💾 Archived View for gemini.spam.works › mirrors › textfiles › computers › ASTRESEARCH › 0618.tb captured on 2022-06-12 at 06:21:41.

View Raw

More Information

⬅️ Previous capture (2020-10-31)

-=-=-=-=-=-=-

=============================================================================

AST RESEARCH, INC.         TECHNICAL BULLETIN #0618                  03-14-90

=============================================================================


                    FASTBOARD 386 AND MICROSOFT WORKS 2.0


Random system lock-ups may occur when running Microsoft Works version 2.0 on
Premium/286 systems with PHOENIX BIOS and equipped with a Fastboard 386.
This problem occurs only when running Works version 2.0, earlier versions do
not exhibit this problem.

This problem can be corrected by upgrading the Premium/286 to AST BIOS
version 2.0 or above.  Customers experiencing the above problem should
contact an AST Authorized Service Center to obtain an AST Premium/286 BIOS
Upgrade Kit, AST Part Number 500529-001.