💾 Archived View for zaibatsu.circumlunar.space › ~solderpunk › files › ata-r32.txt captured on 2022-01-08 at 14:09:45.

View Raw

More Information

⬅️ Previous capture (2020-09-24)

➡️ Next capture (2024-06-20)

-=-=-=-=-=-=-

Copies of this proposal may be purchased from:            BSR X3.221
Global Engineering, 2805 McGaw St, Irvine, CA 92714       X3T9.2/90-143
800-854-7179        714-261-1455





                   working draft proposed American National
                      Standard for Information Systems -

                             ATA (AT Attachment)

                          Rev 3.2  October 16, 1992



 
Secretariat

Computer and Business Equipment Manufacturers Association (CBEMA)

Abstract:  This standard defines an integrated bus interface between disk 
drives and host processors. It provides a common point of attachment for 
systems manufacturers, system integrators, and suppliers of intelligent 
peripherals.


draft proposed American National Standard

This is a draft proposed American National Standard of Accredited Standards 
Committee X3.  As such this is not a completed standard.  The X3T9 Technical 
Committee may modify this document as a result of comments received during 
public review and its approval as a standard.




POINTS OF CONTACT:

 John B. Lohmeyer                              I. Dal Allan
 Chairman X3T9.2                               Vice-Chairman X3T9.2
 NCR                                           ENDL
 1635 Aeroplaza Dr                             14426 Black Walnut Court
 Colorado Springs  CO 80916                    Saratoga  CA 95070

 719-596-5795 x362                             408-867-6630



An electronic copy of this document is available from the SCSI Bulletin Board 
(719-574-0424). 

This document has been prepared according to the style guide of the ISO 
(International Organization of Standards). 


If this document was printed in a 2-up form directly from the printer, NOTEs 
had to be adjusted to fit into a half-page, which may have resulted in an 
imperfect representation of the format within the NOTE. This is most likely to 
occur if a series of NOTEs are mixed in without any line separation. 




ATA was forwarded in August 1991 from X3T9.2 to X3T9 for further processing as 
an American National Standard.  X3T9 authorized a letter ballot on forwarding 
this document as a preliminary draft proposed American National Standard.

X3 authorized a Public Review of Rev 3.0 of the document as a draft proposed 
American National Standard.

This revision reflects comments received during the 4-month Public Review, and 
recommendations made by the ATA Working Group of X3T9.2. Amongst the technical 
changes included herein that differ from the Rev 3.0 document are: 

          NOP:
               Additional command

          Multiword DMA:      
               Additional timing chart
               Additions to Identify Drive
               Additions to Set Features

          SFF 44-pin:
               Additional Annex

          LBA (Logical Block Addressing):
               Additional description
               Additions to Identify Drive
               Additions to Register descriptions

All changes from Rev 3.0 are marked in bold. 

Foreword: This Foreword is not part of American National Standard X3.***-199x.

When the first IBM PC (Personal Computer) (tm) was introduced, there was no 
hard disk capability for storage. Successive generations of product resulted 
in the inclusion of a hard disk as the primary storage device. When the PC AT 
(tm) was developed, a hard disk was the key to system performance, and the 
controller interface became a de facto industry interface for the inclusion of 
hard disks in PC ATs.

The price of desktop systems has declined rapidly because of the degree of 
integration to reduce the number of components and interconnects required to 
build a product. A natural outgrowth of this integration was the inclusion of 
controller functionality into the hard disk. 

In October 1988 a number of peripheral suppliers formed the Common Access 
Method Committee to encourage an industry-wide effort to adopt a common 
software interface to dispatch input/output requests to SCSI peripherals. 
Although this was the primary objective, a secondary goal was to specify what 
is known as the AT Attachment interface. 

Suggestions for improvement of this standard will be welcome. They should be 
sent to the Computer and Business Equipment Manufacturers Association, 311 
First Street N.W., Suite 500, Washington, DC 20001.

This standard was processed and approved for submittal to ANSI by the 
Accredited Standards Committee on Information Processing Systems, X3. 
Committee approval of this standard does not necessarily imply that all 
committee members voted for its approval. At the time it approved this 
standard, the X3 Committee had the following members: 

          X3 Committee list goes here:


Subcommittee X3T9 on I/O interfaces, which reviewed this standard, had the 
following members:

          X3T9 Committee list goes here:




Task Group X3T9.2 on Lower-Level Interfaces, which completed the development 
of this standard, had the following members:

          X3T9.2 Committee list goes here:



The initial development work on this standard was done by the CAM Committee.

The membership of the CAM Committee consisted of the following organizations:

  Adaptec               Data Technology          NCR 
  AMD                   Eastman Kodak            Olivetti 
  Apple                 Emulex                   Quantum 
  AT&T Bell Labs        Fujitsu uElectronics     Scientific Micro Systems 
  Caliper               Future Domain            Seagate 
  Cambrian Systems      Hewlett Packard          Sony 
  Cipher Data           IBM                      Storage Dimensions 
  Cirrus Logic          Imprimis                 Sun Microsystems 
  Columbia Data         Interactive Systems      Syquest Technology 
  CompuAdd              JVC                      Sytron 
  Conner Peripherals    LMS OSD                  Trantor 
  Dell Computer         Maxtor                   Western Digital 
  Digital Equipment     Micropolis 
  DPT                   Miniscribe 

                           TABLE OF CONTENTS

  1.          Scope                                                     1
  1.1         Description of Clauses                                    1

  2.          References                                                1
  3.          General Description                                       1
  3.1         Structure                                                 2

  4.          Definitions and Conventions                               2
  4.1         Definitions                                               2
  4.2         Conventions                                               3

  5.          Interface Cabling Requirements                            3
  5.1         Configuration                                             3
  5.2         Addressing Considerations                                 4
  5.3         DC Cable and Connector                                    5
  5.3.1       4-Pin Power                                               5
  5.3.2       3-Pin Power                                               5
  5.3.3       Device Grounding                                          6

  5.4         I/O Connector                                             6
  5.5         I/O Cable                                                 6

  6.          Physical Interface                                        7
  6.1         Signal Conventions                                        7
  6.2         Signal Summary                                            7
  6.3         Signal Descriptions                                       9
  6.3.1       CS1FX- (Drive chip Select 0)                              9
  6.3.2       CS3FX- (Drive chip Select 1)                              9
  6.3.3       DA0-2 (Drive Address Bus)                                 10
  6.3.4       DASP- (Drive Active/Drive 1 Present)                      10
  6.3.5       DD0-DD15 (Drive Data Bus)                                 10
  6.3.6       DIOR- (Drive I/O Read)                                    10
  6.3.7       DIOW- (Drive I/O Write)                                   10
  6.3.8       DMACK- (DMA Acknowledge) (Optional)                       10
  6.3.9       DMARQ (DMA Request) (Optional)                            11
  6.3.10      INTRQ (Drive Interrupt)                                   11
  6.3.11      IOCS16- (Drive 16-bit I/O)                                11
  6.3.12      IORDY (I/O Channel Ready) (Optional)                      12
  6.3.13      PDIAG- (Passed Diagnostics)                               12
  6.3.14      RESET- (Drive Reset)                                      12
  6.3.15      SPSYNC:CSEL (Spindle Synchronization/Cable Select) 
              (Optional)                                                12
  6.3.15.1    SPSYNC (Spindle Synchronization) (Optional)               13
  6.3.15.2    CSEL (Cable Select) (Optional)                            13

  7.          Logical Interface                                         14
  7.1         General                                                   14
  7.1.1       Bit Conventions                                           14
  7.1.2       Environment                                               14

  7.2         I/O Register Descriptions                                 15
  7.2.1       Alternate Status Register                                 16
  7.2.2       Command Register                                          16
  7.2.3       Cylinder High Register                                    16
  7.2.4       Cylinder Low Register                                     17
  7.2.5       Data Register                                             17
  7.2.6       Device Control Register                                   17
  7.2.7       Drive Address Register                                    17
  7.2.8       Drive/Head Register                                       18
  7.2.9       Error Register                                            18
  7.2.10      Features Register                                         19
  7.2.11      Sector Count Register                                     19
  7.2.12      Sector Number Register                                    19
  7.2.13      Status Register                                           19

  8.          Programming Requirements                                  21
  8.1         Reset Response                                            21
  8.2         Translate Mode                                            22
  8.3         Power Conditions                                          22
  8.4         Error Posting                                             22

  9.          Command Descriptions                                      23
  9.1         Acknowledge Media Change (Removable)                      25
  9.2         Boot - Post-Boot (Removable)                              25
  9.3         Boot - Pre-Boot (Removable)                               25
  9.4         Check Power Mode                                          26
  9.5         Door Lock (Removable)                                     26
  9.6         Door Unlock (Removable)                                   26
  9.7         Execute Drive Diagnostic                                  26
  9.8         Format Track                                              27
  9.9         Identify Drive                                            28
  9.9.1       Word 1: Number of cylinders                               29
  9.9.2       Word 3: Number of heads                                   29
  9.9.3       Word 4: Number of unformatted bytes per track             29
  9.9.4       Word 5: Number of unformatted bytes per sector            30
  9.9.5       Word 6: Number of sectors per track                       30
  9.9.6       Word 10-19: Serial Number                                 30
  9.9.7       Word 20: Buffer Type                                      30
  9.9.8       Word 22: ECC bytes Available on Read/Write Long Commands  30
  9.9.9       Word 23-26: Firmware Revision                             30
  9.9.10      Word 27-46: Model Number                                  30
  9.9.11      Word 51:  PIO data transfer cycle timing mode             30
  9.9.12      Word 52:  DMA data transfer cycle timing mode             30
  9.9.13      Word 54:  Number of current cylinders                     31
  9.9.14      Word 55:  Number of current heads                         31
  9.9.15      Word 56:  Number of current sectors per track             31
  9.9.16      Word 57-58: Current capacity in sectors                   31
  9.9.17      Word 59: Multiple Sector Setting                          31
  9.9.18      Word 60-61: Total Number of User Addressable Sectors      31
  9.9.19      Word 62: Single Word DMA Transfer                         31
  9.9.20      Word 63: Multiword DMA Transfer                           31

  9.10        Idle                                                      31
  9.11        Idle Immediate                                            32
  9.12        Initialize Drive Parameters                               32
  9.13        NOP                                                       32
  9.14        Read Buffer                                               32
  9.15        Read DMA                                                  33
  9.16        Read Long                                                 33
  9.17        Read Multiple Command                                     33
  9.18        Read Sector(s)                                            34
  9.19        Read Verify Sector(s)                                     34
  9.20        Recalibrate                                               35
  9.21        Seek                                                      35
  9.22        Set Features                                              35
  9.23        Set Multiple Mode                                         36
  9.24        Sleep                                                     36
  9.25        Standby                                                   37
  9.26        Standby Immediate                                         37
  9.27        Write Buffer                                              37
  9.28        Write DMA                                                 37
  9.29        Write Long                                                37
  9.30        Write Multiple Command                                    38
  9.31        Write Same                                                38
  9.32        Write Sector(s)                                           39
  9.33        Write Verify                                              39

  10.         Protocol Overview                                         39
  10.1        PIO Data In Commands                                      40
  10.1.1      PIO Read Command                                          40
  10.1.2      PIO Read Aborted Command                                  40

  10.2        PIO Data Out Commands                                     40
  10.2.1      PIO Write Command                                         41
  10.2.2      PIO Write Aborted Command                                 41

  10.3        Non-Data Commands                                         41
  10.4        Miscellaneous Commands                                    42
  10.5        DMA Data Transfer Commands (Optional)                     42
  10.5.1      Normal DMA Transfer                                       43
  10.5.2      Aborted DMA Transfer                                      43
  10.5.3      Aborted DMA Command                                       43

  11.         Timing                                                    43
  11.1        Deskewing                                                 43
  11.2        Symbols                                                   43
  11.3        Terms                                                     44
  11.4        Data Transfers                                            45
  11.5        Power On and Hard Reset                                   48

                                   FIGURES

  FIGURE 5-1:  ATA INTERFACE TO EMBEDDED BUS PERIPHERALS                4
  FIGURE 5-2:  HOST BUS ADAPTER AND PERIPHERAL DEVICES                  4
  FIGURE 5-3:  ATA INTERFACE TO CONTROLLER AND PERIPHERAL DEVICES       4
  FIGURE 5-4:  40-PIN CONNECTOR MOUNTING                                6
  FIGURE 6-1:  Cable Select                                             14
  FIGURE 11-1:  PIO DATA TRANSFER TO/FROM DRIVE                         45
  FIGURE 11-2:  IORDY TIMING REQUIREMENTS                               46
  FIGURE 11-3:  SINGLE WORD DMA DATA TRANSFER                           46
  FIGURE 11-4:  MULTIWORD DMA DATA TRANSFER                             47
  FIGURE 11-5:  RESET SEQUENCE                                          48


                                   TABLES

  TABLE 5-1:  DC INTERFACE                                              5
  TABLE 5-2:  DC INTERFACE                                              5
  TABLE 5-3:  CABLE PARAMETERS                                          7
  TABLE 6-1:  INTERFACE SIGNALS                                         8
  TABLE 6-2:  INTERFACE SIGNALS DESCRIPTION                             9
  TABLE 7-1:  I/O PORT FUNCTIONS/SELECTION ADDRESSES                    16
  TABLE 8-1:  POWER CONDITIONS                                          22
  TABLE 8-2:  REGISTER CONTENTS                                         23
  TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 1 of 2                24
  TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 2 of 2                25

  TABLE 9-2:  DIAGNOSTIC CODES                                          27
  TABLE 9-4:  SET FEATURE REGISTER DEFINITIONS                          35
  TABLE C-1  SIGNAL ASSIGNMENTS FOR ATA                                 58

                                                                       
   Information Processing Systems --

   AT Attachment Interface


1. Scope

This standard defines the AT Attachment Interface. 

The CAM Committee was formed in October, 1988 and the first working document 
of the AT Attachment was introduced in March, 1989. 

1.1  Description of Clauses

Clause 1 contains the Scope and Purpose. 

Clause 2 contains Referenced and Related International Standards.

Clause 3 contains the General Description. 

Clause 4 contains the Glossary.

Clause 5 contains the electrical and mechanical characteristics; covering the 
interface cabling requirements of the DC, data cables and connectors. 

Clause 6 contains the signal descriptions of the AT Attachment Interface.

Clause 7 contains descriptions of the registers of the AT Attachment 
Interface.

Clause 8 describes the programming requirements of the AT Attachment 
Interface.

Clause 9 contains descriptions of the commands of the AT Attachment Interface.

Clause 10 contains an overview of the protocol of the AT Attachment Interface.

Clause 11 contains the interface timing diagrams. 

Annex A is informative. 

Annex B is informative. 

Annex C is informative. 

2. References

None.

3.  General Description

The application environment for the AT Attachment Interface is any computer 
which uses an AT Bus or 40-pin ATA interface. 

The PC AT Bus (tm) is a widely used and implemented interface for which a 
variety of peripherals have been manufactured. As a means of reducing size and 
cost, a class of products has emerged which embed the controller functionality 
in the drive. These new products utilize the AT Bus fixed disk interface 
protocol, and a subset of the AT bus. Because of their compatibility with 
existing AT hardware and software this interface quickly became a de facto 
industry standard. 

The purpose of the ATA standard is to define the de facto implementations.

Software in the Operating System dispatches I/O (Input/Output) requests via 
the AT Bus to peripherals which respond to direct commands. 

3.1  Structure

This standard relies upon specifications of the mechanical and electrical 
characteristics of the AT Bus and a subset of the AT Bus specifically 
developed for the direct attachment of peripherals. 

Also defined are the methods by which commands are directed to peripherals, 
the contents of registers and the method of data transfers. 

4.  Definitions and Conventions

4.1 Definitions

For the purpose of this standard the following definitions apply:

4.1.1 ATA (AT Attachment):  ATA defines a compatible register set and a 40-pin 
connector and its associated signals. 

4.1.2 CHS (Cylinder-Head-Sector): This term defines the addressing mode of the 
drive as being by physical address.

4.1.3 Data block: This term describes a data transfer, and is typically a 
single sector, except when declared otherwise by use of the Set Multiple 
command. 

4.1.4 DMA (Direct Memory Access): A means of data transfer between 
peripheral and host memory without processor intervention. 

4.1.5 LBA (Logical Block Address): This term defines the addressing mode of 
the drive as being by the linear mapping of sectors from 1 to n.

4.1.6 Optional:  This term describes features which are not required by the 
standard. However, if any feature defined by the standard is implemented, it 
shall be done in the same way as defined by the standard. Describing a feature 
as optional in the text is done to assist the reader. If there is a conflict 
between text and tables on a feature described as optional, the table shall be 
accepted as being correct. 

4.1.7 PIO (Programmed Input/Output): A means of data transfer that requires 
the use of the host processor.

4.1.8 Reserved:  Where this term is used for bits, bytes and fields; the bits, 
bytes and fields are set aside for future standardization, and shall be zero.

4.1.9 VU (Vendor Unique):  This term is used to describe bits, bytes, 
fields, code values and features which are not described in this standard, 
and may be used in a way that varies between vendors. 

4.2  Conventions

Certain terms used herein are the proper names of signals. These are printed 
in uppercase to avoid possible confusion with other uses of the same words; 
e.g., ATTENTION. Any lowercase uses of these words have the normal American-
English meaning. 

A number of conditions, commands, sequence parameters, events, English text, 
states or similar terms are printed with the first letter of each word in 
uppercase and the rest lowercase; e.g., In, Out, Request Status. Any lowercase 
uses of these words have the normal American-English meaning. 

The American convention of numbering is used i.e., the thousands and higher 
multiples are separated by a comma and a period is used as the decimal point. 
This is equivalent to the ISO convention of a space and comma. 

   American:          0.6                      ISO:          0,6
                  1,000                                  1 000 
              1,323,462.9                            1 323 462,9
 
5. Interface Cabling Requirements 

5.1  Configuration

This standard provides the capability of operating on the AT Bus in a daisy 
chained configuration with a second drive that operates in accordance with 
these standards. One drive (selected as Drive 0) has been referred to as the 
master in industry terms and the second (selected as Drive 1) has been 
referred to as the slave (see Figure 5-3). 

The designation as Drive 0 or Drive 1 may be made in a number of ways:

 - a switch on the drive 
 - a jumper plug on the drive 
 - use of the Cable Select (CSEL) pin

Data is transferred in parallel (8 or 16 bits) either to or from host memory 
to the drive's buffer under the direction of commands previously transferred 
from the host. The drive performs all of the operations necessary to properly 
write data to, or read data from, the disk media. Data read from the media is 
stored in the drive's buffer pending transfer to the host memory and data is 
transferred from the host memory to the drive's buffer to be written to the 
media. 

         +-----------------------------------------------------+ 
         |                                                     | 
         |                       HOST                          | 
         |                                                     | 
         +---------------^-------------------------------------+ 
                         |       ATA Interface 
                         | _____________________ 
                         |/                     | 
                  +------v--+            +------v--+  
                  | DRIVE 0 |            | DRIVE 1 |  
                  +---------+            +---------+ 

         FIGURE 5-1:  ATA INTERFACE TO EMBEDDED BUS PERIPHERALS

         +-----------------------------------------------------+ 
         |                                                     | 
         |                       HOST                          | 
         |                                                     | 
         +------+====== AT Bus ======+-------------------------+ 
                |                    |
                |       ADAPTER      |
                |                    |
                +--------^-----------+
                         |       ATA Interface 
                         | _____________________ 
                         |/                     | 
                  +------v--+            +------v--+  
                  | DRIVE 0 |            | DRIVE 1 |  
                  +---------+            +---------+ 

            FIGURE 5-2:  HOST BUS ADAPTER AND PERIPHERAL DEVICES 

         +-----------------------------------------------------+ 
         |                                                     | 
         |                       HOST                          | 
         |                                                     | 
         +---------------^-------------------------------------+ 
                         |       ATA Interface 
                  +------v-----+ 
                  |            | 
                  | CONTROLLER | 
                  |            | 
                  +-^----^---^-+ 
                    |    |   |__________________   Device Interface 
                    | ___|_________________     |  e.g. ESDI, SCSI 
                    |/   |                 |    | 
                  +-v----v--+            +-v----v--+ 
                  |  DRIVE  |            |  DRIVE  | 
                  +---------+            +---------+ 

      FIGURE 5-3:  ATA INTERFACE TO CONTROLLER AND PERIPHERAL DEVICES

5.2  Addressing Considerations

In traditional controller operation, only the selected controller receives 
commands from the host following selection. In this standard, the register 
contents go to both drives (and their embedded controllers). The host 
discriminates between the two by using the DRV bit in the Drive/Head Register.

5.3  DC Cable and Connector 

The drive receives DC power through a 4-pin or a low-power application 3-pin 
connector. 

A drive designed for 3.3V applications may be plugged into a receptacle 
designed to accept a drive designed for 5V applications, with 12V lines for 
additional power. It is not required that the drive operate, but it is 
recommended that precautions be taken to prevent damage to the drive. 

A drive designed for 5V applications may be plugged into a receptacle designed 
to accept a drive designed for 3.3V applications, with 5V lines for additional 
power. It is not anticipated that damage could occur to the drive, but it is 
likely to fail in an undetermined manner. 

5.3.1  4-Pin Power

The pin assignments are shown in Table 5-1. Recommended part numbers for the 
mating connector to 18AWG cable are shown below, but equivalent parts may be 
used. 

     Connector (4 Pin)          AMP 1-480424-0 or equivalent.
     Contacts (Loose Piece)     AMP 60619-4 or equivalent.
     Contacts (Strip)           AMP 61117-4 or equivalent.

                          TABLE 5-1:  DC INTERFACE 
                  +------------------------+------------+
                  | POWER LINE DESIGNATION | PIN NUMBER |
                  +------------------------+------------+
                  |      +12V              |    1-01    |
                  |      +12V RETURN       |    1-02    |
                  |      +5V RETURN        |    1-03    |
                  |      +5V               |    1-04    |
                  +------------------------+------------+

5.3.2  3-Pin Power

The pin assignments are shown in Table 5-2. Recommended part numbers for the 
mating connector to 18AWG cable are shown below, but equivalent parts may be 
used. 

     Connector (3 Pin)          Molex 5484 39-27-0032 or equivalent.

                          TABLE 5-2:  DC INTERFACE 
                  +------------------------+------------+
                  | POWER LINE DESIGNATION | PIN NUMBER |
                  +------------+-----------+------------+
                  |    +5V     |   +3.3V   |    1-01    |
                  |    +12V    |   +5V     |    1-02    |
                  |   Ground   |  Ground   |    1-03    |
                  +------------+-----------+------------+

5.3.3  Device Grounding 

System ground may be connected to a "quick-connect" terminal equivalent to:

     Drive Connector Terminal   AMP 61664-1 or equivalent.
     Cable Connector Terminal   AMP 62137-2 or equivalent.

Provision for tying the DC Logic ground and the chassis ground together or for 
separating these two ground planes is vendor specific. 

5.4  I/O Connector 

The I/O connector is a 40-pin connector as shown in Figure 5-4, with pin 
assignments as shown in Table 6-1. 

The connector should be keyed to prevent the possibility of installing it 
upside down. A key is provided by the removal of Pin 20. The corresponding pin 
on the cable connector should be plugged. 

The pin locations are governed by the cable plug, not the receptacle. The way 
in which the receptacle is mounted on the Printed Circuit Board affects the 
pin positions, and pin 1 should remain in the same relative position. This 
means the pin numbers of the receptacle may not reflect the conductor number 
of the plug. The header receptacle is not polarized, and all the signals are 
relative to Pin 20, which is keyed. 

By using the plug positions as primary, a straight cable can connect drives. 
As shown in Figure 5-4, conductor 1 on pin 1 of the plug has to be in the 
same relative position no matter what the receptacle numbering looks like. 
If receptacle numbering was followed, the cable would have to twist 180 
degrees between a drive with top-mounted receptacles, and a drive with 
bottom-mounted receptacles. 

        +-----------------------+
        |                      1|
        |40         20         2|
      ==+==== Circuit Board ====+==       ==+==== Circuit Board ====+==
                                            |                      1|
                                            |40         20         2|
                                            +-----------------------+
                   FIGURE 5-4:  40-PIN CONNECTOR MOUNTING

Recommended part numbers for the mating connector are shown below, but 
equivalent parts may be used. 

     Connector (40 Pin)             3M 3417-7000 or equivalent.
     Strain relief                  3M 3448-2040 or equivalent.
     Flat Cable (Stranded 28 AWG)   3M 3365-40 or equivalent.
     Flat Cable (Stranded 28 AWG)   3M 3517-40 (Shielded) or equivalent.

5.5  I/O Cable 

The cable specifications affect system integrity and the maximum length that 
can be supported in any application. 

                        TABLE 5-3:  CABLE PARAMETERS
        +--------------------------------------------+------+--------+
        | Cable length of 0.46m (18 inches) *        |  Min |   Max  |
        +--------------------------------------------+------+--------+
        | Driver IoL Sink Current for 5V operation   | 12mA |        |
        | Driver IoL Sink Current for 3.3V operation |  8mA |        |
        | Driver IoH Source Current                  |      | -400uA |
        | Cable Capacitive Loading                   |      |  200pF |
        +--------------------------------------------+------+--------+   
          * This distance may be exceeded in circumstances where the 
         characteristics of both ends of the cable can be controlled.

6.  Physical Interface

6.1  Signal Conventions

Signal names are shown in all upper case letters. Signals can be asserted 
(active, true) in either a high (more positive voltage) or low (less positive 
voltage) state. A dash character (-) at the beginning or end of a signal name 
indicates it is asserted at the low level (active low). No dash or a plus 
character (+) at the beginning or end of a signal name indicates it is 
asserted high (active high). An asserted signal may be driven high or low by 
an active circuit, or it may be allowed to be pulled to the correct state by 
the bias circuitry. 

Control signals that are asserted for one function when high and asserted for 
another function when low are named with the asserted high function name 
followed by a slash character (/), and the asserted low function name followed 
with a dash (-) e.g. BITENA/BITCLR- enables a bit when high and clears a bit 
when low. All signals are TTL compatible unless otherwise noted. Negated means 
that the signal is driven by an active circuit to the state opposite to the 
asserted state (inactive, or false) or may be simply released (in which case 
the bias circuitry pulls it inactive, or false), at the option of the 
implementor. 

Control signals that may be used for two mutually exclusive functions are 
identified with their two names separated by a colon e.g. SPSYNC:CSEL can be 
used for either the Spindle Sync or the Cable Select functions.

6.2  Signal Summary

The physical interface consists of single ended TTL compatible receivers and 
drivers communicating through a 40-conductor flat ribbon nonshielded cable 
using an asynchronous interface protocol. The pin numbers and signal names 
are shown in Table 6-1. Reserved signals shall be left unconnected. 

                       TABLE 6-1:  INTERFACE SIGNALS 
 +----------------------------------+                         +-----------+
 |         HOST  I/O                |                         | DRIVE I/O | 
 |         CONNECTOR                |                         | CONNECTOR | 
 |                                  |                         |           | 
 | HOST RESET                     1 | -----  RESET-  -------->| 1         | 
 |                                2 | -----  Ground  -------- | 2         | 
 | HOST DATA BUS BIT 7            3 |<-----  DD7  ----------->| 3         | 
 | HOST DATA BUS BIT 8            4 |<-----  DD8  ----------->| 4         | 
 | HOST DATA BUS BIT 6            5 |<-----  DD6  ----------->| 5         | 
 | HOST DATA BUS BIT 9            6 |<-----  DD9  ----------->| 6         | 
 | HOST DATA BUS BIT 5            7 |<-----  DD5  ----------->| 7         | 
 | HOST DATA BUS BIT 10           8 |<-----  DD10  ---------->| 8         | 
 | HOST DATA BUS BIT 4            9 |<-----  DD4  ----------->| 9         | 
 | HOST DATA BUS BIT 11          10 |<-----  DD11  ---------->| 10        | 
 | HOST DATA BUS BIT 3           11 |<-----  DD3  ----------->| 11        | 
 | HOST DATA BUS BIT 12          12 |<-----  DD12  ---------->| 12        | 
 | HOST DATA BUS BIT 2           13 |<-----  DD2  ----------->| 13        | 
 | HOST DATA BUS BIT 13          14 |<-----  DD13  ---------->| 14        | 
 | HOST DATA BUS BIT 1           15 |<-----  DD1  ----------->| 15        | 
 | HOST DATA BUS BIT 14          16 |<-----  DD14  ---------->| 16        | 
 | HOST DATA BUS BIT 0           17 |<-----  DD0  ----------->| 17        | 
 | HOST DATA BUS BIT 15          18 |<-----  DD15  ---------->| 18        | 
 |                               19 | -----  Ground  -------- | 19        | 
 |                               20 | -----  (keypin)  ------ | 20        | 
 | DMA REQUEST                   21 |<-----  DMARQ  --------- | 21        | 
 |                               22 | -----  Ground  -------- | 22        | 
 | HOST I/O WRITE                23 | -----  DIOW-  --------->| 23        | 
 |                               24 | -----  Ground  -------- | 24        | 
 | HOST I/O READ                 25 | -----  DIOR-  --------->| 25        | 
 |                               26 | -----  Ground  -------- | 26        | 
 | I/O CHANNEL READY             27 |<-----  IORDY  --------- | 27        | 
 | SPINDLE SYNC or CABLE SELECT  28 |*---- SPSYNC:CSEL  -----*| 28        | 
 | DMA ACKNOWLEDGE               29 | -----  DMACK-  -------->| 29        | 
 |                               30 | -----  Ground  -------- | 30        | 
 | HOST INTERRUPT REQUEST        31 |<-----  INTRQ  --------- | 31        | 
 | HOST 16 BIT I/O               32 |<-----  IOCS16-  ------- | 32        | 
 | HOST ADDRESS BUS BIT 1        33 | -----  DA1  ----------->| 33        | 
 | PASSED DIAGNOSTICS            34 |*-----  PDIAG-  --------*| 34        | 
 | HOST ADDRESS BUS BIT 0        35 | -----  DAO  ----------->| 35        | 
 | HOST ADDRESS BUS BIT 2        36 | -----  DA2  ----------->| 36        | 
 | HOST CHIP SELECT 0            37 | -----  CS1FX-  -------->| 37        | 
 | HOST CHIP SELECT 1            38 | -----  CS3FX-  -------->| 38        | 
 | DRIVE ACTIVE/DRIVE 1 PRESENT  39 |<-----  DASP-  ---------*| 39        | 
 |                               40 | -----  Ground  -------- | 40        | 
 +----------------------------------+                         +-----------+

                     * Drive Intercommunication Signals

       +---HOST---+       +-Drive 0-+                    +-Drive 1-+
       |       28 | ----->| 28   28 |<-- SPSYNC:CSEL  -->| 28      |
       |       34 | ----- | 34   34 |<----- PDIAG-  ---- | 34      |
       |       39 |<----- | 39   39 |<----- DASP-  ----- | 39      |
       +----------+       +---------+                    +---------+ 

6.3  Signal Descriptions

The interface signals and pins are described in more detail than shown in 
Table 6-1. The signals are listed according to function, rather than in 
numerical connector pin order. Table 6-2 lists signal name mnemonic, connector 
pin number, whether input to (I) or output from (O) the drive, and full signal 
name. 

                 TABLE 6-2:  INTERFACE SIGNALS DESCRIPTION 
 +--------+----+-----+
 | Signal | Pin| I/O |
 +--------+----+-----+-----------------------------------------------------+
 | CS1FX- | 37 |  I  | Drive chip Select 0                                 |
 | CS3FX- | 38 |  I  | Drive chip Select 1                                 |
 | DA0    | 35 |  I  | Drive Address Bus - Bit 0                           |
 | DA1    | 33 |  I  |                   - Bit 1                           |
 | DA2    | 36 |  I  |                   - Bit 2                           |
 | DASP-  | 39 | I/O | Drive Active/Drive 1 Present                        |
 | DD0    | 17 | I/O | Drive Data Bus - Bit 0                              |
 | DD1    | 15 | I/O |                - Bit 1                              | 
 | DD2    | 13 | I/O |                - Bit 2                              |
 | DD3    | 11 | I/O |                - Bit 3                              |
 | DD4    |  9 | I/O |                - Bit 4                              |
 | DD5    |  7 | I/O |                - Bit 5                              |
 | DD6    |  5 | I/O |                - Bit 6                              |
 | DD7    |  3 | I/O |                - Bit 7                              |
 | DD8    |  4 | I/O |                - Bit 8                              |
 | DD9    |  6 | I/O |                - Bit 9                              |
 | DD10   |  8 | I/O |                - Bit 10                             |
 | DD11   | 10 | I/O |                - Bit 11                             |
 | DD12   | 12 | I/O |                - Bit 12                             |
 | DD13   | 14 | I/O |                - Bit 13                             |
 | DD14   | 16 | I/O |                - Bit 14                             |
 | DD15   | 18 | I/O |                - Bit 15                             |
 | DIOR-  | 25 |  I  | Drive I/O Read                                      |
 | DIOW-  | 23 |  I  | Drive I/O Write                                     |
 | DMACK- | 29 |  I  | DMA Acknowledge                                     |
 | DMARQ  | 21 |  O  | DMA Request                                         |
 | INTRQ  | 31 |  O  | Drive Interrupt                                     |
 | IOCS16-| 32 |  O  | Drive 16-bit I/O                                    |
 | IORDY  | 27 |  O  | I/O Channel Ready                                   |
 | PDIAG- | 34 | I/O | Passed Diagnostics                                  |
 | RESET- |  1 |  I  | Drive Reset                                         | 
 | SPSYNC:| 28 |  -  | Spindle Sync                                        |
 | CSEL   | 28 |  -  | Cable Select                                        |
 | keypin | 20 |  -  | Pin used for keying the interface connector.        |
 +--------+----+-----+-----------------------------------------------------+

6.3.1 CS1FX- (Drive chip Select 0)

This is the chip select signal decoded from the host address bus used to 
select the Command Block Registers. 

6.3.2 CS3FX- (Drive chip Select 1)

This is the chip select signal decoded from the host address bus used to 
select the Control Block Registers. 

6.3.3 DA0-2 (Drive Address Bus) 

This is the 3-bit binary coded address asserted by the host to access a 
register or data port in the drive.  

6.3.4 DASP- (Drive Active/Drive 1 Present)

This is a time-multiplexed signal which indicates that a drive is active, or 
that Drive 1 is present. This signal shall be an open collector output and 
each drive shall have a 10K ohm pull-up resistor.

During power on initialization or after RESET- is negated, DASP- shall be 
asserted by Drive 1 within 400 msec to indicate that Drive 1 is present. 

Drive 0 shall allow up to 450 msec for Drive 1 to assert DASP-. If Drive 1 is 
not present, Drive 0 may assert DASP- to drive an activity LED. 

DASP- shall be negated following acceptance of the first valid command by 
Drive 1 or after 31 seconds, whichever comes first. 

Any time after negation of DASP-, either drive may assert DASP- to indicate 
that a drive is active. 

  NOTE: Prior to the development of this standard, products were introduced 
        which did not time multiplex DASP-. Some used two jumpers to indicate 
        to Drive 0 whether Drive 1 was present. If such a drive is jumpered to 
        indicate Drive 1 is present it should work successfully with a Drive 1 
        which complies with this standard. If installed as Drive 1, such a 
        drive may not work successfully because it may not assert DASP- for a 
        long enough period to be recognized. However, it would assert DASP- 
        to indicate that the drive is active. 

6.3.5 DD0-DD15 (Drive Data Bus)

This is an 8- or 16-bit bidirectional data bus between the host and the drive. 
The lower 8 bits are used for 8-bit transfers e.g. registers, ECC bytes and, 
if the drive supports the Features Register capability to enable 8-bit-only 
data transfers (see 9.21).

6.3.6 DIOR- (Drive I/O Read)

This is the Read strobe signal. The falling edge of DIOR- enables data from a 
register or the data port of the drive onto the host data bus, DD0-DD7 or DD0-
DD15. The rising edge of DIOR- latches data at the host. 

6.3.7 DIOW- (Drive I/O Write)

This is the Write strobe signal. The rising edge of DIOW- clocks data from the 
host data bus, DD0-DD7 or DD0-DD15, into a register or the data port of the 
drive. 

6.3.8 DMACK- (DMA Acknowledge) (Optional)

This signal shall be used by the host in response to DMARQ to either 
acknowledge that data has been accepted, or that data is available.

6.3.9 DMARQ (DMA Request) (Optional)

This signal, used for DMA data transfers between host and drive, shall be 
asserted by the drive when it is ready to transfer data to or from the host. 
The direction of data transfer is controlled by DIOR- and DIOW-. This signal 
is used in a handshake manner with DMACK- i.e. the drive shall wait until the 
host asserts DMACK- before negating DMARQ, and re-asserting DMARQ if there is 
more data to transfer. 

When a DMA operation is enabled, IOCS16-, CS1FX- and CS3FX- shall not be 
asserted and transfers shall be 16-bits wide. 

  NOTE: ATA products with DMA capability require a pull-down resistor on this 
        signal to prevent spurious data transfers. This resistor may affect 
        driver requirements for drives sharing this signal in systems with 
        unbuffered ATA signals. 

6.3.10 INTRQ (Drive Interrupt)

This signal is used to interrupt the host system. INTRQ is asserted only when 
the drive has a pending interrupt, the drive is selected, and the host has 
cleared nIEN in the Device Control Register. If nIEN=1, or the drive is not 
selected, this output is in a high impedance state, regardless of the presence 
or absence of a pending interrupt. 

INTRQ shall be negated by:

 - assertion of RESET- or
 - the setting of SRST of the Device Control Register, or 
 - the host writing the Command Register or
 - the host reading the Status Register 

  NOTE: Some drives may negate INTRQ on a PIO data transfer completion, except 
        on a single sector read or on the last sector of a multi-sector read.

On PIO transfers, INTRQ is asserted at the beginning of each data block to be 
transferred. A data block is typically a single sector, except when 
declared otherwise by use of the Set Multiple command. An exception occurs on 
Format Track, Write Sector(s), Write Buffer and Write Long commands - INTRQ 
shall not be asserted at the beginning of the first data block to be 
transferred.

On DMA transfers, INTRQ is asserted only once, after the command has 
completed. 

6.3.11 IOCS16- (Drive 16-bit I/O)

Except for DMA transfers, IOCS16- indicates to the host system that the 16-bit 
data port has been addressed and that the drive is prepared to send or receive 
a 16-bit data word. This shall be an open collector output. 

 - When transferring in PIO mode, If IOCS16- is not asserted, transfers shall 
   be 8-bit using DD0-7. 
 - When transferring in PIO mode, if IOCS16- is asserted, transfers shall be 
   16-bit using DD0-15. 
   for 16-bit data transfers. 
 - When transferring in DMA mode, the host shall use a 16-bit DMA channel and 
   IOCS16- shall not be asserted. 

6.3.12 IORDY (I/O Channel Ready) (Optional)

This signal is negated to extend the host transfer cycle of any host register 
access (Read or Write) when the drive is not ready to respond to a data 
transfer request. When IORDY is not negated, IORDY shall be in a high 
impedance state. 

6.3.13 PDIAG- (Passed Diagnostics)

This signal shall be asserted by Drive 1 to indicate to Drive 0 that it has 
completed diagnostics. A 10K ohm pull-up resistor shall be used on this signal 
by each drive. 

Following a power on reset, software reset or RESET-, Drive 1 shall negate 
PDIAG- within 1 msec (to indicate to Drive 0 that it is busy). Drive 1 shall 
then assert PDIAG- within 30 seconds to indicate that it is no longer busy, 
and is able to provide status. After the assertion of PDIAG-, Drive 1 may be 
unable to accept commands until it has finished its reset procedure and is 
Ready (DRDY=1). 

Following the receipt of a valid Execute Drive Diagnostics command, Drive 
1 shall negate PDIAG- within 1 msec to indicate to Drive 0 that it is busy 
and has not yet passed its drive diagnostics. If Drive 1 is present then 
Drive 0 shall wait for up to 5 seconds from the receipt of a valid Execute 
Drive Diagnostics command for Drive 1 to assert PDIAG-. Drive 1 should 
clear BSY before asserting PDIAG-, as PDIAG- is used to indicate that 
Drive 1 has passed its diagnostics and is ready to post status.

If DASP- was not asserted by Drive 1 during reset initialization, Drive 0 
shall post its own status immediately after it completes diagnostics, and 
clear the Drive 1 Status Register to 00h. Drive 0 may be unable to accept 
commands until it has finished its reset procedure and is Ready (DRDY=1). 

6.3.14 RESET- (Drive Reset)

This signal from the host system shall be asserted for at least 25 usec after 
voltage levels have stabilized during power on and negated thereafter unless 
some event requires that the drive(s) be reset following power on.

6.3.15  SPSYNC:CSEL (Spindle Synchronization/Cable Select) (Optional) 

This signal shall have a 10K ohm pull-up resistor.

This is a dual purpose signal and either or both functions may be implemented. 
If both functions are implemented then they cannot be active concurrently: the 
choice as to which is active is made by a vendor-defined switch. 

All drives connected to the same cable should have the same function active at 
the same time. If SPSYNC and CSEL are mixed on the same cable, then drive 
behaviour is undefined. 

Prior to the introduction of this standard, this signal was defined as DALE 
(Drive Address Latch Enable), and used for an address valid indication from 
the host system. If used, the host address and chip selects, DAO through DA2, 
CS1FX-, and CS3FX- were valid at the negation of this signal and remained 
valid while DALE was negated, therefore, the drive did not need to latch these 
signals with DALE. 

6.3.15.1  SPSYNC (Spindle Synchronization) (Optional) 

This signal may be either input or output to the drive depending on a vendor-
defined switch. If a drive is set to Master the signal is output, and if a 
drive is set to slave the signal is input.

There is no requirement that each drive implementation be plug-compatible to 
the extent that a multiple vendor drive subsystem be operable. Mix and match 
of different manufacturers drives is unlikely because rpm, sync fields, sync 
bytes etc need to be virtually identical. However, if drives are designed to 
match the following recommendation, controllers can operate drives with a 
single implementation. 

There can only be one master drive at a time in a configuration. The host or 
the drive designated as master can generate SPSYNC at least once per rotation, 
but may be at a higher frequency. 

SPSYNC received by a drive is used as the synchronization signal to lock the 
spindles in step. The time to achieve synchronization varies, and is indicated 
by the drive setting DRDY i.e. if the drive does not achieve synchronization 
following power on or a reset, it shall not set DRDY. 

A master drive or the host generates SPSYNC and transmits it. 

A slave drive does not generate SPSYNC and is responsible to synchronize its 
index to SPSYNC.

If a drive does not support synchronization, it shall ignore SPSYNC. 

In the event that a drive previously synchronized loses synchronization, but 
is otherwise operational, it does not clear DRDY.

6.3.15.2  CSEL (Cable Select) (Optional) 

The drive is configured as either Drive 0 or Drive 1 depending upon the value 
of CSEL:

 - If CSEL is grounded then the drive address is 0
 - If CSEL is open then the drive address is 1

Special cabling can be used by the system manufacturer to selectively ground 
CSEL e.g. CSEL of Drive 0 is connected to the CSEL conductor in the cable, and 
is grounded, thus allowing the drive to recognize itself as Drive 0. CSEL of 
Drive 1 is not connected to CSEL because the conductor is removed, thus the 
drive can recognize itself as Drive 1. 

              ______ CSEL Conductor _________________________      
             |                            |                Open
             |Ground                      |                  | 
          +------+                   +---------+        +---------+
          | Host |                   | Drive 0 |        | Drive 1 |
          +------+                   +---------+        +---------+

              ______ CSEL Conductor _________________________
             |                          Open                 |  
             |Ground                      |                  |
          +------+                   +---------+        +---------+
          | Host |                   | Drive 1 |        | Drive 0 |
          +------+                   +---------+        +---------+

                          FIGURE 6-1:  Cable Select 

7.  Logical Interface 

7.1  General 

7.1.1  Bit Conventions

Bit names are shown in all upper case letters except where a lower case n 
precedes a bit name. This indicates that when nBIT=0 (bit is zero) the action 
is true and when nBIT=1 (bit is one) the action is false. If there is no 
preceding n, then when BIT=1 it is true, and when BIT=0 it is false. 

A bit can be set to one or cleared to zero and polarity influences whether it 
is to be interpreted as true or false:

          True      BIT=1       nBIT=0 
          False     BIT=0       nBIT=1 

7.1.2  Environment

The drives using this interface shall be programmed by the host computer to 
perform commands and return status to the host at command completion. When two 
drives are daisy chained on the interface, commands are written in parallel to 
both drives, and for all except the Execute Diagnostics command, only the 
selected drive executes the command. On an Execute Diagnostics command 
addressed to Drive 0, both drives shall execute the command, and Drive 1 shall 
post its status to Drive 0 via PDIAG-.

Drives are selected by the DRV bit in the Drive/Head Register (see 7.2.8), and 
by a jumper or switch on the drive designating it as either a Drive 0 or as 
Drive 1. When DRV=0, Drive 0 is selected. When DRV=1, Drive 1 is selected. 
When drives are daisy chained, one shall be set as Drive 0 and the other as 
Drive 1. When a single drive is attached to the interface it shall be set as 
Drive 0. 

Prior to the adoption of this standard, some drives may have provided jumpers 
to indicate Drive 0 with no Drive 1 present, or Drive 0 with Drive 1 present.

Throughout this document, drive selection always refers to the state of the 
DRV bit, the position of the Drive 0/Drive 1 jumper or switch, or use of the 
CSEL pin. 

A drive can operate in either of two addressing modes, CHS or LBA, on a 
command by command basis. A drive which can support LBA mode indicates this in 
the Identify Drive Information. If the host selects LBA mode in the Drive/Head 
register, Sector Number, Cylinder Low, Cylinder High and HS3-HS0 of the 
Drive/Head Register contains the zero based-LBA.

In LBA mode, the sectors on the drive are assumed to be linearly mapped with 
an Inital definition of:

        LBA 0 = Cylinder 0/Head 0/Sector 1.

Irrespective of translate mode geometry set by the host, the LBA address of a 
given sector does not change:

  LBA = [ (Cylinder * No of Heads + Heads) * Sectors/Track ] + (Sector-1) 

7.2  I/O Register Descriptions 

Communication to or from the drive is through an I/O Register that routes the 
input or output data to or from registers (selected) by a code on signals from 
the host (CS1FX-, CS3FX-, DA2, DA1, DA0, DIOR- and DIOW-). 

The Command Block Registers are used for sending commands to the drive or 
posting status from the drive. 

The Control Block Registers are used for drive control and to post alternate 
status. 

Table 7-1 lists these registers and the addresses that select them. 

Logic conventions are:   A = signal asserted
                         N = signal negated
                         x = does not matter which it is

            TABLE 7-1:  I/O PORT FUNCTIONS/SELECTION ADDRESSES 
 +-------------------------------+-----------------------------------------+
 |         Addresses             |                 Functions               |
 |CS1FX-|CS3FX-| DA2 | DA1 | DA0 |    READ (DIOR-)     |   WRITE (DIOW-)   |
 +------+------+-----+-----+-----+---------------------+-------------------+
 |                                        Control Block Registers          |
 +------+------+-----+-----+-----+---------------------+-------------------+
 |  N   |  N   |  x  |  x  |  x  | Data Bus High Imped | Not used          |
 |  N   |  A   |  0  |  x  |  X  | Data Bus High Imped | Not used          |
 |  N   |  A   |  1  |  0  |  x  | Data Bus High Imped | Not used          |
 |  N   |  A   |  1  |  1  |  0  | Alternate Status    | Device Control    | 
 |  N   |  A   |  1  |  1  |  1  | Drive Address       | Not used          |
 +------+------+-----+-----+-----+---------------------+-------------------+
 |                                        Command Block Registers          |
 +------+------+-----+-----+-----+---------------------+-------------------+
 |  A   |  N   |  0  |  0  |  0  | Data                | Data              |
 |  A   |  N   |  0  |  0  |  1  | Error Register      | Features          |
 |  A   |  N   |  0  |  1  |  0  | Sector Count        | Sector Count      |
 |  A   |  N   |  0  |  1  |  1  | Sector Number       | Sector Number     | 
 |  A   |  N   |  0  |  1  |  1  | * LBA Bits  0- 7    | * LBA Bits  0- 7  |
 |  A   |  N   |  1  |  0  |  0  | Cylinder Low        | Cylinder Low      |
 |  A   |  N   |  1  |  0  |  0  | * LBA Bits  8-15    | * LBA Bits  8-15  |
 |  A   |  N   |  1  |  0  |  1  | Cylinder High       | Cylinder High     | 
 |  A   |  N   |  1  |  0  |  1  | * LBA Bits 16-23    | * LBA Bits 16-23  |
 |  A   |  N   |  1  |  1  |  0  | Drive/Head          | Drive/Head        |
 |  A   |  N   |  1  |  1  |  0  | * LBA Bits 24-27    | * LBA Bits 24-27  |
 |  A   |  N   |  1  |  1  |  1  | Status              | Command           |
 |  A   |  A   |  x  |  x  |  x  | Invalid Address     | Invalid Address   |
 +------+------+-----+-----+-----+---------------------+-------------------+
                      * Mapping of registers in LBA Mode

7.2.1  Alternate Status Register

This register contains the same information as the Status Register in the 
command block. The only difference being that reading this register does not 
imply interrupt acknowledge or clear a pending interrupt. 

         7       6       5       4       3       2       1       0 
     +-------+-------+-------+-------+-------+-------+-------+-------+
     |  BSY  | DRDY  |  DWF  |  DSC  |  DRQ  | CORR  |  IDX  |  ERR  | 
     +-------+-------+-------+-------+-------+-------+-------+-------+

See 7.2.13 for definitions of the bits in this register. 

7.2.2  Command Register 

This register contains the command code being sent to the drive. Command 
execution begins immediately after this register is written. The executable 
commands, the command codes, and the necessary parameters for each command are 
listed in Table 9-1.

7.2.3  Cylinder High Register

This register contains the high order bits of the starting cylinder address 
for any disk access. At the end of the command, this register is updated to 
reflect the current cylinder number. The most significant bits of the cylinder 
address shall be loaded into the cylinder high Register. 

In LBA Mode this register contains Bits 16-23. At the end of the command, this 
register is updated to reflect the current LBA Bits 16-23.

  NOTE: Prior to the introduction of this standard, only the lower 2 bits of 
        this register were valid, limiting cylinder address to 10 bits i.e. 
        1,024 cylinders.

7.2.4  Cylinder Low Register

This register contains the low order 8 bits of the starting cylinder address 
for any disk access. At the end of the command, this register is updated to 
reflect the current cylinder number. 

In LBA Mode this register contains Bits 8-15. At the end of the command, this 
register is updated to reflect the current LBA Bits 8-15.

7.2.5  Data Register

This 16-bit register is used to transfer data blocks between the device data 
buffer and the host. It is also the register through which sector information 
is transferred on a Format Track command. Data transfers may be either PIO or 
DMA. 

7.2.6  Device Control Register

The bits in this register are as follows: 

         7       6       5       4       3       2       1       0 
     +-------+-------+-------+-------+-------+-------+-------+-------+
     |   x   |   x   |   x   |   x   |   1   | SRST  |  nIEN |   0   | 
     +-------+-------+-------+-------+-------+-------+-------+-------+

 - SRST is the host software reset bit. The drive is held reset when this bit 
   is set. If two disk drives are daisy chained on the interface, this bit 
   resets both simultaneously. Drive 1 is not required to execute the DASP- 
   handshake procedure.
 - nIEN is the enable bit for the drive interrupt to the host. When nIEN=0, 
   and the drive is selected, INTRQ shall be enabled through a tri-state 
   buffer. When nIEN=1, or the drive is not selected, the INTRQ signal shall 
   be in a high impedance state. 

7.2.7  Drive Address Register

This register contains the inverted drive select and head select addresses of 
the currently selected drive. The bits in this register are as follows: 

         7       6       5       4       3       2       1       0 
     +-------+-------+-------+-------+-------+-------+-------+-------+
     |  HiZ  |  nWTG |  nHS3 |  nHS2 |  nHS1 |  nHS0 |  nDS1 |  nDS0 | 
     +-------+-------+-------+-------+-------+-------+-------+-------+

 - HiZ shall always be in a high impedance state. 
 - nWTG is the Write Gate bit. When writing to the disk drive is in progress, 
   nWTG=0.
 - nHS3 through nHS0 are the one's complement of the binary coded address of 
   the currently selected head. For example, if nHS3 through nHS0 are 1100b, 
   respectively, head 3 is selected. nHS3 is the most significant bit. 
 - nDS1 is the drive select bit for drive 1. When drive 1 is selected and 
   active, nDS1=0. 
 - nDS0 is the drive select bit for drive 0. When drive 0 is selected and 
   active, nDS0=0.

  NOTE: Care should be used when interpreting these bits, as they do not 
        always represent the expected status of drive operations at the 
        instant the status was put into this register. This is because of the 
        use of cacheing, translate mode and the Drive 0/Drive 1 concept with 
        each drive having its own embedded controller. 

7.2.8  Drive/Head Register

This register contains the drive and head numbers. The contents of this 
register define the number of heads minus 1, when executing an Initialize 
Drive Parameters command. 

         7       6       5       4       3       2       1       0 
     +-------+-------+-------+-------+-------+-------+-------+-------+
     |   1   |   L   |   1   |  DRV  |  HS3  |  HS2  |  HS1  |  HS0  | 
     +-------+-------+-------+-------+-------+-------+-------+-------+

 - L is the binary encoded address mode select. When L=0, addressing is by CHS 
   mode. When L=1, addressing is by LBA mode. 
 - DRV is the binary encoded drive select number. When DRV=0, Drive 0 is 
   selected. When DRV=1, Drive 1 is selected.
 - If L=0, HS3 through HS0 contain the binary coded address of the head to be 
   selected e.g. if HS3 through HS0 are 0011b, respectively, head 3 will be 
   selected. HS3 is the most significant bit. At command completion, these 
   bits are updated to reflect the currently selected head. 
   If L=1, HS3 through HS0 contain bits 24-27 of the LBA. At command 
   completion, these bits are updated to reflect the current LBA bits 24-27. 

7.2.9  Error Register 

This register contains status from the last command executed by the drive or a 
Diagnostic Code. 

At the completion of any command except Execute Drive Diagnostic, the contents 
of this register are valid when ERR=1 in the Status Register. 

Following a power on, a reset, or completion of an Execute Drive Diagnostic 
command, this register contains a Diagnostic Code (see Table 9-2). 

         7       6       5       4       3       2       1       0 
     +-------+-------+-------+-------+-------+-------+-------+-------+
     | BBK   |  UNC  |  MC   |  IDNF |  MCR  | ABRT  | TK0NF |  AMNF |
     +-------+-------+-------+-------+-------+-------+-------+-------+

 - BBK (Bad Block Detected) indicates a bad block mark was detected in the 
   requested sector's ID field. 
 - UNC (Uncorrectable Data Error) indicates an uncorrectable data error has 
   been encountered. 
 - MC (Media Changed) indicates that the removable media has been changed i.e. 
   there has been a change in the ability to access the media.
 - IDNF (ID Not Found) indicates the requested sector's ID field could not be 
   found. 
 - ABRT (Aborted Command) indicates the requested command has been aborted due 
   to a drive status error (Not Ready, Write Fault, etc.) or because the 
   command code is invalid. 
 - MCR (Media Change Requested) indicates that the release latch on a 
   removable media drive has been pressed. This means that the user wishes to 
   remove the media and requires an action of some kind e.g. have software 
   issue a Media Eject or Door Unlock command. 
 - TK0NF (Track 0 Not Found) indicates track 0 has not been found during a 
   Recalibrate command. 
 - AMNF (Address Mark Not Found) indicates the data address mark has not been 
   found after finding the correct ID field. 

7.2.10  Features Register

This register is command specific and may be used to enable and disable 
features of the interface e.g. by the Set Features Command to enable and 
disable cacheing. 

This register may be ignored by some drives. 

Some hosts, based on definitions prior to the completion of this standard, set 
values in this register to designate a recommended Write Precompensation 
Cylinder value. 

7.2.11  Sector Count Register

This register contains the number of sectors of data requested to be 
transferred on a read or write operation between the host and the drive. If 
the value in this register is zero, a count of 256 sectors is specified. 

If this register is zero at command completion, the command was successful. If 
not successfully completed, the register contains the number of sectors which 
need to be transferred in order to complete the request.

The contents of this register may be defined otherwise on some commands e.g. 
Initialize Drive Parameters, Format Track or Write Same commands. 

7.2.12  Sector Number Register

This register contains the starting sector number for any disk data access for 
the subsequent command. The sector number may be from 1 to the maximum number 
of sectors per track. 

In LBA Mode this register contains Bits 0-7. At the end of the command, this 
register is updated to reflect the current LBA Bits 0-7.

See the command descriptions for contents of the register at command 
completion (whether successful or unsuccessful).

7.2.13  Status Register

This register contains the drive status. The contents of this register are 
updated at the completion of each command. When BSY is cleared, the other bits 
in this register shall be valid within 400 nsec. If BSY=1, no other bits in 
this register are valid. If the host reads this register when an interrupt is 
pending, it is considered to be the interrupt acknowledge. Any pending 
interrupt is cleared whenever this register is read. 

  NOTE: If Drive 1 is not detected as being present, Drive 0 clears the Drive 
        1 Status Register to 00h (indicating that the drive is Not Ready).

         7       6       5       4       3       2       1       0 
     +-------+-------+-------+-------+-------+-------+-------+-------+
     |  BSY  | DRDY  |  DWF  |  DSC  |  DRQ  | CORR  |  IDX  |  ERR  | 
     +-------+-------+-------+-------+-------+-------+-------+-------+

  NOTE: Prior to the definition of this standard, DRDY and DSC were unlatched 
        real time signals. 

 - BSY (Busy) is set whenever the drive has access to the Command Block 
   Registers. The host should not access the Command Block Register when 
   BSY=1. When BSY=1, a read of any Command Block Register shall return the 
   contents of the Status Register. This bit is set by the drive (which may be 
   able to respond at times when the media cannot be accessed) under the 
   following circumstances: 
   a) within 400 nsec after the negation of RESET- or after SRST has been set 
      in the Device Control Register. Following acceptance of a reset it is 
      recommended that BSY be set for no longer than 30 seconds by Drive 1 and 
      no longer than 31 seconds by Drive 0.
   b) within 400 nsec of a host write of the Command Register with a Read, 
      Read Long, Read Buffer, Seek, Recalibrate, Initialize Drive Parameters, 
      Read Verify, Identify Drive, or Execute Drive Diagnostic command. 
   c) within 5 usecs following transfer of 512 bytes of data during execution 
      of a Write, Format Track, or Write Buffer command, or 512 bytes of data 
      and the appropriate number of ECC bytes during the execution of a Write 
      Long command. 
 - DRDY (Drive Ready) indicates that the drive is capable of responding to a 
   command. When there is an error, this bit is not changed until the Status 
   Register is read by the host, at which time the bit again indicates the 
   current readiness of the drive. This bit shall be cleared at power on and 
   remain cleared until the drive is ready to accept a command. 
 - DWF (Drive Write Fault) indicates the current write fault status. When an 
   error occurs, this bit shall not be changed until the Status Register is 
   read by the host, at which time the bit again indicates the current write 
   fault status. 
 - DSC (Drive Seek Complete) indicates that the drive heads are settled over a 
   track. When an error occurs, this bit shall not be changed until the Status 
   Register is read by the host, at which time the bit again indicates the 
   current Seek Complete status. 
 - DRQ (Data Request) indicates that the drive is ready to transfer a word or 
   byte of data between the host and the drive.
 - CORR (Corrected Data) indicates that a correctable data error was 
   encountered and the data has been corrected. This condition does not 
   terminate a data transfer. 
 - IDX (Index) is set once per disk revolution. 
 - ERR (Error) indicates that an error occurred during execution of the 
   previous command. The bits in the Error Register have additional 
   information regarding the cause of the error. 

8.  Programming Requirements

8.1  Reset Response 

A reset is accepted within 400 nsec after the negation of RESET- or within 400 
nsec after SRST has been set in the Device Control Register. 

When the drive is reset by RESET-, Drive 1 shall indicate it is present by 
asserting DASP- within 400 msec, and DASP- shall remain asserted for 30 
seconds or until Drive 1 accepts the first command. See also 6.3.4 and 6.3.13.

When the drive is reset by SRST, the drive shall set BSY=1. 

See also 7.2.6.

When a reset is accepted, and with BSY set:

 a) Both drives perform any necessary hardware initialization
 b) Both drives clear any previously programmed drive parameters 
 c) Both drives may revert to the default condition
 d) Both drives load the Command Block Registers with their default values
 e) If a hardware reset, Drive 0 waits for DASP- to be asserted by Drive 1
 f) If operational, Drive 1 asserts DASP-
 g) Drive 0 waits for PDIAG- to be asserted if Drive 1 asserts DASP-
 h) If operational, Drive 1 clears BSY
 i) If operational, Drive 1 asserts PDIAG-
 j) Drive 0 clears BSY

No interrupt is generated when initialization is complete.

The default values for the Command Block Registers if no self-tests are 
performed or if no errors occurred are: 

      Error         = 01h       Cylinder Low  = 00h 
      Sector Count  = 01h       Cylinder High = 00h 
      Sector Number = 01h       Drive/Head    = 00h 

The Error Register shall contain a Diagnostic Code (see Table 9.2) if a self-
test is performed. 

Following any reset, the host should issue an Initialize Drive Parameters 
command to ensure the drive is initialized as desired. 

There are three types of reset in ATA. The following is a suggested method of 
classifying reset actions: 

 - Power On Reset: the drive executes a series of electrical circuitry 
   diagnostics, spins up the HDA, tests speed and other mechanical 
   parametrics, and sets default values.
 - Hardware Reset: the drive executes a series of electrical circuitry 
   diagnostics, and resets to default values. 
 - Software Reset: the drive resets the interface circuitry according to the 
   Set Features requirement (See 9.21)

8.2   Translate Mode 

The cylinder, head and sector geometry of the drive as presented to the host 
may differ from the actual physical geometry. Translate mode is an optional 
and device specific means of mapping between the two. 

8.3  Power Conditions

Optional power commands permit the host to modify the behavior of the drive in 
a manner which reduces the power required to operate. 

                        TABLE 8-1:  POWER CONDITIONS
             +----------+----+----+----+------------------+-----+
             |   Mode   |SRST| BSY|DRDY| Interface Active |Media|
             +----------+----+----+----+------------------+-----+
             | Sleep    |  * |  x |  x |         *        |  0  |
             |          |    |    |    |                  |     |
             | Standby  |  x |  0 |  1 |        Yes       |  0  |
             |          |    |    |    |                  |     |
             | Idle     |  x |  0 |  1 |        Yes       |  1  |
             |          |    |    |    |                  |     |
             | Active   |  x |  x |  x |        Yes       |  1  |
             +----------+----+----+----+------------------+-----+
             |   1 = Active    0 = Inactive        * See 9.23   |
             +--------------------------------------------------+

The lowest power consumption when the drive is powered on occurs in Sleep 
mode. When in Sleep mode, the drive requires a reset to be activated (see 
9.23). The time to respond could be as long as 30 seconds or more. 

In Standby mode the drive interface is capable of accepting commands, but as 
the media is not immediately accessible, it could take the drive as long as 30 
seconds or more to respond.

In Idle mode the drive is capable of responding immediately to media access 
requests. A drive in Idle mode may take longer to complete the execution of a 
command because it may have to activate some circuitry.

In Active mode the drive is capable of responding immediately to media access 
requests, and commands complete execution in the shortest possible time.

Ready is not a power condition. A drive may post ready at the interface even 
though the media may not be accessible.

See specific power-related commands.

8.4  Error Posting 

The errors that are valid for each command are defined in Table 8-1. It is not 
a requirement that all valid conditions be implemented. See 7.2.9 and 7.2.13 
for the definition of the Error Register and Status Register bits.

                        TABLE 8-2:  REGISTER CONTENTS
                          +----------------------------+---------------------+
                          |       Error Register       |   Status Register   |
                          |BBK|UNC|IDNF|ABRT|TK0NF|AMNF|DRDY|DWF|DSC|CORR|ERR| 
 +------------------------+---+---+----+----+-----+----+----+---+---+----+---+
 | Acknowledge Media Chge |   |   |    |  V |     |    |    |   |   |    |   |
 | Boot - Post-Boot       |   |   |    |  V |     |    |    |   |   |    |   |
 | Boot - Pre-Boot        |   |   |    |  V |     |    |    |   |   |    |   |
 | Check Power Mode       |   |   |    |  V |     |    |  V | V | V |    | V |
 | Door Lock              |   |   |  V |  V |     |    |  V |   |   |    |   |
 | Door Unlock            |   |   |    |  V |     |    |    |   |   |    |   |
 | Execute Drive Diags    |         See 9.7            |    |   |   |    | V |
 | Format Track           |   |   |  V |  V |     |    |  V | V | V |    | V |
 | Identify Drive         |   |   |    |  V |     |    |  V | V | V |    | V |
 | Idle                   |   |   |    |  V |     |    |  V | V | V |    | V |
 | Idle Immediate         |   |   |    |  V |     |    |  V | V | V |    | V |
 | Initialize Drive Parms |   |   |    |    |     |    |  V | V | V |    |   |
 | NOP                    |   |   |    |  V |     |    |    |   |   |    | V |
 | Read Buffer            |   |   |    |  V |     |    |  V | V | V |    | V |
 | Read DMA               | V | V |  V |  V |     |  V |  V | V | V |  V | V |
 | Read Long              | V |   |  V |  V |     |  V |  V | V | V |    | V |
 | Read Multiple          | V | V |  V |  V |     |  V |  V | V | V |  V | V |
 | Read Sector(s)         | V | V |  V |  V |     |  V |  V | V | V |  V | V |
 | Read Verify Sector(s)  | V | V |  V |  V |     |  V |  V | V | V |  V | V |
 | Recalibrate            |   |   |    |  V |  V  |    |  V | V | V |    | V |
 | Seek                   |   |   |  V |  V |     |    |  V | V | V |    | V |
 | Set Features           |   |   |    |  V |     |    |  V | V | V |    | V |
 | Set Multiple Mode      |   |   |    |  V |     |    |  V | V | V |    | V |
 | Sleep                  |   |   |    |  V |     |    |  V | V | V |    | V |
 | Standby                |   |   |    |  V |     |    |  V | V | V |    | V |
 | Standby Immediate      |   |   |    |  V |     |    |  V | V | V |    | V |
 | Write Buffer           |   |   |    |  V |     |    |  V | V | V |    | V |
 | Write DMA              | V |   |  V |  V |     |    |  V | V | V |    | V |
 | Write Long             | V |   |  V |  V |     |    |  V | V | V |    | V |
 | Write Multiple         | V |   |  V |  V |     |    |  V | V | V |    | V |
 | Write Same             | V |   |  V |  V |     |    |  V | V | V |    | V |
 | Write Sector(s)        | V |   |  V |  V |     |    |  V | V | V |    | V |
 | Write Verify           | V | V |  V |  V |     | V  |  V | V | V | V  | V |
 +------------------------+---+---+----+----+-----+----+----+---+---+----+---+
 | Invalid Command Code   |   |   |    |  V |     |    |  V | V | V |    | V |
 +------------------------+---+---+----+----+-----+----+----+---+---+----+---+
 | V = valid on this command                                                 |
 +---------------------------------------------------------------------------+

9.  Command Descriptions

Commands are issued to the drive by loading the pertinent registers in the 
command block with the needed parameters, and then writing the command code to 
the Command Register. 

The manner in which a command is accepted varies. There are three classes 
(see Table 9-1) of command acceptance, all predicated on the fact that to 
receive a command, BSY=0:

 - Upon receipt of a Class 1 command, the drive sets BSY within 400 nsec.
 - Upon receipt of a Class 2 command, the drive sets BSY within 400 nsec, sets 
   up the sector buffer for a write operation, sets DRQ within 700 usec, and 
   clears BSY within 400 nsec of setting DRQ.
 - Upon receipt of a Class 3 command, the drive sets BSY within 400 nsec, sets 
   up the sector buffer for a write operation, sets DRQ within 20 msec, and 
   clears BSY within 400 nsec of setting DRQ.

  NOTE: DRQ may be set so quickly on Class 2 and Class 3 that the BSY 
        transition is too short for BSY=1 to be recognized.

The drive shall implement all mandatory commands as identified by an M, and 
may implement the optional commands identified by an O, in Table 9-1. V 
indicates a Vendor Specific command code.

If a new command is issued to a drive which has an uncompleted command 
(subsequently referred to as Old_Command) in progress, the drive shall 
immediately respond to the new command (Subsequently referred to as 
New_Command), even if execution of the Old_Command could have been completed. 

There shall be no indication given to the system as to the status of the 
Old_Command which was being executed at the time the New_Command was issued. 

            TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 1 of 2
                                               +-------+-------------------+
  +-----+                                      |Command|  Parameters Used  |
  |Class|                                      | Code  |FR  SC  SN  CY  DH |
  +-----+----------------------------------+---+-------+---+---+---+---+---+
  |  1  | Acknowledge Media Chge           | O |  DBh  |   |   |   |   | D |
  |  1  | Boot - Post-Boot                 | O |  DCh  |   |   |   |   | D |
  |  1  | Boot - Pre-Boot                  | O |  DDh  |   |   |   |   | D |
  |  1  | Check Power Mode                 | O |98h E5h|   | y |   |   | D |
  |  1  | Door Lock                        | O |  DEh  |   |   |   |   | D |
  |  1  | Door Unlock                      | O |  DFh  |   |   |   |   | D |
  |  1  | Execute Drive Diagnostic         | M |  90h  |   |   |   |   | D*|
  |  2  | Format Track                     | M |  50h  | * | y |   | y | y |
  |  1  | Identify Drive                   | O |  ECh  |   |   |   |   | D |
  |  1  | Idle                             | O |97h E3h|   | y |   |   | D |
  |  1  | Idle Immediate                   | O |95h E1h|   |   |   |   | D |
  |  1  | Initialize Drive Parameters      | M |  91h  |   | y |   |   | y |
  |  1  | NOP                              | O |  00h  |   |   |   |   | y |
  |  1  | Read Buffer                      | O |  E4h  |   |   |   |   | D |
  |  1  | Read DMA (w/retry)               | O |  C8h  |   | y | y | y | y |
  |  1  | Read DMA (w/o retry)             | O |  C9h  |   | y | y | y | y |
  |  1  | Read Long (w/retry)              | M |  22   |   | y | y | y | y |
  |  1  | Read Long (w/o retry)            | M |  23   |   | y | y | y | y |
  |  1  | Read Multiple                    | O |  C4h  |   | y | y | y | y |
  |  1  | Read Sector(s) (w/retry)         | M |  20   |   | y | y | y | y |
  |  1  | Read Sector(s) (w/o retry)       | M |  21   |   | y | y | y | y |
  |  1  | Read Verify Sector(s) (w/retry)  | M |  40   |   | y | y | y | y |
  |  1  | Read Verify Sector(s) (w/o retry)| M |  41   |   | y | y | y | y |
  |  1  | Recalibrate                      | M |  1xh  |   |   |   |   | D |
  +-----+----------------------------------+---+-------+---+---+---+---+---+
            TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 2 of 2
                                               +-------+-------------------+
  +-----+                                      |Command|  Parameters Used  |
  |Class|                                      | Code  |FR  SC  SN  CY  DH |
  +-----+----------------------------------+---+-------+---+---+---+---+---+
  |  1  | Seek                             | M |  7xh  |   |   | y | y | y |
  |  1  | Set Features                     | O |  EFh  | y |   |   |   | D |
  |  1  | Set Multiple Mode                | O |  C6h  |   | y |   |   | D |
  |  1  | Sleep                            | O |99h E6h|   |   |   |   | D |
  |  1  | Standby                          | O |96h E2h|   | y |   |   | D |
  |  1  | Standby Immediate                | O |94h E0h|   |   |   |   | D |
  |  2  | Write Buffer                     | O |  E8h  |   |   |   |   | D |
  |  3  | Write DMA (w/retry)              | O |  CAh  |   | y | y | y | y |
  |  3  | Write DMA (w/o retry)            | O |  CBh  |   | y | y | y | y |
  |  2  | Write Long (w/retry)             | M |  32   | * | y | y | y | y |
  |  2  | Write Long (w/o retry)           | M |  33   | * | y | y | y | y |
  |  3  | Write Multiple                   | O |  C5h  | * | y | y | y | y |
  |  3  | Write Same                       | O |  E9h  | y | y | y | y | y |
  |  2  | Write Sector(s) (w/retry)        | M |  30   | * | y | y | y | y |
  |  2  | Write Sector(s) (w/o retry)      | M |  31   | * | y | y | y | y |
  |  3  | Write Verify                     | O |  3Ch  | * | y | y | y | y |
  |     | Vendor Unique                    | V |  9Ah  |   |   |   |   |   |
  |     | Vendor Unique                    | V | C0-C3h|   |   |   |   |   |
  |     | Vendor Unique                    | V |  8xh  |   |   |   |   |   |
  |     | Vendor Unique                    | V |F0h-FFh|   |   |   |   |   |
  |     | Reserved: All remaining codes    |   |       |   |   |   |   |   |
  +-----+----------------------------------+---+-------+---+---+---+---+---+
  |     | CY = Cylinder Registers         SC = Sector Count Register       |
  |     | DH = Drive/Head Register        SN = Sector Number Register      |
  |     | FR = Features Register (see command descriptions for use)        |
  |     | y - the register contains a valid parameter for this command.    |
  |     |     For the Drive/Head Register, y means both the drive and      |
  |     |     head parameters are used.                                    |
  |     | D - only the drive parameter is valid and not the head parameter.|
  |     | D* - Addressed to Drive 0 but both drives execute it.            |
  |     | * - Maintained for compatibility (see 7.2.9)                     |
  +-----+------------------------------------------------------------------+

9.1  Acknowledge Media Change (Removable)

If the drive is operating in a mode which requires that the operating system 
acknowledge a media change, this command clears the Media Change Error so that 
normal operation can resume. If the drive is not operating in such a mode, 
this command returns an Abort error.

9.2  Boot - Post-Boot (Removable)

This command provides a means to send vendor-specific information that may be 
required in order to pass diagnostics which are applicable to non-removable 
disk drives.

9.3  Boot - Pre-Boot (Removable)
 
This command is issued to prepare a removable drive to respond to boot. 

9.4  Check Power Mode

This command checks the power mode. 

If the drive is in, going to, or recovering from the Standby Mode the drive 
shall set BSY, set the Sector Count Register to 00h, clear BSY, and generate 
an interrupt. 

If the drive is in the Idle Mode, the drive shall set BSY, set the Sector 
Count Register to FFh, clear BSY, and generate an interrupt. 

9.5  Door Lock (Removable)

This command locks the door if the drive is Ready and unlocked, otherwise it 
responds with Not Ready. 

9.6  Door Unlock (Removable)

This command unlocks the door if the drive is Ready and locked, otherwise it 
responds with Not Ready. 

9.7  Execute Drive Diagnostic

This command shall perform the internal diagnostic tests implemented by the 
drive. See also 6.3.4 and 6.3.13. The DRV bit is ignored. Both drives, if 
present, shall execute this command. 

If Drive 1 is present: 

 - Drive 0 waits up to 5 seconds for Drive 1 to assert PDIAG-. 
 - If Drive 1 has not asserted PDIAG-, indicating a failure, Drive 0 shall 
   append 80h to its own diagnostic status. 
 - Both drives shall execute diagnostics. 
 - If Drive 1 diagnostic failure is detected when Drive 0 status is read, 
   Drive 1 status is obtained by setting the DRV bit, and reading status. 

If there is no Drive 1 present:

 - Drive 0 posts only its own diagnostic results. 
 - Drive 0 clears BSY, and generates an interrupt. 

The Diagnostic Code written to the Error Register is a unique 8-bit code as 
shown in Table 9-2, and not as the single bit flags defined in 7.2.9. 

If Drive 1 fails diagnostics, Drive 0 "ORs" 80h with its own status and loads 
that code into the Error Register. If Drive 1 passes diagnostics or there is 
no Drive 1 connected, Drive 0 "ORs" 00h with its own status and loads that 
code into the Error Register. 

                         TABLE 9-2:  DIAGNOSTIC CODES 
                 +-------+
                 | Code  | 
                 +-------+----------------------------------+
                 |  01h  | No error detected                |
                 |  02h  | Formatter device error           |
                 |  03h  | Sector buffer error              |
                 |  04h  | ECC circuitry error              |
                 |  05h  | Controlling microprocessor error |
                 |  8xh  | Drive 1 failed                   |
                 +-------+----------------------------------+ 

9.8  Format Track

The implementation of the Format Track command is vendor specific. The actions 
may be a physical reformatting of a track, initializing the data field 
contents to some value, or doing nothing. 

The Sector Count Register contains the number of sectors per track. 

The track address is specified in the Cylinder High and Cylinder Low 
Registers, and the number of sectors is specified in the Sector Count 
Register. When the command is accepted, the drive sets the DRQ bit and waits 
for the host to fill the sector buffer. When the sector buffer is full, the 
drive clears DRQ, sets BSY and begins command execution. 

The contents of the sector buffer shall not be written to the media, and may 
be either ignored or interpreted as follows: 

     DD15 ---- DD0               DD15 ---- DD0
    +-------------+             +-------------+--------------------------+
    | First Sector|             | Last Sector |  Remainder of buffer     |
    | Descriptor  | : : : : : : | Descriptor  |  filled with zeros       |
    +-------------+             +-------------+--------------------------+

One 16-bit word represents each sector, the words being contiguous from the 
start of a sector. Any words remaining in the buffer after the representation 
of the last sector are filled with zeros. DD15-8 contain the sector number. If 
an interleave is specified, the words appear in the same sequence as they 
appear on the track. DD7-0 contain a descriptor value defined as follows: 

     00h - Format sector as good
     20h - Unassign the alternate location for this sector
     40h - Assign this sector to an alternate location
     80h - Format sector as bad

  NOTE: Some users of the ATA drive expect the operating system partition 
        table to be erased on a Format command. It is recommended that a drive 
        which does not perform a physical format of the track, write a data 
        pattern of all zeros to the sectors which have been specified by the 
        Format Track command. 

  NOTE: It is recommended that implementors resassign data blocks which show 
        repeated errors. 

9.9  Identify Drive

The Identify Drive command enables the host to receive parameter information 
from the drive. When the command is issued, the drive sets BSY, stores the 
required parameter information in the sector buffer, sets DRQ, and generates 
an interrupt. The host then reads the information out of the sector buffer. 
The parameter words in the buffer have the arrangement and meanings defined in 
Table 9-3. All reserved bits or words shall be zero.

 +-------+          TABLE 9-3:  IDENTIFY DRIVE INFORMATION (1)
 |  Word |
 +-------+------------------------------------------------------------------+
 |    0  | General configuration bit-significant information:               |
 |       |   15  0   reserved for non-magnetic drives                       |
 |       |   14  1=format speed tolerance gap required                      |
 |       |   13  1=track offset option available                            |
 |       |   12  1=data strobe offset option available                      |
 |       |   11  1=rotational speed tolerance is > 0.5%                     |
 |       |   10  1=disk transfer rate > 10 Mbs                              |
 |       |    9  1=disk transfer rate > 5Mbs but <= 10Mbs                   |
 |       |    8  1=disk transfer rate <= 5Mbs                               |
 |       |    7  1=removable cartridge drive                                |
 |       |    6  1=fixed drive                                              |
 |       |    5  1=spindle motor control option implemented                 |
 |       |    4  1=head switch time > 15 usec                               |
 |       |    3  1=not MFM encoded                                          |
 |       |    2  1=soft sectored                                            |
 |       |    1  1=hard sectored                                            |
 |       |    0  0=reserved                                                 |
 |    1  | Number of cylinders                                              |
 |    2  |   reserved                                                       |
 |    3  | Number of heads                                                  |
 |    4  | Number of unformatted bytes per track                            |
 |    5  | Number of unformatted bytes per sector                           |
 |    6  | Number of sectors per track                                      |
 |  7-9  |   Vendor Unique                                                  |
 | 10-19 | Serial number (20 ASCII characters, 0000h=not specified)         |
 |   20  | Buffer type                                                      |
 |   21  | Buffer size in 512 byte increments (0000h=not specified)         |
 |   22  | # of ECC bytes avail on Read/Write Long cmds (0000h=not spec'd)  |
 | 23-26 | Firmware revision (8 ASCII characters, 0000h=not specified)      |
 | 27-46 | Model number (40 ASCII characters, 0000h=not specified)          |
 +-------+------------------------------------------------------------------+

 +-------+          TABLE 9-3:  IDENTIFY DRIVE INFORMATION (2)
 |  Word |
 +-------+------------------------------------------------------------------+
 |   47  | 15-8  Vendor Unique                                              |
 |       |  7-0  00h = Read/Write Multiple commands not implemented         |
 |       |       xxh = Maximum number of sectors that can be transferred    |
 |       |             per interrupt on Read and Write Multiple commands    |
 |   48  | 0000h = cannot perform doubleword I/O    Included for Backwards  |
 |       | 0001h = can perform doubleword I/O       Compatible VU Use       |
 |   49  | Capabilities                                                     |
 |       | 15-10  0=reserved                                                |
 |       |     9  1=LBA Supported                                           |
 |       |     8  1=DMA Supported                                           |
 |       |  7- 0  Vendor Unique                                             |
 |   50  |   reserved                                                       |
 |   51  | 15-8  PIO data transfer cycle timing mode                        |
 |       |  7-0  Vendor Unique                                              |
 |   52  | 15-8  DMA data transfer cycle timing mode                        |
 |       |  7-0  Vendor Unique                                              |
 |   53  | 15-1    reserved                                                 |
 |       |    0  1=the fields reported in Words 54-58 are valid             |
 |       |       0=the fields reported in Words 54-58 may be valid          |
 |   54  | Number of current cylinders                                      |
 |   55  | Number of current heads                                          |
 |   56  | Number of current sectors per track                              |
 | 57-58 | Current capacity in sectors                                      |
 |   59  | 15-9    reserved                                                 |
 |       |    8  1 = Multiple Sector Setting is Valid                       |
 |       |  7-0  xxh = Current setting for number of sectors that can be    |
 |       |             transferred per interrupt on R/W Multiple commands   |
 | 60-61 | Total Number of User Addressable Sectors (LBA Mode Only)         |
 |   62  | 15-8  Single Word DMA Transfer Mode Active                       |
 |       |  7-0  Single Word DMA Transfer Modes Supported (see 11-3a)       |
 |   63  | 15-8  Multiword DMA Transfer Mode Active                         |
 |       |  7-0  Multiword DMA Transfer Modes Supported (see 11-3b)         |
 | 64-127|   reserved                                                       |
 |128-159| Vendor Unique                                                    |
 |160-255|   reserved                                                       |
 +-------+------------------------------------------------------------------+

The fields described in 9.4.1 through 9.4.5 are not affected by the Initialize 
Drive Parameters command.

9.9.1  Word 1: Number of cylinders

The number of user-addressable cylinders in the default translation mode.

9.9.2  Word 3: Number of heads

The number of user-addressable heads in the default translation mode.

9.9.3  Word 4: Number of unformatted bytes per track

The number of unformatted bytes per translated track in the default 
translation mode.

9.9.4  Word 5: Number of unformatted bytes per sector

The number of unformatted bytes per sector in the default translation mode.

9.9.5  Word 6: Number of sectors per track

The number of user-addressable sectors per track in the default translation 
mode.

9.9.6  Word 10-19: Serial Number

The contents of this field are right justified and padded with spaces (20h). 

9.9.7  Word 20: Buffer Type           

The contents of the field are determined by the manufacturer. 

  0000h = not specified.
  0001h = a single ported single sector buffer which is not capable of 
          simultaneous data transfers to or from the host and the disk. 
  0002h = a dual ported multi-sector buffer capable of simultaneous data 
          transfers to or from the host and the disk.
  0003h = a dual ported multi-sector buffer capable of simultaneous transfers 
          with a read cacheing capability.
  0004-FFFFh = reserved                           

These codes are typically not used by the operating system, however, they are 
useful for diagnostic programs which perform initialization routines e.g. a 
different interleave may be desirable for 0001h vs 0002h or 0003h.

9.9.8  Word 22: ECC bytes Available on Read/Write Long Commands 

If the contents of this field are set to a value other than 4, the only way to 
use this information is via the Set Features commands.

9.9.9  Word 23-26: Firmware Revision

The contents of this field are left justified and padded with spaces (20h). 

9.9.10  Word 27-46: Model Number

The contents of this field are left justified and padded with spaces (20h). 

9.9.11 Word 51:  PIO data transfer cycle timing mode   

The PIO transfer timing for each ATA device falls into categories which have 
unique parametric timing specifications. To determine the proper device timing 
category, compare the Cycle Time specified in Figure 11-1 with the contents of 
this field. The value returned in Bits 15-8 should fall into one of the 
categories specified in Figure 11-1, and if it does not, then Mode 0 shall be 
used to serve as the default timing.

9.9.12 Word 52:  DMA data transfer cycle timing mode

The DMA transfer timing for each ATA device falls into categories which have 
unique parametric timing specifications. To determine the proper device timing 
category, compare the Cycle Time specified in Figure 11-3 with the contents of 
this field. The value returned in Bits 15-8 should fall into one of the 
categories specified in Figure 11-3, and if it does not, then Mode 0 shall be 
used to serve as the default timing.

The contents of this word shall be ignored if Words 62 or 63 are supported.

9.9.13 Word 54:  Number of current cylinders

The number of user-addressable cylinders in the current translation mode.

9.9.14 Word 55:  Number of current heads

The number of user-addressable heads in the current translation mode.

9.9.15 Word 56:  Number of current sectors per track

The number of user-addressable sectors per track in the current translation 
mode.

9.9.16 Word 57-58: Current capacity in sectors

The current capacity in sectors excludes all sectors used for device-specific 
purposes. The number of sectors of available capacity may be calculated as: 

   (Number of current cylinders 
    * Number of current heads 
    * Number of current sectors per track)


9.9.17  Word 59: Multiple Sector Setting

If the valid bit is set, then bits 7-0 reflect the number of sectors currently 
set to transfer on a Read or Write Multiple command.

9.9.18  Word 60-61: Total Number of User Addressable Sectors

If the drive supports LBA Mode, these words reflect the total number of user 
addressable sectors. This value does not depend on the current drive geometry. 
If the drive does not support LBA mode, these words shall be set to 0. 

9.9.19  Word 62: Single Word DMA Transfer

The low order byte identifies by bit all of the Modes which are supported e.g. 
if Mode 0 is supported, bit 0 is set. The high order byte contains a single 
bit set to indicate which mode is active.

9.9.20  Word 63: Multiword DMA Transfer

The low order byte identifies by bit all of the Modes which are supported e.g. 
if Mode 0 is supported, bit 0 is set. The high order byte contains a single 
bit set to indicate which mode is active. 

9.10  Idle

This command causes the drive to set BSY, enter the Idle Mode, clear BSY, and 
generate an interrupt. The interrupt is generated even though the drive may 
not have fully transitioned to Idle Mode. 

If the drive is already spinning, the spinup sequence is not executed. 

If the Sector Count Register is non-zero then the automatic power down 
sequence shall be enabled and the timer begins counting down immediately. If 
the Sector Count Register is zero then the automatic power down sequence shall 
be disabled.

9.11  Idle Immediate

This command causes the drive to set BSY, enter the Idle Mode, clear BSY, and 
generate an interrupt. The interrupt is generated even though the drive may 
not have fully transitioned to Idle Mode. 

9.12  Initialize Drive Parameters

This command enables the host to set the number of sectors per track and the 
number of heads minus 1, per cylinder. Upon receipt of the command, the drive 
sets BSY, saves the parameters, clears BSY, and generates an interrupt. 

The only two register values used by this command are the Sector Count 
Register which specifies the number of sectors per track, and the Drive/Head 
Register which specifies the number of heads minus 1. The DRV bit designates 
these values to Drive 0 or Drive 1, as appropriate. 

The sector count and head values are not checked for validity by this command. 
If they are invalid, no error will be posted until an illegal access is made 
by some other command. 

9.13  NOP

This command enables a host which can only perform 16-bit register accesses to 
check drive status. The drive shall respond as it does to an unrecognized 
command by setting Abort in the Error Register, Error in the Status Register, 
clearing Busy in the Status Register, and asserting INTRQ. 

NOTE: When a 16-bit host writes to the Drive Head Register, one byte contains 
      the Command Register, so the drive sees a new command when the intended 
      purpose is only to select a drive. Both drives may be Busy but not 
      necessarily Ready i.e. Drive 0 may be ready, but not drive 1. To check 
      this possibility a typical sequence for an 8-bit host would be:

       a. Read the Status Register (wait until Busy False)
       b. Select the drive (write to the Drive Head Register)
       c. Read the Status Register (wait until Busy False and Ready True)
       d. Send the command (write to the Command Register). 

      As a 16-bit host executes 2 and 4 simultaneously, a problem occurs if 
      the drive being selected is Not Ready at the time the command is issued. 

9.14  Read Buffer

The Read Buffer command enables the host to read the current contents of the 
drive's sector buffer. When this command is issued, the drive sets BSY, sets 
up the sector buffer for a read operation, sets DRQ, clears BSY, and generates 
an interrupt. The host then reads up to 512 bytes of data from the buffer. 

The Read Buffer and Write Buffer commands shall be synchronized such that 
sequential Write Buffer and Read Buffer commands access the same 512 bytes 
within the buffer. 

9.15  Read DMA

This command executes in a similar manner to the Read Sectors command except 
for the following:

 - the host initializes a slave-DMA channel prior to issuing the command
 - data transfers are qualified by DMARQ and are performed by the slave-DMA 
   channel 
 - the drive issues only one interrupt per command to indicate that data 
   transfer has terminated and status is available.

Any unrecoverable error encountered during execution of a Read DMA command 
results in the termination of data transfer at the sector where the error was 
detected. The sector in error is not transferred. The drive generates an 
interrupt to indicate that data transfer has terminated and status is 
available. The error posting is the same as that of the Read Sectors command. 

9.16  Read Long

The Read Long command performs similarly to the Read Sectors command except 
that it returns the data and the ECC bytes contained in the data field of the 
desired sector. During a Read Long command, the drive does not check the ECC 
bytes to determine if there has been a data error. Only single sector read 
long operations are supported. 

The transfer of the ECC bytes shall be 8-bits wide.

9.17  Read Multiple Command

The Read Multiple command performs similarly to the Read Sectors command. 
Interrupts are not generated on every sector, but on the transfer of a block 
which contains the number of sectors defined by a Set Multiple command. 

Command execution is identical to the Read Sectors operation except that the 
number of sectors defined by a Set Multiple command are transferred without 
intervening interrupts. DRQ qualification of the transfer is required only at 
the start of the data block, not on each sector. 

The block count of sectors to be transferred without intervening interrupts is 
programmed by the Set Multiple Mode command, which shall be executed prior to 
the Read Multiple command. 

When the Read Multiple command is issued, the Sector Count Register contains 
the number of sectors (not the number of blocks or the block count) requested. 

If the number of requested sectors is not evenly divisible by the block count, 
as many full blocks as possible are transferred, followed by a final, partial 
block transfer. The partial block transfer shall be for n sectors, where 

          n = Remainder (Sector Count / Block Count) 

If the Read Multiple command is attempted before the Set Multiple Mode command 
has been executed or when Read Multiple commands are disabled, the Read 
Multiple operation shall be rejected with an Aborted Command error. 

Disk errors encountered during Read Multiple commands are posted at the 
beginning of the block or partial block transfer, but DRQ is still set and the 
data transfer shall take place as it normally would, including transfer of 
corrupted data, if any. 

The contents of the Command Block Registers following the transfer of a data 
block which had a sector in error are undefined. The host should retry the 
transfer as individual requests to obtain valid error information.

Subsequent blocks or partial blocks are transferred only if the error was a 
correctable data error. All other errors cause the command to stop after 
transfer of the block which contained the error. Interrupts are generated when 
DRQ is set at the beginning of each block or partial block. 

9.18  Read Sector(s)

This command reads from 1 to 256 sectors as specified in the Sector Count 
register. A sector count of 0 requests 256 sectors. The transfer begins at the 
sector specified in the Sector Number Register. See 10.1 for the DRQ, IRQ and 
BSY protocol on data transfers.

If the drive is not already on the desired track, an implied seek is 
performed. Once at the desired track, the drive searches for the appropriate 
ID field. 

If retries are disabled and two index pulses have occurred without error free 
reading of the requested ID, an ID Not Found error is posted. 

If retries are enabled, up to a vendor specific number of attempts may be made 
to read the requested ID before posting an error. 

If the ID is read correctly, the data address mark shall be recognized within 
a specified number of bytes, or the Address Mark Not Found error is posted. 

DRQ is always set prior to data transfer regardless of the presence or absence 
of an error condition. 

At command completion, the Command Block Registers contain the cylinder, head, 
and sector number of the last sector read. 

If an error occurs, the read terminates at the sector where the error 
occurred. The Command Block Registers contain the cylinder, head, and sector 
number of the sector where the error occurred. 

The flawed data is pending in the sector buffer. 

9.19  Read Verify Sector(s)

This command is identical to the Read Sectors command, except that DRQ is 
never set, and no data is transferred to the host. See 10.3 for protocol. When 
the command is accepted, the drive sets BSY. 

When the requested sectors have been verified, the drive clears BSY and 
generates an interrupt. Upon command completion, the Command Block Registers 
contain the cylinder, head, and sector number of the last sector verified. 

If an error occurs, the verify terminates at the sector where the error 
occurs. The Command Block Registers contain the cylinder, head, and sector 
number of the sector where the error occurred. The Sector Count Register shall 
contain the number of sectors not yet verified. 

9.20  Recalibrate

This command moves the read/write heads from anywhere on the disk to cylinder 
0. Upon receipt of the command, the drive sets BSY and issues a seek to 
cylinder zero. The drive then waits for the seek to complete before updating 
status, clearing BSY and generating an interrupt. 

If the drive cannot reach cylinder 0, a Track Not Found error is posted.

9.21  Seek

This command initiates a seek to the track and selects the head specified in 
the command block. The drive need not be formatted for a seek to execute 
properly. See 10.3 for protocol. The drive shall not set DSC=1 until the 
action of seeking has completed. The drive may return the interrupt before the 
seek is completed. 

If another command is issued to the drive while a seek is being executed, the 
drive sets BSY=1, waits for the seek to complete, and then begins execution of 
the command. 

9.22  Set Features

This command is used by the host to establish the following parameters which 
affect the execution of certain drive features as shown in Table 9-4.

                 TABLE 9-4:  SET FEATURE REGISTER DEFINITIONS
    +-----+---------------------------------------------------------------+
    | 01h | Enable 8-bit data transfers (see 6.3.5)                       |
    | 02h | Enable Write Cache *                                          |
    | 03h | Set Transfer Mode based on value in Sector Count Register     |
    | 33h | Disable Retry *                                               |
    | 44h | Vendor unique length of ECC on Read Long/Write Long commands  |
    | 54h | Set cache segments to Sector Count Register value *           |
    | 55h | Disable read look-ahead feature                               |
    | 66h | Disable reverting to power on defaults (see 9.22)             |
    | 77h | Disable ECC *                                                 |
    | 81h | Disable 8-bit data transfers (see 6.3.5)                      |
    | 82h | Disable Write Cache *                                         |
    | 88h | Enable ECC *                                                  |
    | 99h | Enable Retries *                                              |
    | AAh | Enable read look-ahead feature                                |
    | ABh | Set maximum prefetch using Sector Count Register value *      |
    | BBh | 4 bytes of ECC apply on Read Long/Write Long commands         |
    | CCh | Enable reverting to power on defaults (see 9.22)              |
    +-----+---------------------------------------------------------------+
            * These commands are Vendor-specified

See 10.3 for protocol. If the value in the register is not supported or is 
invalid, the drive posts an Aborted Command error. 

At power on, or after a hardware reset, the default mode is the same as that 
represented by values greater than 80h. A setting of 66h allows settings of 
greater than 80h which may have been modified since power on to remain at the 
same setting after a software reset. 

A host can choose the transfer mechanism by Set Transfer Mode and specifying a 
value in the Sector Count Register. The upper 5 bits define the type of 
transfer and the low order 3 bits encode the mode value. 

   Block Transfer (Default)    00000  000
   Single Word DMA Mode x      00010  0xx
   Multiword DMA Mode 0        00100  000

See vendor specification for the default mode of the commands which are 
vendor-specified.

9.23  Set Multiple Mode

This command enables the drive to perform Read and Write Multiple operations 
and establishes the block count for these commands. See 10.3 for protocol. 

The Sector Count Register is loaded with the number of sectors per block. 
Drives shall support block sizes of 2, 4, 8, and 16 sectors, if their buffer 
size is at least 8,192 bytes, and may also support other block sizes. Upon 
receipt of the command, the drive sets BSY=1 and checks the Sector Count 
Register. 

If the Sector Count Register contains a valid value and the block count is 
supported, the value is loaded for all subsequent Read Multiple and Write 
Multiple commands and execution of those commands is enabled. If a block count 
is not supported, an Aborted Command error is posted, and Read Multiple and 
Write Multiple commands are disabled. 

If the Sector Count Register contains 0 when the command is issued, Read and 
Write Multiple commands are disabled. 

At power on, or after a hardware reset, the default mode is Read and Write 
Multiple disabled. If Disable Default has been set in the Features Register 
then the mode remains the same as that last established prior to a software 
reset, otherwise it reverts to the default of disabled.

9.24  Sleep

This command is the only way to cause the drive to enter Sleep Mode. The drive 
is spun down, and when it is stopped, BSY is cleared, an interrupt is 
generated, and the interface becomes inactive. 

The only way to recover from Sleep mode is with a software reset or a hardware 
reset. 

  NOTE: The use of hardware reset to recover from Sleep mode may be 
        incompatible with continued operation of the host system. 

A drive shall not power on in Sleep Mode nor remain in Sleep Mode following a 
reset sequence. If the drive is already spun down, the spin down sequence is 
not executed. 

9.25  Standby

This command causes the drive to enter the Standby Mode. See 10.3 for 
protocol. The drive may return the interrupt before the transition to Standby 
Mode is completed. 

If the drive is already spun down, the spin down sequence is not executed. 

If the Sector Count Register is non-zero then the automatic power down 
sequence shall be enabled and the timer will begin counting down when the 
drive returns to Idle mode. If the Sector Count Register is zero then the 
automatic power down sequence shall be disabled.

9.26  Standby Immediate

This command causes the drive to enter the Standby Mode. See 10.3 for 
protocol. The drive may return the interrupt before the transition to Standby 
Mode is completed. 

If the drive is already spun down, the spin down sequence is not executed. 

9.27  Write Buffer

This command enables the host to overwrite the contents of the drive's sector 
buffer with any data pattern desired. See 10.2 for protocol.

The Read Buffer and Write Buffer commands shall be synchronized within the 
drive such that sequential Write Buffer and Read Buffer commands access the 
same 512 bytes within the buffer. 

9.28  Write DMA

This command executes in a similar manner to Write Sectors except for the 
following:

 - the host initializes a slave-DMA channel prior to issuing the command 
 - data transfers are qualified by DMARQ and are performed by the slave-DMA 
   channel 
 - the drive issues only one interrupt per command to indicate that data 
   transfer has terminated and status is available. 

Any error encountered during Write DMA execution results in the termination of 
data transfer. The drive issues an interrupt to indicate that data transfer 
has terminated and status is available in the Error Register. The error 
posting is the same as that of the Write Sectors command. 

9.29  Write Long

This command is similar to the Write Sectors command except that it writes the 
data and the ECC bytes directly from the sector buffer; the drive does not 
generate the ECC bytes itself. Only single sector Write Long operations are 
supported. 

The transfer of the ECC bytes shall be 8-bits wide.

9.30  Write Multiple Command

This command is similar to the Write Sectors command. The drive sets BSY 
within 400 nsec of accepting the command, and interrupts are not presented on 
each sector but on the transfer of a block which contains the number of 
sectors defined by Set Multiple. 

Command execution is identical to the Write Sectors operation except that the 
number of sectors defined by the Set Multiple command are transferred without 
intervening interrupts. DRQ qualification of the transfer is required only at 
the start of the data block, not on each sector. 

The block count of sectors to be transferred without intervening interrupts is 
programmed by the Set Multiple Mode command, which shall be executed prior to 
the Read Multiple command. 

When the Write Multiple command is issued, the Sector Count Register contains 
the number of sectors (not the number of blocks or the block count) requested. 

If the number of requested sectors is not evenly divisible by the block count, 
as many full blocks as possible are transferred, followed by a final, partial 
block transfer. The partial block transfer is for n sectors, where 

          n = Remainder (Sector Count / Block Count) 

If the Write Multiple command is attempted before the Set Multiple Mode 
command has been executed or when Write Multiple commands are disabled, the 
Write Multiple operation shall be rejected with an aborted command error. 

Disk errors encountered during Write Multiple commands are posted after the 
attempted disk write of the block or partial block transferred. The Write 
command ends with the sector in error, even if it was in the middle of a 
block. Subsequent blocks are not transferred in the event of an error. 
Interrupts are generated when DRQ is set at the beginning of each block or 
partial block. 

The contents of the Command Block Registers following the transfer of a data 
block which had a sector in error are undefined. The host should retry the 
transfer as individual requests to obtain valid error information.

9.31  Write Same

This command executes in a similar manner to Write Sectors except that only 
one sector of data is transferred. The contents of the sector are written to 
the medium one or more times.

NOTE: The Write Same command allows for initialization of part or all of the 
medium to the specified data with a single command. 

If the Features Register is 22h, the drive shall write that part of the medium 
specified by the sector count, sector number, cylinder and drive/head 
registers. If the Features Register contains DDh, the drive shall initialize 
all the user accessible medium. If the register contains a value other than 
22h or DDh, the command shall be rejected with an aborted command error. 

The drive issues an interrupt to indicate that the command is complete. Any 
error encountered during execution results in the termination of the write 
operation. Status is available in the Error Register if an error occurs. The 
error posting is the same as that of the Write Sectors command. 

9.32  Write Sector(s)

This command writes from 1 to 256 sectors as specified in the Sector Count 
Register (a sector count of zero requests 256 sectors), beginning at the 
specified sector. See 10.1 for the DRQ, IRQ and BSY protocol on data 
transfers.

If the drive is not already on the desired track, an implied seek is 
performed. Once at the desired track, the drive searches for the appropriate 
ID field. 

If retries are disabled and two index pulses have occurred without error free 
reading of the requested ID, an ID Not Found error is posted. 

If retries are enabled, up to a vendor specific number of attempts may be made 
to read the requested ID before posting an error. 

If the ID is read correctly, the data loaded in the buffer is written to the 
data field of the sector, followed by the ECC bytes. Upon command completion, 
the Command Block Registers contain the cylinder, head, and sector number of 
the last sector written. 

If an error occurs during a write of more than one sector, writing terminates 
at the sector where the error occurs. The Command Block Registers contain the 
cylinder, head, and sector number of the sector where the error occurred. The 
host may then read the command block to determine what error has occurred, and 
on which sector. 

9.33  Write Verify

This command is similar to the Write Sectors command, except that each sector 
is verified immediately after being written. The verify operation is a read 
without transfer and a check for data errors. Any errors encountered during 
the verify operation are posted. Multiple sector Write Verify commands write 
all the requested sectors and then verify all the requested sectors before 
generating the final interrupt.

10. Protocol Overview

Commands can be grouped into different classes according to the protocols 
followed for command execution. The command classes with their associated 
protocols are defined below.

For all commands, the host first checks if BSY=1, and should proceed no 
further unless and until BSY=0. For most commands, the host will also wait for 
DRDY=1 before proceeding. Those commands shown with DRDY=x can be executed 
when DRDY=0. 

Data transfers may be accomplished in more ways than are described below, but 
these sequences should work with all known implementations of ATA drives. 

10.1  PIO Data In Commands

This class includes:

 - Identify Drive
 - Read Buffer
 - Read Long
 - Read Sector(s)

Execution includes the transfer of one or more 512 byte (>512 bytes on Read 
Long) sectors of data from the drive to the host. 

 a) The host writes any required parameters to the Features, Sector Count, 
    Sector Number, Cylinder and Drive/Head registers.
 b) The host writes the command code to the Command Register.
 c) The drive sets BSY and prepares for data transfer.
 d) When a sector of data is available, the drive sets DRQ and clears BSY 
    prior to asserting INTRQ.
 e) After detecting INTRQ, the host reads the Status Register, then reads one 
    sector of data via the Data Register. In response to the Status Register 
    being read, the drive negates INTRQ. 
 f) The drive clears DRQ. If transfer of another sector is required, the drive 
    also sets BSY and the above sequence is repeated from d).

10.1.1  PIO Read Command

 +- a) -+-- b) -+        +- e) -+--------+       +- e) -+--------+ 
 |Setup | Issue |        | Read |Transfer|       | Read |Transfer| 
 |      |Command|        |Status|  Data  |:::::::|Status|  Data  | 
 +------+-------+        +------+--------+       +------+--------+ 
 |BSY=0 |       |BSY=1   |BSY=0 |        |BSY=1  |BSY=0 |        |BSY=1
        |DRDY=1          |      |        |       |      |        |
                         |DRQ=1 |        |DRQ=0  |DRQ=1 |        |DRQ=0
                         |Assert|Negate  |       |Assert|Negate
                          INTRQ  INTRQ            INTRQ  INTRQ 

If Error Status is presented, the drive is prepared to transfer data, and it 
is at the host's discretion that the data is transferred. 

10.1.2  PIO Read Aborted Command

 +- a) -+-- b) -+        +- e) -+
 |Setup | Issue |        | Read |
 |      |Command|        |Status|
 +------+-------+        +------+
 |BSY=0 |       |BSY=1   |BSY=0 |      
        |DRDY=1          |      |
                         |DRQ=1 |DRQ=0
                         |Assert|Negate
                          INTRQ  INTRQ

Although DRQ=1, there is no data to be transferred under this condition.

10.2  PIO Data Out Commands

This class includes:

 - Format 
 - Write Buffer
 - Write Long
 - Write Sector(s)

Execution includes the transfer of one or more 512 byte (>512 bytes on Write 
Long) sectors of data from the drive to the host. 

 a) The host writes any required parameters to the Features, Sector Count, 
    Sector Number, Cylinder and Drive/Head registers.
 b) The host writes the command code to the Command Register.
 c) The drive sets DRQ when it is ready to accept the first sector of data.
 d) The host writes one sector of data via the Data Register.
 e) The drive clears DRQ and sets BSY.
 f) When the drive has completed processing of the sector, it clears BSY and 
    asserts INTRQ. If transfer of another sector is required, the drive also 
    sets DRQ.
 g) After detecting INTRQ, the host reads the Status Register.
 h) The drive clears the interrupt.
 i) If transfer of another sector is required, the above sequence is repeated 
    from d).

10.2.1  PIO Write Command

 +- a) -+-- b) -+      +--------+      +- e) -+--------+       +- e) -+
 |Setup | Issue |      |Transfer|      | Read |Transfer|       | Read |
 |      |Command|      |  Data  |      |Status|  Data  |:::::::|Status|
 +------+-------+      +--------+      +------+--------+       +------+
 |BSY=0 |       |BSY=1 |BSY=0   |BSY=1 |BSY=0 |        |BSY=1  |BSY=0 |
        |DRDY=1        |        |      |      |        |       |      |
                       |DRQ=1   |DRQ=0 |DRQ=1 |        |DRQ=0  |      |
                       |        |      |Assert|Negate  |       |Assert|Negate
                                        INTRQ  INTRQ            INTRQ  INTRQ 

10.2.2  PIO Write Aborted Command

 +- a) -+-- b) -+       +- e) -+
 |Setup | Issue |       | Read |
 |      |Command|       |Status|
 +------+-------+       +------+
 |BSY=0 |       |BSY=1  |BSY=0 |
        |DRDY=1         |      |
        |               |Assert|Negate
                         INTRQ  INTRQ 

10.3  Non-Data Commands

This class includes:

 - Execute Drive Diagnostic (DRDY=x)
 - Idle
 - Initialize Drive Parameters (DRDY=x)
 - Read Power Mode
 - Read Verify Sector(s)
 - Recalibrate
 - Seek
 - Set Features 
 - Set Multiple Mode
 - Standby

Execution of these commands involves no data transfer.

 a) The host writes any required parameters to the Features, Sector Count, 
    Sector Number, Cylinder and Drive/Head registers.
 b) The host writes the command code to the Command Register.
 c) The drive sets BSY. 
 d) When the drive has completed processing, it clears BSY and asserts INTRQ. 
 g) The host reads the Status Register.
 h) The drive negates INTRQ.

10.4  Miscellaneous Commands

This class includes:

 - Read Multiple
 - Sleep
 - Write Multiple
 - Write Same

The protocol for these commands is contained in the individual command 
descriptions.

10.5  DMA Data Transfer Commands (Optional)

This class comprises:

 - Read DMA
 - Write DMA

Data transfers using DMA commands differ in two ways from PIO transfers:

 - data transfers are performed using the slave-DMA channel 
 - no intermediate sector interrupts are issued on multi-sector commands 

Initiation of the DMA transfer commands is identical to the Read Sector or 
Write Sector commands except that the host initializes the slave-DMA channel 
prior to issuing the command.

The interrupt handler for DMA transfers is different in that:

 - no intermediate sector interrupts are issued on multi-sector commands
 - the host resets the DMA channel prior to reading status from the drive.

The DMA protocol allows high performance multi-tasking operating systems to 
eliminate processor overhead associated with PIO transfers. 

 a) Command Phase
    1) Host initializes the slave-DMA channel
    2) Host updates the Command Block Registers
    3) Host writes command code to the Command Register
 b) Data Phase - the register contents are not valid during a DMA Data Phase.
    1) The slave-DMA channel qualifies data transfers to and from the drive 
       with DMARQ
 c) Status Phase
    1) Drive generates the interrupt to the host
    2) Host resets the slave-DMA channel
    3) Host reads the Status Register and Error Register

10.5.1  Normal DMA Transfer

 +--------------+-------+      +---------------------+  +---------+------+
 |Initialize DMA|Command|      |  DMA Data Transfer  |  |Reset DMA|Status|
 +--------------+-------+      +---------------------+  +---------+------+
 |BSY=0                 |BSY=1 |BSY=x                   |BSY=1    |BSY=0
                               |DRQ=x                   |nIEN=0

10.5.2  Aborted DMA Transfer

 +--------------+-------+      +-------------+  +---------+------+
 |Initialize DMA|Command|      |    DMA Data |  |Reset DMA|Status|
 +--------------+-------+      +-------------+  +---------+------+
 |BSY=0                 |BSY=1 |BSY=x           |BSY=1    |BSY=0
                               |DRQ=1           |nIEN=0

10.5.3  Aborted DMA Command

 +--------------+-------+      +---------+------+
 |Initialize DMA|Command|      |Reset DMA|Status|
 +--------------+-------+      +---------+------+
 |BSY=0                 |BSY=1 |BSY=1    |BSY=0
                               |nIEN=0

11.  Timing

11.1  Deskewing

The host shall provide cable deskewing for all signals originating from the 
controller. The drive shall provide cable deskewing for all signals 
originating at the host. 

11.2  Symbols

Certain symbols are used in the timing diagrams. These symbols and their 
respective definitions are listed below.

 / or \    -  signal transition (asserted or negated) *
 < or >    -  data transition (asserted or negated)
 XXXXXX    -  undefined but not necessarily released
 .  .  .   -  the "other" condition if a signal is shown with no change
   #n      -  used to number the sequence in which events occur e.g. #a, #b
   _ _ __
__/_ _/    -  a degree of uncertainty as to when a signal may be asserted

__ _ _
  \_ _\__  -  a degree of uncertainty as to when a signal may be negated 

 * All signals are shown with the Asserted condition facing to the top of 
   the page. The negated condition is shown towards the bottom of the page 
   relative to the asserted condition. 

11.3  Terms

The interface uses a mixture of negative and positive signals for control and 
data. The terms asserted and negated are used for consistency and are 
independent of electrical characteristics. 

In all timing diagrams, the lower line indicates negated, and the upper line 
indicates asserted e.g. the following illustrates the representation of a 
signal named TEST going from negated to asserted and back to negated, based on 
the polarity of the signal. 

                              Assert          Negate
                                   |          | 
         Bit Setting=1             |__________|
         Bit Setting=0  TEST  _____/          \_______ 
 
                              Assert          Negate
                                   |          | 
         Bit Setting=0             |__________|
         Bit Setting=1  TEST- _____/          \_______ 

11.4  Data Transfers

Figure 11-1 defines the relationships between the interface signals for both 
16-bit and 8-bit data transfers. 

                              |<------------ t0 -------------------->|
                        __________________________________________   |
 Address Valid *1 ...../                                          \________
                       |<-t1->|                            ->| t9 |<-
                     ->|t7|<- |<----------- t2 ------------->|  ->|t8|<-
                       |  |   |______________________________|    |  |_____
 DIOR-/DIOW-      ____________/                              \_______/
                       |  |   |_ _ _ _ _ _ _ _ _ _ _____________     |
 Write Data Valid *2__________/_ _ _ _ _ _ _ _ _ _/             \__________
                       |  |   |                   |<--t3---->|  |  
                       |  |   |                            ->|t4|<-  |
                       |  |   |_ _ _ _ _ _ _ _ _ _ _ ___________     |
 Read Data Valid  *2__________/_ _ _ _ _ _ _ _ _ _ _/        |  \__________
                       |  |   |                     |<--t5-->|  |    |
                       |  |   |                            ->|t6|<-  | 
                       |  |   |                              |  |    |
                       |  |__________________________________________|
 IOCS16-          ________/                                          \_____

        *1  Drive Address consists of signals CS1FX-, CS3FX- and DA2-0 
        *2  Data consists of DD0-15 (16-bit) or DD0-7 (8-bit)

      +------------------------------------------+-------+-------+-------+
      | PIO                                      | Mode 0| Mode 1| Mode 2|
      | Timing Parameters                        |  nsec |  nsec |  nsec |
 +----+------------------------------------------+-------+-------+-------+
 | t0 | Cycle Time                         (Min) |  600  |  383  |  240  |
 | t1 | Address Valid to DIOR-/DIOW- Setup (Min) |   70  |   50  |   30  |
 | t2 | DIOR-/DIOW-      16-bit            (Min) |  165  |  125  |  100  |
 |    |   Pulse Width     8-bit            (Min) |  290  |  290  |  290  |
 | t3 | DIOW- Data Setup                   (Min) |   60  |   45  |   30  |
 | t4 | DIOW- Data Hold                    (Min) |   30  |   20  |   15  |
 | t5 | DIOR- Data Setup                   (Min) |   50  |   35  |   20  |
 | t6 | DIOR- Data Hold                    (Min) |    5  |    5  |    5  |
 | t7 | Addr Valid to IOCS16- Assertion    (Max) |   90  |   50  |   40  |
 | t8 | Addr Valid to IOCS16- Negation     (Max) |   60  |   45  |   30  |
 | t9 | DIOR-/DIOW- to Address Valid Hold  (Min) |   20  |   15  |   10  |
 +----+------------------------------------------+-------+-------+-------+

                 FIGURE 11-1:  PIO DATA TRANSFER TO/FROM DRIVE 

                        ___________________________________
 DIOR-/DIOW- __________/                                   \______________
                       | 
                       |<- tA ->|<---    tB    ---->|
             ___________________|                   |_____________________
 IORDY                          \___________________/

 Label               Description                          Min  Max  Units

 tA  IORDY  Setup time                                     -     35 nsecs 
 tB  IORDY  Pulse Width                                    -  1,250 nsecs 

  WARNING: The use of IORDY for data transfers is a system integration issue 
           which requires control of both ends of the cable.

                  FIGURE 11-2:  IORDY TIMING REQUIREMENTS

 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

                    |<----------------------- t0 ----------------------->|  
                 ____________                                         _______
 DMARQ       ___/            \_______________________________________/   |
                    |<- tC ->|                                           |   
                    |______________________________________________      |___ 
 DMACK-      _______/                                              \_____/  
                    |<--- tI --->|_________________|<----- tJ -----|     |   
 DIOR-/DIOW- ____________________/                 \_________________________
                    |            |                 |                     |   
                    |            |<------ tD ----->|                     |   
 Read               |                      _________________             |   
 DD0-15      -----------------------------<_________________>----------------
                    |            |<- tE ->|<- tS ->|<- tF ->|            |   
 Write              |                  __________________________        |   
 DD0-15     --------------------------<__________________________>-----------
                    |                 |            |             |       |  
                    |                 |<--- tG --->|<--  tH   -->|       |   

          +----------------------------------+-------+-------+-------+
          | Single Word DMA                  | Mode 0| Mode 1| Mode 2|
          | Timing Parameters                |  nsec |  nsec |  nsec |
     +----+----------------------------------+-------+-------+-------+
     | t0 | Cycle Time                 (Min) |  960  |  480  |  240  |
     | tC | DMACK to DMREQ Delay       (Max) |  200  |  100  |   80  |
     | tD | DIOR-/DIOW-      16-bit    (Min) |  480  |  240  |  120  |
     | tE | DIOR- Data Access          (Max) |  250  |  150  |   60  |
     | tF | DIOR- Data Hold            (Min) |    5  |    5  |    5  |
     | tG | DIOW- Data Setup           (Min) |  250  |  100  |   35  |
     | tH | DIOW- Data Hold            (Min) |   50  |   30  |   20  |
     | tI | DMACK to DIOR-/DIOW- Setup (Min) |    0  |    0  |    0  |
     | tJ | DIOR-/DIOW- to DMACK Hold  (Min) |    0  |    0  |    0  |
     | tS | DIOR- Setup                (Min) | tD-tE | tD-tE | tD-tE |
     +----+----------------------------------+-------+-------+-------+
                 FIGURE 11-3:  SINGLE WORD DMA DATA TRANSFER 

 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

                   |<-------------- t0 ---------------->|
            __________________________________________________            __
 DMARQ  ___/                                                  \__________/
                   |                                    |<--->|
                   |                                    |  tL
               __________________________________________________ 
 DMACK- ______/                                                  \_________/
              |<-->|         |                          |
                tI |<-- tD ->|<--------- tK ----------->|<- tJ ->|
                   |         |                          | 
 DIOR-             |_________|                          |_________
 DIOW-  ___________/         \__________________________/         \_________
 
                   |<--->|   |
 READ                 tE  ________                             ________
 DD0-15 -----------------<________>---------------------------<________>----
 
                             |<-->|
                             | tF
 WRITE                 ____________                         ____________
 DD0-15 --------------<____________>-----------------------<____________>---
 
                      |<---->|<--->|
                         tG    tH

                     +----------------------------+-----------+
                     | Multiword DMA              |   Mode 0  |
                     | Timing Parameters          |    nsec   |
                     |                            | Min | Max |
               +-----+----------------------------+-----+-----+
               | t0  | Cycle Time                 | 480 |     |
               | tC  | DMACK to DMREQ Delay       |     | --- |
               | tD  | DIOR-/DIOW-      16-bit    | 215 |     |
               | tE  | DIOR- Data Access          |     | 150 |
               | tF  | DIOR- Data Hold            |   5 |     |
               | tF  | DIOR- Data Hold            |     |  20 |
               | tG  | DIOW- Data Setup           | 100 |     |
               | tH  | DIOW- Data Hold            |  20 |     |
               | tI  | DMACK to DIOR-/DIOW- Setup |   0 |     |
               | tJ  | DIOR-/DIOW- to DMACK Hold  |   0 |     |
               | tKr | DIOR- Negated Pulse Width  |  50 |     |
               | tKw | DIOW- Negated Pulse Width  | 215 |     |
               | tLr | DIOR- to DMREQ Delay       |     | 120 |
               | tLw | DIOW- to DMREQ Delay       |     |  40 |
               +-----+----------------------------+-----+-----+
                  FIGURE 11-4:  MULTIWORD DMA DATA TRANSFER 

11.5 Power On and Hard Reset

              ______ 
 RESET- _____/      \_____________________________________________________
             |<-tM->| 
             |      |          Drive 0 
          _ _ _ _ _ _ _ _______ _ _ _ _ _ _ _ _ _ _ _ _ _| 
 BSY      _ _ _ _ _ _ _/       \_ _ _ _ _ *1  _ _ _ _ _ _\________________
                  ->|tN|<-
          _ _ _ _ _ _ _ _         _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 
 DASP-    _ _ _ _ _ _ _ _\_______/_ _ _ _ *2 _ _ _ _ _ _ _ _ _ _\=== *3 ==
                  ->| tP |<-     |                       |_ _ _ __________
 Control Registers_______________________________________/_ _ _ / 
                    |  | | 
                    |  | |     Drive 1 
        _ _ _ _ _ _ _ _ _________________________________| 
 BSY    _ _ _ _ _ _ _ _/                                 \________________
         _ _ _ _ _ _ _ _ _ _                              ______ _ _ _ _ _
 PDIAG-  _ _ _ _ _ _ _ _ _ _\____________________________/      \_ _ _ _ _
                    |  | |     |<----------- tQ -------->| 
        _ _ _ _ _ _ _ _ _       _________________________ _ _ _ 
 DASP-  _ _ _ _ _ _ _ _ _\_____/                         \ _ _ _\=== *3 ==
                    |<-  tR  ->|<------------ tS -------------->| 
                                                          _ _ _ __________
 Control Registers_______________________________________/_ _ _ /

     *1 Drive 0 can set BSY=0 if Drive 1 not present
     *2 Drive 0 can use DASP- to indicate it is active if Drive 1 is not 
        present
     *3 DASP- can be asserted to indicate that the drive is active
                      +-------------------+------------+
                      | Label             |   Units    |
                      +-------------------+------------+
                      | tM         (Min)  |  25   usec |
                      | tN         (Max)  | 400   nsec |
                      | tP         (Max)  |   1   msec |
                      | tQ         (Max)  |  30   secs |
                      | tR Drive 0 (Max)  | 450   msec |
                      | tR Drive 1 (Max)  | 400   msec |
                      | tS         (Max)  |  30.5 secs |
                      +-------------------+------------+

                         FIGURE 11-5:  RESET SEQUENCE

Annex A: Diagnostic and Reset Considerations 
         (informative). 

This annex describes the following timing relationships during:

 a) Power On and Hardware Resets 
    - One drive 
    - Two drives 
 b) Software Reset 
    - One drive 
    - Two drives 
 c) Diagnostic Command Execution 
    - One drive 
    - Two drives 
    - Two drives - Drive 1 failed 

The timing assumes the following: 

 o DASP- is asserted by Drive 1 and received by Drive 0 at power-on or 
   hardware reset to indicate the presence of Drive 1. At all other times it 
   is asserted by Drive 0 and Drive 1 to indicate when a drive is active. 
 o PDIAG- is asserted by Drive 1 and detected by Drive 0. It is used by 
   Drive 1 to indicate to Drive 0 that it has completed diagnostics and is 
   ready to accept commands from the Host (BSY bit is cleared). This does not 
   indicate that the drive is ready, only that it can accept commands. This 
   line may remain asserted until the next reset occurs or an Execute 
   Diagnostic command is received. 
 o Unless indicated otherwise, all times are relative to the event that 
   triggers the operation (RESET-, SRST=1, Execute Diagnostic Command). 

A.1 Power On and Hardware Resets 

A.1.1 Power On and Hardware Resets - One Drive 

 - Host asserts RESET- for a minimum of 25 usec. 
 - Drive 0 sets BSY within 400 nsecs after RESET- is negated. 
 - Drive 0 negates DASP- within 1 msec after RESET- negated. 
 - Drive 0 performs hardware initialization 
 - Drive 0 may revert to its default condition 
 - Drive 0 waits 1 msec then samples for at least 450 msec for DASP- to be 
   asserted from Drive 1. 
 - Drive 0 clears BSY when ready to accept commands (within 31 seconds). 

A.1.2  Power On and Hardware Resets - Two Drives 

 - Host asserts RESET- for a minimum of 25 usec. 
 - Drive 0 and Drive 1 set BSY within 400 nsec after RESET- negated. 
 - DASP- is negated within 1 msec after RESET- is negated. 

A.1.2.1  Drive 1 

 - Drive 1 negates PDIAG- before asserting DASP-.
 - Drive 1 asserts DASP- within 400 msecs after RESET- (to show presence). 
 - Drive 1 performs hardware initialization and executes its internal 
   diagnostics. 
 - Drive 1 may revert to its default condition 
 - Drive 1 posts diagnostic results to the Error Register 
 - Drive 1 clears BSY when ready to accept commands. 
 - Drive 1 asserts PDIAG- to indicate that it is ready to accept commands 
   (within 30 seconds from RESET-). 
 - Drive 1 negates DASP- after the first command is received or negates DASP- 
   if no command is received within 30 seconds after RESET-. 

A.1.2.2  Drive 0 

 - Drive 0 performs hardware initialization and executes its internal 
   diagnostics. 
 - Drive 0 may revert to its default condition 
 - Drive 0 posts diagnostic results to the Error Register 
 - After 1 msec, Drive 0 waits at least 450 msec for DASP- to be asserted 
   (from Drive 1). If DASP- is not asserted, no Drive 1 is present (see POWER-
   ON RESET - One Drive operation). 
 - Drive 0 waits up to 31 seconds for Drive 1 to assert PDIAG-. If PDIAG- is 
   not asserted, Drive 0 sets Bit 7=1 in the Error Register. 
 - Drive 0 clears BSY when ready to accept commands (within 31 seconds). 

A.2  Software Reset 

A.2.1  Software Reset - One Drive 

 - Host sets SRST=1 in the Device Control Register. 
 - Drive 0 sets BSY within 400 nsec after detecting that SRST=1. 
 - Drive 0 performs hardware initialization and executes its internal 
   diagnostics. 
 - Drive 0 may revert to its default condition. 
 - Drive 0 posts diagnostic results to the Error Register. 
 - Drive 0 clears BSY when ready to accept commands (within 31 seconds). 

A.2.2  Software Reset - Two Drives 

 - Host sets SRST=1 in the Device Control Register. 
 - Drive 0 and Drive 1 set BSY within 400 nsec after detecting that SRST=1.
 - Drive 0 and Drive 1 perform hardware initialization.
 - Drive 0 and Drive 1 may revert to their default condition.

A.2.2.1  Drive 1 

 - Drive 1 negates PDIAG- within 1 msec. 
 - Drive 1 clears BSY when ready to accept commands. 
 - Drive 1 asserts PDIAG- to indicate that it is ready to accept commands 
   (within 30 seconds). 

A.2.2.2  Drive 0 

 - Drive 0 waits up to 31 seconds for Drive 1 to assert PDIAG-. 
 - Drive 0 clears BSY when ready to accept commands (within 31 seconds). 

A.3  Diagnostic Command Execution 

A.3.1  Diagnostic Command Execution - One Drive (Passed) 
 
 - Drive 0 sets BSY within 400 nsec after the Execute Diagnostic command was 
   received. 
 - Drive 0 performs hardware initialization and internal diagnostics. 
 - Drive 0 resets Command Block registers to default condition. 
 - Drive 0 posts diagnostic results to the Error Register 
 - Drive 0 clears BSY when ready to accept commands (within 6 seconds). 

A.3.2  Diagnostic Command - Two Drives (Passed) 

 - Drive 0 and Drive 1 set BSY within 400 nsec after the Execute Diagnostic 
   command was received. 

A.3.2.1  Drive 1 

 - Drive 1 negates PDIAG- within 1 msec after command received. 
 - Drive 1 performs hardware initialization and internal diagnostics. 
 - Drive 1 resets the Command Block registers to their default condition. 
 - Drive 1 posts diagnostic results to the Error Register 
 - Drive 1 clears BSY when ready to accept commands. 
 - Drive 1 asserts PDIAG- to indicate that it is ready to accept commands 
   (within 5 seconds). 

A.3.2.2  Drive 0 

 - Drive 0 performs hardware initialization and internal diagnostics. 
 - Drive 0 resets the Command Block registers to their default condition. 
 - Drive 0 waits up to <5 seconds for Drive 1 to assert PDIAG-. 
 - Drive 0 posts diagnostic results to the Error Register 
 - Drive 0 clears BSY when ready to accept commands (within 6 seconds). 

A.3.3  Diagnostic Command Execution - One Drive (Failed) 

 - Drive 0 sets BSY within 400 nsec after Diagnostic command received. 
 - Drive 0 performs hardware initialization and internal diagnostics. 
 - Drive 0 resets Command Block registers to default condition. 
 - Drive 0 posts a Diagnostic Code to the Error Register indicating a failure. 
 - Drive 0 clears BSY when ready to accept commands (within 6 seconds) 

A.3.4  Diagnostic Command Execution - Two Drives (Drive 1 Failed) 

 - Drive 0 and Drive 1 set BSY within 400 nsec after Diagnostic command 
   received. 

A.3.4.1  Drive 1 

 - Drive 1 negates PDIAG- within 1 msec after command received. 
 - Drive 1 performs hardware initialization and internal diagnostics. 
 - Drive 1 resets the Command Block registers to their default condition. 
 - Drive 1 posts a Diagnostic Code to the Error Register indicating failure. 
 - Drive 1 clears BSY. 
 - Drive 1 does not assert PDIAG-, indicating that it failed diagnostics. 

A.3.4.2  Drive 0 

 - Drive 0 performs hardware initialization and internal diagnostics. 
 - Drive 0 resets the Command Block registers to their default condition. 
 - Drive 0 waits 6 seconds for Drive 1 to assert PDIAG- but PDIAG- is not 
   asserted by Drive 1. 
 - Drive 0 posts a Diagnostic Code to the Error Register setting Bit 7=1 to 
   indicate that Drive 1 failed diagnostics.
 - Drive 0 clears BSY when ready to accept commands (within 6 seconds). 

  NOTE: The 6 seconds referenced above is a host-oriented value. 

Annex B: Diagnostic and Reset Considerations  
         (informative). 

B.1  Power on and hardware reset (RESET-) 

DASP- is read by Drive 0 to determine if Drive 1 is present. If Drive 1 is 
present Drive 0 will read PDIAG- to determine when it is valid to clear BSY 
and whether Drive 1 has powered on or reset without error, otherwise Drive 0 
clears BSY whenever it is ready to accept commands. Drive 0 may assert DASP- 
to indicate drive activity.

B.2  Software reset 

If Drive 1 is present Drive 0 will read PDIAG- to determine when it is valid 
to clear BSY and whether Drive 1 has reset without any errors, otherwise 
Drive  0 will simply reset and clear BSY.  DASP- is asserted by Drive 0 (and 
Drive 1 if it is present) in order to indicate drive active. 

B.3  Drive Diagnostic Command 

If Drive 1 is present, Drive 0 will read PDIAG- to determine when it is valid 
to clear BSY and if Drive 1 passed or failed the Execute Drive Diagnostic 
command, otherwise Drive 0 will simply execute its diagnostics and then clear 
BSY.  DASP- is asserted by Drive 0 (and Drive 1 if it is present) in order to 
indicate the drive is active. 

B.4  Truth Table 

In all the above cases:  Power on, RESET-, software reset, and the Execute 
Drive Diagnostics command the Drive 0 Error Register is calculated as follows: 

        Drive 1           PDIAG-         Drive 0         Error 
        Present?        Asserted?        Passed        Register 

          Yes             Yes             Yes           01h 
          Yes             Yes              No           0xh 
          Yes              No             Yes           81h 
          Yes              No              No           8xh 
           No           (not read)        Yes           01h 
           No           (not read)         No           0xh 

Where x indicates the appropriate Diagnostic Code for the Power on, RESET-, 
software reset, or drive diagnostics error. 

B.5  Power On or Hardware Reset Algorithm  

 1) Power on or hardware reset 
 2) The hardware should automatically do the following: 
         a) Set up the hardware to post both Drive 0 and Drive 1 status 
         b) Set the Drive 0 Status Register to 80h (set BSY and clear 
            all the other status bits) 
         c) Set the Drive 1 Status Register to 80h (set BSY and clear all 
            the other status bits) 
 3) Read the single Drive 0/Drive 1 jumper and note its state 
 4) Perform any remaining time critical hardware initialization including 
    starting the spin up of the disk if needed 
 5) If Drive 1 
         a) Negate the PDIAG- signal 
         b) Set up PDIAG- as an output 
         c) Assert the DASP- output 
         d) Set up DASP- as an output if necessary 
         e) Set up the hardware so it posts Drive 1 status only and 
            continue to post 80h for Drive 1 status 
         NOTE: all this must happen within 400 msec after power on or RESET- 
    If Drive 0 
         a) Set up PDIAG- as an input 
         b) Release DASP- and set up DASP- as an input 
         c) Test DASP- for 450 msec or until DASP- is asserted by Drive 1 
         d) If DASP- is asserted within 450 msec 
                 i)   Note that Drive 1 is present 
                 ii)  Set up the hardware so it posts Drive 0 status only 
                      and continue to post 80h for the Drive 0 status 
            If DASP- is not asserted within 450 msec 
                    i)   note that Drive 1 is not present
         e) Assert DASP- to indicate drive activity 
 6) Complete all the hardware initialization needed to get the drive ready, 
    including: 
         a) Set the Sector Count Register to 01h 
         b) Set the Sector Number Register to 01h 
         c) Set the Cylinder Low Register to 00h 
         d) Set the Cylinder High Register to 00h 
         e) Set the Drive/Head Register to 00h 
 7) If Drive 1 and power on, or RESET- is valid 
         a) Set the Error Register to Diagnostic Code 01h 
         b) Set the Drive 1 Status Register to 00h 
         c) Assert PDIAG- 
         NOTE:  All this must happen within 5 seconds of power on or the 
                negation of RESET- 
    If Drive 1 and power on or RESET- bad 
         a) Set the Error Register to the appropriate Diagnostic Code 
         b) Set the Drive 1 Status Register to 00h 
         NOTE:  All this must happen within 5 seconds of power on or the 
                negation of RESET- 
    If Drive 0, power on or RESET- valid, and a Drive 1 is present 
         a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by Drive 1 
         b) If PDIAG- is asserted within 6 seconds 
                 i)  Set the Error Register to Diagnostic Code 01h 
         c) If PDIAG- is not asserted within 6 seconds 
                 i)  Set the Error Register to 81h 
         d) Set the Drive 0 Status Register to 00h 
    If Drive 0, power on or RESET- bad, and a Drive 1 is present 
         a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by 
            Drive 1 
         b) If PDIAG- is asserted within 6 seconds 
                 i)  Set the Error Register to the appropriate Diagnostic Code 
         c) If PDIAG- is not asserted within 6 seconds 
                 i)  Set the Error Register to 80h + the appropriate code 
         d) Set the Drive 0 Status Register to 00h 
    If Drive 0, power on or RESET- valid, and no Drive 1 is present 
         a) Set the Error Register to Diagnostic Code 01h 
         b) Set the Drive 1 Status Register to 00h 
         c) Set the Drive 0 Status Register to 00h 
    If Drive 0, power on or RESET- bad, and no Drive 1 is present 
         a) Set the Error Register to the appropriate Diagnostic Code 
         b) Set the Drive 1 Status Register to 00h 
         c) Set the Drive 0 Status Register to 00h 
 8) Finish spin up if needed 
 9) If Drive 1 
         a) Set the Drive 1 Status Register to 50h 
         b) Negate DASP- if a command is not received within 30 seconds 
    If Drive 0 and a Drive 1 is present 
         a) Set the Drive 0 Status Register to 50h 
         b) Negate DASP- 
    If Drive 0 and no Drive 1 is present 
         a) Leave the Drive 1 Status Register 00h 
         b) Set the Drive 0 Status Register to 50h 
         c) Negate DASP- 

B.6  Software Reset Algorithm 

 1) The software reset bit is set 
 2) If Drive 1 
         a) The hardware should set BUSY in the Drive 1 Status Register 
         b) Negate the PDIAG- signal 
         NOTE: this must happen within 1 msec of the software reset 
    If Drive 0 and Drive 1 is present 
            a) The hardware should set BUSY in the Drive 0 Status Register 
    If Drive 0 and there is no Drive 1 the hardware should: 
            a) Set BUSY in the Drive 0 Status Register 
         b) Set the Drive 1 Status Register to 80h 
 3) Assert DASP- 
 4) Finish all the hardware initialization needed to place the drive in reset 
 5) Wait for the software reset bit to clear 
 6) Finish all hardware initialization needed to get the drive ready 
    to receive any type of command from the host including: 
         a) Set the Sector Count Register to 01h 
         b) Set the Sector Number Register to 01h 
         c) Set the Cylinder Low Register to 00h 
         d) Set the Cylinder High Register to 00h 
         e) Set the Drive/Head Register to 00h 
 7) If Drive 1 and reset valid 
         a) Set the Error Register to Diagnostic Code 01h 
         b) Set the Drive 1 Status Register to 50h 
         c) Assert PDIAG- 
         NOTE:  All this must happen within 5 seconds of the clearing of 
                the software reset bit 
    If Drive 1 and reset bad 
         a) Set the Error Register to the appropriate Diagnostic Code 
         b) Set the Drive 1 Status Register to 50h 
         NOTE:  All this must happen within 5 seconds of the clearing of 
                the software reset bit 
    If Drive 0, reset valid, and a Drive 1 is present 
            a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by 
            Drive 1 
            b) If PDIAG- is asserted within 6 seconds 
                 i)  Set the Error Register to Diagnostic Code 01h 
         c) If PDIAG- is not asserted within 6 seconds 
                 i)  Set the Error Register to 81h 
         d) Set the Drive 0 Status Register to 50h 
    If Drive 0, reset bad, and a Drive 1 is present 
            a) Test PDIAG- for 31 seconds or until PDIAG- is asserted by
            Drive 1 
            b) If PDIAG- is asserted within 31 seconds 
                 i)  Set the Error Register to the appropriate Diagnostic Code 
         c) If PDIAG- is not asserted within 31 seconds 
                 i)  Set the Error Register to 80h + the appropriate code 
         d) Set the Drive 0 Status Register to 50h 
    If Drive 0, reset valid, and no Drive 1 is present 
            a) Set the Error Register to Diagnostic Code 01h 
         b) Set the Drive 1 Status Register to 00h 
            c) Set the Drive 0 Status Register to 50h 
    If Drive 0, reset bad, and no Drive 1 is present 
            a) Set the Error Register to the appropriate Diagnostic Code 
         b) Set the Drive 1 Status Register to 00h 
            c) Set the Drive 0 Status Register to 50h 

B.7  Diagnostic Command Algorithm 

 1) The diagnostics command is received 
 2) If Drive 1 
         a) The hardware should set BUSY in the Drive 1 Status Register 
         b) Negate the PDIAG- signal 
         NOTE: this must happen within 1 msec after command acceptance 
    If Drive 0 and Drive 1 is present 
            a) The hardware should set BUSY in the Drive 0 Status Register 
    If Drive 0 and there is no Drive 1 the hardware should 
            a) Set BUSY in the Drive 0 Status Register 
         b) Set BUSY in the Drive 1 Status Register 
 3) Assert DASP- 
 4) Perform all the drive diagnostics and note their results 
 5) Finish all the hardware initialization needed to get the drive ready 
    to receive any type of command from the host including: 
         a) Set the Sector Count Register to 01h 
         b) Set the Sector Number Register to 01h 
         c) Set the Cylinder Low Register to 00h 
         d) Set the Cylinder High Register to 00h 
         e) Set the Drive/Head Register to 00h 
 6) If Drive 1 and passed 
         a) Set the Error Register to Diagnostic Code 01h 
         b) Set the Drive 1 status to 50h 
         c) Assert PDIAG- 
         NOTE:  All this must happen within 5 seconds of the acceptance 
                of the diagnostic command 
    If Drive 1 and did not pass 
            a) Set the Error Register to the appropriate Diagnostic Code 
         b) Set the Drive 1 status to 50h 
         NOTE:  All this must happen within 5 seconds of the acceptance 
                of the diagnostic command 
    If Drive 0, passed, and a Drive 1 is present 
            a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by 
            Drive 1 
            b) If PDIAG- is asserted within 6 seconds 
                 i)  Set the Error Register to Diagnostic Code 01h 
         c) If PDIAG- is not asserted within 6 seconds 
                 i)  Set the Error Register to 81h 
         d) Set the Drive 0 status to 50h 
         e) Issue interrupt to the host 
    If Drive 0, did not pass, and a Drive 1 is present 
         a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by Drive 1 
         b) If PDIAG- is asserted within 6 seconds 
                 i)  Set the Error Register to the appropriate Diagnostic Code 
         c) If PDIAG- is not asserted within  seconds 
                 i)  Set the Error Register to 80h + the appropriate code 
         d) Set the Drive 0 Status Register to 50h 
         e) Issue interrupt to the host 
    If Drive 0, passed, and no Drive 1 is present 
         a) Set the Error Register to Diagnostic Code 01h 
         b) Set the Drive 1 Status Register to 00h 
         c) Set the Drive 0 Status Register to 50h 
         d) Issue interrupt to the host 
    If Drive 0, did not pass, and no Drive 1 is present 
         a) Set the Error Register to the appropriate Diagnostic Code 
         b) Set the Drive 1 Status Register to 00h 
         c) Set the Drive 0 Status Register to 50h 
         d) Issue interrupt to the host 

Annex C: Small Form Factor Connectors
         (informative). 

This annex describes the connector-connector mating alternatives for 2 1/2" 
disk drives or smaller which were developed by the Small Form Factor (SFF) 
Committee, an industry ad hoc group. 

In an effort to broaden the applications for small form factor disk drives, a 
group of companies representing system integrators, peripheral suppliers, and 
component suppliers decided to address the issues involved. 

A primary purpose of the SFF Committee was to define the external dimensions 
of small form factor disk drives so that products from different vendors could 
be used in the same mounting configurations. 

The restricted area, and the mating of drives directly to a motherboard 
required that the number of connectors be reduced, which caused the assignment 
of additional pins for power. Power is provided to the drives on the same 
connector as used for the signals, and addresses are set by the receptacle 
into which the drives are plugged. 

The 50-pin connector that has been widely adopted across industry for SFF 
drives is a low density 2mm connector which has no shroud on the plug which is 
mounted on the drive. A number of suppliers provide intermatable components. 
The following information has been provided to assist users in specifying 
components used in an implementation. 

      Signals Connector Plug               DuPont 86451 or equivalent
      Signals Connector Receptacle         DuPont 86455 or equivalent

C.1  44-pin Signal Assignments 

The signals assigned for 44-pin applications are described in Table C-1. 
Although there are 50 pins in the plug, the mating receptacle need contain 
only 44 pins (the removal of pins E and F provides room for the wall of the 
receptacle).

44-pin Signal Assignments for ATA 

The first four pins of the connector plug located on the drive are not to be 
connected to the host, as they are reserved for manufacturer's use. Pins E, 
F and K are keys, and are removed. 

            +-------------------------------------------1-E-----+ 
            | o o o o o o o o o o o o o o o o o o o o o o K C A | 
            | o o o o o o o o o o o o K o o o o o o o o o K D B | 
            +44----------------------20-----------------2-F-----+ 
 
                    TABLE C-1  SIGNAL ASSIGNMENTS FOR ATA 
 ====================================================================== 
      Signal        Connector              Connector      Signal 
       Name          Contact   Conductor    Contact        Name 
 ====================================================================== 
     Vendor Unique      A                      B         Vendor Unique 
     Vendor Unique      C                      D         Vendor Unique 
     (keypin)           E                      F         (keypin) 
     RESET-             1        1 |  2        2         Ground 
     DD7                3        3 |  4        4         DD8 
     DD6                5        5 |  6        6         DD9 
     DD5                7        7 |  8        8         DD10 
     DD4                9        9 | 10       10         DD11 
     DD3               11       11 | 12       12         DD12 
     DD2               13       13 | 14       14         DD13 
     DD1               15       15 | 16       16         DD14 
     DD0               17       17 | 18       18         DD15 
     Ground            19       19 | 20       20         (keypin) 
     DMARQ             21       21 | 22       22         Ground 
     DIOW-             23       23 | 24       24         Ground 
     DIOR-             25       25 | 26       26         Ground 
     IORDY             27       27 | 28       28         PSYNC:CSEL 
     DMACK-            29       29 | 30       30         Ground 
     INTRQ             31       31 | 32       32         IOCS16-
     DA1               33       33 | 34       34         PDIAG-
     DAO               35       35 | 36       36         DA2 
     CS1FX-            37       37 | 38       38         CS3FX-
     DASP-             39       39 | 40       40         Ground 
  *  +5V (Logic)       41       41 | 42       42         +5V (Motor)     *
  *  Ground (Return)   43       43 | 44       44         TYPE- (0=ATA)   *
         * Pins which are additional to those of the 40-pin cable.
 ======================================================================