💾 Archived View for gmi.noulin.net › rfc › rfc2239.gmi captured on 2022-04-28 at 23:29:40. Gemini links have been rewritten to link to archived content
⬅️ Previous capture (2021-12-05)
-=-=-=-=-=-=-
Obsoleted by:
Keywords: MAUS-MIB
Network Working Group K. de Graaf Request for Comments: 2239 3Com Corporation Category: Standards Track D. Romascanu Madge Networks Ltd. D. McMaster Cisco Systems Inc. K. McCloghrie Cisco Systems Inc. S. Roberts Farallon Computing, Inc. November 1997 Definitions of Managed Objects for IEEE 802.3 Medium Attachment Units (MAUs) using SMIv2 Status of this Memo This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited. Copyright Notice Copyright (C) The Internet Society (1997). All Rights Reserved. Table of Contents 1 The SNMPv2 Network Management Framework ............... 2 1.1 Object Definitions .................................. 2 2 Overview .............................................. 3 2.1 Relationship to RFC 1515 ............................ 3 2.2 MAU Management ...................................... 3 2.3 Relationship to Other MIBs .......................... 3 2.3.1 Relationship to the MIB-II 'interfaces' group ..... 3 2.3.2 Relationship to the 802.3 Repeater MIB ............ 4 2.4 Management of Internal MAUs ......................... 4 3 Definitions ........................................... 4 4 Acknowledgements ...................................... 39 5 References ............................................ 40 6 Security Considerations ............................... 41 7 Authors' Addresses .................................... 41 8 Full Copyright Statement .............................. 43 de Graaf, et. al. Standards Track [Page 1] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 Abstract This memo defines an portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it defines objects for managing 10 and 100 Mb/second Medium Attachment Units (MAUs) based on IEEE Std 802.3 Section 30, "10 & 100 Mb/s Management," October 26, 1995. 1. The SNMPv2 Network Management Framework The SNMPv2 Network Management Framework presently consists of three major components. They are: o the SMI, described in RFC 1902 [6] - the mechanisms used for describing and naming objects for the purpose of management. o the MIB-II, STD 17, RFC 1213 [5] - the core set of managed objects for the Internet suite of protocols. o the protocol, STD 15, RFC 1157 [10] and/or RFC 1905 [9] - the protocol used for accessing managed information. Textual conventions are defined in RFC 1903 [7], and conformance statements are defined in RFC 1904 [8]. The Framework permits new objects to be defined for the purpose of experimentation and evaluation. 1.1. Object Definitions Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the subset of Abstract Syntax Notation One (ASN.1) defined in the SMI. In particular, each object type is named by an OBJECT IDENTIFIER, an administratively assigned name. The object type together with an object instance serves to uniquely identify a specific instantiation of the object. For human convenience, we often use a textual string, termed the descriptor, to refer to the object type. de Graaf, et. al. Standards Track [Page 2] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 2. Overview 2.1. Relationship to RFC 1515 This MIB is intended to be a superset of that defined by RFC 1515 [11], which will go to historic status. This MIB includes all of the objects contained in that MIB, plus several new ones which provide additional capabilities. Implementors are encouraged to support all applicable conformance groups in order to make the best use of the new functionality provided by this MIB. The new objects provide management support for: o management of 100 Mb/s devices o auto-negotiation on interface MAUs o jack management 2.2. MAU Management Instances of these object types represent attributes of an IEEE 802.3 MAU. Several types of MAUs are defined in the IEEE 802.3 CSMA/CD standard [1] and [2]. These MAUs may be connected to IEEE 802.3 repeaters or to 802.3 (Ethernet-like) interfaces. For convenience this document refers to these devices as "repeater MAUs" and "interface MAUs." The definitions presented here are based on Section 30.5, "Layer Management for 10 & 100 Mb/s Medium Attachment Units (MAUs)", and Annex 30A, "GDMO Specifications for 802.3 managed objects" of IEEE Std 802.3u-1995. That specification includes definitions for both 10Mb/s and 100Mb/s devices, and is essentially a superset of the 10Mb/s definitions given by IEEE 802.3 Section 20. This specification is intended to serve the same purpose: to provide for management of both 10Mb/s and 100Mb/s MAUs. 2.3. Relationship to Other MIBs It is assumed that an agent implementing this MIB will also implement (at least) the 'system' group defined in MIB-II [5]. The following sections identify other MIBs that such an agent should implement. 2.3.1. Relationship to the MIB-II 'interfaces' group The sections of this document that define interface MAU-related objects specify an extension to the 'interfaces' group of MIB-II. An agent implementing these interface-MAU related objects must also de Graaf, et. al. Standards Track [Page 3] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 implement the 'interfaces' group of MIB-II. The value of the object ifMauIfIndex is the same as the value of 'ifIndex' used to instantiate the interface to which the given MAU is connected. It is expected that an agent implementing the interface-MAU related objects in this MIB will also implement the Ethernet- like Interfaces MIB, RFC 1650. (Note that repeater ports are not represented as interfaces in the sense of MIB-II's 'interfaces' group.) 2.3.2. Relationship to the 802.3 Repeater MIB The section of this document that defines repeater MAU-related objects specifies an extension to the 802.3 Repeater MIB defined in [4]. An agent implementing these repeater-MAU related objects must also implement the 802.3 Repeater MIB. The values of 'rpMauGroupIndex' and 'rpMauPortIndex' used to instantiate a repeater MAU variable shall be the same as the values of 'rptrPortGroupIndex' and 'rptrPortIndex' used to instantiate the port to which the given MAU is connected. 2.4. Management of Internal MAUs In some situations, a MAU can be "internal" -- i.e., its functionality is implemented entirely within a device. For example, a managed repeater may contain an internal repeater- MAU and/or an internal interface-MAU through which management communications originating on one of the repeater's external ports pass in order to reach the management agent associated with the repeater. Such internal MAUs may or may not be managed. If they are managed, objects describing their attributes should appear in the appropriate MIB subtree: dot3RpMauBasicGroup for internal repeater-MAUs and dot3IfMauBasicGroup for internal interface-MAUs. 3. Definitions MAU-MIB DEFINITIONS ::= BEGIN IMPORTS Counter32, Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, mib-2 FROM SNMPv2-SMI TruthValue, TEXTUAL-CONVENTION de Graaf, et. al. Standards Track [Page 4] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF; mauMod MODULE-IDENTITY LAST-UPDATED "9710310000Z" ORGANIZATION "IETF HUB MIB Working Group" CONTACT-INFO "WG E-mail: hubmib@hprnd.rose.hp.com Chair: Dan Romascanu Postal: Madge Networks (Israel) Ltd. Atidim Technology Park, Bldg. 3 Tel Aviv 61131, Israel Tel: 972-3-6458414, 6458458 Fax: 972-3-6487146 E-mail: dromasca@madge.com Editor: Kathryn de Graaf Postal: 3Com Corporation 118 Turnpike Rd. Southborough, MA 01772 USA Tel: (508)229-1627 Fax: (508)490-5882 E-mail: kdegraaf@isd.3com.com" DESCRIPTION "Management information for 802.3 MAUs. The following references are used throughout this MIB module: [IEEE 802.3 Std] refers to IEEE 802.3/ISO 8802-3 Information processing systems - Local area networks - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications (1993), and to IEEE Std 802.3u-1995, Supplement to IEEE Std 802.3, clauses 22 through 29. [IEEE 802.3 Mgt] refers to IEEE 802.3u-1995, - 10 Mb/s & 100 Mb/s Management, Section 30 - Supplement to IEEE Std 802.3." ::= { snmpDot3MauMgt 6 } de Graaf, et. al. Standards Track [Page 5] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 snmpDot3MauMgt OBJECT IDENTIFIER ::= { mib-2 26 } -- textual conventions JackType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Common enumeration values for repeater and interface MAU jack types." SYNTAX INTEGER { other(1), rj45(2), rj45S(3), -- rj45 shielded db9(4), bnc(5), fAUI(6), -- female aui mAUI(7), -- male aui fiberSC(8), fiberMIC(9), fiberST(10), telco(11) } dot3RpMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 1 } dot3IfMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 2 } dot3BroadMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 3 } dot3IfMauAutoNegGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 5 } -- object identities for MAU types -- (see rpMauType and ifMauType for usage) dot3MauType OBJECT IDENTIFIER ::= { snmpDot3MauMgt 4 } dot3MauTypeAUI OBJECT-IDENTITY STATUS current DESCRIPTION "no internal MAU, view from AUI" ::= { dot3MauType 1 } dot3MauType10Base5 OBJECT-IDENTITY STATUS current DESCRIPTION "thick coax MAU (per 802.3 section 8)" ::= { dot3MauType 2 } de Graaf, et. al. Standards Track [Page 6] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 dot3MauTypeFoirl OBJECT-IDENTITY STATUS current DESCRIPTION "FOIRL MAU (per 802.3 section 9.9)" ::= { dot3MauType 3 } dot3MauType10Base2 OBJECT-IDENTITY STATUS current DESCRIPTION "thin coax MAU (per 802.3 section 10)" ::= { dot3MauType 4 } dot3MauType10BaseT OBJECT-IDENTITY STATUS current DESCRIPTION "UTP MAU (per 802.3 section 14)" ::= { dot3MauType 5 } dot3MauType10BaseFP OBJECT-IDENTITY STATUS current DESCRIPTION "passive fiber MAU (per 802.3 section 16)" ::= { dot3MauType 6 } dot3MauType10BaseFB OBJECT-IDENTITY STATUS current DESCRIPTION "sync fiber MAU (per 802.3 section 17)" ::= { dot3MauType 7 } dot3MauType10BaseFL OBJECT-IDENTITY STATUS current DESCRIPTION "async fiber MAU (per 802.3 section 18)" ::= { dot3MauType 8 } dot3MauType10Broad36 OBJECT-IDENTITY STATUS current DESCRIPTION "broadband DTE MAU (per 802.3 section 11). Note that 10BROAD36 MAUs can be attached to interfaces but not to repeaters." ::= { dot3MauType 9 } ------ new since RFC 1515: dot3MauType10BaseTHD OBJECT-IDENTITY STATUS current de Graaf, et. al. Standards Track [Page 7] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 DESCRIPTION "UTP MAU (per 802.3 section 14), half duplex mode" ::= { dot3MauType 10 } dot3MauType10BaseTFD OBJECT-IDENTITY STATUS current DESCRIPTION "UTP MAU (per 802.3 section 14), full duplex mode" ::= { dot3MauType 11 } dot3MauType10BaseFLHD OBJECT-IDENTITY STATUS current DESCRIPTION "async fiber MAU (per 802.3 section 18), half duplex mode" ::= { dot3MauType 12 } dot3MauType10BaseFLFD OBJECT-IDENTITY STATUS current DESCRIPTION "async fiber MAU (per 802.3 section 18), full duplex mode" ::= { dot3MauType 13 } dot3MauType100BaseT4 OBJECT-IDENTITY STATUS current DESCRIPTION "4 pair categ. 3 UTP (per 802.3 section 23)" ::= { dot3MauType 14 } dot3MauType100BaseTXHD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair categ. 5 UTP (per 802.3 section 25), half duplex mode" ::= { dot3MauType 15 } dot3MauType100BaseTXFD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair categ. 5 UTP (per 802.3 section 25), full duplex mode" ::= { dot3MauType 16 } dot3MauType100BaseFXHD OBJECT-IDENTITY STATUS current DESCRIPTION "X fiber over PMT (per 802.3 section 26), half de Graaf, et. al. Standards Track [Page 8] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 duplex mode" ::= { dot3MauType 17 } dot3MauType100BaseFXFD OBJECT-IDENTITY STATUS current DESCRIPTION "X fiber over PMT (per 802.3 section 26), full duplex mode" ::= { dot3MauType 18 } dot3MauType100BaseT2HD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair categ. 3 UTP (per 802.3 section 32), half duplex mode" ::= { dot3MauType 19 } dot3MauType100BaseT2FD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair categ. 3 UTP (per 802.3 section 32), full duplex mode" ::= { dot3MauType 20 } -- -- The Basic Repeater MAU Table -- rpMauTable OBJECT-TYPE SYNTAX SEQUENCE OF RpMauEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of descriptive and status information about the MAU(s) attached to the ports of a repeater." ::= { dot3RpMauBasicGroup 1 } rpMauEntry OBJECT-TYPE SYNTAX RpMauEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a single MAU." INDEX { rpMauGroupIndex, rpMauPortIndex, rpMauIndex } ::= { rpMauTable 1 } de Graaf, et. al. Standards Track [Page 9] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 RpMauEntry ::= SEQUENCE { rpMauGroupIndex Integer32, rpMauPortIndex Integer32, rpMauIndex Integer32, rpMauType OBJECT IDENTIFIER, rpMauStatus INTEGER, rpMauMediaAvailable INTEGER, rpMauMediaAvailableStateExits Counter32, rpMauJabberState INTEGER, rpMauJabberingStateEnters Counter32, rpMauFalseCarriers Counter32 } rpMauGroupIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the group containing the port to which the MAU described by this entry is connected. Note: In practice, a group will generally be a field-replaceable unit (i.e., module, card, or board) that can fit in the physical system enclosure, and the group number will correspond to a number marked on the physical enclosure. The group denoted by a particular value of this object is the same as the group denoted by the same value of rptrGroupIndex." ::= { rpMauEntry 1 } rpMauPortIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current de Graaf, et. al. Standards Track [Page 10] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 DESCRIPTION "This variable uniquely identifies the repeater port within group rpMauGroupIndex to which the MAU described by this entry is connected." REFERENCE "Reference RFC 1516, rptrPortIndex." ::= { rpMauEntry 2 } rpMauIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the MAU described by this entry from among other MAUs connected to the same port (rpMauPortIndex)." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID." ::= { rpMauEntry 3 } rpMauType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the 10 or 100 Mb/s baseband MAU type. An initial set of MAU types are defined above. The assignment of OBJECT IDENTIFIERs to new types of MAUs is managed by the IANA. If the MAU type is unknown, the object identifier unknownMauType OBJECT IDENTIFIER ::= { 0 0 } is returned. Note that unknownMauType is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.2, aMAUType." ::= { rpMauEntry 4 } rpMauStatus OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), operational(3), de Graaf, et. al. Standards Track [Page 11] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 standby(4), shutdown(5), reset(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The current state of the MAU. This object may be implemented as a read-only object by those agents and MAUs that do not implement software control of the MAU state. Some agents may not support setting the value of this object to some of the enumerated values. The value other(1) is returned if the MAU is in a state other than one of the states 2 through 6. The value unknown(2) is returned when the MAU's true state is unknown; for example, when it is being initialized. A MAU in the operational(3) state is fully functional, operates, and passes signals to its attached DTE or repeater port in accordance to its specification. A MAU in standby(4) state forces DI and CI to idle and the media transmitter to idle or fault, if supported. Standby(4) mode only applies to link type MAUs. The state of rpMauMediaAvailable is unaffected. A MAU in shutdown(5) state assumes the same condition on DI, CI, and the media transmitter as though it were powered down or not connected. The MAU may return other(1) value for the rpMauJabberState and rpMauMediaAvailable objects when it is in this state. For an AUI, this state will remove power from the AUI. Setting this variable to the value reset(6) resets the MAU in the same manner as a power-off, power- on cycle of at least one-half second would. The agent is not required to return the value reset (6). Setting this variable to the value operational(3), standby(4), or shutdown(5) causes the MAU to de Graaf, et. al. Standards Track [Page 12] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 assume the respective state except that setting a mixing-type MAU or an AUI to standby(4) will cause the MAU to enter the shutdown state." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.7, aMAUAdminState, 30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1, acRESETMAU." ::= { rpMauEntry 5 } rpMauMediaAvailable OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), available(3), notAvailable(4), remoteFault(5), invalidSignal(6), remoteJabber(7), remoteLinkLoss(8), remoteTest(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "If the MAU is a link or fiber type (FOIRL, 10BASE-T, 10BASE-F) then this is equivalent to the link test fail state/low light function. For an AUI or a coax (including broadband) MAU this indicates whether or not loopback is detected on the DI circuit. The value of this attribute persists between packets for MAU types AUI, 10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP. The value other(1) is returned if the mediaAvailable state is not one of 2 through 6. The value unknown(2) is returned when the MAU's true state is unknown; for example, when it is being initialized. At power-up or following a reset, the value of this attribute will be unknown for AUI, coax, and 10BASE-FP MAUs. For these MAUs loopback will be tested on each transmission during which no collision is detected. If DI is receiving input when DO returns to IDL after a transmission and there has been no collision during the transmission then loopback will be detected. The value of this attribute will only change during non-collided transmissions for AUI, de Graaf, et. al. Standards Track [Page 13] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 coax, and 10BASE-FP MAUs. For 100BASE-T4, 100BASE-TX and 100BASE-FX the enumerations match the states within the respective link integrity state diagrams, fig 23- 12 and 24-15 of sections 23 and 24 of [2]. Any MAU which implements management of auto- negotiation will map remote fault indication to remote fault. The value available(3) indicates that the link, light, or loopback is normal. The value notAvailable(4) indicates link loss, low light, or no loopback. The value remoteFault(5) indicates that a fault has been detected at the remote end of the link. This value applies to 10BASE-FB, 100BASE-T4 Far End Fault Indication and non-specified remote faults from a system running auto-negotiation. The values remoteJabber(7), remoteLinkLoss(8), and remoteTest(9) should be used instead of remoteFault(5) where the reason for remote fault is identified in the remote signaling protocol. The value invalidSignal(6) indicates that an invalid signal has been received from the other end of the link. InvalidSignal(6) applies only to MAUs of type 10BASE-FB. Where an IEEE Std 802.3u-1995 clause 22 MII is present, a logic one in the remote fault bit (reference section 22.2.4.2.8 of that document) maps to the value remoteFault(5), and a logic zero in the link status bit (reference section 22.2.4.2.10 of that document) maps to the value notAvailable(4). The value notAvailable(4) takes precedence over the value remoteFault(5)." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.4, aMediaAvailable." ::= { rpMauEntry 6 } rpMauMediaAvailableStateExits OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times that de Graaf, et. al. Standards Track [Page 14] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 rpMauMediaAvailable for this MAU instance leaves the state available(3)." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.5, aLoseMediaCounter." ::= { rpMauEntry 7 } rpMauJabberState OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), noJabber(3), jabbering(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value other(1) is returned if the jabber state is not 2, 3, or 4. The agent must always return other(1) for MAU type dot3MauTypeAUI. The value unknown(2) is returned when the MAU's true state is unknown; for example, when it is being initialized. If the MAU is not jabbering the agent returns noJabber(3). This is the 'normal' state. If the MAU is in jabber state the agent returns the jabbering(4) value." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.6, aJabber.jabberFlag." ::= { rpMauEntry 8 } rpMauJabberingStateEnters OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times that mauJabberState for this MAU instance enters the state jabbering(4). For MAUs of type dot3MauTypeAUI, dot3MauType100BaseT4, dot3MauType100BaseTX, and dot3MauType100BaseFX, this counter will always indicate zero." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.6, aJabber.jabberCounter." de Graaf, et. al. Standards Track [Page 15] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 ::= { rpMauEntry 9 } rpMauFalseCarriers OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of false carrier events during IDLE in 100BASE-X links. This counter does not increment at the symbol rate. It can increment after a valid carrier completion at a maximum rate of once per 100 ms until the next carrier event. This counter increments only for MAUs of type dot3MauType100BaseT4, dot3MauType100BaseTX, and dot3MauType100BaseFX. For all other MAU types, this counter will always indicate zero. The approximate minimum time for rollover of this counter is 7.4 hours." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.10, aFalseCarriers." ::= { rpMauEntry 10 } -- The rpJackTable applies to MAUs attached to repeaters -- which have one or more external jacks (connectors). rpJackTable OBJECT-TYPE SYNTAX SEQUENCE OF RpJackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the external jacks attached to MAUs attached to the ports of a repeater." ::= { dot3RpMauBasicGroup 2 } rpJackEntry OBJECT-TYPE SYNTAX RpJackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a particular jack." INDEX { rpMauGroupIndex, rpMauPortIndex, de Graaf, et. al. Standards Track [Page 16] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 rpMauIndex, rpJackIndex } ::= { rpJackTable 1 } RpJackEntry ::= SEQUENCE { rpJackIndex Integer32, rpJackType JackType } rpJackIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the jack described by this entry from among other jacks attached to the same MAU (rpMauIndex)." ::= { rpJackEntry 1 } rpJackType OBJECT-TYPE SYNTAX JackType MAX-ACCESS read-only STATUS current DESCRIPTION "The jack connector type, as it appears on the outside of the system." ::= { rpJackEntry 2 } -- -- The Basic Interface MAU Table -- ifMauTable OBJECT-TYPE SYNTAX SEQUENCE OF IfMauEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of descriptive and status information about MAU(s) attached to an interface." ::= { dot3IfMauBasicGroup 1 } ifMauEntry OBJECT-TYPE SYNTAX IfMauEntry de Graaf, et. al. Standards Track [Page 17] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a single MAU." INDEX { ifMauIfIndex, ifMauIndex } ::= { ifMauTable 1 } IfMauEntry ::= SEQUENCE { ifMauIfIndex Integer32, ifMauIndex Integer32, ifMauType OBJECT IDENTIFIER, ifMauStatus INTEGER, ifMauMediaAvailable INTEGER, ifMauMediaAvailableStateExits Counter32, ifMauJabberState INTEGER, ifMauJabberingStateEnters Counter32, ifMauFalseCarriers Counter32, ifMauTypeList Integer32, ifMauDefaultType OBJECT IDENTIFIER, ifMauAutoNegSupported TruthValue } ifMauIfIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the interface to which the MAU described by this entry is connected." REFERENCE "RFC 1213, ifIndex" ::= { ifMauEntry 1 } de Graaf, et. al. Standards Track [Page 18] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 ifMauIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the MAU described by this entry from among other MAUs connected to the same interface (ifMauIfIndex)." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID." ::= { ifMauEntry 2 } ifMauType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "This object identifies the 10 or 100 Mb/s baseband or broadband MAU type. An initial set of MAU types are defined above. The assignment of OBJECT IDENTIFIERs to new types of MAUs is managed by the IANA. If the MAU type is unknown, the object identifier unknownMauType OBJECT IDENTIFIER ::= { 0 0 } is returned. Note that unknownMauType is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value. This object represents the operational type of the MAU, as determined by either (1) the result of the auto-negotiation function or (2) if auto- negotiation is not enabled or is not implemented for this MAU, by the value of the object ifMauDefaultType. In case (2), a set to the object ifMauDefaultType will force the MAU into the new operating mode." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.2, aMAUType." ::= { ifMauEntry 3 } ifMauStatus OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), operational(3), de Graaf, et. al. Standards Track [Page 19] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 standby(4), shutdown(5), reset(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The current state of the MAU. This object may be implemented as a read-only object by those agents and MAUs that do not implement software control of the MAU state. Some agents may not support setting the value of this object to some of the enumerated values. The value other(1) is returned if the MAU is in a state other than one of the states 2 through 6. The value unknown(2) is returned when the MAU's true state is unknown; for example, when it is being initialized. A MAU in the operational(3) state is fully functional, operates, and passes signals to its attached DTE or repeater port in accordance to its specification. A MAU in standby(4) state forces DI and CI to idle and the media transmitter to idle or fault, if supported. Standby(4) mode only applies to link type MAUs. The state of ifMauMediaAvailable is unaffected. A MAU in shutdown(5) state assumes the same condition on DI, CI, and the media transmitter as though it were powered down or not connected. The MAU may return other(1) value for the ifMauJabberState and ifMauMediaAvailable objects when it is in this state. For an AUI, this state will remove power from the AUI. Setting this variable to the value reset(6) resets the MAU in the same manner as a power-off, power- on cycle of at least one-half second would. The agent is not required to return the value reset (6). Setting this variable to the value operational(3), standby(4), or shutdown(5) causes the MAU to de Graaf, et. al. Standards Track [Page 20] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 assume the respective state except that setting a mixing-type MAU or an AUI to standby(4) will cause the MAU to enter the shutdown state." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.7, aMAUAdminState, 30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1, acRESETMAU." ::= { ifMauEntry 4 } ifMauMediaAvailable OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), available(3), notAvailable(4), remoteFault(5), invalidSignal(6), remoteJabber(7), remoteLinkLoss(8), remoteTest(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "If the MAU is a link or fiber type (FOIRL, 10BASE-T, 10BASE-F) then this is equivalent to the link test fail state/low light function. For an AUI or a coax (including broadband) MAU this indicates whether or not loopback is detected on the DI circuit. The value of this attribute persists between packets for MAU types AUI, 10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP. The value other(1) is returned if the mediaAvailable state is not one of 2 through 6. The value unknown(2) is returned when the MAU's true state is unknown; for example, when it is being initialized. At power-up or following a reset, the value of this attribute will be unknown for AUI, coax, and 10BASE-FP MAUs. For these MAUs loopback will be tested on each transmission during which no collision is detected. If DI is receiving input when DO returns to IDL after a transmission and there has been no collision during the transmission then loopback will be detected. The value of this attribute will only change during non-collided transmissions for AUI, de Graaf, et. al. Standards Track [Page 21] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 coax, and 10BASE-FP MAUs. For 100BASE-T4, 100BASE-TX and 100BASE-FX the enumerations match the states within the respective link integrity state diagrams, fig 23- 12 and 24-15 of sections 23 and 24 of [2]. Any MAU which implements management of auto- negotiation will map remote fault indication to remote fault. The value available(3) indicates that the link, light, or loopback is normal. The value notAvailable(4) indicates link loss, low light, or no loopback. The value remoteFault(5) indicates that a fault has been detected at the remote end of the link. This value applies to 10BASE-FB, 100BASE-T4 Far End Fault Indication and non-specified remote faults from a system running auto-negotiation. The values remoteJabber(7), remoteLinkLoss(8), and remoteTest(9) should be used instead of remoteFault(5) where the reason for remote fault is identified in the remote signaling protocol. The value invalidSignal(6) indicates that an invalid signal has been received from the other end of the link. InvalidSignal(6) applies only to MAUs of type 10BASE-FB. Where an IEEE Std 802.3u-1995 clause 22 MII is present, a logic one in the remote fault bit (reference section 22.2.4.2.8 of that document) maps to the value remoteFault(5), and a logic zero in the link status bit (reference section 22.2.4.2.10 of that document) maps to the value notAvailable(4). The value notAvailable(4) takes precedence over the value remoteFault(5)." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.4, aMediaAvailable." ::= { ifMauEntry 5 } ifMauMediaAvailableStateExits OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times that de Graaf, et. al. Standards Track [Page 22] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 ifMauMediaAvailable for this MAU instance leaves the state available(3)." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.5, aLoseMediaCounter." ::= { ifMauEntry 6 } ifMauJabberState OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), noJabber(3), jabbering(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value other(1) is returned if the jabber state is not 2, 3, or 4. The agent must always return other(1) for MAU type dot3MauTypeAUI. The value unknown(2) is returned when the MAU's true state is unknown; for example, when it is being initialized. If the MAU is not jabbering the agent returns noJabber(3). This is the 'normal' state. If the MAU is in jabber state the agent returns the jabbering(4) value." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.6, aJabber.jabberFlag." ::= { ifMauEntry 7 } ifMauJabberingStateEnters OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times that mauJabberState for this MAU instance enters the state jabbering(4). For MAUs of type dot3MauTypeAUI, dot3MauType100BaseT4, dot3MauType100BaseTX, and dot3MauType100BaseFX, this counter will always indicate zero." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.6, aJabber.jabberCounter." de Graaf, et. al. Standards Track [Page 23] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 ::= { ifMauEntry 8 } ifMauFalseCarriers OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of false carrier events during IDLE in 100BASE-X links. This counter does not increment at the symbol rate. It can increment after a valid carrier completion at a maximum rate of once per 100 ms until the next carrier event. This counter increments only for MAUs of type dot3MauType100BaseT4, dot3MauType100BaseTX, and dot3MauType100BaseFX. For all other MAU types, this counter will always indicate zero. The approximate minimum time for rollover of this counter is 7.4 hours." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.10, aFalseCarriers." ::= { ifMauEntry 9 } ifMauTypeList OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the set of possible IEEE 802.3 types that the MAU could be. The value is a sum which initially takes the value zero. Then, for each type capability of this MAU, 2 raised to the power noted below is added to the sum. For example, a MAU which has the capability to be only 10BASE-T would have a value of 512 (2**9). In contrast, a MAU which supports both 10Base-T (full duplex) and 100BASE-TX (full duplex) would have a value of ((2**11) + (2**16)) or 67584. The powers of 2 assigned to the capabilities are these: Power Capability 0 other or unknown 1 AUI de Graaf, et. al. Standards Track [Page 24] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 2 10BASE-5 3 FOIRL 4 10BASE-2 5 10BASE-T duplex mode unknown 6 10BASE-FP 7 10BASE-FB 8 10BASE-FL duplex mode unknown 9 10BROAD36 10 10BASE-T half duplex mode 11 10BASE-T full duplex mode 12 10BASE-FL half duplex mode 13 10BASE-FL full duplex mode 14 100BASE-T4 15 100BASE-TX half duplex mode 16 100BASE-TX full duplex mode 17 100BASE-FX half duplex mode 18 100BASE-FX full duplex mode 19 100BASE-T2 half duplex mode 20 100BASE-T2 full duplex mode If auto-negotiation is present on this MAU, this object will map to ifMauAutoNegCapability." ::= { ifMauEntry 10 } ifMauDefaultType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the default administrative 10 or 100 Mb/s baseband MAU type, to be used in conjunction with the operational MAU type denoted by ifMauType. The set of possible values for this object is the same as the set defined for the ifMauType object. This object represents the administratively- configured type of the MAU. If auto-negotiation is not enabled or is not implemented for this MAU, the value of this object determines the operational type of the MAU. In this case, a set to this object will force the MAU into the specified operating mode. If auto-negotiation is implemented and enabled for this MAU, the operational type of the MAU is de Graaf, et. al. Standards Track [Page 25] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 determined by auto-negotiation, and the value of this object denotes the type to which the MAU will automatically revert if/when auto-negotiation is later disabled. NOTE TO IMPLEMENTORS: It may be necessary to provide for underlying hardware implementations which do not follow the exact behavior specified above. In particular, when ifMauAutoNegAdminStatus transitions from enabled to disabled, the agent implementation must ensure that the operational type of the MAU (as reported by ifMauType) correctly transitions to the value specified by this object, rather than continuing to operate at the value earlier determined by the auto-negotiation function." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID, and [IEEE 802.3 Std], 22.2.4.1.4." ::= { ifMauEntry 11 } ifMauAutoNegSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether or not auto- negotiation is supported on this MAU." ::= { ifMauEntry 12 } -- The ifJackTable applies to MAUs attached to interfaces -- which have one or more external jacks (connectors). ifJackTable OBJECT-TYPE SYNTAX SEQUENCE OF IfJackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the external jacks attached to MAUs attached to an interface." ::= { dot3IfMauBasicGroup 2 } ifJackEntry OBJECT-TYPE SYNTAX IfJackEntry MAX-ACCESS not-accessible STATUS current de Graaf, et. al. Standards Track [Page 26] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 DESCRIPTION "An entry in the table, containing information about a particular jack." INDEX { ifMauIfIndex, ifMauIndex, ifJackIndex } ::= { ifJackTable 1 } IfJackEntry ::= SEQUENCE { ifJackIndex Integer32, ifJackType JackType } ifJackIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the jack described by this entry from among other jacks attached to the same MAU." ::= { ifJackEntry 1 } ifJackType OBJECT-TYPE SYNTAX JackType MAX-ACCESS read-only STATUS current DESCRIPTION "The jack connector type, as it appears on the outside of the system." ::= { ifJackEntry 2 } -- The ifMauAutoNegTable applies to systems in which -- auto-negotiation is supported on one or more MAUs -- attached to interfaces. Note that if auto-negotiation -- is present and enabled, the ifMauType object reflects -- the result of the auto-negotiation function. ifMauAutoNegTable OBJECT-TYPE SYNTAX SEQUENCE OF IfMauAutoNegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION de Graaf, et. al. Standards Track [Page 27] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 "Configuration and status objects for the auto- negotiation function of MAUs attached to interfaces." ::= { dot3IfMauAutoNegGroup 1 } ifMauAutoNegEntry OBJECT-TYPE SYNTAX IfMauAutoNegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing configuration and status information for the auto-negotiation function of a particular MAU." INDEX { ifMauIfIndex, ifMauIndex } ::= { ifMauAutoNegTable 1 } IfMauAutoNegEntry ::= SEQUENCE { ifMauAutoNegAdminStatus INTEGER, ifMauAutoNegRemoteSignaling INTEGER, ifMauAutoNegConfig INTEGER, ifMauAutoNegCapability Integer32, ifMauAutoNegCapAdvertised Integer32, ifMauAutoNegCapReceived Integer32, ifMauAutoNegRestart INTEGER } ifMauAutoNegAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to enabled(1) will cause the interface which has the auto-negotiation signaling ability to be enabled. de Graaf, et. al. Standards Track [Page 28] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 If the value of this object is disabled(2) then the interface will act as it would if it had no auto-negotiation signaling. Under these conditions, an IEEE 802.3 MAU will immediately be forced to the state indicated by the value of the object ifMauDefaultType. NOTE TO IMPLEMENTORS: When ifMauAutoNegAdminStatus transitions from enabled to disabled, the agent implementation must ensure that the operational type of the MAU (as reported by ifMauType) correctly transitions to the value specified by the ifMauDefaultType object, rather than continuing to operate at the value earlier determined by the auto-negotiation function." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.2, aAutoNegAdminState and 30.6.1.2.2, acAutoNegAdminControl." ::= { ifMauAutoNegEntry 1 } ifMauAutoNegRemoteSignaling OBJECT-TYPE SYNTAX INTEGER { detected(1), notdetected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "A value indicating whether the remote end of the link is using auto-negotiation signaling. It takes the value detected(1) if and only if, during the previous link negotiation, FLP Bursts were received." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.3, aAutoNegRemoteSignaling." ::= { ifMauAutoNegEntry 2 } ifMauAutoNegConfig OBJECT-TYPE SYNTAX INTEGER { other(1), configuring(2), complete(3), disabled(4), parallelDetectFail(5) } MAX-ACCESS read-only STATUS current de Graaf, et. al. Standards Track [Page 29] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 DESCRIPTION "A value indicating the current status of the auto-negotiation process. The enumeration parallelDetectFail(5) maps to a failure in parallel detection as defined in 28.2.3.1 of [IEEE 802.3 Std]." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.4, aAutoNegAutoConfig." ::= { ifMauAutoNegEntry 4 } ifMauAutoNegCapability OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the set of capabilities of the local auto-negotiation entity. The value is a sum which initially takes the value zero. Then, for each capability of this interface, 2 raised to the power noted below is added to the sum. For example, an interface which has the capability to support only 100Base-TX half duplex would have a value of 32768 (2**15). In contrast, an interface which supports both 100Base-TX half duplex and and 100Base-TX full duplex would have a value of 98304 ((2**15) + (2**16)). The powers of 2 assigned to the capabilities are these: Power Capability 0 other or unknown (1-9) (reserved) 10 10BASE-T half duplex mode 11 10BASE-T full duplex mode 12 (reserved) 13 (reserved) 14 100BASE-T4 15 100BASE-TX half duplex mode 16 100BASE-TX full duplex mode 17 (reserved) 18 (reserved) 19 100BASE-T2 half duplex mode 20 100BASE-T2 full duplex mode Note that interfaces that support this MIB may de Graaf, et. al. Standards Track [Page 30] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 have capabilities that extend beyond the scope of this MIB." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.5, aAutoNegLocalTechnologyAbility." ::= { ifMauAutoNegEntry 5 } ifMauAutoNegCapAdvertised OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A value that uniquely identifies the set of capabilities advertised by the local auto- negotiation entity. Refer to ifMauAutoNegCapability for a description of the possible values of this object. Capabilities in this object that are not available in ifMauAutoNegCapability cannot be enabled." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.6, aAutoNegAdvertisedTechnologyAbility." ::= { ifMauAutoNegEntry 6 } ifMauAutoNegCapReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the set of capabilities received from the remote auto- negotiation entity. Refer to ifMauAutoNegCapability for a description of the possible values of this object. Note that interfaces that support this MIB may be attached to remote auto-negotiation entities which have capabilities beyond the scope of this MIB." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.7, aAutoNegReceivedTechnologyAbility." ::= { ifMauAutoNegEntry 7 } ifMauAutoNegRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), norestart(2) de Graaf, et. al. Standards Track [Page 31] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 } MAX-ACCESS read-write STATUS current DESCRIPTION "If the value of this object is set to restart(1) then this will force auto-negotiation to begin link renegotiation. If auto-negotiation signaling is disabled, a write to this object has no effect. Setting the value of this object to norestart(2) has no effect." REFERENCE "[IEEE 802.3 Mgt], 30.6.1.2.1, acAutoNegRestartAutoConfig." ::= { ifMauAutoNegEntry 8 } -- -- The Basic Broadband MAU Table -- broadMauBasicTable OBJECT-TYPE SYNTAX SEQUENCE OF BroadMauBasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of descriptive and status information about the broadband MAUs connected to interfaces." ::= { dot3BroadMauBasicGroup 1 } broadMauBasicEntry OBJECT-TYPE SYNTAX BroadMauBasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a single broadband MAU." INDEX { broadMauIfIndex, broadMauIndex } ::= { broadMauBasicTable 1 } BroadMauBasicEntry ::= SEQUENCE { broadMauIfIndex Integer32, broadMauIndex Integer32, broadMauXmtRcvSplitType INTEGER, de Graaf, et. al. Standards Track [Page 32] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 broadMauXmtCarrierFreq Integer32, broadMauTranslationFreq Integer32 } broadMauIfIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the interface to which the MAU described by this entry is connected." REFERENCE "Reference RFC 1213, ifIndex." ::= { broadMauBasicEntry 1 } broadMauIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the MAU connected to interface broadMauIfIndex that is described by this entry." REFERENCE "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aMAUID." ::= { broadMauBasicEntry 2 } broadMauXmtRcvSplitType OBJECT-TYPE SYNTAX INTEGER { other(1), single(2), dual(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the type of frequency multiplexing/cabling system used to separate the transmit and receive paths for the 10BROAD36 MAU. The value other(1) is returned if the split type is not either single or dual. The value single(2) indicates a single cable system. The value dual(3) indicates a dual cable de Graaf, et. al. Standards Track [Page 33] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 system, offset normally zero." REFERENCE "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aBbMAUXmitRcvSplitType." ::= { broadMauBasicEntry 3 } broadMauXmtCarrierFreq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the transmit carrier frequency of the 10BROAD36 MAU in MHz/4; that is, in units of 250 kHz." REFERENCE "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aBroadbandFrequencies.xmitCarrierFrequency." ::= { broadMauBasicEntry 4 } broadMauTranslationFreq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the translation offset frequency of the 10BROAD36 MAU in MHz/4; that is, in units of 250 kHz." REFERENCE "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aBroadbandFrequencies.translationFrequency." ::= { broadMauBasicEntry 5 } -- Notifications for use by 802.3 MAUs rpMauJabberTrap NOTIFICATION-TYPE OBJECTS { rpMauJabberState } STATUS current DESCRIPTION "This trap is sent whenever a managed repeater MAU enters the jabber state. The agent must throttle the generation of consecutive rpMauJabberTraps so that there is at least a five-second gap between them." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.3.1, nJabber de Graaf, et. al. Standards Track [Page 34] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 notification." ::= { snmpDot3MauMgt 0 1 } ifMauJabberTrap NOTIFICATION-TYPE OBJECTS { ifMauJabberState } STATUS current DESCRIPTION "This trap is sent whenever a managed interface MAU enters the jabber state. The agent must throttle the generation of consecutive ifMauJabberTraps so that there is at least a five-second gap between them." REFERENCE "[IEEE 802.3 Mgt], 30.5.1.3.1, nJabber notification." ::= { snmpDot3MauMgt 0 2 } -- Conformance information mauModConf OBJECT IDENTIFIER ::= { mauMod 1 } mauModCompls OBJECT IDENTIFIER ::= { mauModConf 1 } mauModObjGrps OBJECT IDENTIFIER ::= { mauModConf 2 } mauModNotGrps OBJECT IDENTIFIER ::= { mauModConf 3 } -- Object groups mauRpGrpBasic OBJECT-GROUP OBJECTS { rpMauGroupIndex, rpMauPortIndex, rpMauIndex, rpMauType, rpMauStatus, rpMauMediaAvailable, rpMauMediaAvailableStateExits, rpMauJabberState, rpMauJabberingStateEnters } STATUS current DESCRIPTION "Basic conformance group for MAUs attached to repeater ports. This group is also the conformance specification for RFC 1515 de Graaf, et. al. Standards Track [Page 35] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 implementations." ::= { mauModObjGrps 1 } mauRpGrp100Mbs OBJECT-GROUP OBJECTS { rpMauFalseCarriers } STATUS current DESCRIPTION "Conformance group for MAUs attached to repeater ports with 100 Mb/s capability." ::= { mauModObjGrps 2 } mauRpGrpJack OBJECT-GROUP OBJECTS { rpJackType } STATUS current DESCRIPTION "Conformance group for MAUs attached to repeater ports with managed jacks." ::= { mauModObjGrps 3 } mauIfGrpBasic OBJECT-GROUP OBJECTS { ifMauIfIndex, ifMauIndex, ifMauType, ifMauStatus, ifMauMediaAvailable, ifMauMediaAvailableStateExits, ifMauJabberState, ifMauJabberingStateEnters } STATUS current DESCRIPTION "Basic conformance group for MAUs attached to interfaces. This group also provides a conformance specification for RFC 1515 implementations." ::= { mauModObjGrps 4 } mauIfGrp100Mbs OBJECT-GROUP OBJECTS { ifMauFalseCarriers, ifMauTypeList, ifMauDefaultType, ifMauAutoNegSupported } STATUS current DESCRIPTION "Conformance group for MAUs attached to interfaces with 100 Mb/s capability." ::= { mauModObjGrps 5 } mauIfGrpJack OBJECT-GROUP de Graaf, et. al. Standards Track [Page 36] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 OBJECTS { ifJackType } STATUS current DESCRIPTION "Conformance group for MAUs attached to interfaces with managed jacks." ::= { mauModObjGrps 6 } mauIfGrpAutoNeg OBJECT-GROUP OBJECTS { ifMauAutoNegAdminStatus, ifMauAutoNegRemoteSignaling, ifMauAutoNegConfig, ifMauAutoNegCapability, ifMauAutoNegCapAdvertised, ifMauAutoNegCapReceived, ifMauAutoNegRestart } STATUS current DESCRIPTION "Conformance group for MAUs attached to interfaces with managed auto-negotiation." ::= { mauModObjGrps 7 } mauBroadBasic OBJECT-GROUP OBJECTS { broadMauIfIndex, broadMauIndex, broadMauXmtRcvSplitType, broadMauXmtCarrierFreq, broadMauTranslationFreq } STATUS current DESCRIPTION "Conformance group for broadband MAUs attached to interfaces. This group provides a conformance specification for RFC 1515 implementations." ::= { mauModObjGrps 8 } -- Notification groups rpMauNotifications NOTIFICATION-GROUP NOTIFICATIONS { rpMauJabberTrap } STATUS current DESCRIPTION "Notifications for repeater MAUs." ::= { mauModNotGrps 1 } ifMauNotifications NOTIFICATION-GROUP NOTIFICATIONS { ifMauJabberTrap } STATUS current DESCRIPTION de Graaf, et. al. Standards Track [Page 37] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 "Notifications for interface MAUs." ::= { mauModNotGrps 2 } -- Compliances mauModRpCompl MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance for MAUs attached to repeater ports." MODULE -- this module MANDATORY-GROUPS { mauRpGrpBasic } GROUP mauRpGrp100Mbs DESCRIPTION "Implementation of this optional group is recommended for MAUs which have 100Mb/s capability." GROUP mauRpGrpJack DESCRIPTION "Implementation of this optional group is recommended for MAUs which have one or more external jacks." GROUP rpMauNotifications DESCRIPTION "Implementation of this group is recommended for MAUs attached to repeater ports." ::= { mauModCompls 1 } mauModIfCompl MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance for MAUs attached to interfaces." MODULE -- this module MANDATORY-GROUPS { mauIfGrpBasic } GROUP mauIfGrp100Mbs DESCRIPTION "Implementation of this optional group is recommended for MAUs which have 100Mb/s capability." de Graaf, et. al. Standards Track [Page 38] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 GROUP mauIfGrpJack DESCRIPTION "Implementation of this optional group is recommended for MAUs which have one or more external jacks." GROUP mauIfGrpAutoNeg DESCRIPTION "Implementation of this group is mandatory for MAUs which support managed auto-negotiation." GROUP mauBroadBasic DESCRIPTION "Implementation of this group is mandatory for broadband MAUs." GROUP ifMauNotifications DESCRIPTION "Implementation of this group is recommended for MAUs attached to interfaces." ::= { mauModCompls 2 } END 4. Acknowledgements This document was produced by the IETF Hub MIB Working Group, whose efforts were greatly advanced by the contributions of the following people: Chuck Black John Flick Jeff Johnson Leon Leong Mike Lui Dave Perkins Geoff Thompson Maurice Turcotte Paul Woodruff Special thanks as well to Dave Perkins for his excellent work on the SMICng compiler, which made it easy to take advantage of the latest SNMPv2 constructs in this MIB. de Graaf, et. al. Standards Track [Page 39] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 5. References [1] IEEE 802.3/ISO 8802-3 Information processing systems - Local area networks - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications, 1993. [2] IEEE 802.3u-1995, "MAC Parameters, Physical Layer, Medium Attachment Units and Repeater for 100 Mb/s Operation, Type 100BASE-T," Sections 21 through 29, Supplement to IEEE Std 802.3, October 26, 1995. [3] IEEE 802.3u-1995, "10 & 100 Mb/s Management," Section 30, Supplement to IEEE Std 802.3, October 26, 1995. [4] de Graaf, K., D. Romascanu, D. McMaster and K. McCloghrie, "Definitions of Managed Objects for IEEE 802.3 Repeater Devices using SMIv2", RFC 2108, February 1997. [5] McCloghrie, K. and M. Rose, Editors, "Management Information Base for Network Management of TCP/IP-based internets: MIB-II", STD 17, RFC 1213, March 1991. [6] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Structure of Management Information for version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1902, January 1996. [7] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Textual Conventions for version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1903, January 1996. [8] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Conformance Statements for version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1904, January 1996. [9] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol Operations for version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1905, January 1996. [10] Case, J., M. Fedor, M. Schoffstall and J. Davin, "Simple Network Management Protocol", STD 15, RFC 1157, May 1990. [11] McMaster, D., K. McCloghrie and S. Roberts, "Definitions of Managed Objects for IEEE 802.3 Medium Attachment Units (MAUs)", RFC 1515, September 1993. de Graaf, et. al. Standards Track [Page 40] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 6. Security Considerations Certain management information defined in this MIB may be considered sensitive in some network environments. Therefore, authentication of received SNMP requests and controlled access to management information should be employed in such environments. The method for this authentication is a function of the SNMP Administrative Framework, and has not been expanded by this MIB. Several objects in this MIB allow write access. Setting these objects can have a serious effect on the operation of the network, including enabling or disabling a MAU, changing a MAU's default type, enabling, disabling or restarting autonegotiation, or modifying the capabilities that a MAU advertizes during autonegotiation. It is recommended that implementers seriously consider whether set operations should be allowed without providing, at a minimum, authentication of request origin. 7. Authors' Addresses Kathryn de Graaf 3Com Corporation 118 Turnpike Rd. Southborough, MA 01772 USA Phone: (508)229-1627 Fax: (508)490-5882 EMail: kdegraaf@isd.3com.com Dan Romascanu Madge Networks (Israel) Ltd. Atidim Technology Park, Bldg. 3 Tel Aviv 61131, Israel Phone: 972-3-6458414, 6458458 Fax: 972-3-6487146 EMail: dromasca@madge.com Donna McMaster Cisco Systems Inc. 170 West Tasman Drive San Jose, CA 95134 Phone:: (408) 526-5260 EMail: mcmaster@cisco.com de Graaf, et. al. Standards Track [Page 41] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 Keith McCloghrie Cisco Systems Inc. 170 West Tasman Drive San Jose, CA 95134 Phone: (408) 526-5260 EMail: kzm@cisco.com Sam Roberts Farallon Computing, Inc. 2470 Mariner Square Loop Alameda, CA 94501-1010 Phone:: (510) 814-5215 EMail: sroberts@farallon.com de Graaf, et. al. Standards Track [Page 42] RFC 2239 Managed Objects for IEEE 802.3 MAUs November 1997 8. Full Copyright Statement Copyright (C) The Internet Society (1997). All Rights Reserved. This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English. The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns. This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. de Graaf, et. al. Standards Track [Page 43]