💾 Archived View for gemini.bortzmeyer.org › rfc-mirror › rfc2981.txt captured on 2022-06-04 at 03:08:28.

View Raw

More Information

⬅️ Previous capture (2021-11-30)

-=-=-=-=-=-=-







Network Working Group                                      R. Kavasseri
Request for Comments: 2981                     (Editor of this version)
Category: Standards Track                                    B. Stewart
                                           (Author of previous version)
                                                    Cisco Systems, Inc.
                                                           October 2000


                               Event MIB

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it describes managed objects that can be used to
   manage and monitor MIB objects and take action through events.

   The Event MIB provides the ability to monitor MIB objects on the
   local system or on a remote system and take simple action when a
   trigger condition is met.

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119.

Table of Contents

   1 The SNMP Management Framework ...............................    2
   2 Overview ....................................................    3
   3 Relationship to Other MIBs ..................................    3
   4 MIB Sections ................................................    4
   5 Operation ...................................................    5
   6 Security ....................................................    7
   7 Definitions .................................................    7
   8 Intellectual Property .......................................   47
   9 Acknowledgements ............................................   47



Kavasseri & Stewart         Standards Track                     [Page 1]

RFC 2981                       Event MIB                    October 2000


   10 References .................................................   47
   11 Security Considerations ....................................   49
   12 Author's Address ...........................................   49
   13 Editor's Address ...........................................   49
   14 Full Copyright Statement ...................................   50

1.  The SNMP Management Framework

   The SNMP Management Framework presently consists of five major
   components:

    o   An overall architecture, described in RFC 2571 [RFC2571].

    o   Mechanisms for describing and naming objects and events for the
        purpose of management.  The first version of this Structure of
        Management Information (SMI) is called SMIv1 and described in
        STD 16, RFC 1155 [RFC1155], STD 16, RFC 1212 [RFC1212] and RFC
        1215 [RFC1215].  The second version, called SMIv2, is described
        in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and
        STD 58, RFC 2580 [RFC2580].

    o   Message protocols for transferring management information.  The
        first version of the SNMP message protocol is called SNMPv1 and
        described in STD 15, RFC 1157 [RFC1157].  A second version of
        the SNMP message protocol, which is not an Internet standards
        track protocol, is called SNMPv2c and described in RFC 1901
        [RFC1901] and RFC 1906 [RFC1906].  The third version of the
        message protocol is called SNMPv3 and described in RFC 1906
        [RFC1906], RFC 2572 [RFC2572] and RFC 2574 [RFC2574].

    o   Protocol operations for accessing management information.  The
        first set of protocol operations and associated PDU formats is
        described in STD 15, RFC 1157 [RFC1157].  A second set of
        protocol operations and associated PDU formats is described in
        RFC 1905 [RFC1905].

    o   A set of fundamental applications described in RFC 2573
        [RFC2573] and the view-based access control mechanism described
        in RFC 2575 [RFC2575].

   A more detailed introduction to the current SNMP Management Framework
   can be found in RFC 2570 [RFC2570].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the mechanisms defined in the SMI.





Kavasseri & Stewart         Standards Track                     [Page 2]

RFC 2981                       Event MIB                    October 2000


   This memo specifies a MIB module that is compliant to the SMIv2.  A
   MIB conforming to the SMIv1 can be produced through the appropriate
   translations.  The resulting translated MIB must be semantically
   equivalent, except where objects or events are omitted because no
   translation is possible (use of Counter64).  Some machine readable
   information in SMIv2 will be converted into textual descriptions in
   SMIv1 during the translation process.  However, this loss of machine
   readable information is not considered to change the semantics of the
   MIB.  It may not be possible to meaningfully monitor Counter64
   objects using an SMIv1 version of the MIB.

2.  Overview

   With network sizes well beyond the ability of people to manage them
   directly, automated, distributed management is vital.  An important
   aspect of such management is the ability of a system to monitor
   itself or for some other system to monitor it.

   The Event MIB provides the ability to monitor MIB objects on the
   local system or on a remote system and take simple action when a
   trigger condition is met.

   The MIB is intended to suit either a relatively powerful manager or
   mid- level manager, as well as a somewhat more limited self-managing
   system.

3.  Relationship to Other MIBs

   The Event MIB is based on extensive experience with the RMON MIB
   [RFC1757] and provides a superset of the capabilities of the RMON
   alarm and event groups.  Conceptually, the key extension is the
   ability to allow alarms to be generated for MIB objects that are on
   another network element.  The Event MIB calls "triggers" what the
   RMON MIB called "alarms," but the concepts are the same.  Event MIB
   triggers maintain the RMON handling of thresholds and add the concept
   of booleans.  Event MIB events maintain the RMON concept of sending
   an SNMP notification in response to a trigger and add the concept of
   setting a MIB object.

   The Event MIB is the successor and update to SNMPv2's Manager-to-
   Manager MIB [RFC1451] which was declared Historic pending this work.

   The Event MIB depends on the services of the SNMPv3 Management Target
   and Notification MIBs [RFC2573].

   The Event MIB is nicely complemented by the Distributed Management
   Expression MIB [RFC2982], which is the expected source of boolean
   objects to monitor.  Note that there is considerable overlap between



Kavasseri & Stewart         Standards Track                     [Page 3]

RFC 2981                       Event MIB                    October 2000


   the wildcard and delta sample capabilities of the Event and
   Expression MIBs.  A carefully-planned implementation might well use
   common code to provide the overlapping functions.

4.  MIB Sections

   The MIB has four sections: triggers, objects, events, and
   notifications.  Triggers define the conditions that lead to events.
   Events may cause notifications.

   The trigger table lists what objects are to be monitored and how and
   relates each trigger to an event.  It has supplementary, companion
   tables for additional objects that depend on the type of test done
   for the trigger.

   The objects table lists objects that can be added to notifications
   based on the trigger, the trigger test type, or the event that
   resulted in the notification.

   The event table defines what happens when an event is triggered:
   sending a notification, setting a MIB object or both.  It has
   supplementary, companion tables for additional objects that depend on
   the action taken.

   The notification section defines a set of generic notifications to go
   with the events and for Event MIB error handling, and it defines a
   set of objects to put in those notifications.

   The following diagram describes the relationships between the tables
   in the Event MIB.





















Kavasseri & Stewart         Standards Track                     [Page 4]

RFC 2981                       Event MIB                    October 2000


   +-----------------------------+
   | mteTriggerEntry             |      subclassed by:
   |  { mteOwner,                |---+
   |    IMPLIED mteTriggerName } |   +-- mteTriggerDeltaEntry
   |                             |   |
   |                             |   +-- mteTriggerExistenceEntry
   |                             |   |
   |                             |   +-- mteTriggerBooleanEntry
   |                             |   |
   |                             |   +-- mteTriggerThresholdEntry
   |                             |
   |       mteTrigger*Event -------------------------------->+
   |                             |                           |
   |       mteTriggerObjects ------------------>+            |
   +-----------------------------+              |            |
                                                |            |
   +-----------------------------+              V            |
   | mteObjectsEntry             |              |            |
   |  { mteOwner,                |<-------------+            |
   |    mteObjectsName,          |                           |
   |    mteObjectsIndex }        |                           |
   +-----------------------------+                           |
                                                             V
   +---------------------------+                             |
   | mteEventEntry             |<----------------------------+
   |  { mteOwner,              |
   |    IMPLIED mteEventName } |
   |                           |
   |            mteEventAction---> + (condition)
   +---------------------------+   |
                                   V
   +---------------------------+   |   +---------------------------+
   | mteEventNotificationEntry |   |   | mteEventSetEntry          |
   |  { mteOwner,              |<--+-->|  { mteOwner,              |
   |    IMPLIED mteEventName } |       |    IMPLIED mteEventName } |
   +---------------------------+       +---------------------------+

5.  Operation

   The Event MIB is instrumentation for a distributed management
   application that monitors MIB objects.  In its simplest form this
   application monitors individual, local MIB objects, just as an RMON
   probe fulfills the functions implied by RMON's alarm and event
   operation.  Additionally the application can monitor remote objects
   and wildcarded groups of objects.






Kavasseri & Stewart         Standards Track                     [Page 5]

RFC 2981                       Event MIB                    October 2000


   Remote monitoring uses the tag service of the Management Target MIB
   [RFC2573] to select and access remote systems as an ordinary SNMP-
   based management application.  Local monitoring may be via a more
   intimate, local interface which may, for example, bypass SNMP
   encoding but otherwise is functionally identical to remote SNMP
   operation, including the application of access control.  A self-
   management only system MAY not implement remote monitoring.

   Wildcards indicate that the application SHOULD use a GetNext-type
   operation to find the zero or more instances implied by a truncated
   object identifier, just like an ordinary SNMP-based management
   application.  Each instance of a wildcard is treated as if it were a
   separate entry, that is the instances of a wildcarded object are
   independent of one another.  For example, a wild-carded object may
   trigger an event, and result in the setting of another wildcarded
   object.  The instance that satisfied the trigger function is used to
   perform the set function.  All of this takes place independently of
   any additional instances that may fill the wildcard.

   Error handling is by notification.  These error notifications SHOULD
   be enabled only for the diagnosis of problems indicated by error
   counters.  If minimizing the probability of notification loss is a
   concern they SHOULD be transmitted as Inform PDUs as described in the
   [SNMP-TARGET-MIB] or directed to a log as described in the
   Notification Log MIB [rfcNotificationLogMIB].  Note that this does
   not mean the Notification Log MIB is REQUIRED, since in fact
   notifications usually are not lost, but that the Notification Log MIB
   can be helpful with this as well as other MIBs that include
   notifications.

   Although like most MIBs this one has no explicit controls for the
   persistence of the values set in configuring events, a robust, polite
   implementation would certainly not force its managing applications to
   reconfigure it whenever it resets.

   Again, as with most MIBs, it is implementation-specific how a system
   provides and manages such persistence.  To speculate, one could
   imagine, for example, that persistence depended on the context in
   which the expression was configured, or perhaps system-specific
   characteristics of the expression's owner.  Or perhaps everything in
   a MIB such as this one, which is clearly aimed at persistent
   configuration, is automatically part of a system's other persistent
   configuration.








Kavasseri & Stewart         Standards Track                     [Page 6]

RFC 2981                       Event MIB                    October 2000


6.  Security

   Security of Event MIB entries depends on SNMPv3 access control for
   the entire MIB or for subsets based on entry owner names.

   Security of monitored objects for remote access depends on the
   Management Target MIB [RFC2573].  Security for local access can
   depend on the Management Target MIB or on recording appropriate
   security credentials of the creator of an entry and using those to
   access the local objects.  These security credentials are the
   parameters necessary as inputs to isAccessAllowed from the
   Architecture for Describing SNMP Management Frameworks.  When
   accessing local objects without using a local target tag, the system
   MUST (conceptually) use isAccessAllowed to ensure that it does not
   violate security.

   To facilitate the provisioning of access control by a security
   administrator for this MIB itself using the View-Based Access Control
   Model (VACM) defined in RFC 2275 [RFC2575] for tables in which
   multiple users may need to independently create or modify entries,
   the initial index is used as an "owner index".  Such an initial index
   has a syntax of SnmpAdminString, and can thus be trivially mapped to
   a securityName or groupName as defined in VACM, in accordance with a
   security policy.

   If a security administrator were to employ such an approach, all
   entries in related tables belonging to a particular user will have
   the same value for this initial index.  For a given user's entries in
   a particular table, the object identifiers for the information in
   these entries will have the same sub-identifiers (except for the
   "column" sub-identifier) up to the end of the encoded owner index.
   To configure VACM to permit access to this portion of the table, one
   would create vacmViewTreeFamilyTable entries with the value of
   vacmViewTreeFamilySubtree including the owner index portion, and
   vacmViewTreeFamilyMask "wildcarding" the column sub-identifier.  More
   elaborate configurations are possible.

7.  Definitions

DISMAN-EVENT-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE,
    Integer32, Unsigned32,
    NOTIFICATION-TYPE, Counter32,
    Gauge32, mib-2, zeroDotZero         FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, RowStatus,
    TruthValue                FROM SNMPv2-TC



Kavasseri & Stewart         Standards Track                     [Page 7]

RFC 2981                       Event MIB                    October 2000


    MODULE-COMPLIANCE, OBJECT-GROUP,
    NOTIFICATION-GROUP             FROM SNMPv2-CONF
    sysUpTime                 FROM SNMPv2-MIB
    SnmpTagValue              FROM SNMP-TARGET-MIB
    SnmpAdminString           FROM SNMP-FRAMEWORK-MIB;

dismanEventMIB MODULE-IDENTITY
    LAST-UPDATED "200010160000Z"            -- 16 October 2000
    ORGANIZATION "IETF Distributed Management Working Group"
    CONTACT-INFO "Ramanathan Kavasseri
                  Cisco Systems, Inc.
                  170 West Tasman Drive,
                  San Jose CA 95134-1706.
                  Phone: +1 408 526 4527
                  Email: ramk@cisco.com"
    DESCRIPTION
     "The MIB module for defining event triggers and actions
     for network management purposes."
-- Revision History

       REVISION     "200010160000Z"            -- 16 October 2000
       DESCRIPTION  "This is the initial version of this MIB.
                    Published as RFC 2981"
    ::= { mib-2 88 }

dismanEventMIBObjects OBJECT IDENTIFIER ::= { dismanEventMIB 1 }

-- Management Triggered Event (MTE) objects

mteResource           OBJECT IDENTIFIER ::= { dismanEventMIBObjects 1 }
mteTrigger            OBJECT IDENTIFIER ::= { dismanEventMIBObjects 2 }
mteObjects            OBJECT IDENTIFIER ::= { dismanEventMIBObjects 3 }
mteEvent              OBJECT IDENTIFIER ::= { dismanEventMIBObjects 4 }

--
-- Textual Conventions
--

FailureReason ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Reasons for failures in an attempt to perform a management
        request.

        The first group of errors, numbered less than 0, are related
        to problems in sending the request.  The existence of a
        particular error code here does not imply that all
        implementations are capable of sensing that error and



Kavasseri & Stewart         Standards Track                     [Page 8]

RFC 2981                       Event MIB                    October 2000


        returning that code.

        The second group, numbered greater than 0, are copied
        directly from SNMP protocol operations and are intended to
        carry exactly the meanings defined for the protocol as returned
        in an SNMP response.

        localResourceLack       some local resource such as memory
                                lacking or
                                mteResourceSampleInstanceMaximum
                                exceeded
        badDestination          unrecognized domain name or otherwise
                                invalid destination address
        destinationUnreachable  can't get to destination address
        noResponse              no response to SNMP request
        badType                 the data syntax of a retrieved object
                                as not as expected
        sampleOverrun           another sample attempt occurred before
                                the previous one completed"

    SYNTAX      INTEGER { localResourceLack(-1),
                          badDestination(-2),
                          destinationUnreachable(-3),
                          noResponse(-4),
                          badType(-5),
                          sampleOverrun(-6),

                          noError(0),

                          tooBig(1),
                          noSuchName(2),
                          badValue(3),
                          readOnly(4),
                          genErr(5),
                          noAccess(6),
                          wrongType(7),
                          wrongLength(8),
                          wrongEncoding(9),
                          wrongValue(10),
                          noCreation(11),
                          inconsistentValue(12),
                          resourceUnavailable(13),
                          commitFailed(14),
                          undoFailed(15),
                          authorizationError(16),
                          notWritable(17),
                          inconsistentName(18) }
--



Kavasseri & Stewart         Standards Track                     [Page 9]

RFC 2981                       Event MIB                    October 2000


-- Resource Control Section
--

mteResourceSampleMinimum OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    UNITS       "seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The minimum mteTriggerFrequency this system will
        accept.  A system may use the larger values of this minimum to
        lessen the impact of constant sampling.  For larger
        sampling intervals the system samples less often and
        suffers less overhead.  This object provides a way to enforce
        such lower overhead for all triggers created after it is
        set.

        Unless explicitly resource limited, a system's value for
        this object SHOULD be 1, allowing as small as a 1 second
        interval for ongoing trigger sampling.

        Changing this value will not invalidate an existing setting
        of mteTriggerFrequency."
    ::= { mteResource 1 }

mteResourceSampleInstanceMaximum OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "instances"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The maximum number of instance entries this system will
        support for sampling.

        These are the entries that maintain state, one for each
        instance of each sampled object as selected by
        mteTriggerValueID.  Note that wildcarded objects result
        in multiple instances of this state.

        A value of 0 indicates no preset limit, that is, the limit
        is dynamic based on system operation and resources.

        Unless explicitly resource limited, a system's value for
        this object SHOULD be 0.

        Changing this value will not eliminate or inhibit existing
        sample state but could prevent allocation of additional state
        information."



Kavasseri & Stewart         Standards Track                    [Page 10]

RFC 2981                       Event MIB                    October 2000


    ::= { mteResource 2 }

mteResourceSampleInstances OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "instances"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of currently active instance entries as
        defined for mteResourceSampleInstanceMaximum."
    ::= { mteResource 3 }

mteResourceSampleInstancesHigh OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "instances"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The highest value of mteResourceSampleInstances that has
        occurred since initialization of the management system."
    ::= { mteResource 4 }

mteResourceSampleInstanceLacks OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "instances"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of times this system could not take a new sample
        because that allocation would have exceeded the limit set by
        mteResourceSampleInstanceMaximum."
    ::= { mteResource 5 }

--
-- Trigger Section
--

-- Counters

mteTriggerFailures OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "failures"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of times an attempt to check for a trigger
        condition has failed.  This counts individually for each
        attempt in a group of targets or each attempt for a



Kavasseri & Stewart         Standards Track                    [Page 11]

RFC 2981                       Event MIB                    October 2000


        wildcarded object."
    ::= { mteTrigger 1 }

--
-- Trigger Table
--

mteTriggerTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteTriggerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of management event trigger information."
    ::= { mteTrigger 2 }

mteTriggerEntry OBJECT-TYPE
    SYNTAX      MteTriggerEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a single trigger.  Applications create and
        delete entries using mteTriggerEntryStatus."
    INDEX       { mteOwner, IMPLIED mteTriggerName }
    ::= { mteTriggerTable 1 }

MteTriggerEntry ::= SEQUENCE {
    mteOwner                            SnmpAdminString,
    mteTriggerName                      SnmpAdminString,
    mteTriggerComment                   SnmpAdminString,
    mteTriggerTest                      BITS,
    mteTriggerSampleType                INTEGER,
    mteTriggerValueID                   OBJECT IDENTIFIER,
    mteTriggerValueIDWildcard           TruthValue,
    mteTriggerTargetTag                 SnmpTagValue,
    mteTriggerContextName               SnmpAdminString,
    mteTriggerContextNameWildcard       TruthValue,
    mteTriggerFrequency                 Unsigned32,
    mteTriggerObjectsOwner              SnmpAdminString,
    mteTriggerObjects                   SnmpAdminString,
    mteTriggerEnabled                   TruthValue,
    mteTriggerEntryStatus               RowStatus
}

mteOwner OBJECT-TYPE
   SYNTAX      SnmpAdminString (SIZE(0..32))
   MAX-ACCESS  not-accessible
   STATUS      current
   DESCRIPTION



Kavasseri & Stewart         Standards Track                    [Page 12]

RFC 2981                       Event MIB                    October 2000


        "The owner of this entry. The exact semantics of this
        string are subject to the security policy defined by the
        security administrator."
    ::= { mteTriggerEntry 1 }

mteTriggerName OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (1..32))
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A locally-unique, administratively assigned name for the
        trigger within the scope of mteOwner."
    ::= { mteTriggerEntry 2 }

mteTriggerComment OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "A description of the trigger's function and use."
    DEFVAL { ''H }
    ::= { mteTriggerEntry 3 }

mteTriggerTest OBJECT-TYPE
    SYNTAX      BITS { existence(0), boolean(1), threshold(2) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The type of trigger test to perform.  For 'boolean' and
        'threshold'  tests, the object at mteTriggerValueID MUST
        evaluate to an integer, that is, anything that ends up encoded
        for transmission (that is, in BER, not ASN.1) as an integer.

        For 'existence', the specific test is as selected by
        mteTriggerExistenceTest.  When an object appears, vanishes
        or changes value, the trigger fires. If the object's
        appearance caused the trigger firing, the object MUST
        vanish before the trigger can be fired again for it, and
        vice versa. If the trigger fired due to a change in the
        object's value, it will be fired again on every successive
        value change for that object.

        For 'boolean', the specific test is as selected by
        mteTriggerBooleanTest.  If the test result is true the trigger
        fires.  The trigger will not fire again until the value has
        become false and come back to true.

        For 'threshold' the test works as described below for



Kavasseri & Stewart         Standards Track                    [Page 13]

RFC 2981                       Event MIB                    October 2000


        mteTriggerThresholdStartup, mteTriggerThresholdRising, and
        mteTriggerThresholdFalling.

        Note that combining 'boolean' and 'threshold' tests on the
        same object may be somewhat redundant."
    DEFVAL { { boolean } }
    ::= { mteTriggerEntry 4 }

mteTriggerSampleType OBJECT-TYPE
    SYNTAX      INTEGER { absoluteValue(1), deltaValue(2) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The type of sampling to perform.

        An 'absoluteValue' sample requires only a single sample to be
        meaningful, and is exactly the value of the object at
        mteTriggerValueID at the sample time.

        A 'deltaValue' requires two samples to be meaningful and is
        thus not available for testing until the second and subsequent
        samples after the object at mteTriggerValueID is first found
        to exist.  It is the difference between the two samples.  For
        unsigned values it is always positive, based on unsigned
        arithmetic.  For signed values it can be positive or negative.

        For SNMP counters to be meaningful they should be sampled as a
        'deltaValue'.

        For 'deltaValue' mteTriggerDeltaTable contains further
        parameters.

        If only 'existence' is set in mteTriggerTest this object has
        no meaning."
    DEFVAL { absoluteValue }
    ::= { mteTriggerEntry 5 }

mteTriggerValueID OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The object identifier of the MIB object to sample to see
        if the trigger should fire.

        This may be wildcarded by truncating all or part of the
        instance portion, in which case the value is obtained
        as if with a GetNext function, checking multiple values



Kavasseri & Stewart         Standards Track                    [Page 14]

RFC 2981                       Event MIB                    October 2000


        if they exist.  If such wildcarding is applied,
        mteTriggerValueIDWildcard must be 'true' and if not it must
        be 'false'.

        Bad object identifiers or a mismatch between truncating the
        identifier and the value of mteTriggerValueIDWildcard result
        in operation as one would expect when providing the wrong
        identifier to a Get or GetNext operation.  The Get will fail
        or get the wrong object.  The GetNext will indeed get whatever
        is next, proceeding until it runs past the initial part of the
        identifier and perhaps many unintended objects for confusing
        results.  If the value syntax of those objects is not usable,
        that results in a 'badType' error that terminates the scan.

        Each instance that fills the wildcard is independent of any
        additional instances, that is, wildcarded objects operate
        as if there were a separate table entry for each instance
        that fills the wildcard without having to actually predict
        all possible instances ahead of time."
    DEFVAL { zeroDotZero }
    ::= { mteTriggerEntry 6 }

mteTriggerValueIDWildcard OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Control for whether mteTriggerValueID is to be treated as
        fully-specified or wildcarded, with 'true' indicating wildcard."
    DEFVAL { false }
    ::= { mteTriggerEntry 7 }

mteTriggerTargetTag OBJECT-TYPE
    SYNTAX      SnmpTagValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The tag for the target(s) from which to obtain the condition
        for a trigger check.

        A length of 0 indicates the local system.  In this case,
        access to the objects indicated by mteTriggerValueID is under
        the security credentials of the requester that set
        mteTriggerEntryStatus to 'active'.  Those credentials are the
        input parameters for isAccessAllowed from the Architecture for
        Describing SNMP Management Frameworks.

        Otherwise access rights are checked according to the security



Kavasseri & Stewart         Standards Track                    [Page 15]

RFC 2981                       Event MIB                    October 2000


        parameters resulting from the tag."
    DEFVAL { ''H }
    ::= { mteTriggerEntry 8 }

mteTriggerContextName OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The management context from which to obtain mteTriggerValueID.

        This may be wildcarded by leaving characters off the end.  For
        example use 'Repeater' to wildcard to 'Repeater1',
        'Repeater2', 'Repeater-999.87b', and so on.  To indicate such
        wildcarding is intended, mteTriggerContextNameWildcard must
        be 'true'.

        Each instance that fills the wildcard is independent of any
        additional instances, that is, wildcarded objects operate
        as if there were a separate table entry for each instance
        that fills the wildcard without having to actually predict
        all possible instances ahead of time.

        Operation of this feature assumes that the local system has a
        list of available contexts against which to apply the
        wildcard.  If the objects are being read from the local
        system, this is clearly the system's own list of contexts.
        For a remote system a local version of such a list is not
        defined by any current standard and may not be available, so
        this function MAY not be supported."
    DEFVAL { ''H }
    ::= { mteTriggerEntry 9 }

mteTriggerContextNameWildcard OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Control for whether mteTriggerContextName is to be treated as
        fully-specified or wildcarded, with 'true' indicating wildcard."
    DEFVAL { false }
    ::= { mteTriggerEntry 10 }

mteTriggerFrequency OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current



Kavasseri & Stewart         Standards Track                    [Page 16]

RFC 2981                       Event MIB                    October 2000


    DESCRIPTION
        "The number of seconds to wait between trigger samples.  To
        encourage consistency in sampling, the interval is measured
        from the beginning of one check to the beginning of the next
        and the timer is restarted immediately when it expires, not
        when the check completes.

        If the next sample begins before the previous one completed the
        system may either attempt to make the check or treat this as an
        error condition with the error 'sampleOverrun'.

        A frequency of 0 indicates instantaneous recognition of the
        condition.  This is not possible in many cases, but may
        be supported in cases where it makes sense and the system is
        able to do so.  This feature allows the MIB to be used in
        implementations where such interrupt-driven behavior is
        possible and is not likely to be supported for all MIB objects
        even then since such sampling generally has to be tightly
        integrated into low-level code.

        Systems that can support this SHOULD document those cases
        where it can be used.  In cases where it can not, setting this
        object to 0 should be disallowed."
    DEFVAL { 600 }
    ::= { mteTriggerEntry 11 }

mteTriggerObjectsOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerObjects, the mteOwner of a group of
        objects from mteObjectsTable."
    DEFVAL { ''H }
    ::= { mteTriggerEntry 12 }

mteTriggerObjects OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The mteObjectsName of a group of objects from
        mteObjectsTable.  These objects are to be added to any
        Notification resulting from the firing of this trigger.

        A list of objects may also be added based on the event or on
        the value of mteTriggerTest.




Kavasseri & Stewart         Standards Track                    [Page 17]

RFC 2981                       Event MIB                    October 2000


        A length of 0 indicates no additional objects."
    DEFVAL { ''H }
    ::= { mteTriggerEntry 13 }

mteTriggerEnabled OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "A control to allow a trigger to be configured but not used.
        When the value is 'false' the trigger is not sampled."
    DEFVAL { false }
    ::= { mteTriggerEntry 14 }

mteTriggerEntryStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The control that allows creation and deletion of entries.
        Once made active an entry may not be modified except to
        delete it."
    ::= { mteTriggerEntry 15 }

--
-- Trigger Delta Table
--

mteTriggerDeltaTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteTriggerDeltaEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of management event trigger information for delta
        sampling."
    ::= { mteTrigger 3 }

mteTriggerDeltaEntry OBJECT-TYPE
    SYNTAX      MteTriggerDeltaEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a single trigger's delta sampling.  Entries
        automatically exist in this this table for each mteTriggerEntry
        that has mteTriggerSampleType set to 'deltaValue'."
    INDEX       { mteOwner, IMPLIED mteTriggerName }
    ::= { mteTriggerDeltaTable 1 }




Kavasseri & Stewart         Standards Track                    [Page 18]

RFC 2981                       Event MIB                    October 2000


MteTriggerDeltaEntry ::= SEQUENCE {
    mteTriggerDeltaDiscontinuityID                OBJECT IDENTIFIER,
    mteTriggerDeltaDiscontinuityIDWildcard        TruthValue,
    mteTriggerDeltaDiscontinuityIDType            INTEGER
}

sysUpTimeInstance OBJECT IDENTIFIER ::= { sysUpTime 0 }

mteTriggerDeltaDiscontinuityID OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The OBJECT IDENTIFIER (OID) of a TimeTicks, TimeStamp, or
        DateAndTime object that indicates a discontinuity in the value
        at mteTriggerValueID.

        The OID may be for a leaf object (e.g. sysUpTime.0) or may
        be wildcarded to match mteTriggerValueID.

        This object supports normal checking for a discontinuity in a
        counter.  Note that if this object does not point to sysUpTime
        discontinuity checking MUST still check sysUpTime for an overall
        discontinuity.

        If the object identified is not accessible the sample attempt
        is in error, with the error code as from an SNMP request.

        Bad object identifiers or a mismatch between truncating the
        identifier and the value of mteDeltaDiscontinuityIDWildcard
        result in operation as one would expect when providing the
        wrong identifier to a Get operation.  The Get will fail or get
        the wrong object.  If the value syntax of those objects is not
        usable, that results in an error that terminates the sample
        with a 'badType' error code."
    DEFVAL { sysUpTimeInstance }
    ::= { mteTriggerDeltaEntry 1 }

mteTriggerDeltaDiscontinuityIDWildcard OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
        "Control for whether mteTriggerDeltaDiscontinuityID is to be
        treated as fully-specified or wildcarded, with 'true'
        indicating wildcard. Note that the value of this object will
        be the same as that of the corresponding instance of
        mteTriggerValueIDWildcard when the corresponding



Kavasseri & Stewart         Standards Track                    [Page 19]

RFC 2981                       Event MIB                    October 2000


        mteTriggerSampleType is 'deltaValue'."
    DEFVAL { false }
    ::= { mteTriggerDeltaEntry 2 }

mteTriggerDeltaDiscontinuityIDType OBJECT-TYPE
    SYNTAX      INTEGER { timeTicks(1), timeStamp(2), dateAndTime(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value 'timeTicks' indicates the
        mteTriggerDeltaDiscontinuityID of this row is of syntax
        TimeTicks.  The value 'timeStamp' indicates syntax TimeStamp.
        The value 'dateAndTime' indicates syntax DateAndTime."
    DEFVAL { timeTicks }
    ::= { mteTriggerDeltaEntry 3 }

--
-- Trigger Existence Table
--

mteTriggerExistenceTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteTriggerExistenceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of management event trigger information for existence
        triggers."
    ::= { mteTrigger 4 }

mteTriggerExistenceEntry OBJECT-TYPE
    SYNTAX      MteTriggerExistenceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a single existence trigger.  Entries
        automatically exist in this this table for each mteTriggerEntry
        that has 'existence' set in mteTriggerTest."
    INDEX       { mteOwner, IMPLIED mteTriggerName }
    ::= { mteTriggerExistenceTable 1 }

MteTriggerExistenceEntry ::= SEQUENCE {
    mteTriggerExistenceTest              BITS,
    mteTriggerExistenceStartup           BITS,
    mteTriggerExistenceObjectsOwner      SnmpAdminString,
    mteTriggerExistenceObjects           SnmpAdminString,
    mteTriggerExistenceEventOwner        SnmpAdminString,
    mteTriggerExistenceEvent             SnmpAdminString
}



Kavasseri & Stewart         Standards Track                    [Page 20]

RFC 2981                       Event MIB                    October 2000


mteTriggerExistenceTest OBJECT-TYPE
    SYNTAX      BITS { present(0), absent(1), changed(2) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The type of existence test to perform.  The trigger fires
        when the object at mteTriggerValueID is seen to go from
        present to absent, from absent to present, or to have it's
        value changed, depending on which tests are selected:

        present(0) - when this test is selected, the trigger fires
        when the mteTriggerValueID object goes from absent to present.

        absent(1)  - when this test is selected, the trigger fires
        when the mteTriggerValueID object goes from present to absent.
        changed(2) - when this test is selected, the trigger fires
        the mteTriggerValueID object value changes.

        Once the trigger has fired for either presence or absence it
        will not fire again for that state until the object has been
        to the other state. "
    DEFVAL { { present, absent } }
    ::= { mteTriggerExistenceEntry 1 }

mteTriggerExistenceStartup OBJECT-TYPE
    SYNTAX      BITS { present(0), absent(1) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Control for whether an event may be triggered when this entry
        is first set to 'active' and the test specified by
        mteTriggerExistenceTest is true.  Setting an option causes
        that trigger to fire when its test is true."
    DEFVAL { { present, absent } }
    ::= { mteTriggerExistenceEntry 2 }

mteTriggerExistenceObjectsOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerExistenceObjects, the mteOwner of a
        group of objects from mteObjectsTable."
    DEFVAL { ''H }
    ::= { mteTriggerExistenceEntry 3 }

mteTriggerExistenceObjects OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))



Kavasseri & Stewart         Standards Track                    [Page 21]

RFC 2981                       Event MIB                    October 2000


    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteObjectsName of a group of objects from
        mteObjectsTable.  These objects are to be added to any
        Notification resulting from the firing of this trigger for
        this test.

        A list of objects may also be added based on the overall
        trigger, the event or other settings in mteTriggerTest.

        A length of 0 indicates no additional objects."
    DEFVAL { ''H }
    ::= { mteTriggerExistenceEntry 4 }

mteTriggerExistenceEventOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerExistenceEvent, the mteOwner of an event
        entry from the mteEventTable."
    DEFVAL { ''H }
    ::= { mteTriggerExistenceEntry 5 }

mteTriggerExistenceEvent OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteEventName of the event to invoke when mteTriggerType is
        'existence' and this trigger fires.  A length of 0 indicates no
        event."
    DEFVAL { ''H }
    ::= { mteTriggerExistenceEntry 6 }

--
-- Trigger Boolean Table
--

mteTriggerBooleanTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteTriggerBooleanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of management event trigger information for boolean
        triggers."
    ::= { mteTrigger 5 }



Kavasseri & Stewart         Standards Track                    [Page 22]

RFC 2981                       Event MIB                    October 2000


mteTriggerBooleanEntry OBJECT-TYPE
    SYNTAX      MteTriggerBooleanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a single boolean trigger.  Entries
        automatically exist in this this table for each mteTriggerEntry
        that has 'boolean' set in mteTriggerTest."
    INDEX       { mteOwner, IMPLIED mteTriggerName }
    ::= { mteTriggerBooleanTable 1 }

MteTriggerBooleanEntry ::= SEQUENCE {
    mteTriggerBooleanComparison          INTEGER,
    mteTriggerBooleanValue               Integer32,
    mteTriggerBooleanStartup             TruthValue,
    mteTriggerBooleanObjectsOwner        SnmpAdminString,
    mteTriggerBooleanObjects             SnmpAdminString,
    mteTriggerBooleanEventOwner          SnmpAdminString,
    mteTriggerBooleanEvent               SnmpAdminString
}

mteTriggerBooleanComparison OBJECT-TYPE
    SYNTAX      INTEGER { unequal(1), equal(2),
                 less(3), lessOrEqual(4),
                 greater(5), greaterOrEqual(6) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The type of boolean comparison to perform.

        The value at mteTriggerValueID is compared to
        mteTriggerBooleanValue, so for example if
        mteTriggerBooleanComparison is 'less' the result would be true
        if the value at mteTriggerValueID is less than the value of
        mteTriggerBooleanValue."
    DEFVAL { unequal }
    ::= { mteTriggerBooleanEntry 1 }

mteTriggerBooleanValue OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value to use for the test specified by
        mteTriggerBooleanTest."
    DEFVAL { 0 }
    ::= { mteTriggerBooleanEntry 2 }




Kavasseri & Stewart         Standards Track                    [Page 23]

RFC 2981                       Event MIB                    October 2000


mteTriggerBooleanStartup OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Control for whether an event may be triggered when this entry
        is first set to 'active' or a new instance of the object at
        mteTriggerValueID is found and the test specified by
        mteTriggerBooleanComparison is true.  In that case an event is
        triggered if mteTriggerBooleanStartup is 'true'."
    DEFVAL { true }
    ::= { mteTriggerBooleanEntry 3 }

mteTriggerBooleanObjectsOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerBooleanObjects, the mteOwner of a group
        of objects from mteObjectsTable."
    DEFVAL { ''H }
    ::= { mteTriggerBooleanEntry 4 }

mteTriggerBooleanObjects OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteObjectsName of a group of objects from
        mteObjectsTable.  These objects are to be added to any
        Notification resulting from the firing of this trigger for
        this test.

        A list of objects may also be added based on the overall
        trigger, the event or other settings in mteTriggerTest.

        A length of 0 indicates no additional objects."
    DEFVAL { ''H }
    ::= { mteTriggerBooleanEntry 5 }

mteTriggerBooleanEventOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerBooleanEvent, the mteOwner of an event
        entry from mteEventTable."
    DEFVAL { ''H }



Kavasseri & Stewart         Standards Track                    [Page 24]

RFC 2981                       Event MIB                    October 2000


    ::= { mteTriggerBooleanEntry 6 }

mteTriggerBooleanEvent OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteEventName of the event to invoke when mteTriggerType is
        'boolean' and this trigger fires.  A length of 0 indicates no
        event."
    DEFVAL { ''H }
    ::= { mteTriggerBooleanEntry 7 }

--
-- Trigger Threshold Table
--

mteTriggerThresholdTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteTriggerThresholdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of management event trigger information for threshold
        triggers."
    ::= { mteTrigger 6 }

mteTriggerThresholdEntry OBJECT-TYPE
    SYNTAX      MteTriggerThresholdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a single threshold trigger.  Entries
        automatically exist in this table for each mteTriggerEntry
        that has 'threshold' set in mteTriggerTest."
    INDEX       { mteOwner, IMPLIED mteTriggerName }
    ::= { mteTriggerThresholdTable 1 }

MteTriggerThresholdEntry ::= SEQUENCE {
    mteTriggerThresholdStartup                  INTEGER,
    mteTriggerThresholdRising                   Integer32,
    mteTriggerThresholdFalling                  Integer32,
    mteTriggerThresholdDeltaRising              Integer32,
    mteTriggerThresholdDeltaFalling             Integer32,
    mteTriggerThresholdObjectsOwner             SnmpAdminString,
    mteTriggerThresholdObjects                  SnmpAdminString,
    mteTriggerThresholdRisingEventOwner         SnmpAdminString,
    mteTriggerThresholdRisingEvent              SnmpAdminString,
    mteTriggerThresholdFallingEventOwner        SnmpAdminString,



Kavasseri & Stewart         Standards Track                    [Page 25]

RFC 2981                       Event MIB                    October 2000


    mteTriggerThresholdFallingEvent             SnmpAdminString,
    mteTriggerThresholdDeltaRisingEventOwner    SnmpAdminString,
    mteTriggerThresholdDeltaRisingEvent         SnmpAdminString,
    mteTriggerThresholdDeltaFallingEventOwner   SnmpAdminString,
    mteTriggerThresholdDeltaFallingEvent        SnmpAdminString
}

mteTriggerThresholdStartup OBJECT-TYPE
    SYNTAX      INTEGER { rising(1), falling(2), risingOrFalling(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The event that may be triggered when this entry is first
        set to 'active' and a new instance of the object at
        mteTriggerValueID is found.  If the first sample after this
        instance becomes active is greater than or equal to
        mteTriggerThresholdRising and mteTriggerThresholdStartup is
        equal to 'rising' or 'risingOrFalling', then one
        mteTriggerThresholdRisingEvent is triggered for that instance.
        If the first sample after this entry becomes active is less
        than or equal to mteTriggerThresholdFalling and
        mteTriggerThresholdStartup is equal to 'falling' or
        'risingOrFalling', then one mteTriggerThresholdRisingEvent is
        triggered for that instance."
    DEFVAL { risingOrFalling }
    ::= { mteTriggerThresholdEntry 1 }

mteTriggerThresholdRising OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "A threshold value to check against if mteTriggerType is
        'threshold'.

        When the current sampled value is greater than or equal to
        this threshold, and the value at the last sampling interval
        was less than this threshold, one
        mteTriggerThresholdRisingEvent is triggered.  That event is
        also triggered if the first sample after this entry becomes
        active is greater than or equal to this threshold and
        mteTriggerThresholdStartup is equal to 'rising' or
        'risingOrFalling'.

        After a rising event is generated, another such event is not
        triggered until the sampled value falls below this threshold
        and reaches mteTriggerThresholdFalling."
    DEFVAL { 0 }



Kavasseri & Stewart         Standards Track                    [Page 26]

RFC 2981                       Event MIB                    October 2000


    ::= { mteTriggerThresholdEntry 2 }

mteTriggerThresholdFalling OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "A threshold value to check against if mteTriggerType is
        'threshold'.

        When the current sampled value is less than or equal to this
        threshold, and the value at the last sampling interval was
        greater than this threshold, one
        mteTriggerThresholdFallingEvent is triggered.  That event is
        also triggered if the first sample after this entry becomes
        active is less than or equal to this threshold and
        mteTriggerThresholdStartup is equal to 'falling' or
        'risingOrFalling'.

        After a falling event is generated, another such event is not
        triggered until the sampled value rises above this threshold
        and reaches mteTriggerThresholdRising."
    DEFVAL { 0 }
    ::= { mteTriggerThresholdEntry 3 }

mteTriggerThresholdDeltaRising OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "A threshold value to check against if mteTriggerType is
        'threshold'.

        When the delta value (difference) between the current sampled
        value (value(n)) and the previous sampled value (value(n-1))
        is greater than or equal to this threshold,
        and the delta value calculated at the last sampling interval
        (i.e. value(n-1) - value(n-2)) was less than this threshold,
        one mteTriggerThresholdDeltaRisingEvent is triggered. That event
        is also triggered if the first delta value calculated after this
        entry becomes active, i.e. value(2) - value(1), where value(1)
        is the first sample taken of that instance, is greater than or
        equal to this threshold.

        After a rising event is generated, another such event is not
        triggered until the delta value falls below this threshold and
        reaches mteTriggerThresholdDeltaFalling."
    DEFVAL { 0 }



Kavasseri & Stewart         Standards Track                    [Page 27]

RFC 2981                       Event MIB                    October 2000


    ::= { mteTriggerThresholdEntry 4 }

mteTriggerThresholdDeltaFalling OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "A threshold value to check against if mteTriggerType is
        'threshold'.

        When the delta value (difference) between the current sampled
        value (value(n)) and the previous sampled value (value(n-1))
        is less than or equal to this threshold,
        and the delta value calculated at the last sampling interval
        (i.e. value(n-1) - value(n-2)) was greater than this threshold,
        one mteTriggerThresholdDeltaFallingEvent is triggered. That event
        is also triggered if the first delta value calculated after this
        entry becomes active, i.e. value(2) - value(1), where value(1)
        is the first sample taken of that instance, is less than or
        equal to this threshold.

        After a falling event is generated, another such event is not
        triggered until the delta value falls below this threshold and
        reaches mteTriggerThresholdDeltaRising."
    DEFVAL { 0 }
    ::= { mteTriggerThresholdEntry 5 }

mteTriggerThresholdObjectsOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerThresholdObjects, the mteOwner of a group
        of objects from mteObjectsTable."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 6 }

mteTriggerThresholdObjects OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteObjectsName of a group of objects from
        mteObjectsTable.  These objects are to be added to any
        Notification resulting from the firing of this trigger for
        this test.

        A list of objects may also be added based on the overall



Kavasseri & Stewart         Standards Track                    [Page 28]

RFC 2981                       Event MIB                    October 2000


        trigger, the event or other settings in mteTriggerTest.

        A length of 0 indicates no additional objects."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 7 }

mteTriggerThresholdRisingEventOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerThresholdRisingEvent, the mteOwner of an
        event entry from mteEventTable."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 8 }

mteTriggerThresholdRisingEvent OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteEventName of the event to invoke when mteTriggerType is
        'threshold' and this trigger fires based on
        mteTriggerThresholdRising.  A length of 0 indicates no event."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 9 }

mteTriggerThresholdFallingEventOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerThresholdFallingEvent, the mteOwner of an
        event entry from mteEventTable."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 10 }

mteTriggerThresholdFallingEvent OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteEventName of the event to invoke when mteTriggerType is
        'threshold' and this trigger fires based on
        mteTriggerThresholdFalling.  A length of 0 indicates no event."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 11 }




Kavasseri & Stewart         Standards Track                    [Page 29]

RFC 2981                       Event MIB                    October 2000


mteTriggerThresholdDeltaRisingEventOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerThresholdDeltaRisingEvent, the mteOwner
        of an event entry from mteEventTable."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 12 }

mteTriggerThresholdDeltaRisingEvent OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteEventName of the event to invoke when mteTriggerType is
        'threshold' and this trigger fires based on
        mteTriggerThresholdDeltaRising. A length of 0 indicates
        no event."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 13 }

mteTriggerThresholdDeltaFallingEventOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteTriggerThresholdDeltaFallingEvent, the mteOwner
        of an event entry from mteEventTable."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 14 }

mteTriggerThresholdDeltaFallingEvent OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteEventName of the event to invoke when mteTriggerType is
        'threshold' and this trigger fires based on
        mteTriggerThresholdDeltaFalling.  A length of 0 indicates
        no event."
    DEFVAL { ''H }
    ::= { mteTriggerThresholdEntry 15 }

--
-- Objects Table
--




Kavasseri & Stewart         Standards Track                    [Page 30]

RFC 2981                       Event MIB                    October 2000


mteObjectsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteObjectsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of objects that can be added to notifications based
        on the trigger, trigger test, or event, as pointed to by
        entries in those tables."
    ::= { mteObjects 1 }

mteObjectsEntry OBJECT-TYPE
    SYNTAX      MteObjectsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A group of objects.  Applications create and delete entries
        using mteObjectsEntryStatus.

        When adding objects to a notification they are added in the
        lexical order of their index in this table.  Those associated
        with a trigger come first, then trigger test, then event."
    INDEX       { mteOwner, mteObjectsName, mteObjectsIndex }
    ::= { mteObjectsTable 1 }

MteObjectsEntry ::= SEQUENCE {
    mteObjectsName                      SnmpAdminString,
    mteObjectsIndex                     Unsigned32,
    mteObjectsID                        OBJECT IDENTIFIER,
    mteObjectsIDWildcard                TruthValue,
    mteObjectsEntryStatus               RowStatus
    }

mteObjectsName OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (1..32))
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A locally-unique, administratively assigned name for a group
        of objects."
    ::= { mteObjectsEntry 1 }

mteObjectsIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An arbitrary integer for the purpose of identifying
        individual objects within a mteObjectsName group.



Kavasseri & Stewart         Standards Track                    [Page 31]

RFC 2981                       Event MIB                    October 2000


        Objects within a group are placed in the notification in the
        numerical order of this index.

        Groups are placed in the notification in the order of the
        selections for overall trigger, trigger test, and event.
        Within trigger test they are in the same order as the
        numerical values of the bits defined for mteTriggerTest.

        Bad object identifiers or a mismatch between truncating the
        identifier and the value of mteDeltaDiscontinuityIDWildcard
        result in operation as one would expect when providing the
        wrong identifier to a Get operation.  The Get will fail or get
        the wrong object.  If the object is not available it is omitted
        from the notification."
    ::= { mteObjectsEntry 2 }

mteObjectsID OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The object identifier of a MIB object to add to a
        Notification that results from the firing of a trigger.

        This may be wildcarded by truncating all or part of the
        instance portion, in which case the instance portion of the
        OID for obtaining this object will be the same as that used
        in obtaining the mteTriggerValueID that fired.  If such
        wildcarding is applied, mteObjectsIDWildcard must be
        'true' and if not it must be 'false'.

        Each instance that fills the wildcard is independent of any
        additional instances, that is, wildcarded objects operate
        as if there were a separate table entry for each instance
        that fills the wildcard without having to actually predict
        all possible instances ahead of time."
    DEFVAL { zeroDotZero }
    ::= { mteObjectsEntry 3 }

mteObjectsIDWildcard OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Control for whether mteObjectsID is to be treated as
        fully-specified or wildcarded, with 'true' indicating wildcard."
    DEFVAL { false }
    ::= { mteObjectsEntry 4 }



Kavasseri & Stewart         Standards Track                    [Page 32]

RFC 2981                       Event MIB                    October 2000


mteObjectsEntryStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The control that allows creation and deletion of entries.
        Once made active an entry MAY not be modified except to
        delete it."
    ::= { mteObjectsEntry 5 }

--
-- Event Section
--

-- Counters

mteEventFailures OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of times an attempt to invoke an event
        has failed.  This counts individually for each
        attempt in a group of targets or each attempt for a
        wildcarded trigger object."
    ::= { mteEvent 1 }

--
-- Event Table
--

mteEventTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of management event action information."
    ::= { mteEvent 2 }

mteEventEntry OBJECT-TYPE
    SYNTAX      MteEventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a single event.  Applications create and
        delete entries using mteEventEntryStatus."
    INDEX       { mteOwner, IMPLIED mteEventName }
    ::= { mteEventTable 1 }



Kavasseri & Stewart         Standards Track                    [Page 33]

RFC 2981                       Event MIB                    October 2000


MteEventEntry ::= SEQUENCE {
    mteEventName                        SnmpAdminString,
    mteEventComment                     SnmpAdminString,
    mteEventActions                     BITS,
    mteEventEnabled                     TruthValue,
    mteEventEntryStatus                 RowStatus
    }

mteEventName OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (1..32))
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A locally-unique, administratively assigned name for the
        event."
    ::= { mteEventEntry 1 }

mteEventComment OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "A description of the event's function and use."
    DEFVAL { ''H }
    ::= { mteEventEntry 2 }

mteEventActions OBJECT-TYPE
    SYNTAX      BITS { notification(0), set(1) }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The actions to perform when this event occurs.

        For 'notification', Traps and/or Informs are sent according
        to the configuration in the SNMP Notification MIB.

        For 'set', an SNMP Set operation is performed according to
        control values in this entry."
    DEFVAL { {} }  -- No bits set.
    ::= { mteEventEntry 3 }

mteEventEnabled OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "A control to allow an event to be configured but not used.
        When the value is 'false' the event does not execute even if



Kavasseri & Stewart         Standards Track                    [Page 34]

RFC 2981                       Event MIB                    October 2000


        triggered."
    DEFVAL { false }
    ::= { mteEventEntry 4 }

mteEventEntryStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "The control that allows creation and deletion of entries.
        Once made active an entry MAY not be modified except to
        delete it."
    ::= { mteEventEntry 5 }

--
-- Event Notification Table
--

mteEventNotificationTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteEventNotificationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of information about notifications to be sent as a
        consequence of management events."
    ::= { mteEvent 3 }

mteEventNotificationEntry OBJECT-TYPE
    SYNTAX      MteEventNotificationEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about a single event's notification.  Entries
        automatically exist in this this table for each mteEventEntry
        that has 'notification' set in mteEventActions."
    INDEX       { mteOwner, IMPLIED mteEventName }
    ::= { mteEventNotificationTable 1 }

MteEventNotificationEntry ::= SEQUENCE {
    mteEventNotification                OBJECT IDENTIFIER,
    mteEventNotificationObjectsOwner    SnmpAdminString,
    mteEventNotificationObjects         SnmpAdminString
    }

mteEventNotification OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-write
    STATUS      current



Kavasseri & Stewart         Standards Track                    [Page 35]

RFC 2981                       Event MIB                    October 2000


    DESCRIPTION
        "The object identifier from the NOTIFICATION-TYPE for the
        notification to use if metEventActions has 'notification' set."
    DEFVAL { zeroDotZero }
    ::= { mteEventNotificationEntry 1 }

mteEventNotificationObjectsOwner OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "To go with mteEventNotificationObjects, the mteOwner of a
        group of objects from mteObjectsTable."
    DEFVAL { ''H }
    ::= { mteEventNotificationEntry 2 }

mteEventNotificationObjects OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The mteObjectsName of a group of objects from
        mteObjectsTable if mteEventActions has 'notification' set.
        These objects are to be added to any Notification generated by
        this event.

        Objects may also be added based on the trigger that stimulated
        the event.

        A length of 0 indicates no additional objects."
    DEFVAL { ''H }
    ::= { mteEventNotificationEntry 3 }

--
-- Event Set Table
--

mteEventSetTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF MteEventSetEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of management event action information."
    ::= { mteEvent 4 }

mteEventSetEntry OBJECT-TYPE
    SYNTAX      MteEventSetEntry
    MAX-ACCESS  not-accessible



Kavasseri & Stewart         Standards Track                    [Page 36]

RFC 2981                       Event MIB                    October 2000


    STATUS      current
    DESCRIPTION
        "Information about a single event's set option.  Entries
        automatically exist in this this table for each mteEventEntry
        that has 'set' set in mteEventActions."
    INDEX       { mteOwner, IMPLIED mteEventName }
    ::= { mteEventSetTable 1 }

MteEventSetEntry ::= SEQUENCE {
    mteEventSetObject                   OBJECT IDENTIFIER,
    mteEventSetObjectWildcard           TruthValue,
    mteEventSetValue                    Integer32,
    mteEventSetTargetTag                SnmpTagValue,
    mteEventSetContextName              SnmpAdminString,
    mteEventSetContextNameWildcard      TruthValue
    }

mteEventSetObject OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The object identifier from the MIB object to set if
        mteEventActions has 'set' set.

        This object identifier may be wildcarded by leaving
        sub-identifiers off the end, in which case
        nteEventSetObjectWildCard must be 'true'.

        If mteEventSetObject is wildcarded the instance used to set the
        object to which it points is the same as the instance from the
        value of mteTriggerValueID that triggered the event.

        Each instance that fills the wildcard is independent of any
        additional instances, that is, wildcarded objects operate
        as if there were a separate table entry for each instance
        that fills the wildcard without having to actually predict
        all possible instances ahead of time.

        Bad object identifiers or a mismatch between truncating the
        identifier and the value of mteSetObjectWildcard
        result in operation as one would expect when providing the
        wrong identifier to a Set operation.  The Set will fail or set
        the wrong object.  If the value syntax of the destination
        object is not correct, the Set fails with the normal SNMP
        error code."
    DEFVAL { zeroDotZero }
    ::= { mteEventSetEntry 1 }



Kavasseri & Stewart         Standards Track                    [Page 37]

RFC 2981                       Event MIB                    October 2000


mteEventSetObjectWildcard OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Control over whether mteEventSetObject is to be treated as
        fully-specified or wildcarded, with 'true' indicating wildcard
        if mteEventActions has 'set' set."
    DEFVAL { false }
    ::= { mteEventSetEntry 2 }

mteEventSetValue OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value to which to set the object at mteEventSetObject
        if mteEventActions has 'set' set."
    DEFVAL { 0 }
    ::= { mteEventSetEntry 3 }

mteEventSetTargetTag OBJECT-TYPE
    SYNTAX      SnmpTagValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The tag for the target(s) at which to set the object at
        mteEventSetObject to mteEventSetValue if mteEventActions
        has 'set' set.

        Systems limited to self management MAY reject a non-zero
        length for the value of this object.

        A length of 0 indicates the local system.  In this case,
        access to the objects indicated by mteEventSetObject is under
        the security credentials of the requester that set
        mteTriggerEntryStatus to 'active'.  Those credentials are the
        input parameters for isAccessAllowed from the Architecture for
        Describing SNMP Management Frameworks.

        Otherwise access rights are checked according to the security
        parameters resulting from the tag."
    DEFVAL { ''H }
    ::= { mteEventSetEntry 4 }

mteEventSetContextName OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-write



Kavasseri & Stewart         Standards Track                    [Page 38]

RFC 2981                       Event MIB                    October 2000


    STATUS      current
    DESCRIPTION
        "The management context in which to set mteEventObjectID.
        if mteEventActions has 'set' set.

        This may be wildcarded by leaving characters off the end.  To
        indicate such wildcarding mteEventSetContextNameWildcard must
        be 'true'.

        If this context name is wildcarded the value used to complete
        the wildcarding of mteTriggerContextName will be appended."
    DEFVAL { ''H }
    ::= { mteEventSetEntry 5 }

mteEventSetContextNameWildcard OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Control for whether mteEventSetContextName is to be treated as
        fully-specified or wildcarded, with 'true' indicating wildcard
        if mteEventActions has 'set' set."
    DEFVAL { false }
    ::= { mteEventSetEntry 6 }

--
-- Notifications
--

dismanEventMIBNotificationPrefix OBJECT IDENTIFIER ::=
    { dismanEventMIB 2 }
dismanEventMIBNotifications OBJECT IDENTIFIER ::=
    { dismanEventMIBNotificationPrefix 0 }
dismanEventMIBNotificationObjects OBJECT IDENTIFIER
   ::= { dismanEventMIBNotificationPrefix 1 }

--
-- Notification Objects
--

mteHotTrigger OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The name of the trigger causing the notification."
    ::= { dismanEventMIBNotificationObjects 1 }




Kavasseri & Stewart         Standards Track                    [Page 39]

RFC 2981                       Event MIB                    October 2000


mteHotTargetName OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The SNMP Target MIB's snmpTargetAddrName related to the
        notification."
    ::= { dismanEventMIBNotificationObjects 2 }

mteHotContextName OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The context name related to the notification.  This MUST be as
        fully-qualified as possible, including filling in wildcard
        information determined in processing."
    ::= { dismanEventMIBNotificationObjects 3 }

mteHotOID OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The object identifier of the destination object related to the
        notification.  This MUST be as fully-qualified as possible,
        including filling in wildcard information determined in
        processing.

        For a trigger-related notification this is from
        mteTriggerValueID.

        For a set failure this is from mteEventSetObject."
    ::= { dismanEventMIBNotificationObjects 4 }

mteHotValue OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "The value of the object at mteTriggerValueID when a
        trigger fired."
    ::= { dismanEventMIBNotificationObjects 5 }

mteFailedReason OBJECT-TYPE
    SYNTAX      FailureReason
    MAX-ACCESS  accessible-for-notify
    STATUS      current



Kavasseri & Stewart         Standards Track                    [Page 40]

RFC 2981                       Event MIB                    October 2000


    DESCRIPTION
        "The reason for the failure of an attempt to check for a
        trigger condition or set an object in response to an event."
    ::= { dismanEventMIBNotificationObjects 6 }

--
-- Notifications
--

mteTriggerFired NOTIFICATION-TYPE
    OBJECTS { mteHotTrigger,
              mteHotTargetName,
              mteHotContextName,
              mteHotOID,
              mteHotValue }
    STATUS  current
    DESCRIPTION
        "Notification that the trigger indicated by the object
        instances has fired, for triggers with mteTriggerType
        'boolean' or 'existence'."
    ::= { dismanEventMIBNotifications 1 }

mteTriggerRising NOTIFICATION-TYPE
    OBJECTS { mteHotTrigger,
              mteHotTargetName,
              mteHotContextName,
              mteHotOID,
              mteHotValue }
    STATUS  current
    DESCRIPTION
        "Notification that the rising threshold was met for triggers
        with mteTriggerType 'threshold'."
    ::= { dismanEventMIBNotifications 2 }

mteTriggerFalling NOTIFICATION-TYPE
    OBJECTS { mteHotTrigger,
              mteHotTargetName,
              mteHotContextName,
              mteHotOID,
              mteHotValue }
    STATUS  current
    DESCRIPTION
        "Notification that the falling threshold was met for triggers
        with mteTriggerType 'threshold'."
    ::= { dismanEventMIBNotifications 3 }

mteTriggerFailure NOTIFICATION-TYPE
    OBJECTS { mteHotTrigger,



Kavasseri & Stewart         Standards Track                    [Page 41]

RFC 2981                       Event MIB                    October 2000


              mteHotTargetName,
              mteHotContextName,
              mteHotOID,
              mteFailedReason }
    STATUS  current
    DESCRIPTION
        "Notification that an attempt to check a trigger has failed.

        The network manager must enable this notification only with
        a certain fear and trembling, as it can easily crowd out more
        important information.  It should be used only to help diagnose
        a problem that has appeared in the error counters and can not
        be found otherwise."
    ::= { dismanEventMIBNotifications 4 }

mteEventSetFailure NOTIFICATION-TYPE
    OBJECTS { mteHotTrigger,
              mteHotTargetName,
              mteHotContextName,
              mteHotOID,
              mteFailedReason }
    STATUS  current
    DESCRIPTION
        "Notification that an attempt to do a set in response to an
        event has failed.

        The network manager must enable this notification only with
        a certain fear and trembling, as it can easily crowd out more
        important information.  It should be used only to help diagnose
        a problem that has appeared in the error counters and can not
        be found otherwise."
    ::= { dismanEventMIBNotifications 5 }

--
-- Conformance
--

dismanEventMIBConformance OBJECT IDENTIFIER ::= { dismanEventMIB 3 }
dismanEventMIBCompliances OBJECT IDENTIFIER ::=
    { dismanEventMIBConformance 1 }
dismanEventMIBGroups      OBJECT IDENTIFIER ::=
    { dismanEventMIBConformance 2 }

-- Compliance

dismanEventMIBCompliance MODULE-COMPLIANCE
        STATUS current
        DESCRIPTION



Kavasseri & Stewart         Standards Track                    [Page 42]

RFC 2981                       Event MIB                    October 2000


                "The compliance statement for entities which implement
                the Event MIB."
        MODULE  -- this module
                MANDATORY-GROUPS {
                        dismanEventResourceGroup,
                        dismanEventTriggerGroup,
                        dismanEventObjectsGroup,
                        dismanEventEventGroup,
                        dismanEventNotificationObjectGroup,
                        dismanEventNotificationGroup
                }

                OBJECT mteTriggerTargetTag
                MIN-ACCESS  read-only
                DESCRIPTION
                        "Write access is not required, thus limiting
                        monitoring to the local system or pre-configured
                        remote systems."

                OBJECT mteEventSetTargetTag
                MIN-ACCESS  read-only
                DESCRIPTION
                        "Write access is not required, thus limiting
                        setting to the local system or pre-configured
                        remote systems."

                OBJECT mteTriggerValueIDWildcard
                MIN-ACCESS  read-only
                DESCRIPTION
                        "Write access is not required, thus allowing
                        the system not to implement wildcarding."

                OBJECT mteTriggerContextNameWildcard
                MIN-ACCESS  read-only
                DESCRIPTION
                        "Write access is not required, thus allowing
                        the system not to implement wildcarding."


                OBJECT mteObjectsIDWildcard
                MIN-ACCESS  read-only
                DESCRIPTION
                        "Write access is not required, thus allowing
                        the system not to implement wildcarding."

                OBJECT mteEventSetContextNameWildcard
                MIN-ACCESS  read-only
                DESCRIPTION



Kavasseri & Stewart         Standards Track                    [Page 43]

RFC 2981                       Event MIB                    October 2000


                        "Write access is not required, thus allowing
                        the system not to implement wildcarding."

        ::= { dismanEventMIBCompliances 1 }

-- Units of Conformance

dismanEventResourceGroup OBJECT-GROUP
        OBJECTS {
                mteResourceSampleMinimum,
                mteResourceSampleInstanceMaximum,
                mteResourceSampleInstances,
                mteResourceSampleInstancesHigh,
                mteResourceSampleInstanceLacks
        }
        STATUS current
        DESCRIPTION
                "Event resource status and control objects."
        ::= { dismanEventMIBGroups 1 }

dismanEventTriggerGroup OBJECT-GROUP
        OBJECTS {
                mteTriggerFailures,

                mteTriggerComment,
                mteTriggerTest,
                mteTriggerSampleType,
                mteTriggerValueID,
                mteTriggerValueIDWildcard,
                mteTriggerTargetTag,
                mteTriggerContextName,
                mteTriggerContextNameWildcard,
                mteTriggerFrequency,
                mteTriggerObjectsOwner,
                mteTriggerObjects,
                mteTriggerEnabled,
                mteTriggerEntryStatus,

                mteTriggerDeltaDiscontinuityID,
                mteTriggerDeltaDiscontinuityIDWildcard,
                mteTriggerDeltaDiscontinuityIDType,
                mteTriggerExistenceTest,
                mteTriggerExistenceStartup,
                mteTriggerExistenceObjectsOwner,
                mteTriggerExistenceObjects,
                mteTriggerExistenceEventOwner,
                mteTriggerExistenceEvent,




Kavasseri & Stewart         Standards Track                    [Page 44]

RFC 2981                       Event MIB                    October 2000


                mteTriggerBooleanComparison,
                mteTriggerBooleanValue,
                mteTriggerBooleanStartup,
                mteTriggerBooleanObjectsOwner,
                mteTriggerBooleanObjects,
                mteTriggerBooleanEventOwner,
                mteTriggerBooleanEvent,

                mteTriggerThresholdStartup,
                mteTriggerThresholdObjectsOwner,
                mteTriggerThresholdObjects,
                mteTriggerThresholdRising,
                mteTriggerThresholdFalling,
                mteTriggerThresholdDeltaRising,
                mteTriggerThresholdDeltaFalling,
                mteTriggerThresholdRisingEventOwner,
                mteTriggerThresholdRisingEvent,
                mteTriggerThresholdFallingEventOwner,
                mteTriggerThresholdFallingEvent,
                mteTriggerThresholdDeltaRisingEventOwner,
                mteTriggerThresholdDeltaRisingEvent,
                mteTriggerThresholdDeltaFallingEventOwner,
                mteTriggerThresholdDeltaFallingEvent
        }
        STATUS current
        DESCRIPTION
                "Event triggers."
        ::= { dismanEventMIBGroups 2 }

dismanEventObjectsGroup OBJECT-GROUP
        OBJECTS {
                mteObjectsID,
                mteObjectsIDWildcard,
                mteObjectsEntryStatus
        }
        STATUS current
        DESCRIPTION
                "Supplemental objects."
        ::= { dismanEventMIBGroups 3 }

dismanEventEventGroup OBJECT-GROUP
        OBJECTS {
                mteEventFailures,

                mteEventComment,
                mteEventActions,
                mteEventEnabled,
                mteEventEntryStatus,



Kavasseri & Stewart         Standards Track                    [Page 45]

RFC 2981                       Event MIB                    October 2000


                mteEventNotification,
                mteEventNotificationObjectsOwner,
                mteEventNotificationObjects,

                mteEventSetObject,
                mteEventSetObjectWildcard,
                mteEventSetValue,
                mteEventSetTargetTag,
                mteEventSetContextName,
                mteEventSetContextNameWildcard
        }
        STATUS current
        DESCRIPTION
                "Events."
        ::= { dismanEventMIBGroups 4 }

dismanEventNotificationObjectGroup OBJECT-GROUP
        OBJECTS {
                mteHotTrigger,
                mteHotTargetName,
                mteHotContextName,
                mteHotOID,
                mteHotValue,
                mteFailedReason
        }
        STATUS current
        DESCRIPTION
                "Notification objects."
        ::= { dismanEventMIBGroups 5 }

dismanEventNotificationGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
                mteTriggerFired,
                mteTriggerRising,
                mteTriggerFalling,
                mteTriggerFailure,
                mteEventSetFailure
        }
        STATUS current
        DESCRIPTION
                "Notifications."
        ::= { dismanEventMIBGroups 6 }

END







Kavasseri & Stewart         Standards Track                    [Page 46]

RFC 2981                       Event MIB                    October 2000


8.  Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards- related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.

9.  Acknowledgements

   This MIB contains considerable contributions from the RMON MIB, the
   Distributed Management Design Team (Andy Bierman, Maria Greene, Bob
   Stewart, and Steve Waldbusser), the Distributed Management Working
   Group, and colleagues at Cisco.

10.  References

   [RFC2571]   Harrington, D., Presuhn, R. and B. Wijnen, "An
               Architecture for Describing SNMP Management Frameworks",
               RFC 2571, April 1999.

   [RFC1155]   Rose, M. and K. McCloghrie, "Structure and Identification
               of Management Information for TCP/IP-based Internets",
               STD 16, RFC 1155, May 1990.

   [RFC1212]   Rose, M. and K. McCloghrie, "Concise MIB Definitions",
               STD 16, RFC 1212, March 1991.

   [RFC1215]   Rose, M., "A Convention for Defining Traps for use with
               the SNMP", RFC 1215, March 1991.







Kavasseri & Stewart         Standards Track                    [Page 47]

RFC 2981                       Event MIB                    October 2000


   [RFC2578]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
               Rose, M. and S. Waldbusser, "Structure of Management
               Information Version 2 (SMIv2)", STD 58, RFC 2578, April
               1999.

   [RFC2579]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
               Rose, M. and S. Waldbusser, "Textual Conventions for
               SMIv2", STD 58, RFC 2579, April 1999.

   [RFC2580]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
               Rose, M. and S. Waldbusser, "Conformance Statements for
               SMIv2", STD 58, RFC 2580, April 1999.

   [RFC1157]   Case, J., Fedor, M., Schoffstall, M. and J. Davin,
               "Simple Network Management Protocol", STD 15, RFC 1157,
               May 1990.

   [RFC1901]   Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
               "Introduction to Community-based SNMPv2", RFC 1901,
               January 1996.

   [RFC1906]   Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
               "Transport Mappings for Version 2 of the Simple Network
               Management Protocol (SNMPv2)", RFC 1906, January 1996.

   [RFC2572]   Case, J., Harrington D., Presuhn R. and B. Wijnen,
               "Message Processing and Dispatching for the Simple
               Network Management Protocol (SNMP)", RFC 2572, April
               1999.

   [RFC2574]   Blumenthal, U. and B. Wijnen, "User-based Security Model
               (USM) for version 3 of the Simple Network Management
               Protocol (SNMPv3)", RFC 2574, April 1999.

   [RFC1905]   Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
               "Protocol Operations for Version 2 of the Simple Network
               Management Protocol (SNMPv2)", RFC 1905, January 1996.

   [RFC2573]   Levi, D., Meyer, P. and B. Stewart, "SNMPv3
               Applications", RFC 2573, April 1999.

   [RFC2575]   Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based
               Access Control Model (VACM) for the Simple Network
               Management Protocol (SNMP)", RFC 2575, April 1999.

   [RFC2570]   Case, J., Mundy, R., Partain, D. and B. Stewart,
               "Introduction to Version 3 of the Internet-standard
               Network Management Framework", RFC 2570, April 1999.



Kavasseri & Stewart         Standards Track                    [Page 48]

RFC 2981                       Event MIB                    October 2000


   [RFC1903]   Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
               "Coexistence between Version 1 and version 2 of the
               Internet-standard Network Management Framework", RFC
               1903, January 1996.

   [RFC2981]   Stewart, B., "Event MIB", RFC 2981, October 2000.

   [RFC1757]   Waldbusser, S., "Remote Network Monitoring Management
               Information Base", RFC 1757, February 1995.

   [RFC1451]   Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
               "Manager-to- Manager Management Information Base", RFC
               1451, April 1993.

   [RFC2982]   Stewart, B., "Distributed Management Expression MIB", RFC
               2982, October 2000.

   [LOG-MIB]   Stewart, B., "Notification Log MIB", Work in Progress.


11.  Security Considerations

   Security issues are discussed in the Security section and in the
   DESCRIPTION clauses of relevant objects.

12.  Author's Address

   Bob Stewart
   Cisco Systems, Inc.
   170 West Tasman Drive
   San Jose, CA 95134-1706
   U.S.A.

13.  Editor's Address

   Ramanathan Kavasseri
   Cisco Systems, Inc.
   170 West Tasman Drive
   San Jose, CA 95134-1706
   U.S.A.

   Phone: +1 408 527 2446
   EMail: ramk@cisco.com








Kavasseri & Stewart         Standards Track                    [Page 49]

RFC 2981                       Event MIB                    October 2000


14.  Full Copyright Statement

   Copyright (C) The Internet Society (2000).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.



















Kavasseri & Stewart         Standards Track                    [Page 50]