version of frsldPvcSmplDataOfferedE."
        REFERENCE
            "FRF.13: Section 5.1 (DataOfferede)"
        ::= { frsldPvcSampleEntry 21 }

    frsldPvcSmplUnavailableTime OBJECT-TYPE
        SYNTAX  TimeTicks
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "The amount of time this PVC was declared
             unavailable for any reason during this interval."
        REFERENCE
            "FRF.13: Section 6.1 (OutageTime)"
        ::= { frsldPvcSampleEntry 22 }



Steinberger & Nicklass      Standards Track                    [Page 49]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


    frsldPvcSmplUnavailables OBJECT-TYPE
        SYNTAX  Gauge32
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "The number of times this PVC was declared
             unavailable for any reason during this interval."
        REFERENCE
            "FRF.13: Section 6.1 (OutageCount)"
        ::= { frsldPvcSampleEntry 23 }

    frsldPvcSmplStartTime OBJECT-TYPE
        SYNTAX      TimeStamp
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The value of sysUpTime when this sample interval
             started."
        ::= { frsldPvcSampleEntry 24 }

    frsldPvcSmplEndTime OBJECT-TYPE
        SYNTAX      TimeStamp
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The value of sysUpTime when this sample interval
             ended.  No data will be reported and the row will
             not appear in the table until the sample has
             been collected."
        ::= { frsldPvcSampleEntry 25 }

    -- Capabilities Group
    -- This group provides capabilities objects for the tables
    -- that control configuration.

    frsldPvcCtrlWriteCaps OBJECT-TYPE
        SYNTAX  BITS {
               frsldPvcCtrlStatus(0),
               frsldPvcCtrlPacketFreq(1),
               frsldPvcCtrlDelayFrSize(2),
               frsldPvcCtrlDelayType(3),
               frsldPvcCtrlDelayTimeOut(4),
               frsldPvcCtrlPurge(5),
               frsldPvcCtrlDeleteOnPurge(6)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION



Steinberger & Nicklass      Standards Track                    [Page 50]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


            "This object specifies the write capabilities
             for the read-create objects of the PVC Control
             table.  If the corresponding bit is enabled (1),
             the agent supports writes to that object."
        ::= { frsldCapabilities 1 }

    frsldSmplCtrlWriteCaps OBJECT-TYPE
        SYNTAX  BITS {
               frsldSmplCtrlStatus(0),
               frsldSmplCtrlBuckets(1)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "This object specifies the write capabilities
             for the read-create objects of the Sample Control
             table.  If the corresponding bit is enabled (1),
             the agent supports writes to that object."
        ::= { frsldCapabilities 2 }

    frsldRPCaps OBJECT-TYPE
        SYNTAX  BITS {
               srcLocalRP(0),
               ingTxLocalRP(1),
               tpTxLocalRP(2),
               eqiTxLocalRP(3),
               eqoTxLocalRP(4),
               otherTxLocalRP(5),
               srcRemoteRP(6),
               ingTxRemoteRP(7),
               tpTxRemoteRP(8),
               eqiTxRemoteRP(9),
               eqoTxRemoteRP(10),
               otherTxRemoteRP(11),
               desLocalRP(12),
               ingRxLocalRP(13),
               tpRxLocalRP(14),
               eqiRxLocalRP(15),
               eqoRxLocalRP(16),
               otherRxLocalRP(17),
               desRemoteRP(18),
               ingRxRemoteRP(19),
               tpRxRemoteRP(20),
               eqiRxRemoteRP(21),
               eqoRxRemoteRP(22),
               otherRxRemoteRP(23)
        }
        MAX-ACCESS  read-only



Steinberger & Nicklass      Standards Track                    [Page 51]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


        STATUS  current
        DESCRIPTION
            "This object specifies the reference points that
             the agent supports.  This object allows the management
             application to discover which rows can be created on
             a specific device."
        ::= { frsldCapabilities 3 }

    frsldMaxPvcCtrls   OBJECT-TYPE
        SYNTAX      Integer32 (0..2147483647)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum number of control rows that can be created
             in frsldPvcCtrlTable.  Sets to this object lower than
             the current value of frsldNumPvcCtrls should result in
             inconsistentValue."
        ::= { frsldCapabilities 4 }

    frsldNumPvcCtrls   OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current number of rows in frsldPvcCtrlTable."
        ::= { frsldCapabilities 5 }


    frsldMaxSmplCtrls   OBJECT-TYPE
        SYNTAX      Integer32 (0..2147483647)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum number of control rows that can be created
             in frsldSmplCtrlTable.  Sets to this object lower than
             the current value of frsldNumSmplCtrls should result in
             inconsistentValue."
        ::= { frsldCapabilities 6 }

    frsldNumSmplCtrls   OBJECT-TYPE
        SYNTAX      Gauge32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The current number of rows in frsldSmplCtrlTable."
        ::= { frsldCapabilities 7 }

    -- Conformance Information



Steinberger & Nicklass      Standards Track                    [Page 52]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


    frsldMIBGroups      OBJECT IDENTIFIER ::= { frsldConformance 1 }
    frsldMIBCompliances OBJECT IDENTIFIER ::= { frsldConformance 2 }

    --
    -- Compliance Statements
    --

    frsldCompliance MODULE-COMPLIANCE
        STATUS  current
        DESCRIPTION
            "The compliance statement for SNMP entities
             which support with Frame Relay Service Level
             Definitions.  This group defines the minimum
             level of support required for compliance."
        MODULE -- this module
            MANDATORY-GROUPS { frsldPvcReqCtrlGroup,
                               frsldPvcReqDataGroup,
                               frsldCapabilitiesGroup}

            GROUP       frsldPvcHCFrameDataGroup
            DESCRIPTION
               "This group is mandatory only for those network
                interfaces with corresponding instance of ifSpeed
                 greater than 650,000,000 bits/second."

            GROUP       frsldPvcHCOctetDataGroup
            DESCRIPTION
               "This group is mandatory only for those network
                interfaces with corresponding instance of ifSpeed
                greater than 650,000,000 bits/second."

            GROUP       frsldPvcPacketGroup
            DESCRIPTION
               "This group is optional.  Network interfaces that
                allow control of the packets used to collect
                information are encouraged to implement this
                group."

            GROUP       frsldPvcDelayCtrlGroup
            DESCRIPTION
               "This group is optional.  Network interfaces that
                offer control of the delay measurement are
                strongly encouraged to implement this group."


            GROUP       frsldPvcSampleCtrlGroup
            DESCRIPTION
               "This group is mandatory only for those network



Steinberger & Nicklass      Standards Track                    [Page 53]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


                interfaces that allow data sampling."

            GROUP       frsldPvcDelayDataGroup
            DESCRIPTION
               "This group is only mandatory when
                frsldPvcDelayCtrlGroup is implemented.  It is
                strongly encouraged that any device capable
                of measuring delay implement this group."

            GROUP       frsldPvcSampleDelayGroup
            DESCRIPTION
               "This group is only mandatory when both
                frsldPvcSampleCtrlGroup and frsldPvcDelayDataGroup
                are supported."

            GROUP       frsldPvcSampleDataGroup
            DESCRIPTION
               "This group is mandatory whenever
                frsldPvcSampleCtrlGroup is supported."

            GROUP       frsldPvcSampleHCFrameGroup
            DESCRIPTION
               "This group is mandatory whenever both
                frsldPvcSampleCtrlGroup and frsldPvcHCFrameDataGroup
                are supported."

            GROUP       frsldPvcSampleHCDataGroup
            DESCRIPTION
               "This group is mandatory whenever both
                frsldPvcSampleCtrlGroup and frsldPvcHCOctetDataGroup
                are supported."

            GROUP       frsldPvcSampleAvailGroup
            DESCRIPTION
               "This group is mandatory whenever
                frsldPvcSampleCtrlGroup is supported."

            GROUP       frsldPvcSampleGeneralGroup
            DESCRIPTION
               "This group is mandatory whenever
                frsldPvcSampleCtrlGroup is supported."

            OBJECT      frsldPvcCtrlStatus
            SYNTAX      RowStatus { active(1) } -- subset of RowStatus
            MIN-ACCESS  read-only
            DESCRIPTION
               "Row creation can be done outside of the scope of
                the SNMP protocol.  If this object is implemented



Steinberger & Nicklass      Standards Track                    [Page 54]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


                with max-access of read-only, then the only value
                that MUST be returned is active(1) and
                frsldPvcCtrlWriteCaps MUST return 0 for the
                frsldPvcCtrlStatus(0) bit."

            OBJECT      frsldPvcCtrlPurge
            MIN-ACCESS  read-only
            DESCRIPTION
                "Write access is not required.  If this object is
                 implemented with a max-access of read-only, then
                 the frsldPvcCtrlPurge(5) bit must return 0."

            OBJECT      frsldPvcCtrlDeleteOnPurge
            MIN-ACCESS  read-only
            DESCRIPTION
                "Write access is not required.  If this object is
                 implemented with a max-access of read-only, then
                 the frsldPvcCtrlDeleteOnPurge(6) bit must return
                 0."

            OBJECT      frsldMaxPvcCtrls
            MIN-ACCESS  read-only
            DESCRIPTION
                "Write access is not required if the device either
                 dynamically allocates memory or statically allocates
                 a fixed number of entries.  In the case of static
                 allocation, the device should always report the
                 correct maximum number of controls.  In the case
                 of dynamic allocation, the device SHOULD always
                 report a number greater than frsldNumPvcCtrls
                 when allocation is possible and a number equal to
                 frsldNumPvcCtrls when allocation is not possible."
            OBJECT      frsldMaxSmplCtrls
            MIN-ACCESS  read-only
            DESCRIPTION
                "Write access is not required if the device either
                 dynamically allocates memory or statically allocates
                 a fixed number of entries.  In the case of static
                 allocation, the device should always report the
                 correct maximum number of controls.  In the case
                 of dynamic allocation, the device SHOULD always
                 report a number greater than frsldNumSmplCtrls
                 when allocation is possible and a number equal to
                 frsldNumSmplCtrls when allocation is not possible."

    ::= { frsldMIBCompliances 1 }

    --



Steinberger & Nicklass      Standards Track                    [Page 55]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


    -- Units of Conformance
    --
    frsldPvcReqCtrlGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcCtrlStatus,
            frsldPvcCtrlPurge,
            frsldPvcCtrlDeleteOnPurge,
            frsldPvcCtrlLastPurgeTime
       }
       STATUS  current
       DESCRIPTION
           "A collection of required objects providing
            control information applicable to a PVC which
            implements Service Level Definitions."
       ::= { frsldMIBGroups 1 }

    frsldPvcPacketGroup OBJECT-GROUP
       OBJECTS {
            frsldPvcCtrlPacketFreq
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing packet
            level control information applicable to a PVC which
            implements Service Level Definitions."
       ::= { frsldMIBGroups 2 }

    frsldPvcDelayCtrlGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcCtrlDelayFrSize,
            frsldPvcCtrlDelayType,
            frsldPvcCtrlDelayTimeOut
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing delay
            control information applicable to a PVC which
            implements Service Level Definitions.

            If this group is implemented, frsldPvcPacketGroup
            and frsldPvcDelayDataGroup MUST also be implemented."
       ::= { frsldMIBGroups 3 }

    frsldPvcSampleCtrlGroup  OBJECT-GROUP
       OBJECTS {
            frsldSmplCtrlStatus,
            frsldSmplCtrlColPeriod,
            frsldSmplCtrlBuckets,



Steinberger & Nicklass      Standards Track                    [Page 56]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


            frsldSmplCtrlBucketsGranted
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing sample
            control information applicable to a PVC which
            implements Service Level Definitions.

            If this group is implemented, frsldPvcReqDataGroup
            and frsldPvcSampleGeneralGroup MUST also be
            implemented."
       ::= { frsldMIBGroups 4 }

    frsldPvcReqDataGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcDataFrDeliveredC,
            frsldPvcDataFrDeliveredE,
            frsldPvcDataFrOfferedC,
            frsldPvcDataFrOfferedE,
            frsldPvcDataDataDeliveredC,
            frsldPvcDataDataDeliveredE,
            frsldPvcDataDataOfferedC,
            frsldPvcDataDataOfferedE,
            frsldPvcDataUnavailableTime,
            frsldPvcDataUnavailables
       }
       STATUS  current
       DESCRIPTION
           "A collection of required objects providing data
            collected on a PVC which implements Service
            Level Definitions."
       ::= { frsldMIBGroups 5 }

    frsldPvcDelayDataGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcDataMissedPolls
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing delay
            data collected on a PVC which implements Service
            Level Definitions.

            If this group is implemented, frsldPvcDelayCtrlGroup
            MUST also be implemented."
       ::= { frsldMIBGroups 6 }

    frsldPvcHCFrameDataGroup  OBJECT-GROUP



Steinberger & Nicklass      Standards Track                    [Page 57]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


       OBJECTS {
            frsldPvcDataHCFrDeliveredC,
            frsldPvcDataHCFrDeliveredE,
            frsldPvcDataHCFrOfferedC,
            frsldPvcDataHCFrOfferedE
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing high
            capacity frame data collected on a PVC which
            implements Service Level Definitions."
       ::= { frsldMIBGroups 7 }

    frsldPvcHCOctetDataGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcDataHCDataDeliveredC,
            frsldPvcDataHCDataDeliveredE,
            frsldPvcDataHCDataOfferedC,
            frsldPvcDataHCDataOfferedE
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing high
            capacity octet data collected on a PVC which
            implements Service Level Definitions."
       ::= { frsldMIBGroups 8 }

    frsldPvcSampleDelayGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcSmplDelayMin,
            frsldPvcSmplDelayMax,
            frsldPvcSmplDelayAvg,
            frsldPvcSmplMissedPolls
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing delay
            sample data collected on a PVC which implements
            Service Level Definitions.

            If this group is implemented, frsldPvcDelayCtrlGroup
            MUST also be implemented."
       ::= { frsldMIBGroups 9 }

    frsldPvcSampleDataGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcSmplFrDeliveredC,
            frsldPvcSmplFrDeliveredE,



Steinberger & Nicklass      Standards Track                    [Page 58]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


            frsldPvcSmplFrOfferedC,
            frsldPvcSmplFrOfferedE,
            frsldPvcSmplDataDeliveredC,
            frsldPvcSmplDataDeliveredE,
            frsldPvcSmplDataOfferedC,
            frsldPvcSmplDataOfferedE
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing data
            and frame delivery sample data collected on a PVC
            which implements Service Level Definitions.

            If this group is implemented, frsldPvcReqDataGroup
            MUST also be implemented."
       ::= { frsldMIBGroups 10 }

    frsldPvcSampleHCFrameGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcSmplHCFrDeliveredC,
            frsldPvcSmplHCFrDeliveredE,
            frsldPvcSmplHCFrOfferedC,
            frsldPvcSmplHCFrOfferedE
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing high
            capacity frame delivery sample data collected on a PVC
            which implements Service Level Definitions.

            If this group is implemented, frsldPvcHCFrameDataGroup
            MUST also be implemented."
       ::= { frsldMIBGroups 11 }

    frsldPvcSampleHCDataGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcSmplHCDataDeliveredC,
            frsldPvcSmplHCDataDeliveredE,
            frsldPvcSmplHCDataOfferedC,
            frsldPvcSmplHCDataOfferedE
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing high
            capacity data delivery sample data collected on a PVC
            which implements Service Level Definitions.

            If this group is implemented, frsldPvcHCOctetDataGroup



Steinberger & Nicklass      Standards Track                    [Page 59]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


            MUST also be implemented."
       ::= { frsldMIBGroups 12 }

    frsldPvcSampleAvailGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcSmplUnavailableTime,
            frsldPvcSmplUnavailables
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing
            availability sample data collected on a PVC which
            implements Service Level Definitions.

            If this group is implemented, frsldPvcReqDataGroup
            MUST also be implemented."
       ::= { frsldMIBGroups 13 }

    frsldPvcSampleGeneralGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcSmplStartTime,
            frsldPvcSmplEndTime
       }
       STATUS  current
       DESCRIPTION
           "A collection of optional objects providing
            general sample data collected on a PVC which
            implements Service Level Definitions."
       ::= { frsldMIBGroups 14 }

    frsldCapabilitiesGroup  OBJECT-GROUP
       OBJECTS {
            frsldPvcCtrlWriteCaps,
            frsldSmplCtrlWriteCaps,
            frsldRPCaps,
            frsldMaxPvcCtrls,
            frsldNumPvcCtrls,
            frsldMaxSmplCtrls,
            frsldNumSmplCtrls
       }
       STATUS  current
       DESCRIPTION
           "A collection of required objects providing
            capability information and control for this
            MIB module."
       ::= { frsldMIBGroups 15 }
END




Steinberger & Nicklass      Standards Track                    [Page 60]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


8.  Acknowledgments

   This document was produced by the Frame Relay Service MIB Working
   Group.  It is based on the Frame Relay Forum's implementation
   agreement on service level definitions, FRF.13 [17].

   The editors would like to thank the following people for their
   helpful comments:

   o  Ken Rehbehn, Visual Networks

   o  Santa Dasu, Quick Eagle Networks

9.  References

   [1]  Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for
        Describing SNMP Management Frameworks", RFC 2571, April 1999.

   [2]  Rose, M. and K. McCloghrie, "Structure and Identification of
        Management Information for TCP/IP-based Internets", STD 16, RFC
        1155, May 1990.

   [3]  Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
        RFC 1212, March 1991.

   [4]  Rose, M., "A Convention for Defining Traps for use with the
        SNMP", RFC 1215, March 1991.

   [5]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Structure of Management Information
        Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.

   [6]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58,
        RFC 2579, April 1999.

   [7]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
        M. and S. Waldbusser, "Conformance Statements for SMIv2", STD
        58, RFC 2580, April 1999.

   [8]  Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
        Network Management Protocol", STD 15, RFC 1157, May 1990.









Steinberger & Nicklass      Standards Track                    [Page 61]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


   [9]  Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
        "Introduction to Community-based SNMPv2", RFC 1901, January
        1996.

   [10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport
        Mappings for Version 2 of the Simple Network Management Protocol
        (SNMPv2)", RFC 1906, January 1996.

   [11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
        Processing and Dispatching for the Simple Network Management
        Protocol (SNMP)", RFC 2572, April 1999.

   [12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
        for version 3 of the Simple Network Management Protocol
        (SNMPv3)", RFC 2574, April 1999.

   [13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
        Operations for Version 2 of the Simple Network Management
        Protocol (SNMPv2)", RFC 1905, January 1996.

   [14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC
        2573, April 1999.

   [15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
        Control Model (VACM) for the Simple Network Management Protocol
        (SNMP)", RFC 2575, April 1999.

   [16] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
        to Version 3 of the Internet-standard Network Management
        Framework", RFC 2570, April 1999.

   [17] Frame Relay Forum Technical Committee, "Service Level
        Definitions Implementations Agreement", FRF.13, August 1998.

   [18] Rehbehn, K. and D. Fowler, "Definitions of Managed Objects for
        Frame Relay Service", RFC 2954, October 2000.

   [19] Waldbusser, S., "Remote Network Monitoring Management
        Information Base Version 2 using SMIv2", RFC 2021, January 1997.

   [20] Brown, C. and F. Baker, "Management Information Base for Frame
        Relay DTEs Using SMIv2", RFC 2115, September 1997.

   [21] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",
        RFC 2863, June 2000.

   [22] Bradner, S., "Key words for use in RFCs to Indicate Requirement
        Levels", BCP 14, RFC 2119, March 1997.



Steinberger & Nicklass      Standards Track                    [Page 62]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


10.  Security Considerations

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write and/or read-create.  Such
   objects may be considered sensitive or vulnerable in some network
   environments.  The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.

   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), even then, there is no
   control as to who on the secure network is allowed to access and
   GET/SET (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementers consider the security
   features as provided by the SNMPv3 framework.  Specifically, the use
   of the User-based Security Model RFC 2574 [12] and the View-based
   Access Control Model RFC 2575 [15] is recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to the objects only to those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.

11.  Authors' Addresses

   Robert Steinberger
   Fujitsu Network Communications
   2801 Telecom Parkway
   Richardson, TX 75082

   Phone: 1-972-479-4739
   EMail: robert.steinberger@fnc.fujitsu.com


   Orly Nicklass, Ph.D
   RAD Data Communications Ltd.
   12 Hanechoshet Street
   Tel Aviv, Israel 69710

   Phone: 972 3 7659969
   EMail: Orly_n@rad.co.il








Steinberger & Nicklass      Standards Track                    [Page 63]

RFC 3202           Frame Relay Service Level Defs MIB       January 2002


12.  Full Copyright Statement

   Copyright (C) The Internet Society (2002).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.



















Steinberger & Nicklass      Standards Track                    [Page 64]