💾 Archived View for gemini.bortzmeyer.org › rfc-mirror › rfc4037.txt captured on 2021-12-04 at 18:04:22.

View Raw

More Information

⬅️ Previous capture (2021-11-30)

-=-=-=-=-=-=-







Network Working Group                                        A. Rousskov
Request for Comments: 4037                       The Measurement Factory
Category: Standards Track                                     March 2005


    Open Pluggable Edge Services (OPES) Callout Protocol (OCP) Core

Status of This Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2005).

Abstract

   This document specifies the core of the Open Pluggable Edge Services
   (OPES) Callout Protocol (OCP).  OCP marshals application messages
   from other communication protocols: An OPES intermediary sends
   original application messages to a callout server; the callout server
   sends adapted application messages back to the processor.  OCP is
   designed with typical adaptation tasks in mind (e.g., virus and spam
   management, language and format translation, message anonymization,
   or advertisement manipulation).  As defined in this document, the OCP
   Core consists of application-agnostic mechanisms essential for
   efficient support of typical adaptations.

Table of Contents

   1.  Introduction . . . . . . . . . . . . . . . . . . . . . . . . .  3
       1.1.  Scope  . . . . . . . . . . . . . . . . . . . . . . . . .  4
       1.2.  OPES Document Map  . . . . . . . . . . . . . . . . . . .  5
       1.3.  Terminology  . . . . . . . . . . . . . . . . . . . . . .  6
   2.  Overall Operation  . . . . . . . . . . . . . . . . . . . . . .  7
       2.1.  Initialization . . . . . . . . . . . . . . . . . . . . .  7
       2.2.  Original Dataflow  . . . . . . . . . . . . . . . . . . .  8
       2.3.  Adapted Dataflow . . . . . . . . . . . . . . . . . . . .  8
       2.4.  Multiple Application Messages  . . . . . . . . . . . . .  9
       2.5.  Termination  . . . . . . . . . . . . . . . . . . . . . .  9
       2.6.  Message Exchange Patterns  . . . . . . . . . . . . . . .  9
       2.7.  Timeouts . . . . . . . . . . . . . . . . . . . . . . . . 10
       2.8.  Environment  . . . . . . . . . . . . . . . . . . . . . . 11
   3.  Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . 11



Rousskov                    Standards Track                     [Page 1]

RFC 4037               OPES Callout Protocol Core             March 2005


       3.1.  Message Format . . . . . . . . . . . . . . . . . . . . . 12
       3.2.  Message Rendering  . . . . . . . . . . . . . . . . . . . 13
       3.3.  Message Examples . . . . . . . . . . . . . . . . . . . . 14
       3.4.  Message Names  . . . . . . . . . . . . . . . . . . . . . 15
   4.  Transactions . . . . . . . . . . . . . . . . . . . . . . . . . 15
   5.  Invalid Input  . . . . . . . . . . . . . . . . . . . . . . . . 16
   6.  Negotiation  . . . . . . . . . . . . . . . . . . . . . . . . . 16
       6.1.  Negotiation Phase  . . . . . . . . . . . . . . . . . . . 17
       6.2.  Negotiation Examples . . . . . . . . . . . . . . . . . . 18
   7.  'Data Preservation' Optimization . . . . . . . . . . . . . . . 20
   8.  'Premature Dataflow Termination' Optimizations . . . . . . . . 21
       8.1.  Original Dataflow  . . . . . . . . . . . . . . . . . . . 22
       8.2.  Adapted Dataflow . . . . . . . . . . . . . . . . . . . . 23
       8.3.  Getting Out of the Loop  . . . . . . . . . . . . . . . . 24
   9.  Protocol Element Type Declaration Mnemonic (PETDM) . . . . . . 25
       9.1     Optional Parameters  . . . . . . . . . . . . . . . . . 27
   10. Message Parameter Types  . . . . . . . . . . . . . . . . . . . 28
       10.1.   uri. . . . . . . . . . . . . . . . . . . . . . . . . . 28
       10.2.   uni. . . . . . . . . . . . . . . . . . . . . . . . . . 28
       10.3.   size . . . . . . . . . . . . . . . . . . . . . . . . . 29
       10.4.   offset . . . . . . . . . . . . . . . . . . . . . . . . 29
       10.5.   percent  . . . . . . . . . . . . . . . . . . . . . . . 29
       10.6.   boolean. . . . . . . . . . . . . . . . . . . . . . . . 30
       10.7.   xid .  . . . . . . . . . . . . . . . . . . . . . . . . 30
       10.8.   sg-id. . . . . . . . . . . . . . . . . . . . . . . . . 30
       10.9.   modp. . . . . . . . . . . . . . . . . . . . . . . . .  30
       10.10.  result. . . . . . . . . . . . . . . . . . . . . . . .  30
       10.11.  feature . . . . . . . . . . . . . . . . . . . . . . .  32
       10.12.  features. . . . . . . . . . . . . . . . . . . . . . .  32
       10.13.  service . . . . . . . . . . . . . . . . . . . . . . .  32
       10.14.  services. . . . . . . . . . . . . . . . . . . . . . .  33
       10.15.  Dataflow Specializations. . . . . . . . . . . . . . .  33
   11. Message Definitions . . . . . . . . . . . . . . . . . . . . .  33
       11.1.   Connection Start (CS) . . . . . . . . . . . . . . . .  34
       11.2.   Connection End (CE) . . . . . . . . . . . . . . . . .  35
       11.3.   Service Group Created (SGC) . . . . . . . . . . . . .  35
       11.4.   Service Group Destroyed (SGD) . . . . . . . . . . . .  36
       11.5.   Transaction Start (TS). . . . . . . . . . . . . . . .  36
       11.6.   Transaction End (TE). . . . . . . . . . . . . . . . .  36
       11.7.   Application Message Start (AMS) . . . . . . . . . . .  37
       11.8.   Application Message End (AME) . . . . . . . . . . . .  37
       11.9.   Data Use Mine (DUM) . . . . . . . . . . . . . . . . .  38
       11.10.  Data Use Yours (DUY). . . . . . . . . . . . . . . . .  39
       11.11.  Data Preservation Interest (DPI). . . . . . . . . . .  39
       11.12.  Want Stop Receiving Data (DWSR) . . . . . . . . . . .  40
       11.13.  Want Stop Sending Data (DWSS) . . . . . . . . . . . .  41
       11.14.  Stop Sending Data (DSS) . . . . . . . . . . . . . . .  41
       11.15.  Want Data Paused (DWP). . . . . . . . . . . . . . . .  42



Rousskov                    Standards Track                     [Page 2]

RFC 4037               OPES Callout Protocol Core             March 2005


       11.16.  Paused My Data (DPM). . . . . . . . . . . . . . . . .  43
       11.17.  Want More Data (DWM). . . . . . . . . . . . . . . . .  43
       11.18.  Negotiation Offer (NO). . . . . . . . . . . . . . . .  44
       11.19.  Negotiation Response (NR) . . . . . . . . . . . . . .  45
       11.20.  Ability Query (AQ). . . . . . . . . . . . . . . . . .  46
       11.21.  Ability Answer (AA) . . . . . . . . . . . . . . . . .  46
       11.22.  Progress Query (PQ) . . . . . . . . . . . . . . . . .  47
       11.23.  Progress Answer (PA). . . . . . . . . . . . . . . . .  47
       11.24.  Progress Report (PR). . . . . . . . . . . . . . . . .  48
   12. IAB Considerations  . . . . . . . . . . . . . . . . . . . . .  48
   13. Security Considerations . . . . . . . . . . . . . . . . . . .  48
   14. IANA Considerations . . . . . . . . . . . . . . . . . . . . .  50
   15. Compliance  . . . . . . . . . . . . . . . . . . . . . . . . .  50
       15.1.  Extending OCP Core . . . . . . . . . . . . . . . . . .  51
   A.  Message Summary . . . . . . . . . . . . . . . . . . . . . . .  52
   B.  State Summary   . . . . . . . . . . . . . . . . . . . . . . .  53
   C.  Acknowledgements  . . . . . . . . . . . . . . . . . . . . . .  54
   16. References  . . . . . . . . . . . . . . . . . . . . . . . . .  54
       16.1.  Normative References . . . . . . . . . . . . . . . . .  54
       16.2.  Informative References . . . . . . . . . . . . . . . .  54
   Author's Address. . . . . . . . . . . . . . . . . . . . . . . . .  55
   Full Copyright Statement. . . . . . . . . . . . . . . . . . . . .  56

1.  Introduction

   The Open Pluggable Edge Services (OPES) architecture [RFC3835]
   enables cooperative application services (OPES services) between a
   data provider, a data consumer, and zero or more OPES processors.
   The application services under consideration analyze and possibly
   transform application-level messages exchanged between the data
   provider and the data consumer.

   The OPES processor can delegate the responsibility of service
   execution by communicating with callout servers.  As described in
   [RFC3836], an OPES processor invokes and communicates with services
   on a callout server by using an OPES callout protocol (OCP).  This
   document specifies the core of that protocol ("OCP Core").

   The OCP Core specification documents general application-independent
   protocol mechanisms.  A separate series of documents describes
   application-specific aspects of OCP.  For example, "HTTP Adaptation
   with OPES" [OPES-HTTP] describes, in part, how HTTP messages and HTTP
   meta-information can be communicated over OCP.

   Section 1.2 provides a brief overview of the entire OPES document
   collection, including documents describing OPES use cases and
   security threats.




Rousskov                    Standards Track                     [Page 3]

RFC 4037               OPES Callout Protocol Core             March 2005


1.1.  Scope

   The OCP Core specification documents the behavior of OCP agents and
   the requirements for OCP extensions.  OCP Core does not contain
   requirements or mechanisms specific for application protocols being
   adapted.

   As an application proxy, the OPES processor proxies a single
   application protocol or converts from one application protocol to
   another.  At the same time, OPES processor may be an OCP client,
   using OCP to facilitate adaptation of proxied messages at callout
   servers.  It is therefore natural to assume that an OPES processor
   takes application messages being proxied, marshals them over OCP to
   callout servers, and then puts the adaptation results back on the
   wire.  However, this assumption implies that OCP is applied directly
   to application messages that OPES processor is proxying, which may
   not be the case.

      OPES processor scope                         callout server scope
      +-----------------+                           +-----------------+
      | pre-processing  |         OCP scope         |                 |
      |            +- - - - - - - - - - - - - - - - - - -+            |
      | iteration  |     <== ( application data ) ==>    | adaptation |
      |            +- - - - - - - - - - - - - - - - - - -+            |
      | post-processing |                           |                 |
      +-----------------+                           +-----------------+

   An OPES processor may preprocess (or postprocess) proxied application
   messages before (or after) they are adapted at callout servers.  For
   example, a processor may take an HTTP response being proxied and pass
   it as-is, along with metadata about the corresponding HTTP
   connection.  Another processor may take an HTTP response, extract its
   body, and pass that body along with the content-encoding metadata.
   Moreover, to perform adaptation, the OPES processor may execute
   several callout services, iterating over several callout servers.
   Such preprocessing, postprocessing, and iterations make it impossible
   to rely on any specific relationship between application messages
   being proxied and application messages being sent to a callout
   service.  Similarly, specific adaptation actions at the callout
   server are outside OCP Core scope.

   This specification does not define or require any specific
   relationship among application messages being proxied by an OPES
   processor and application messages being exchanged between an OPES
   processor and a callout server via OCP.  The OPES processor usually
   provides some mapping among these application messages, but the
   processor's specific actions are beyond OCP scope.  In other words,
   this specification is not concerned with the OPES processor role as



Rousskov                    Standards Track                     [Page 4]

RFC 4037               OPES Callout Protocol Core             March 2005


   an application proxy or as an iterator of callout services.  The
   scope of OCP Core is communication between a single OPES processor
   and a single callout server.

   Furthermore, an OPES processor may choose which proxied application
   messages or information about them to send over OCP.  All proxied
   messages on all proxied connections (if connections are defined for a
   given application protocol), everything on some connections, selected
   proxied messages, or nothing might be sent over OCP to callout
   servers.  OPES processor and callout server state related to proxied
   protocols can be relayed over OCP as application message metadata.

1.2.  OPES Document Map

   This document belongs to a large set of OPES specifications produced
   by the IETF OPES Working Group.  Familiarity with the overall OPES
   approach and typical scenarios is often essential when one tries to
   comprehend isolated OPES documents.  This section provides an index
   of OPES documents to assist the reader with finding "missing"
   information.

   o  "OPES Use Cases and Deployment Scenarios" [RFC3752] describes a
      set of services and applications that are considered in scope for
      OPES and that have been used as a motivation and guidance in
      designing the OPES architecture.

   o  The OPES architecture and common terminology are described in "An
      Architecture for Open Pluggable Edge Services (OPES)" [RFC3835].

   o  "Policy, Authorization, and Enforcement Requirements of OPES"
      [RFC3838] outlines requirements and assumptions on the policy
      framework, without specifying concrete authorization and
      enforcement methods.

   o  "Security Threats and Risks for OPES" [RFC3837] provides OPES risk
      analysis, without recommending specific solutions.

   o  "OPES Treatment of IAB Considerations" [RFC3914] addresses all
      architecture-level considerations expressed by the IETF Internet
      Architecture Board (IAB) when the OPES WG was chartered.

   o  At the core of the OPES architecture are the OPES processor and
      the callout server, two network elements that communicate with
      each other via an OPES Callout Protocol (OCP).  The requirements
      for this protocol are discussed in "Requirements for OPES Callout
      Protocols" [RFC3836].





Rousskov                    Standards Track                     [Page 5]

RFC 4037               OPES Callout Protocol Core             March 2005


   o  This document specifies an application agnostic protocol core to
      be used for the communication between an OPES processor and a
      callout server.

   o  "OPES Entities and End Points Communications" [RFC3897] specifies
      generic tracing and bypass mechanisms for OPES.

   o  The OCP Core and communications documents are independent from the
      application protocol being adapted by OPES entities.  Their
      generic mechanisms have to be complemented by application-specific
      profiles.  "HTTP Adaptation with OPES" [OPES-HTTP] is such an
      application profile for HTTP.  It specifies how
      application-agnostic OPES mechanisms are to be used and augmented
      in order to support adaptation of HTTP messages.

   o  Finally, "P: Message Processing Language" [OPES-RULES] defines a
      language for specifying what OPES adaptations (e.g., translation)
      must be applied to what application messages (e.g., e-mail from
      bob@example.com).  P language is intended for configuring
      application proxies (OPES processors).

1.3.  Terminology

   In this document, the keywords "MUST", "MUST NOT", "REQUIRED",
   "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY",
   and "OPTIONAL" in this document are to be interpreted as described in
   [RFC2119].  When used with the normative meanings, these keywords
   will be all uppercase.  Occurrences of these words in lowercase
   constitute normal prose usage, with no normative implications.

   The OPES processor works with messages from application protocols and
   may relay information about those application messages to a callout
   server.  OCP is also an application protocol.  Thus, protocol
   elements such as "message", "connection", or "transaction" exist in
   OCP and other application protocols.  In this specification, all
   references to elements from application protocols other than OCP are
   used with an explicit "application" qualifier.  References without
   the "application" qualifier refer to OCP elements.

   OCP message: A basic unit of communication between an OPES processor
      and a callout server.  The message is a sequence of octets
      formatted according to syntax rules (section 3.1).  Message
      semantics is defined in section 11.

   application message: An entity defined by OPES processor and callout
      server negotiation.  Usually, the negotiated definition would
      match the definition from an application protocol (e.g., [RFC2616]
      definition of an HTTP message).



Rousskov                    Standards Track                     [Page 6]

RFC 4037               OPES Callout Protocol Core             March 2005


   application message data: An opaque sequence of octets representing a
      complete or partial application message.  OCP Core does not
      distinguish application message structures (if there are any).
      Application message data may be empty.

   data: Same as application message data.

   original: Referring to an application message flowing from the OPES
      processor to a callout server.

   adapted: Referring to an application message flowing from an OPES
      callout server to the OPES processor.

   adaptation: Any kind of access by a callout server, including
      modification, generation, and copying.  For example, translating
      or logging an SMTP message is adaptation of that application
      message.

   agent: The actor for a given communication protocol.  The OPES
      processor and callout server are OCP agents.  An agent can be
      referred to as a sender or receiver, depending on its actions in a
      particular context.

   immediate: Performing the specified action before reacting to new
      incoming messages or sending any new messages unrelated to the
      specified action.

   OCP extension: A specification extending or adjusting this document
      for adaptation of an application protocol (a.k.a., application
      profile; e.g., [OPES-HTTP]), new OCP functionality (e.g.,
      transport encryption and authentication), and/or new OCP Core
      version.

2.  Overall Operation

   The OPES processor may use the OPES callout protocol (OCP) to
   communicate with callout servers.  Adaptation using callout services
   is sometimes called "bump in the wire" architecture.

2.1.  Initialization

   The OPES processor establishes transport connections with callout
   servers to exchange application messages with the callout server(s)
   by using OCP.  After a transport-layer connection (usually TCP/IP) is
   established, communicating OCP agents exchange Connection Start (CS)
   messages.  Next, OCP features can be negotiated between the processor
   and the callout server (see section 6).  For example, OCP agents may
   negotiate transport encryption and application message definition.



Rousskov                    Standards Track                     [Page 7]

RFC 4037               OPES Callout Protocol Core             March 2005


   When enough settings are negotiated, OCP agents may start exchanging
   application messages.

   OCP Core provides negotiation and other mechanisms for agents to
   encrypt OCP connections and authenticate each other.  OCP Core does
   not require OCP connection encryption or agent authentication.
   Application profiles and other OCP extensions may document and/or
   require these and other security mechanisms.  OCP is expected to be
   used, in part, in closed environments where trust and privacy are
   established by means external to OCP.  Implementations are expected
   to demand necessary security features via the OCP Core negotiation
   mechanism, depending on agent configuration and environment.

2.2.  Original Dataflow

   When the OPES processor wants to adapt an application message, it
   sends a Transaction Start (TS) message to initiate an OCP transaction
   dedicated to that application message.  The processor then sends an
   Application Message Start (AMS) message to prepare the callout server
   for application data that will follow.  Once the application message
   scope is established, application data can be sent to the callout
   server by using Data Use Mine (DUM) and related OCP message(s).  All
   of these messages correspond to the original dataflow.

2.3.  Adapted Dataflow

   The callout server receives data and metadata sent by the OPES
   processor (original dataflow).  The callout server analyses metadata
   and adapts data as it comes in.  The server usually builds its
   version of metadata and responds to the OPES processor with an
   Application Message Start (AMS) message.  Adapted application message
   data can be sent next, using Data Use Mine (DUM) OCP message(s).  The
   application message is then announced to be "completed" or "closed"
   by using an Application Message End (AME) message.  The transaction
   may be closed by using a Transaction End (TE) message, as well.  All
   these messages correspond to adapted data flow.

       +---------------+                             +-------+
       |     OPES      | == (original data flow) ==> |callout|
       |   processor   | <== (adapted data flow) === |server |
       +---------------+                             +-------+

   The OPES processor receives the adapted application message sent by
   the callout server.  Other OPES processor actions specific to the
   application message received are outside scope of this specification.






Rousskov                    Standards Track                     [Page 8]

RFC 4037               OPES Callout Protocol Core             March 2005


2.4.  Multiple Application Messages

   OCP Core specifies a transactions interface dedicated to exchanging a
   single original application message and a single adapted application
   message.  Some application protocols may require multiple adapted
   versions for a single original application message or even multiple
   original messages to be exchanged as a part of a single OCP
   transaction.  For example, a single original e-mail message may need
   to be transformed into several e-mail messages, with one custom
   message for each recipient.

   OCP extensions MAY document mechanisms for exchanging multiple
   original and/or multiple adapted application messages within a single
   OCP transaction.

2.5.  Termination

   Either OCP agent can terminate application message delivery,
   transaction, or connection by sending an appropriate OCP message.
   Usually, the callout server terminates adapted application message
   delivery and the transaction.  Premature and abnormal terminations at
   arbitrary times are supported.  The termination message includes a
   result description.

2.6.  Message Exchange Patterns

   In addition to messages carrying application data, OCP agents may
   also exchange messages related to their configuration, state,
   transport connections, application connections, etc.  A callout
   server may remove itself from the application message processing
   loop.  A single OPES processor can communicate with many callout
   servers and vice versa.  Though many OCP exchange patterns do not
   follow a classic client-server model, it is possible to think of an
   OPES processor as an "OCP client" and of a callout server as an "OCP
   server".  The OPES architecture document [RFC3835] describes
   configuration possibilities.

   The following informal rules illustrate relationships between
   connections, transactions, OCP messages, and application messages:

   o  An OCP agent may communicate with multiple OCP agents.  This is
      outside the scope of this specification.

   o  An OPES processor may have multiple concurrent OCP connections to
      a callout server.  Communication over multiple OCP connections is
      outside the scope of this specification.





Rousskov                    Standards Track                     [Page 9]

RFC 4037               OPES Callout Protocol Core             March 2005


   o  A connection may carry multiple concurrent transactions.  A
      transaction is always associated with a single connection (i.e., a
      transaction cannot span multiple concurrent connections).

   o  A connection may carry at most one message at a time, including
      control messages and transaction-related messages.  A message is
      always associated with a single connection (i.e., a message cannot
      span multiple concurrent connections).

   o  A transaction is a sequence of messages related to application of
      a given set of callout services to a single application message.

      A sequence of transaction messages from an OPES processor to a
      callout server is called original flow.  A sequence of transaction
      messages from a callout server to an OPES processor is called
      adapted flow.  The two flows may overlap in time.

   o  In OCP Core, a transaction is associated with a single original
      and a single adapted application message.  OCP Core extensions may
      extend transaction scope to more application messages.

   o  An application message (adapted or original) is transferred by
      using a sequence of OCP messages.

2.7.  Timeouts

   OCP violations, resource limits, external dependencies, and other
   factors may lead to states in which an OCP agent is not receiving
   required messages from the other OCP agent.  OCP Core defines no
   messages to address such situations.  In the absence of any extension
   mechanism, OCP agents must implement timeouts for OCP operations.  An
   OCP agent MUST forcefully terminate any OCP connection, negotiation,
   transaction, etc.  that is not making progress.  This rule covers
   both dead- and livelock situations.

   In their implementation, OCP agents MAY rely on transport-level or
   other external timeouts if such external timeouts are guaranteed to
   happen for a given OCP operation.  Depending on the OCP operation, an
   agent may benefit from "pinging" the other side with a Progress Query
   (PQ) message before terminating an OCP transaction or connection.
   The latter is especially useful for adaptations that may take a long
   time at the callout server before producing any adapted data.









Rousskov                    Standards Track                    [Page 10]

RFC 4037               OPES Callout Protocol Core             March 2005


2.8.  Environment

   OCP communication is assumed usually to take place over TCP/IP
   connections on the Internet (though no default TCP port is assigned
   to OCP in this specification).  This does not preclude OCP from being
   implemented on top of other transport protocols, or on other
   networks.  High-level transport protocols such as BEEP [RFC3080] may
   be used.  OCP Core requires a reliable and message-order-preserving
   transport.  Any protocol with these properties can be used; the
   mapping of OCP message structures onto the transport data units of
   the protocol in question is outside the scope of this specification.

   OCP Core is application agnostic.  OCP messages can carry
   application-specific information as a payload or as
   application-specific message parameters.

   OCP Core overhead in terms of extra traffic on the wire is about 100
   - 200 octets per small application message.  Pipelining, preview,
   data preservation, and early termination optimizations, as well as
   as-is encapsulation of application data, make fast exchange of
   application messages possible.

3.  Messages

   As defined in section 1.3, an OCP message is a basic unit of
   communication between an OPES processor and a callout server.  A
   message is a sequence of octets formatted according to syntax rules
   (section 3.1).  Message semantics is defined in section 11.  Messages
   are transmitted on top of OCP transport.

   OCP messages deal with transport, transaction management, and
   application data exchange between a single OPES processor and a
   single callout server.  Some messages can be emitted only by an OPES
   processor; some only by a callout server; and some by both OPES
   processor and callout server.  Some messages require responses (one
   could call such messages "requests"); some can only be used in
   response to other messages ("responses"); some may be sent without
   solicitation; and some may not require a response.













Rousskov                    Standards Track                    [Page 11]

RFC 4037               OPES Callout Protocol Core             March 2005


3.1.  Message Format

   An OCP message consists of a message name followed by optional
   parameters and a payload.  The exact message syntax is defined by the
   following Augmented Backus-Naur Form (ABNF) [RFC2234]:

   message = name [SP anonym-parameters]
             [CRLF named-parameters CRLF]
             [CRLF payload CRLF]
             ";" CRLF

   anonym-parameters = value *(SP value)               ; space-separated
   named-parameters  = named-value *(CRLF named-value) ; CRLF-separated
   list-items        = value *("," value)              ; comma-separated

   payload = data

   named-value = name ":" SP value

   value     = structure / list / atom
   structure = "{" [anonym-parameters] [CRLF named-parameters CRLF] "}"
   list      = "(" [ list-items ] ")"
   atom      = bare-value / quoted-value

   name = ALPHA *safe-OCTET
   bare-value = 1*safe-OCTET
   quoted-value = DQUOTE data DQUOTE
   data = size ":" *OCTET                   ; exactly size octets

   safe-OCTET = ALPHA / DIGIT / "-" / "_"
   size = dec-number                        ; 0-2147483647
   dec-number = 1*DIGIT                     ; no leading zeros or signs

   Several normative rules accompany the above ABNF:

   o  There is no "implied linear space" (LWS) rule.  LWS rules are
      common to MIME-based grammars but are not used here.  The
      whitespace syntax is restricted to what is explicitly allowed by
      the above ABNF.

   o  All protocol elements are case sensitive unless it is specified
      otherwise.  In particular, message names and parameter names are
      case sensitive.

   o  Sizes are interpreted as decimal values and cannot have leading
      zeros.

   o  Sizes do not exceed 2147483647.



Rousskov                    Standards Track                    [Page 12]

RFC 4037               OPES Callout Protocol Core             March 2005


   o  The size attribute in a quoted-value encoding specifies the exact
      number of octets following the column (':') separator.  If size
      octets are not followed by a quote ('"') character, the encoding
      is syntactically invalid.

   o  Empty quoted values are encoded as a 4-octet sequence "0:".

   o  Any bare value can be encoded as a quoted value.  A quoted value
      is interpreted after the encoding is removed.  For example, number
      1234 can be encoded as four octets 1234 or as eight octets
      "4:1234", yielding exactly the same meaning.

   o  Unicode UTF-8 is the default encoding.  Note that ASCII is a UTF-8
      subset, and that the syntax prohibits non-ASCII characters outside
      of the "data" element.

   Messages violating formatting rules are, by definition, invalid.  See
   section 5 for rules governing processing of invalid messages.

3.2.  Message Rendering

   OCP message samples in this specification and its extensions may not
   be typeset to depict minor syntactical details of OCP message format.
   Specifically, SP and CRLF characters are not shown explicitly.  No
   rendering of an OCP message can be used to infer message format.  The
   message format definition above is the only normative source for all
   implementations.

   On occasion, an OCP message line exceeds text width allowed by this
   specification format.  A backslash ("\"), a "soft line break"
   character, is used to emphasize a protocol-violating
   presentation-only linebreak.  Bare backslashes are prohibited by OCP
   syntax.  Similarly, an "\r\n" string is sometimes used to emphasize
   the presence of a CRLF sequence, usually before OCP message payload.
   Normally, the visible end of line corresponds to the CRLF sequence on
   the wire.

   The next section (section 3.3) contains specific OCP message
   examples, some of which illustrate the above rendering techniques.












Rousskov                    Standards Track                    [Page 13]

RFC 4037               OPES Callout Protocol Core             March 2005


3.3.  Message Examples

   OCP syntax provides for compact representation of short control
   messages and required parameters while allowing for parameter
   extensions.  Below are examples of short control messages.  The
   required CRLF sequence at the end of each line is not shown
   explicitly (see section 3.2).

   PQ;
   TS 1 2;
   DWM 22;
   DWP 22 16;
   x-doit "5:xyzzy";

   The above examples contain atomic anonymous parameter values, such as
   number and string constants.  OCP messages sometimes use more
   complicated parameters such as item lists or structures with named
   values.  As both messages below illustrate, structures and lists can
   be nested:

   NO ({"32:http://www.iana.org/assignments/opes/ocp/tls"});
   NO ({"54:http://www.iana.org/assignments/opes/ocp/http/response"
   Optional-Parts: (request-header)
   },{"54:http://www.iana.org/assignments/opes/ocp/http/response"
   Optional-Parts: (request-header,request-body)
   Transfer-Encodings: (chunked)
   });

   Optional parameters and extensions are possible with a named
   parameters approach, as illustrated by the following example.  The
   DWM (section 11.17) message in the example has two anonymous
   parameters (the last one being an extension) and two named parameters
   (the last one being an extension).

   DWM 1 3
   Size-Request: 16384
   X-Need-Info: "26:twenty six octet extension";

   Finally, any message may have a payload part.  For example, the Data
   Use Mine (DUM) message below carries 8865 octets of raw data.

   DUM 1 13
   Modp: 75
   \r\n
   8865:... 8865 octets of raw data ...;






Rousskov                    Standards Track                    [Page 14]

RFC 4037               OPES Callout Protocol Core             March 2005


3.4.  Message Names

   Most OCP messages defined in this specification have short names,
   formed by abbreviating or compressing a longer but human-friendlier
   message title.  Short names without a central registration system
   (such as this specification or the IANA registry) are likely to cause
   conflicts.  Informal protocol extensions should avoid short names.
   To emphasize what is already defined by message syntax,
   implementations cannot assume that all message names are very short.

4.  Transactions

   An OCP transaction is a logical sequence of OCP messages processing a
   single original application message.  The result of the processing

   may be zero or more application messages, adapted from the original.
   A typical transaction consists of two message flows: a flow from the
   OPES processor to the callout server (sending the original
   application message), and a flow from the callout server to the OPES
   processor (sending adapted application messages).  The number of
   application messages produced by the callout server and whether the
   callout server actually modifies the original application message may
   depend on the requested callout service and other factors.  The OPES
   processor or the callout server can terminate the transaction by
   sending a corresponding message to the other side.

   An OCP transaction starts with a Transaction Start (TS) message sent
   by the OPES processor.  A transaction ends with the first Transaction
   End (TE) message sent or received, explicit or implied.  A TE message
   can be sent by either side.  Zero or more OCP messages associated
   with the transaction can be exchanged in between.  The figure below
   illustrates a possible message sequence (prefix "P" stands for the
   OPES processor; prefix "S" stands for the callout server).  Some
   message details are omitted.

   P: TS 10;
   P: AMS 10 1;
      ... processor sending application data to the callout server
   S: AMS 10 2;
      ... callout server sending application data to the processor
      ... processor sending application data to the callout server
   P: AME 10 1 result;
   S: AME 10 2 result;
   P: TE 10 result;







Rousskov                    Standards Track                    [Page 15]

RFC 4037               OPES Callout Protocol Core             March 2005


5.  Invalid Input

   This specification contains many criteria for valid OCP messages and
   their parts, including syntax rules, semantics requirements, and
   relationship to agents state.  In this context, "Invalid input" means
   messages or message parts that violate at least one of the normative
   rules.  A message with an invalid part is, by definition, invalid.
   If OCP agent resources are exhausted while parsing or interpreting a
   message, the agent MUST treat the corresponding OCP message as
   invalid.

   Unless explicitly allowed to do otherwise, an OCP agent MUST
   terminate the transaction if it receives an invalid message with
   transaction scope and MUST terminate the connection if it receives an
   invalid message with a connection scope.  A terminating agent MUST
   use the result status code of 400 and MAY specify termination cause
   information in the result status reason parameter (see section
   10.10).  If an OCP agent is unable to determine the scope of an
   invalid message it received, the agent MUST treat the message as
   having connection scope.

   OCP usually deals with optional but invasive application message
   manipulations for which correctness ought to be valued above
   robustness.  For example, a failure to insert or remove certain
   optional web page content is usually far less disturbing than
   corrupting (making unusable) the host page while performing that
   insertion or removal.  Most OPES adaptations are high level in
   nature, which makes it impossible to assess correctness of the
   adaptations automatically, especially if "robustness guesses" are
   involved.

6.  Negotiation

   The negotiation mechanism allows OCP agents to agree on the mutually
   acceptable set of features, including optional and
   application-specific behavior and OCP extensions.  For example,
   transport encryption, data format, and support for a new message can
   be negotiated.  Negotiation implies intent for a behavioral change.
   For a related mechanism allowing an agent to query capabilities of
   its counterpart without changing the counterpart's behavior, see the
   Ability Query (AQ) and Ability Answer (AA) message definitions.

   Most negotiations require at least one round trip time delay.  In
   rare cases when the other side's response is not required
   immediately, negotiation delay can be eliminated, with an inherent
   risk of an overly optimistic assumption about the negotiation
   response.




Rousskov                    Standards Track                    [Page 16]

RFC 4037               OPES Callout Protocol Core             March 2005


   A detected violation of negotiation rules leads to OCP connection
   termination.  This design reduces the number of negotiation scenarios
   resulting in a deadlock when one of the agents is not compliant.

   Two core negotiation primitives are supported: negotiation offer and
   negotiation response.  A Negotiation Offer (NO) message allows an
   agent to specify a set of features from which the responder has to
   select at most one feature that it prefers.  The selection is sent by
   using a Negotiation Response (NR) message.  If the response is
   positive, both sides assume that the selected feature is in effect
   immediately (see section 11.19 for details).  If the response is
   negative, no behavioral changes are assumed.  In either case, further
   offers may follow.

   Negotiating OCP agents have to take into account prior negotiated
   (i.e., already enabled) features.  OCP agents MUST NOT make and MUST
   reject offers that would lead to a conflict with already negotiated
   features.  For example, an agent cannot offer an HTTP application
   profile for a connection that already has an SMTP application profile
   enabled, as there would be no way to resolve the conflict for a given
   transaction.  Similarly, once TLSv1 connection encryption is
   negotiated, an agent must not offer and must reject offers for SSLv2
   connection encryption (unless a negotiated feature explicitly allows
   for changing an encryption scheme on the fly).

   Negotiation Offer (NO) messages may be sent by either agent.  OCP
   extensions documenting negotiation MAY assign the initiator role to
   one of the agents, depending on the feature being negotiated.  For
   example, negotiation of transport security feature should be
   initiated by OPES processors to avoid situations where both agents
   wait for the other to make an offer.

   As either agent may make an offer, two "concurrent" offers may be
   made at the same time, by the two communicating agents.  Unmanaged
   concurrent offers may lead to a negotiation deadlock.  By giving OPES
   processor a priority, offer-handling rules (section 11.18) ensure
   that only one offer per OCP connection is honored at a time, and that
   the other concurrent offers are ignored by both agents.

6.1.  Negotiation Phase

   A Negotiation Phase is a mechanism ensuring that both agents have a
   chance to negotiate all features they require before proceeding
   further.  Negotiation Phases have OCP connection scope and do not
   overlap.  For each OCP agent, the Negotiation Phase starts with the
   first Negotiation Offer (NO) message received or the first
   Negotiation Response (NR) message sent, provided the message is not a
   part of an existing Phase.  For each OCP agent, Negotiation Phase



Rousskov                    Standards Track                    [Page 17]

RFC 4037               OPES Callout Protocol Core             March 2005


   ends with the first Negotiation Response (NR) message (sent or
   received), after which the agent expects no more negotiations.  Agent
   expectation rules are defined later in this section.

   During a Negotiation Phase, an OCP agent MUST NOT send messages other
   than the following "Negotiation Phase messages": Negotiation Offer
   (NO), Negotiation Response (NR), Ability Query (AQ), Ability Answer
   (AA), Progress Query (PQ), Progress Answer (PA), Progress Report
   (PR), and Connection End (CE).

   Multiple Negotiation Phases may happen during the lifespan of a
   single OCP connection.  An agent may attempt to start a new
   Negotiation Phase immediately after the old Phase is over, but it is
   possible that the other agent will send messages other than
   "Negotiation Phase messages" before receiving the new Negotiation
   Offer (NO).  The agent that starts a Phase has to be prepared to
   handle those messages while its offer is reaching the recipient.

   An OPES processor MUST make a negotiation offer immediately after
   sending a Connection Start (CS) message.  If the OPES processor has
   nothing to negotiate, the processor MUST send a Negotiation Offer
   (NO) message with an empty features list.  These two rules bootstrap
   the first Negotiation Phase.  Agents are expected to negotiate at
   least the application profile for OCP Core.  Thus, these
   bootstrapping requirements are unlikely to result in any extra work.

   Once a Negotiation Phase starts, an agent MUST expect further
   negotiations if and only if the last NO sent or the last NR received
   contained a true "Offer-Pending" parameter value.  Informally, an
   agent can keep the phase open by sending true "Offer-Pending"
   parameters with negotiation offers or responses.  Moreover, if there
   is a possibility that the agent may need to continue the Negotiation
   Phase, the agent must send a true "Offer-Pending" parameter.

6.2.  Negotiation Examples

   Below is an example of the simplest negotiation possible.  The OPES
   processor is offering nothing and is predictably receiving a
   rejection.  Note that the NR message terminates the Negotiation Phase
   in this case because neither of the messages contains a true
   "Offer-Pending" value:

   P: NO ();
   S: NR;

   The next example illustrates how a callout server can force
   negotiation of a feature that an OPES processor has not negotiated.
   Note that the server sets the "Offer-Pending" parameter to true when



Rousskov                    Standards Track                    [Page 18]

RFC 4037               OPES Callout Protocol Core             March 2005


   responding to the processor Negotiation Offer (NO) message.  The
   processor chooses to accept the feature:

   P: NO ();
   S: NR
      Offer-Pending: true
      ;
   S: NO ({"22:ocp://feature/example/"})
      Offer-Pending: false
      ;
   P: NR {"22:ocp://feature/example/"};

   If the server seeks to stop the above negotiations after sending a
   true "Offer-Pending" value, its only option would be send an empty
   negotiation offer (see the first example above).  If the server does
   nothing instead, the OPES processor would wait for the server and
   would eventually time out the connection.

   The following example shows a dialog with a callout server that
   insists on enabling two imaginary features: strong transport
   encryption and volatile storage for responses.  The server is
   designed not to exchange sensitive messages until both features are
   enabled.  Naturally, the volatile storage feature has to be
   negotiated securely.  The OPES processor supports one of the strong
   encryption mechanisms but prefers not to offer (to volunteer support
   for) strong encryption, perhaps for performance reasons.  The server
   has to send a true "Offer-Pending" parameter to get a chance to offer
   strong encryption (which is successfully negotiated in this case).
   Any messages sent by either agent after the (only) successful NR
   response are encrypted with "strongB" encryption scheme.  The OPES
   processor does not understand the volatile storage feature, and the
   last negotiation fails (over a strongly encrypted transport
   connection).

   P: NO ({"29:ocp://example/encryption/weak"})
      ;
   S: NR
      Offer-Pending: true
      ;
   S: NO ({"32:ocp://example/encryption/strongA"},\
      {"32:ocp://example/encryption/strongB"})
      Offer-Pending: true
      ;
   P: NR {"32:ocp://example/encryption/strongB"}
      ;
   ... all traffic below is encrypted using strongB ...





Rousskov                    Standards Track                    [Page 19]

RFC 4037               OPES Callout Protocol Core             March 2005


   S: NO ({"31:ocp://example/storage/volatile"})
      Offer-Pending: false
      ;
   P: NR
      Unknowns: ({"31:ocp://example/storage/volatile"})
      ;
   S: CSE { 400 "33:lack of VolStore protocol support" }
      ;

   The following example from [OPES-HTTP] illustrates successful HTTP
   application profile negotiation:

   P: NO ({"54:http://www.iana.org/assignments/opes/ocp/http/response"
      Aux-Parts: (request-header,request-body)
      })
      SG: 5;
   S: NR {"54:http://www.iana.org/assignments/opes/ocp/http/response"
      Aux-Parts: (request-header)
      Pause-At-Body: 30
      Wont-Send-Body: 2147483647
      Content-Encodings: (gzip)
      }
      SG: 5;

7.  'Data Preservation' Optimization

   Many adaptations do not require any data modifications (e.g., message
   logging or blocking).  Some adaptations modify only a small portion
   of application message content (e.g., HTTP cookies filtering or ad
   insertion).  Yet, in many cases, the callout service has to see
   complete data.  By default, unmodified data would first travel from
   the OPES processor to the callout server and then back.  The "data
   preservation" optimization in OCP helps eliminate the return trip if
   both OCP agents cooperate.  Such cooperation is optional: OCP agents
   MAY support data preservation optimization.

   To avoid sending back unmodified data, a callout service has to know
   that the OPES processor has a copy of the data.  As data sizes can be
   very large and the callout service may not know in advance whether it
   will be able to use the processor copy, it is not possible to require
   the processor to keep a copy of the entire original data.  Instead,
   it is expected that a processor may keep some portion of the data,
   depending on processor settings and state.

   When an OPES processor commits to keeping a data chunk, it announces
   its decision and the chunk parameters via a Kept parameter of a Data
   Use Mine (DUM) message.  The callout server MAY "use" the chunk by
   sending a Data Use Yours (DUY) message referring to the preserved



Rousskov                    Standards Track                    [Page 20]

RFC 4037               OPES Callout Protocol Core             March 2005


   chunk.  That OCP message does not have payload and, therefore, the
   return trip is eliminated.

   As the mapping between original and adapted data is not known to the
   processor, the processor MUST keep the announced-as-preserved chunk
   until the end of the corresponding transaction, unless the callout
   server explicitly tells the processor that the chunk is not needed.
   As implied by the above requirement, the processor cannot assume that
   a data chunk is no longer needed just because the callout server sent
   a Data Use Yours (DUY) message or adapted data with, for instance,
   the same offset as the preserved chunk.

   For simplicity, preserved data is always a contiguous chunk of
   original data, described by an (offset, size) pair using a "Kept"
   parameter of a Data Use Mine (DUM) message.  An OPES processor may
   volunteer to increase the size of the kept data.  An OPES processor
   may increase the offset if the callout server indicated that the kept
   data is no longer needed.

   Both agents may benefit from data reuse.  An OPES processor has to
   allocate storage to support this optimization, but a callout server
   does not.  On the other hand, it is the callout server that is
   responsible for relieving the processor from data preservation
   commitments.  There is no simple way to resolve this conflict of
   interest on a protocol level.  Some OPES processors may allocate a
   relatively small buffer for data preservation purposes and stop
   preserving data when the buffer becomes full.  This technique would
   benefit callout services that can quickly reuse or discard kept data.
   Another processor strategy would be to size the buffer based on
   historical data reuse statistics.  To improve chances of beneficial
   cooperation, callout servers are strongly encouraged to immediately
   notify OPES processors of unwanted data.  The callout server that
   made a decision not to send Data Use Yours (DUY) messages (for a
   specific data ranges or at all) SHOULD immediately inform the OPES
   processor of that decision with the corresponding Data Preservation
   Interest (DPI) message(s) or other mechanisms.

8.  'Premature Dataflow Termination' Optimizations

   Many callout services adapt small portions of large messages and
   would preferably not to be in the loop when that adaptation is over.
   Some callout services may not seek data modification and would
   preferably not send data back to the OPES processor, even if the OPES
   processor is not supporting the data preservation optimization
   (Section 7).  By OCP design, unilateral premature dataflow
   termination by a callout server would lead to termination of an OCP
   transaction with an error.  Thus, the two agents must cooperate to
   allow for error-free premature termination.



Rousskov                    Standards Track                    [Page 21]

RFC 4037               OPES Callout Protocol Core             March 2005


   This section documents two mechanisms for premature termination of
   original or adapted dataflow.  In combination, the mechanisms allow
   the callout server to get out of the processing loop altogether.

8.1.  Original Dataflow

   There are scenarios where a callout server is not interested in the
   remaining original dataflow.  For example, a simple access blocking
   or "this site is temporary down" callout service has to send an
   adapted (generated) application message but would preferably not
   receive original data from the OPES processor.

   OCP Core supports premature original dataflow termination via the
   Want Stop Receiving Data (DWSR) message.  A callout server that does
   not seek to receive additional original data (beyond a certain size)
   sends a DWSR message.  The OPES processor receiving a DWSR message
   terminates original dataflow by sending an Application Message End
   (AME) message with a 206 (partial) status code.

   The following figure illustrates a typical sequence of events.  The
   downward lines connecting the two dataflows illustrate the
   transmission delay that allows for more OCP messages to be sent while
   an agent waits for the opposing agent reaction.

   OPES                 Callout
   Processor            Server
       DUM>             <DUM
       DUM>             <DWSR  <-- Server is ready to stop receiving
       ...        _____/<DUM   <-- Server continues as usual
       DUM>______/      <DUM
       AME>             ...    <-- Processor stops sending original data
           \_____       <DUM
                 \______<DUM
                        <DUM   <-- Server continues to send adapted data
                        ...
                        <AME

   The mechanism described in this section has no effect on the adapted
   dataflow.  Receiving an Application Message End (AME) message with
   206 (partial) result status code from the OPES processor does not
   introduce any special requirements for the adapted dataflow
   termination.  However, it is not possible to terminate adapted
   dataflow prematurely after the original dataflow has been prematurely
   terminated (see section 8.3).







Rousskov                    Standards Track                    [Page 22]

RFC 4037               OPES Callout Protocol Core             March 2005


8.2.  Adapted Dataflow

   There are scenarios where a callout service may want to stop sending
   adapted data before a complete application message has been sent.
   For example, a logging-only callout service has to receive all
   application messages but would preferably not send copies back to the
   OPES processor.

   OCP Core supports premature adapted dataflow termination via a
   combination of Want Stop Sending Data (DWSS) and Stop Sending Data
   (DSS) messages.  A callout service that seeks to stop sending data
   sends a DWSS message, soliciting an OPES processor permission to
   stop.  While waiting for the permission, the server continues with
   its usual routine.

   An OPES processor receiving a Want Stop Sending Data message responds
   with a Stop Sending Data (DSS) message.  The processor may then pause
   to wait for the callout server to terminate the adapted dataflow or
   may continue sending original data while making a copy of it.  Once
   the server terminates the adapted dataflow, the processor is
   responsible for using original data (sent or paused after sending
   DSS) instead of the adapted data.

   The callout server receiving a DSS message terminates the adapted
   dataflow (see the Stop Sending Data (DSS) message definition for the
   exact requirements and corner cases).

   The following figure illustrates a typical sequence of events,
   including a possible pause in original dataflow when the OPES
   processor is waiting for the adapted dataflow to end.  The downward
   lines connecting the two dataflows illustrate the transmission delay
   that allows for more OCP messages to be sent while an agent waits for
   the opposing agent reaction.


















Rousskov                    Standards Track                    [Page 23]

RFC 4037               OPES Callout Protocol Core             March 2005


   OPES                 Callout
   Processor            Server
       DUM>             <DUM
       DUM>             <DWSS    <-- Server is ready to stop sending
       ...        _____/<DUM     <-- Server continues as usual,
       DUM>______/      <DUM         waiting for DSS
       DSS>             ...
           \_____       <DUM
     possible    \______<DUM
     org-dataflow       <AME 206 <-- Server terminates adapted dataflow
     pause        _____/             upon receiving the DSS message
           ______/
       DUM>                      <-- Processor resumes original dataflow
       DUM>                          to the server and starts using
       ...                           original data without adapting it
       AME>

   Premature adapted dataflow preservation is not trivial, as the OPES
   processor relies on the callout server to provide adapted data
   (modified or not) to construct the adapted application message.  If
   the callout server seeks to quit its job, special care must be taken
   to ensure that the OPES processor can construct the complete
   application message.  On a logical level, this mechanism is
   equivalent to switching from one callout server to another
   (non-modifying) callout server in the middle of an OCP transaction.

   Other than a possible pause in the original dataflow, the mechanism
   described in this section has no effect on the original dataflow.
   Receiving an Application Message End (AME) message with 206 (partial)
   result status code from the callout server does not introduce any
   special requirements for the original dataflow termination.

8.3.  Getting Out of the Loop

   Some adaptation services work on application message prefixes and do
   not seek to be in the adaptation loop once their work is done.  For
   example, an ad insertion service that did its job by modifying the
   first fragment of a web "page" would not seek to receive more
   original data or to perform further adaptations.  The 'Getting Out of
   the Loop' optimization allows a callout server to get completely out
   of the application message processing loop.

   The "Getting Out of the Loop" optimization is made possible by
   terminating the adapted dataflow (section 8.2) and then by
   terminating the original dataflow (section 8.1).  The order of
   termination is very important.





Rousskov                    Standards Track                    [Page 24]

RFC 4037               OPES Callout Protocol Core             March 2005


   If the original dataflow is terminated first, the OPES processor
   would not allow the adapted dataflow to be terminated prematurely, as
   the processor would not be able to reconstruct the remaining portion
   of the adapted application message.  The processor would not know
   which suffix of the remaining original data has to follow the adapted
   parts.  The mapping between original and adapted octets is known only
   to the callout service.

   An OPES processor that received a DWSS message followed by a DWSR
   message MUST NOT send an AME message with a 206 (partial) status code
   before sending a DSS message.  Informally, this rule means that a
   callout server that wants to get out of the loop fast should send a
   DWSS message immediately followed by a DWSR message; the server does
   not have to wait for the OPES processor's permission to terminate
   adapted dataflow before requesting that the OPES processor terminates
   original dataflow.

9.  Protocol Element Type Declaration Mnemonic (PETDM)

   A protocol element type is a named set of syntax and semantics rules.
   This section defines a simple, formal declaration mnemonic for
   protocol element types, labeled PETDM.  PETDM simplicity is meant to
   ease type declarations in this specification.  PETDM formality is
   meant to improve interoperability among implementations.  Two
   protocol elements are supported by PETDM: message parameter values
   and messages.

   All OCP Core parameter and message types are declared by using PETDM.
   OCP extensions SHOULD use PETDM when declaring new types.

   Atom, list, structure, and message constructs are four available base
   types.  Their syntax and semantics rules are defined in section 3.1.
   New types can be declared in PETDM to extend base types semantics by
   using the following declaration templates.  The new semantics rules
   are meant to be attached to each declaration using prose text.

   Text in angle brackets "<>" are template placeholders, to be
   substituted with actual type names or parameter name tokens.  Square
   brackets "[]" surround optional elements such as structure members or
   message payload.

   o  Declaring a new atomic type:
   <new-type-name>: extends atom;

   o  Declaring a new list with old-type-name items:
   <new-type-name>: extends list of <old-type-name>;
   Unless it is explicitly noted otherwise, empty lists are valid and
   have the semantics of an absent parameter value.



Rousskov                    Standards Track                    [Page 25]

RFC 4037               OPES Callout Protocol Core             March 2005


   o  Declaring a new structure with members:
   <new-type-name>: extends structure with {
           <old-type-nameA> <old-type-nameB> [<old-type-nameC>] ...;
           <member-name1>: <old-type-name1>;
           <member-name2>: <old-type-name2>;
           [<member-name3>: <old-type-name3>];
           ...
   };

   The new structure may have anonymous members and named members.
   Neither group has to exist.  Note that it is always possible for
   extensions to add more members to old structures without affecting
   type semantics because unrecognized members are ignored by compliant
   agents.

   o  Declaring a new message with parameters:
   <new-type-name>: extends message with {
           <old-type-nameA> <old-type-nameB> [<old-type-nameC>] ...;
           <parameter-name1>: <old-type-name1>;
           <parameter-name2>: <old-type-name2>;
           [<parameter-name3>: <old-type-name3>];
           ...
   };

   The new type name becomes the message name.  Just as when a structure
   is extended, the new message may have anonymous parameters and named
   parameters.  Neither group has to exist.  Note that it is always
   possible for extensions to add more parameters to old messages
   without affecting type semantics because unrecognized parameters are
   ignored by compliant agents.

   o  Extending a type with more semantics details:

   <new-type-name>: extends <old-type-name>;

   o  Extending a structure- or message-base type:
   <new-type-name>: extends <old-type-name> with {
           <old-type-nameA> <old-type-nameB> [<old-type-nameC>] ...;
           <member-name1>: <old-type-name1>;
           <member-name2>: <old-type-name2>;
           [<member-name3>: <old-type-name3>];
           ...
   };
   New anonymous members are appended to the anonymous members of the
   old type, and new named members are merged with named members of the
   old type.





Rousskov                    Standards Track                    [Page 26]

RFC 4037               OPES Callout Protocol Core             March 2005


   o  Extending a message-base type with payload semantics:
   <new-type-name>: extends <old-type-name> with {
           ...
   } and payload;
   Any any OCP message can have payload, but only some message types
   have known payload semantics.  Like any parameter, payload may be
   required or optional.

   o  Extending type semantics without renaming the type:
   <old-type-name>: extends <namespace>::<old-type-name>;
   The above template can be used by OCP Core extensions that seek to
   change the semantics of OCP Core types without renaming them.  This
   technique is essential for extending OCP messages because the message
   name is the same as the message type name.  For example, an SMTP
   profile for OCP might use the following declaration to extend an
   Application Message Start (AMS) message with Am-Id, a parameter
   defined in that profile:

   AMS: extends Core::AMS with {
           Am-Id: am-id;
   };

   All extended types may be used as replacements of the types they
   extend.  For example, a Negotiation Offer (NO) message uses a
   parameter of type Features.  Features (section 10.12) is a list of
   feature (section 10.11) items.  A Feature is a structure-based type.
   An OCP extension (e.g., an HTTP application profile) may extend the
   feature type and use a value of that extended type in a negotiation
   offer.  Recipients that are aware of the extension will recognize
   added members in feature items and negotiate accordingly.  Other
   recipients will ignore them.

   The OCP Core namespace tag is "Core".  OCP extensions that declare
   types MUST define their namespace tags (so that other extensions and
   documentation can use them in their PETDM declarations).

9.1.  Optional Parameters

   Anonymous parameters are positional: The parameter's position (i.e.,
   the number of anonymous parameters to the left) is its "name".  Thus,
   when a structure or message has multiple optional anonymous
   parameters, parameters to the right can be used only if all
   parameters to the left are present.  The following notation

   [name1] [name2] [name3] ... [nameN]

   is interpreted as




Rousskov                    Standards Track                    [Page 27]

RFC 4037               OPES Callout Protocol Core             March 2005


   [name1 [ name2 [ name3 ... [nameN] ... ]]]

   When an anonymous parameter is added to a structure or message that
   has optional anonymous parameters, the new parameter has to be
   optional and can only be used if all old optional parameters are in
   use.  Named parameters do not have these limitations, as they are not
   positional, but associative; they are identified by their explicit
   and unique names.

10.  Message Parameter Types

   This section defines parameter value types that are used for message
   definitions (section 11).  Before using a parameter value, an OCP
   agent MUST check whether the value has the expected type (i.e.,
   whether it complies with all rules from the type definition).  A
   single rule violation means that the parameter is invalid.  See
   Section 5 for rules on processing invalid input.

   OCP extensions MAY define their own types.  If they do, OCP
   extensions MUST define types with exactly one base format and MUST
   specify the type of every new protocol element they introduce.

10.1.  uri

   uri: extends atom;

   Uri (universal resource identifier) is an atom formatted according to
   URI rules in [RFC2396].

   Often, a uri parameter is used as a unique (within a given scope)
   identifier.  Uni semantics is incomplete without the scope
   specification.  Many uri parameters are URLs.  Unless it is noted
   otherwise, URL identifiers do not imply the existence of a
   serviceable resource at the location they specify.  For example, an
   HTTP request for an HTTP-based URI identifier may result in a 404
   (Not Found) response.

10.2.  uni

   uni: extends atom;

   Uni (unique numeric identifier) is an atom formatted as dec-number
   and with a value in the [0, 2147483647] range, inclusive.

   A uni parameter is used as a unique (within a given scope)
   identifier.  Uni semantics is incomplete without the scope
   specification.  Some OCP messages create identifiers (i.e., bring
   them into scope).  Some OCP messages destroy them (i.e, remove them



Rousskov                    Standards Track                    [Page 28]

RFC 4037               OPES Callout Protocol Core             March 2005


   from scope).  An OCP agent MUST NOT create the same uni value more
   than once within the same scope.  When creating a new identifier of
   the same type and within the same scope as some old identifier, an
   OCP agent MUST use a higher numerical value for the new identifier.
   The first rule makes uni identifiers suitable for cross-referencing
   logs and other artifacts.  The second rule makes efficient checks of
   the first rule possible.

   For example, a previously used transaction identifier "xid" must not
   be used for a new Transaction Start (TS) message within the same OCP
   transaction, even if a prior Transaction End (TE) message was sent
   for the same transaction.

   An OCP agent MUST terminate the state associated with uni uniqueness
   scope if all unique values have been used up.

10.3.  size

   size: extends atom;

   Size is an atom formatted as dec-number and with a value in the [0,
   2147483647] range, inclusive.

   Size value is the number of octets in the associated data chunk.

   OCP Core cannot handle application messages that exceed 2147483647
   octets in size, that require larger sizes as a part of OCP marshaling
   process, or that use sizes with granularity other than 8 bits.  This
   limitation can be addressed by OCP extensions, as hinted in section
   15.1.

10.4.  offset

   offset: extends atom;

   Offset is an atom formatted as dec-number and with a value in the [0,
   2147483647] range, inclusive.

   Offset is an octet position expressed in the number of octets
   relative to the first octet of the associated dataflow.  The offset
   of the first data octet has a value of zero.

10.5.  percent

   percent: extends atom;

   Percent is an atom formatted as dec-number and with a value in the
   [0, 100] range, inclusive.



Rousskov                    Standards Track                    [Page 29]

RFC 4037               OPES Callout Protocol Core             March 2005


   Percent semantics is incomplete unless its value is associated with a
   boolean statement or assertion.  The value of 0 indicates absolute
   impossibility.  The value of 100 indicates an absolute certainty.  In
   either case, the associated statement can be relied upon as if it
   were expressed in boolean rather than probabilistic terms.  Values in
   the [1,99] inclusive range indicate corresponding levels of certainty
   that the associated statement is true.

10.6.  boolean

   boolean: extends atom;

   Boolean type is an atom with two valid values: true and false.  A
   boolean parameter expresses the truthfulness of the associated
   statement.

10.7.  xid

   xid: extends uni;

   Xid, an OCP transaction identifier, uniquely identifies an OCP
   transaction within an OCP connection.

10.8.  sg-id

   sg-id: extends uni;

   Sg-id, a service group identifier, uniquely identifies a group of
   services on an OCP connection.

10.9.  modp

   modp: extends percent;

   Modp extends the percent type to express the sender's confidence that
   application data will be modified.  The boolean statement associated
   with the percentage value is "data will be modified".  Modification
   is defined as adaptation that changes the numerical value of at least
   one data octet.

10.10.  result

   result: extends structure with {
           atom [atom];
   };

   The OCP processing result is expressed as a structure with two
   documented members: a required Uni status code and an optional



Rousskov                    Standards Track                    [Page 30]

RFC 4037               OPES Callout Protocol Core             March 2005


   reason.  The reason member contains informative textual information
   not intended for automated processing.  For example:

   { 200 OK }
   { 200 "6:got it" }
   { 200 "27:27 octets in UTF-8 encoding" }

   This specification defines the following status codes:

   Result Status Codes

   +--------+--------------+-------------------------------------------+
   |   code |     text     | semantics                                 |
   +--------+--------------+-------------------------------------------+
   |    200 |      OK      | Overall success.  This specification does |
   |        |              | not contain any general actions for a 200 |
   |        |              | status code recipient.                    |
   |    206 |    partial   | Partial success.  This status code is     |
   |        |              | documented for Application Message End    |
   |        |              | (AME) messages only.  The code indicates  |
   |        |              | that the agent terminated the             |
   |        |              | corresponding dataflow prematurely (i.e., |
   |        |              | more data would be needed to reconstruct  |
   |        |              | a complete application message).          |
   |        |              | Premature termination of one dataflow     |
   |        |              | does not introduce any special            |
   |        |              | requirements for the other dataflow       |
   |        |              | termination.  See dataflow termination    |
   |        |              | optimizations (section 8) for use cases.  |
   |    400 |    failure   | An error, exception, or trouble.  A       |
   |        |              | recipient of a 400 (failure) result of an |
   |        |              | AME, TE, or CE message MUST destroy any   |
   |        |              | state or data associated with the         |
   |        |              | corresponding dataflow, transaction, or   |
   |        |              | connection.  For example, an adapted      |
   |        |              | version of the application message data   |
   |        |              | must be purged from the processor         |
   |        |              | cache if the OPES processor receives an   |
   |        |              | Application Message End (AME) message     |
   |        |              | with result code of 400.                  |
   +--------+--------------+-------------------------------------------+

   Specific OCP messages may require code-specific actions.

   Extending result semantics is made possible by adding new "result"
   structure members or by negotiating additional result codes (e.g., as
   a part of a negotiated profile).  A recipient of an unknown (in




Rousskov                    Standards Track                    [Page 31]

RFC 4037               OPES Callout Protocol Core             March 2005


   then-current context) result code MUST act as if code 400 (failure)
   were received.

   The recipient of a message without the actual result parameter, but
   with an optional formal result parameter, MUST act as if code 200
   (OK) were received.

   Textual information (the second anonymous parameter of the result
   structure) is often referred to as "reason" or "reason phrase".  To
   assist manual troubleshooting efforts, OCP agents are encouraged to
   include descriptive reasons with all results indicating a failure.

   In this specification, an OCP message with result status code of 400
   (failure) is called "a message indicating a failure".

10.11.  feature

   feature: extends structure with {
           uri;
   };

   The feature type extends structure to relay an OCP feature identifier
   and to reserve a "place" for optional feature-specific parameters
   (sometimes called feature attributes).  Feature values are used to
   declare support for and to negotiate use of OCP features.

   This specification does not define any features.

10.12.  features

   features: extends list of feature;

   Features is a list of feature values.  Unless it is noted otherwise,
   the list can be empty, and features are listed in decreasing
   preference order.

10.13.  service

   service: extends structure with {
           uri;
   };

   Service structure has one anonymous member, an OPES service
   identifier of type uri.  Services may have service-dependent
   parameters.  An OCP extension defining a service for use with OCP
   MUST define service identifier and service-dependent parameters, if
   there are any, as additional "service" structure members.  For
   example, a service value may look like this:



Rousskov                    Standards Track                    [Page 32]

RFC 4037               OPES Callout Protocol Core             March 2005


   {"41:http://www.iana.org/assignments/opes/ocp/tls" "8:blowfish"}

10.14.  services

   services: extends list of service;

   Services is a list of service values.  Unless it is noted otherwise,
   the list can be empty, and the order of the values is the requested
   or actual service application order.

10.15.  Dataflow Specializations

   Several parameter types, such as offset apply to both original and
   adapted dataflow.  It is relatively easy to misidentify a type's
   dataflow affiliation, especially when parameters with different
   affiliations are mixed together in one message declaration.  The
   following statements declare new dataflow-specific types by using
   their dataflow-agnostic versions (denoted by a <type> placeholder).

   The following new types refer to original data only:

   org-<type>: extends <type>;

   The following new types refer to adapted data only:

   adp-<type>: extends <type>;

   The following new types refer to the sender's dataflow only:

   my-<type>: extends <type>;

   The following new types refer to the recipient's dataflow only:

   your-<type>: extends <type>;

   OCP Core uses the above type-naming scheme to implement dataflow
   specialization for the following types: offset, size, and sg-id.  OCP
   extensions SHOULD use the same scheme.

11.  Message Definitions

   This section describes specific OCP messages.  Each message is given
   a unique name and usually has a set of anonymous and/or named
   parameters.  The order of anonymous parameters is specified in the
   message definitions below.  No particular order for named parameters
   is implied by this specification.  OCP extensions MUST NOT introduce
   order-dependent named parameters.  No more than one named-parameter




Rousskov                    Standards Track                    [Page 33]

RFC 4037               OPES Callout Protocol Core             March 2005


   with a given name can appear in the message; messages with multiple
   equally named parameters are semantically invalid.

   A recipient MUST be able to parse any message in valid format (see
   section 3.1), subject to the limitations of the recipient's
   resources.

   Unknown or unexpected message names, parameters, and payloads may be
   valid extensions.  For example, an "extra" named parameter may be
   used for a given message, in addition to what is documented in the
   message definition below.  A recipient MUST ignore any valid but
   unknown or unexpected name, parameter, member, or payload.

   Some message parameter values use uni identifiers to refer to various
   OCP states (see section 10.2 and Appendix B).  These identifiers are
   created, used, and destroyed by OCP agents via corresponding
   messages.  Except when creating a new identifier, an OCP agent MUST
   NOT send a uni identifier that corresponds to an inactive state
   (i.e., that was either never created or already destroyed).  Such
   identifiers invalidate the host OCP message (see section 5).  For
   example, the recipient must terminate the transaction when the xid
   parameter in a Data Use Mine (DUM) message refers to an unknown or
   already terminated OCP transaction.

11.1.  Connection Start (CS)

   CS: extends message;

   A Connection Start (CS) message indicates the start of an OCP
   connection.  An OCP agent MUST send this message before it sends any
   other message on the connection.  If the first message an OCP agent
   receives is not Connection Start (CS), the agent MUST terminate the
   connection with a Connection End (CE) message having 400 (failure)
   result status code.  An OCP agent MUST send Connection Start (CS)
   message exactly once.  An OCP agent MUST ignore repeated Connection
   Start (CS) messages.

   At any time, a callout server MAY refuse further processing on an OCP
   connection by sending a Connection End (CE) message with the status
   code 400 (failure).  Note that the above requirement to send a CS
   message first still applies.

   With TCP/IP as transport, raw TCP connections (local and remote peer
   IP addresses with port numbers) identify an OCP connection.  Other
   transports may provide OCP connection identifiers to distinguish
   logical connections that share the same transport.  For example, a
   single BEEP [RFC3080] channel may be designated as a single OCP
   connection.



Rousskov                    Standards Track                    [Page 34]

RFC 4037               OPES Callout Protocol Core             March 2005


11.2.  Connection End (CE)

   CE: extends message with {
           [result];
   };

   A Connection End (CE) Indicates the end of an OCP connection.  The
   agent initiating closing or termination of a connection MUST send
   this message immediately prior to closing or termination.  The
   recipient MUST free associated state, including transport state.

   Connection termination without a Connection End (CE) message
   indicates that the connection was prematurely closed, possibly
   without the closing-side agent's prior knowledge or intent.  When an
   OCP agent detects a prematurely closed connection, the agent MUST act
   as if a Connection End (CE) message indicating a failure was
   received.

   A Connection End (CE) message implies the end of all transactions,
   negotiations, and service groups opened or active on the connection
   being ended.

11.3.  Service Group Created (SGC)

   SGC: extends message with {
           my-sg-id services;
   };

   A Service Group Created (SGC) message informs the recipient that a
   list of adaptation services has been associated with the given
   service group identifier ("my-sg-id").  Following this message, the
   sender can refer to the group by using the identifier.  The recipient
   MUST maintain the association until a matching Service Group
   Destroyed (SGD) message is received or the corresponding OCP
   connection is closed.

   Service groups have a connection scope.  Transaction management
   messages do not affect existing service groups.

   Maintaining service group associations requires resources (e.g.,
   storage to keep the group identifier and a list of service IDs).
   Thus, there is a finite number of associations an implementation can
   maintain.  Callout servers MUST be able to maintain at least one
   association for each OCP connection they accept.  If a recipient of a
   Service Group Created (SGC) message does not create the requested
   association, it MUST immediately terminate the connection with a
   Connection End (CE) message indicating a failure.




Rousskov                    Standards Track                    [Page 35]

RFC 4037               OPES Callout Protocol Core             March 2005


11.4.  Service Group Destroyed (SGD)

   SGD: extends message with {
           my-sg-id;
   };

   A Service Group Destroyed (SGD) message instructs the recipient to
   forget about the service group associated with the specified
   identifier.  The recipient MUST destroy the identified service group
   association.

11.5.  Transaction Start (TS)

   TS: extends message with {
           xid my-sg-id;
   };

   Sent by an OPES processor, a Transaction Start (TS) message indicates
   the start of an OCP transaction.  Upon receiving this message, the
   callout server MAY refuse further transaction processing by
   responding with a corresponding Transaction End (TE) message.  A
   callout server MUST maintain the state until it receives a message
   indicating the end of the transaction or until it terminates the
   transaction itself.

   The required "my-sg-id" identifier refers to a service group created
   with an a Service Group Created (SGC) message.  The callout server
   MUST apply the list of services associated with "my-sg-id", in the
   specified order.

   This message introduces the transaction identifier (xid).

11.6.  Transaction End (TE)

   TE: extends message with {
           xid [result];
   };

   A Transaction End (TE) indicates the end of the identified OCP
   transaction.

   An OCP agent MUST send a Transaction End (TE) message immediately
   after it makes a decision to send no more messages related to the
   corresponding transaction.  Violating this requirement may cause, for







Rousskov                    Standards Track                    [Page 36]

RFC 4037               OPES Callout Protocol Core             March 2005


   example, unnecessary delays, rejection of new transactions, and even
   timeouts for agents that rely on this end-of-file condition to
   proceed.

   This message terminates the life of the transaction identifier (xid).

11.7.  Application Message Start (AMS)

   AMS: extends message with {
           xid;
           [Services: services];
   };

   An Application Message Start (AMS) message indicates the start of the
   original or adapted application message processing and dataflow.  The
   recipient MAY refuse further processing by sending an Application
   Message End (AME) message indicating a failure.

   When an AMS message is sent by the OPES processor, the callout server
   usually sends an AMS message back, announcing the creation of an
   adapted version of the original application message.  This
   announcement may be delayed.  For example, the callout server may
   wait for more information from the OPES processor.

   When an AMS message is sent by the callout server, an optional
   "Services" parameter describes OPES services that the server MAY
   apply to the original application message.  Usually, the "services"
   value matches what was asked by the OPES processor.  The callout
   server SHOULD send a "Services" parameter if its value would differ
   from the list of services requested by the OPES processor.  As the
   same service may be known under many names, the mismatch does not
   necessarily imply an error.

11.8.  Application Message End (AME)

   AME: extends message with {
           xid [result];
   };

   An Application Message End (AME) message indicates the end of the
   original or adapted application message processing and dataflow.  The
   recipient should expect no more data for the corresponding
   application message.

   An Application Message End (AME) message ends any data preservation
   commitments and any other state associated with the corresponding
   application message.




Rousskov                    Standards Track                    [Page 37]

RFC 4037               OPES Callout Protocol Core             March 2005


   An OCP agent MUST send an Application Message End (AME) message
   immediately after it makes a decision to stop processing of its
   application message.  Violating this requirement may cause, for
   example, unnecessary delays, rejection of new transactions, and even
   timeouts for agents that rely on this end-of-file condition to
   proceed.

11.9.  Data Use Mine (DUM)

   DUM: extends message with {
           xid my-offset;
           [As-is: org-offset];
           [Kept: org-offset org-size ];
           [Modp: modp];
   } and payload;

   A Data Use Mine (DUM) message carries application data.  It is the
   only OCP Core message with a documented payload.  The sender MUST NOT
   make any gaps in data supplied by Data Use Mine (DUM) and Data Use
   Yours (DUY) messages (i.e., the my-offset of the next data message
   must be equal to the my-offset plus the payload size of the previous
   data message).  Messages with gaps are invalid.  The sender MUST send
   payload and MAY use empty payload (i.e., payload with zero size).  A
   DUM message without payload is invalid.  Empty payloads are useful
   for communicating meta-information about the data (e.g., modification
   predictions or preservation commitments) without sending data.

   An OPES processor MAY send a "Kept" parameter to indicate its current
   data preservation commitment (section 7) for original data.  When an
   OPES processor sends a "Kept" parameter, the processor MUST keep a
   copy of the specified data (the preservation commitment starts or
   continues).  The Kept offset parameter specifies the offset of the
   first octet of the preserved data.  The Kept size parameter is the
   size of preserved data.  Note that data preservation rules allow
   (i.e., do not prohibit) an OPES processor to decrease offset and to
   specify a data range not yet fully delivered to the callout server.
   OCP Core does not require any relationship between DUM payload and
   the "Kept" parameter.

   If the "Kept" parameter value violates data preservation rules but
   the recipient has not sent any Data Use Yours (DUY) messages for the
   given OCP transaction yet, then the recipient MUST NOT use any
   preserved data for the given transaction (i.e., must not sent any
   Data Use Yours (DUY) messages).  If the "Kept" parameter value
   violates data preservation rules and the recipient has already sent
   Data Use Yours (DUY) messages, the DUM message is invalid, and the
   rules of section 5 apply.  These requirements help preserve data
   integrity when "Kept" optimization is used by the OPES processor.



Rousskov                    Standards Track                    [Page 38]

RFC 4037               OPES Callout Protocol Core             March 2005


   A callout server MUST send a "Modp" parameter if the server can
   provide a reliable value and has not already sent the same parameter
   value for the corresponding application message.  The definition of
   "reliable" is entirely up to the callout server.  The data
   modification prediction includes DUM payload.  That is, if the
   attached payload has been modified, the modp value cannot be 0%.

   A callout server SHOULD send an "As-is" parameter if the attached
   data is identical to a fragment at the specified offset in the
   original dataflow.  An "As-is" parameter specifying a data fragment
   that has not been sent to the callout server is invalid.  The
   recipient MUST ignore invalid "As-is" parameters.  Identical means
   that all adapted octets have the same numeric value as the
   corresponding original octets.  This parameter is meant to allow for
   partial data preservation optimizations without a preservation
   commitment.  The preserved data still crosses the connection with the
   callout server twice, but the OPES processor may be able to optimize
   its handling of the data.

   The OPES processor MUST NOT terminate its data preservation
   commitment (section 7) in reaction to receiving a Data Use Mine (DUM)
   message.

11.10.  Data Use Yours (DUY)

   DUY: extends message with {
           xid org-offset org-size;
   };

   The callout server tells the OPES processor to use the "size" bytes
   of preserved original data, starting at the specified offset, as if
   that data chunk came from the callout server in a Data Use Mine (DUM)
   message.

   The OPES processor MUST NOT terminate its data preservation
   commitment (section 7) in reaction to receiving a Data Use Yours
   (DUY) message.

11.11.  Data Preservation Interest (DPI)

   DPI: extends message with {
           xid org-offset org-size;
   };

   The Data Preservation Interest (DPI) message describes an original
   data chunk by using the first octet offset and size as parameters.
   The chunk is the only area of original data that the callout server
   may be interested in referring to in future Data Use Yours (DUY)



Rousskov                    Standards Track                    [Page 39]

RFC 4037               OPES Callout Protocol Core             March 2005


   messages.  This data chunk is referred to as "reusable data".  The
   rest of the original data is referred to as "disposable data".  Thus,
   disposable data consists of octets below the specified offset and at
   or above the (offset + size) offset.

   After sending this message, the callout server MUST NOT send Data Use
   Yours (DUY) messages referring to disposable data chunk(s).  If an
   OPES processor is not preserving some reusable data, it MAY start
   preserving that data.  If an OPES processor preserves some disposable
   data, it MAY stop preserving that data.  If an OPES processor does
   not preserve some disposable data, it MAY NOT start preserving that
   data.

   A callout server MUST NOT indicate reusable data areas that overlap
   with disposable data areas indicated in previous Data Preservation
   Interest (DPI) messages.  In other words, reusable data must not
   grow, and disposable data must not shrink.  If a callout server
   violates this rule, the Data Preservation Interest (DPI) message is
   invalid (see section 5).

   The Data Preservation Interest (DPI) message cannot force the OPES
   processor to preserve data.  In this context, the term reusable
   stands for callout server interest in reusing the data in the future,
   given the OPES processor cooperation.

   For example, an offset value of zero and the size value of 2147483647
   indicate that the server may want to reuse all the original data.
   The size value of zero indicates that the server is not going to send
   any more Data Use Yours (DUY) messages.

11.12.  Want Stop Receiving Data (DWSR)

   DWSR: extends message with {
           xid org-size;
   };

   The Want Stop Receiving Data (DWSR) message informs OPES processor
   that the callout server wants to stop receiving original data any
   time after receiving at least an org-size amount of an application
   message prefix.  That is, the server is asking the processor to
   terminate original dataflow prematurely (see section 8.1) after
   sending at least org-size octets.

   An OPES processor receiving a Want Stop Receiving Data (DWSR) message
   SHOULD terminate original dataflow by sending an Application Message
   End (AME) message with a 206 (partial) status code.





Rousskov                    Standards Track                    [Page 40]

RFC 4037               OPES Callout Protocol Core             March 2005


   An OPES processor MUST NOT terminate its data preservation commitment
   (section 7) in reaction to receiving a Want Stop Receiving Data
   (DWSR) message.  Just like with any other message, an OPES processor
   may use information supplied by Want Stop Receiving Data (DWSR) to
   decide on future preservation commitments.

11.13.  Want Stop Sending Data (DWSS)

   DWSS: extends message with {
           xid;
   };

   The Want Stop Sending Data (DWSS) message informs the OPES processor
   that the callout server wants to stop sending adapted data as soon as
   possible; the server is asking the processor for permission to
   terminate adapted dataflow prematurely (see section 8.2).  The OPES
   processor can grant this permission by using a Stop Sending Data
   (DSS) message.

   Once the DWSS message is sent, the callout server MUST NOT
   prematurely terminate adapted dataflow until the server receives a
   DSS message from the OPES processor.  If the server violates this
   rule, the OPES processor MUST act as if no DWSS message were
   received.  The latter implies that the OCP transaction is terminated
   by the processor, with an error.

   An OPES processor receiving a DWSS message SHOULD respond with a Stop
   Sending Data (DSS) message, provided the processor would not violate
   DSS message requirements by doing so.  The processor SHOULD respond
   immediately once DSS message requirements can be satisfied.

11.14.  Stop Sending Data (DSS)

   DSS: extends message with {
           xid;
   };

   The Stop Sending Data (DSS) message instructs the callout server to
   terminate adapted dataflow prematurely by sending an Application
   Message End (AME) message with a 206 (partial) status code.  A
   callout server is expected to solicit the Stop Sending Data (DSS)
   message by sending a Want Stop Sending Data (DWSS) message (see
   section 8.2).

   A callout server receiving a solicited Stop Sending Data (DSS)
   message for a yet-unterminated adapted dataflow MUST immediately
   terminate dataflow by sending an Application Message End (AME)
   message with a 206 (partial) status code.  If the callout server



Rousskov                    Standards Track                    [Page 41]

RFC 4037               OPES Callout Protocol Core             March 2005


   already terminated adapted dataflow, the callout server MUST ignore
   the Stop Sending Data (DSS) message.  A callout server receiving an
   unsolicited DSS message for a yet-unterminated adapted dataflow MUST
   either treat that message as invalid or as solicited (i.e., the
   server cannot simply ignore unsolicited DSS messages).

   The OPES processor sending a Stop Sending Data (DSS) message MUST be
   able to reconstruct the adapted application message correctly after
   the callout server terminates dataflow.  This requirement implies
   that the processor must have access to any original data sent to the
   callout after the Stop Sending Data (DSS) message, if there is any.
   Consequently, the OPES processor either has to send no data at all or
   has to keep a copy of it.

   If a callout server receives a DSS message and, in violation of the
   above rules, waits for more original data before sending an
   Application Message End (AME) response, a deadlock may occur: The
   OPES processor may wait for the Application Message End (AME) message
   to send more original data.

11.15.  Want Data Paused (DWP)

   DWP: extends message with {
           xid your-offset;
   };

   The Want Data Paused (DWP) message indicates the sender's temporary
   lack of interest in receiving data starting with the specified
   offset.  This disinterest implies nothing about sender's intent to
   send data.

   The "your-offset" parameter refers to dataflow originating at the OCP
   agent receiving the parameter.

   If, at the time the Want Data Paused (DWP) message is received, the
   recipient has already sent data at the specified offset, the message
   recipient MUST stop sending data immediately.  Otherwise, the
   recipient MUST stop sending data immediately after it sends the
   specified offset.  Once the recipient stops sending more data, it
   MUST immediately send a Paused My Data (DPM) message and MUST NOT
   send more data until it receives a Want More Data (DWM) message.

   As are most OCP Core mechanisms, data pausing is asynchronous.  The
   sender of the Want Data Paused (DWP) message MUST NOT rely on the
   data being paused exactly at the specified offset or at all.






Rousskov                    Standards Track                    [Page 42]

RFC 4037               OPES Callout Protocol Core             March 2005


11.16.  Paused My Data (DPM)

   DPM: extends message with {
           xid;
   };

   The Paused My Data (DPM) message indicates the sender's commitment to
   send no more data until the sender receives a Want More Data (DWM)
   message.

   The recipient of the Paused My Data (DPM) message MAY expect the data
   delivery being paused.  If the recipient receives data despite this
   expectation, it MAY abort the corresponding transaction with a
   Transaction End (TE) message indicating a failure.

11.17.  Want More Data (DWM)

   DWM: extends message with {
           xid;
           [Size-request: your-size];
   };

   The Want More Data (DWM) message indicates the sender's need for more
   data.

   Message parameters always refer to dataflow originating at the other
   OCP agent.  When sent by an OPES processor, your-size is adp-size;
   when sent by a callout server, your-size is org-size.

   The "Size-request" parameter refers to dataflow originating at the
   OCP agent receiving the parameter.  If a "Size-request" parameter is
   present, its value is the suggested minimum data size.  It is meant
   to allow the recipient to deliver data in fewer chunks.  The
   recipient MAY ignore the "Size-request" parameter.  An absent
   "Size-request" parameter implies "any size".

   The message also cancels the Paused My Data (DPM) message effect.  If
   the recipient was not sending any data because of its DPM message,
   the recipient MAY resume sending data.  Note, however, that the Want
   More Data (DWM) message can be sent regardless of whether the
   dataflow in question has been paused.  The "Size-request" parameter
   makes this message a useful stand-alone optimization.









Rousskov                    Standards Track                    [Page 43]

RFC 4037               OPES Callout Protocol Core             March 2005


11.18.  Negotiation Offer (NO)

   NO: extends message with {
           features;
           [SG: my-sg-id];
           [Offer-Pending: boolean];
   };

   A Negotiation Offer (NO) message solicits a selection of a single
   "best" feature out of a supplied list, using a Negotiation Response
   (NR) message.  The sender is expected to list preferred features
   first when it is possible.  The recipient MAY ignore sender
   preferences.  If the list of features is empty, the negotiation is
   bound to fail but remains valid.

   Both the OPES processor and the callout server are allowed to send
   Negotiation Offer (NO) messages.  The rules in this section ensure
   that only one offer is honored if two offers are submitted
   concurrently.  An agent MUST NOT send a Negotiation Offer (NO)
   message if it still expects a response to its previous offer on the
   same connection.

   If an OPES processor receives a Negotiation Offer (NO) message while
   its own offer is pending, the processor MUST disregard the server
   offer.  Otherwise, it MUST respond immediately.


   If a callout server receives a Negotiation Offer (NO) message when
   its own offer is pending, the server MUST disregard its own offer.
   In either case, the server MUST respond immediately.

   If an agent receives a message sequence that violates any of the
   above rules in this section, the agent MUST terminate the connection
   with a Connection End (CE) message indicating a failure.

   An optional "Offer-Pending" parameter is used for Negotiation Phase
   maintenance (section 6.1).  The option's value defaults to "false".

   An optional "SG" parameter is used to narrow the scope of
   negotiations to the specified service group.  If SG is present, the
   negotiated features are negotiated and enabled only for transactions
   that use the specified service group ID.  Connection-scoped features
   are negotiated and enabled for all service groups.  The presence of
   scope does not imply automatic conflict resolution common to
   programming languages; no conflicts are allowed.  When negotiating
   connection-scoped features, an agent MUST check for conflicts within
   each existing service group.  When negotiating group-scoped features,
   an agent MUST check for conflicts with connection-scoped features



Rousskov                    Standards Track                    [Page 44]

RFC 4037               OPES Callout Protocol Core             March 2005


   already negotiated.  For example, it must not be possible to
   negotiate a connection-scoped HTTP application profile if one service
   group already has an SMTP application profile, and vice versa.

   OCP agents SHOULD NOT send offers with service groups used by pending
   transactions.  Unless it is explicitly noted otherwise in a feature
   documentation, OCP agents MUST NOT apply any negotiations to pending
   transactions.  In other words, negotiated features take effect with
   the new OCP transaction.

   As with other protocol elements, OCP Core extensions may document
   additional negotiation restrictions.  For example, specification of a
   transport security feature may prohibit the use of the SG parameter
   in negotiation offers, to avoid situations where encryption is
   enabled for only a portion of overlapping transactions on the same
   transport connection.

11.19.  Negotiation Response (NR)

   NR: extends message with {
           [feature];
           [SG: my-sg-id];
           [Rejects: features];
           [Unknowns: features];
           [Offer-Pending: boolean];
   };

   A Negotiation Response (NR) message conveys recipient's reaction to a
   Negotiation Offer (NO) request.  An accepted offer (a.k.a., positive
   response) is indicated by the presence of an anonymous "feature"
   parameter, containing the selected feature.  If the selected feature
   does not match any of the offered features, the offering agent MUST
   consider negotiation failed and MAY terminate the connection with a
   Connection End (CE) message indicating a failure.

   A rejected offer (negative response) is indicated by omitting the
   anonymous "feature" parameter.

   The successfully negotiated feature becomes effective immediately.
   The sender of a positive response MUST consider the corresponding
   feature enabled immediately after the response is sent; the recipient
   of a positive response MUST consider the corresponding feature
   enabled immediately after the response is received.  Note that the
   scope of the negotiated feature application may be limited to a
   specified service group.  The negotiation phase state does not affect
   enabling of the feature.





Rousskov                    Standards Track                    [Page 45]

RFC 4037               OPES Callout Protocol Core             March 2005


   If negotiation offer contains an SG parameter, the responder MUST
   include that parameter in the Negotiation Response (NR) message.  The
   recipient of an NR message without the expected SG parameter MUST
   treat negotiation response as invalid.

   If the negotiation offer lacks an SG parameter, the responder MUST
   NOT include that parameter in the Negotiation Response (NR) message.
   The recipient of an NR message with an unexpected SG parameter MUST
   treat the negotiation response as invalid.

   An optional "Offer-Pending" parameter is used for Negotiation Phase
   maintenance (section 6.1).  The option's value defaults to "false".

   When accepting or rejecting an offer, the sender of the Negotiation
   Response (NR) message MAY supply additional details via Rejects and
   Unknowns parameters.  The Rejects parameter can be used to list
   features that were known to the Negotiation Offer (NO) recipient but
   could not be supported given negotiated state that existed when NO
   message was received.  The Unknowns parameter can be used to list
   features that were unknown to the NO recipient.

11.20.  Ability Query (AQ)

   AQ: extends message with {
           feature;
   };

   An Ability Query (AQ) message solicits an immediate Ability Answer
   (AA) response.  The recipient MUST respond immediately with an AA
   message.  This is a read-only, non-modifying interface.  The
   recipient MUST NOT enable or disable any features due to an AQ
   request.

   OCP extensions documenting a feature MAY extend AQ messages to supply
   additional information about the feature or the query itself.

   The primary intended purpose of the ability inquiry interface is
   debugging and troubleshooting and not automated fine-tuning of agent
   behavior and configuration.  The latter may be better achieved by the
   OCP negotiation mechanism (section 6).

11.21.  Ability Answer (AA)

   AA: extends message with {
           boolean;
   };





Rousskov                    Standards Track                    [Page 46]

RFC 4037               OPES Callout Protocol Core             March 2005


   An Ability Answer (AA) message expresses the sender's support for a
   feature requested via an Ability Query (AQ) message.  The sender MUST
   set the value of the anonymous boolean parameter to the truthfulness
   of the following statement: "At the time of this answer generation,
   the sender supports the feature in question".  The meaning of
   "support" and additional details are feature specific.  OCP
   extensions documenting a feature MUST document the definition of
   "support" in the scope of the above statement and MAY extend AA
   messages to supply additional information about the feature or the
   answer itself.

11.22.  Progress Query (PQ)

   PQ: extends message with {
           [xid];
   };

   A Progress Query (PQ) message solicits an immediate Progress Answer
   (PA) response.  The recipient MUST immediately respond to a PQ
   request, even if the transaction identifier is invalid from the
   recipient's point of view.

11.23.  Progress Answer (PA)

   PA: extends message with {
           [xid];
           [Org-Data: org-size];
   };

   A PA message carries the sender's state.  The "Org-Data" size is the
   total original data size received or sent by the agent so far for the
   identified application message (an agent can be either sending or
   receiving original data, so there is no ambiguity).  When referring
   to received data, progress information does not imply that the data
   has otherwise been processed in some way.

   The progress inquiry interface is useful for several purposes,
   including keeping idle OCP connections "alive", gauging the agent
   processing speed, verifying the agent's progress, and debugging OCP
   communications.  Verifying progress, for example, may be essential to
   implement timeouts for callout servers that do not send any adapted
   data until the entire original application message is received and
   processed.

   A recipient of a PA message MUST NOT assume that the sender is not
   working on any transaction or application message not identified in
   the PA message.  A PA message does not carry information about
   multiple transactions or application messages.



Rousskov                    Standards Track                    [Page 47]

RFC 4037               OPES Callout Protocol Core             March 2005


   If an agent is working on the transaction identified in the Progress
   Query (PQ) request, the agent MUST send the corresponding transaction
   ID (xid) when answering the PQ with a PA message.  Otherwise, the
   agent MUST NOT send the transaction ID.  If an agent is working on
   the original application message for the specified transaction, the
   agent MUST send the Org-Data parameter.  If the agent has already
   sent or received the Application Message End (AME) message for the
   original dataflow, the agent MUST NOT send the Org-data parameter.

   Informally, the PA message relays the sender's progress with the
   transaction and original dataflow identified by the Progress Query
   (PQ) message, provided the transaction identifier is still valid at
   the time of the answer.  Absent information in the answer indicates
   invalid, unknown, or closed transaction and/or original dataflow from
   the query recipient's point of view.

11.24.  Progress Report (PR)

   PR: extends message with {
           [xid];
           [Org-Data: org-size];
   };

   A Progress Report (PR) message carries the sender's state.  The
   message semantics and associated requirements are identical to those
   of a Progress Answer (PA) message except that the PR message, is sent
   unsolicited.  The sender MAY report progress at any time.  The sender
   MAY report progress unrelated to any transaction or original
   application message or related to any valid (current) transaction or
   original dataflow.

   Unsolicited progress reports are especially useful for OCP extensions
   dealing with "slow" callout services that introduce significant
   delays for the final application message recipient.  The report may
   contain progress information that will make that final recipient more
   delay tolerant.

12.  IAB Considerations

   OPES treatment of IETF Internet Architecture Board (IAB)
   considerations [RFC3238] are documented in [RFC3914].

13.  Security Considerations

   This section examines security considerations for OCP.  OPES threats
   are documented in [RFC3837]





Rousskov                    Standards Track                    [Page 48]

RFC 4037               OPES Callout Protocol Core             March 2005


   OCP relays application messages that may contain sensitive
   information.  Appropriate transport encryption can be negotiated to
   prevent information leakage or modification (see section 6), but OCP
   agents may support unencrypted transport by default.  These
   configurations will expose application messages to third-party
   recording and modification, even if OPES proxies themselves are
   secure.

   OCP implementation bugs may lead to security vulnerabilities in OCP
   agents, even if OCP traffic itself remains secure.  For example, a
   buffer overflow in a callout server caused by a malicious OPES
   processor may grant that processor access to information from other
   (100% secure) OCP connections, including connections with other OPES
   processors.

   Careless OCP implementations may rely on various OCP identifiers to
   be unique across all OCP agents.  A malicious agent can inject an OCP
   message that matches identifiers used by other agents, in an attempt
   to gain access to sensitive data.  OCP implementations must always
   check an identifier for being "local" to the corresponding connection
   before using that identifier.

   OCP is a stateful protocol.  Several OCP commands increase the amount
   of state that the recipient has to maintain.  For example, a Service
   Group Created (SGC) message instructs the recipient to maintain an
   association between a service group identifier and a list of
   services.

   Implementations that cannot correctly handle resource exhaustion
   increase security risks.  The following are known OCP-related
   resources that may be exhausted during a compliant OCP message
   exchange:

   OCP message structures: OCP message syntax does not limit the nesting
      depth of OCP message structures and does not place an upper limit
      on the length (number of OCTETs) of most syntax elements.

   concurrent connections: OCP does not place an upper limit on the
      number of concurrent connections that a callout server may be
      instructed to create via Connection Start (CS) messages.

   service groups: OCP does not place an upper limit on the number of
      service group associations that a callout server may be instructed
      to create via Service Group Created (SGC) messages.

   concurrent transactions: OCP does not place an upper limit on the
      number of concurrent transactions that a callout server may be
      instructed to maintain via Transaction Start (TS) messages.



Rousskov                    Standards Track                    [Page 49]

RFC 4037               OPES Callout Protocol Core             March 2005


   concurrent flows: OCP Core does not place an upper limit on the
      number of concurrent adapted flows that an OPES processor may be
      instructed to maintain via Application Message Start (AMS)
      messages.

14.  IANA Considerations

   The IANA maintains a list of OCP features, including application
   profiles (section 10.11).  For each feature, its uri parameter value
   is registered along with the extension parameters (if there are any).
   Registered feature syntax and semantics are documented with PETDM
   notation (section 9).

   The IESG is responsible for assigning a designated expert to review
   each standards-track registration prior to IANA assignment.  The OPES
   working group mailing list may be used to solicit commentary for both
   standards-track and non-standards-track features.

   Standards-track OCP Core extensions SHOULD use
   http://www.iana.org/assignments/opes/ocp/ prefix for feature uri
   parameters.  It is suggested that the IANA populate resources
   identified by such "uri" parameters with corresponding feature
   registrations.  It is also suggested that the IANA maintain an index
   of all registered OCP features at the
   http://www.iana.org/assignments/opes/ocp/ URL or on a page linked
   from that URL.

   This specification defines no OCP features for IANA registration.

15.  Compliance

   This specification defines compliance for the following compliance
   subjects:  OPES processors (OCP client implementations), callout
   servers (OCP server implementations), and OCP extensions.  An OCP
   agent (a processor or callout server) may also be referred to as the
   "sender" or "recipient" of an OCP message.

   A compliance subject is compliant if it satisfies all applicable
   "MUST" and "SHOULD" requirements.  By definition, to satisfy a "MUST"
   requirement means to act as prescribed by the requirement; to satisfy
   a "SHOULD" requirement means either to act as prescribed by the
   requirement or to have a reason to act differently.  A requirement is
   applicable to the subject if it instructs (addresses) the subject.

   Informally, OCP compliance means that there are no known "MUST"
   violations, and that all "SHOULD" violations are deliberate.  In
   other words, "SHOULD" means "MUST satisfy or MUST have a reason to
   violate".  It is expected that compliance claims be accompanied by a



Rousskov                    Standards Track                    [Page 50]

RFC 4037               OPES Callout Protocol Core             March 2005


   list of unsupported SHOULDs (if any), in an appropriate format,
   explaining why the preferred behavior was not chosen.

   Only normative parts of this specification affect compliance.
   Normative parts are those parts explicitly marked with the word
   "normative", definitions, and phrases containing unquoted capitalized
   keywords from [RFC2119].  Consequently, examples and illustrations
   are not normative.

15.1.  Extending OCP Core

   OCP extensions MUST NOT change the OCP Core message format, as
   defined by ABNF and accompanying normative rules in Section 3.1.
   This requirement is intended to allow OCP message viewers,
   validators, and "intermediary" software to at least isolate and
   decompose any OCP message, even a message with semantics unknown to
   them (i.e., extended).

   OCP extensions are allowed to change normative OCP Core requirements
   for OPES processors and callout servers.  However, OCP extensions
   SHOULD NOT make these changes and MUST require on a "MUST"-level that
   these changes are negotiated prior to taking effect.  Informally,
   this specification defines compliant OCP agent behavior until changes
   to this specification (if any) are successfully negotiated.

   For example, if an RTSP profile for OCP requires support for offsets
   exceeding 2147483647 octets, the profile specification can document
   appropriate OCP changes while requiring that RTSP adaptation agents
   negotiate "large offsets" support before using large offsets.  This
   negotiation can be bundled with negotiating another feature (e.g.,
   negotiating an RTSP profile may imply support for "large offsets").

   As implied by the above rules, OCP extensions may dynamically alter
   the negotiation mechanism itself, but such an alternation would have
   to be negotiated first, using the negotiation mechanism defined by
   this specification.  For example, successfully negotiating a feature
   might change the default "Offer-Pending" value from false to true.














Rousskov                    Standards Track                    [Page 51]

RFC 4037               OPES Callout Protocol Core             March 2005


Appendix A.  Message Summary

   This appendix is not normative.  The table below summarizes key OCP
   message properties.  For each message, the table provides the
   following information:

   name: Message name as seen on the wire.

   title: Human-friendly message title.

   P: Whether this specification documents message semantics as sent by
      an OPES processor.

   S: Whether this specification documents message semantics as sent by
      a callout server.

   tie: Related messages such as associated request, response message,
      or associated state message.

   +-------+----------------------------+-------+-------+--------------+
   |  name |            title           |   P   |   S   |      tie     |
   +-------+----------------------------+-------+-------+--------------+
   |   CS  |      Connection Start      |   X   |   X   |      CE      |
   |   CE  |       Connection End       |   X   |   X   |      CS      |
   |  SGC  |    Service Group Created   |   X   |   X   |    SGD TS    |
   |  SGD  |   Service Group Destroyed  |   X   |   X   |      SGC     |
   |   TS  |      Transaction Start     |   X   |       |    TE SGC    |
   |   TE  |       Transaction End      |   X   |   X   |      TS      |
   |  AMS  |  Application Message Start |   X   |   X   |      AME     |
   |  AME  |   Application Message End  |   X   |   X   |    AMS DSS   |
   |  DUM  |        Data Use Mine       |   X   |   X   |    DUY DWP   |
   |  DUY  |       Data Use Yours       |       |   X   |    DUM DPI   |
   |  DPI  | Data Preservation Interest |       |   X   |      DUY     |
   |  DWSS |   Want Stop Sending Data   |       |   X   |   DWSR DSS   |
   |  DWSR |  Want Stop Receiving Data  |       |   X   |     DWSS     |
   |  DSS  |      Stop Sending Data     |   X   |       |     DWSS     |
   |  DWP  |      Want Data Paused      |   X   |   X   |      DPM     |
   |  DPM  |       Paused My Data       |   X   |   X   |    DWP DWM   |
   |  DWM  |       Want More Data       |   X   |   X   |      DPM     |
   |   NO  |      Negotiation Offer     |   X   |   X   |    NR SGC    |
   |   NR  |    Negotiation Response    |   X   |   X   |      NO      |
   |   PQ  |       Progress Query       |   X   |   X   |      PA      |
   |   PA  |       Progress Answer      |   X   |   X   |     PQ PR    |
   |   PR  |       Progress Report      |   X   |   X   |      PA      |
   |   AQ  |        Ability Query       |   X   |   X   |      AA      |
   |   AA  |       Ability Answer       |   X   |   X   |      AQ      |
   +-------+----------------------------+-------+-------+--------------+




Rousskov                    Standards Track                    [Page 52]

RFC 4037               OPES Callout Protocol Core             March 2005


Appendix B.  State Summary

   This appendix is not normative.  The table below summarizes OCP
   states.  Some states are maintained across multiple transactions and
   application messages.  Some correspond to a single request/response
   dialog; the asynchronous nature of most OCP message exchanges
   requires OCP agents to process other messages while waiting for a
   response to a request and, hence, while maintaining the state of the
   dialog.

   For each state, the table provides the following information:

   state: Short state label.

   birth: Messages creating this state.

   death: Messages destroying this state.

   ID: Associated identifier, if any.

   +-------------------------------+-------------+-------------+-------+
   |             state             | birth       | death       |   ID  |
   +-------------------------------+-------------+-------------+-------+
   |           connection          | CS          | CE          |       |
   |         service group         | SGC         | SGD         | sg-id |
   |          transaction          | TS          | TE          |  xid  |
   |    application message and    | AMS         | AME         |       |
   |            dataflow           |             |             |       |
   |     premature org-dataflow    | DWSR        | AME         |       |
   |          termination          |             |             |       |
   |     premature adp-dataflow    | DWSS        | DSS AME     |       |
   |          termination          |             |             |       |
   |        paused dataflow        | DPM         | DWM         |       |
   |    preservation commitment    | DUM         | DPI AME     |       |
   |          negotiation          | NO          | NR          |       |
   |        progress inquiry       | PQ          | PA          |       |
   |        ability inquiry        | PQ          | PA          |       |
   +-------------------------------+-------------+-------------+-------+













Rousskov                    Standards Track                    [Page 53]

RFC 4037               OPES Callout Protocol Core             March 2005


Appendix C.  Acknowledgements

   The author gratefully acknowledges the contributions of Abbie Barbir
   (Nortel Networks), Oskar Batuner (Independent Consultant), Larry
   Masinter (Adobe), Karel Mittig (France Telecom R&D), Markus Hofmann
   (Bell Labs), Hilarie Orman (The Purple Streak), Reinaldo Penno
   (Nortel Networks), and Martin Stecher (Webwasher), as well as an
   anonymous OPES working group participant.

   Special thanks to Marshall Rose for his xml2rfc tool.

16.  References

16.1.  Normative References

   [RFC2119]    Bradner, S., "Key words for use in RFCs to Indicate
                Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC2234]    Crocker, D. and P. Overell, "Augmented BNF for Syntax
                Specifications: ABNF", RFC 2234, November 1997.

   [RFC2396]    Berners-Lee, T., Fielding, R., and L. Masinter, "Uniform
                Resource Identifiers (URI): Generic Syntax", RFC 2396,
                August 1998.

   [RFC3835]    Barbir, A., Penno, R., Chen, R., Hofmann, M., and H.
                Orman, "An Architecture for Open Pluggable Edge Services
                (OPES)", RFC 3835, August 2004.

16.2.  Informative References

   [RFC3836]    Beck, A., Hofmann, M., Orman, H., Penno, R., and A.
                Terzis, "Requirements for Open Pluggable Edge Services
                (OPES) Callout Protocols", RFC 3836, August 2004.

   [RFC3837]    Barbir, A., Batuner, O., Srinivas, B., Hofmann, M., and
                H. Orman, "Security Threats and Risks for Open Pluggable
                Edge Services (OPES)", RFC 3837, August 2004.

   [RFC3752]    Barbir, A., Burger, E., Chen, R., McHenry, S., Orman,
                H., and R. Penno, "Open Pluggable Edge Services (OPES)
                Use Cases and Deployment Scenarios", RFC 3752, April
                2004.

   [RFC3838]    Barbir, A., Batuner, O., Beck, A., Chan, T., and H.
                Orman, "Policy, Authorization, and Enforcement
                Requirements of the Open Pluggable Edge Services
                (OPES)", RFC 3838, August 2004.



Rousskov                    Standards Track                    [Page 54]

RFC 4037               OPES Callout Protocol Core             March 2005


   [RFC3897]    Barbir, A., "Open Pluggable Edge Services (OPES)
                Entities and End Points Communication", RFC 3897,
                September 2004.

   [OPES-RULES] Beck, A. and A. Rousskov, "P: Message Processing
                Language", Work in Progress, October 2003.

   [RFC3914]    Barbir, A. and A. Rousskov, "Open Pluggable Edge
                Services (OPES) Treatment of IAB Considerations", RFC
                3914, October 2004.

   [OPES-HTTP]  Rousskov, A. and M. Stecher, "HTTP adaptation with
                OPES", Work in Progress, January 2004.

   [RFC2616]    Fielding,  R., Gettys, J., Mogul, J., Frystyk, H.,
                Masinter, L., Leach, P., and T. Berners-Lee, "Hypertext
                Transfer Protocol -- HTTP/1.1", RFC 2616, June 1999.

   [RFC3080]    Rose, M., "The Blocks Extensible Exchange Protocol
                Core", RFC 3080, March 2001.

   [RFC3238]    Floyd, S. and L. Daigle, "IAB Architectural and Policy
                Considerations for Open Pluggable Edge Services", RFC
                3238, January 2002.

Author's Address

   Alex Rousskov
   The Measurement Factory

   EMail: rousskov@measurement-factory.com
   URI:   http://www.measurement-factory.com/



















Rousskov                    Standards Track                    [Page 55]

RFC 4037               OPES Callout Protocol Core             March 2005


Full Copyright Statement

   Copyright (C) The Internet Society (2005).

   This document is subject to the rights, licenses and restrictions
   contained in BCP 78, and except as set forth therein, the authors
   retain all their rights.

   This document and the information contained herein are provided on an
   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
   OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
   ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
   INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
   INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   Intellectual Property Rights or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; nor does it represent that it has
   made any independent effort to identify any such rights.  Information
   on the procedures with respect to rights in RFC documents can be
   found in BCP 78 and BCP 79.

   Copies of IPR disclosures made to the IETF Secretariat and any
   assurances of licenses to be made available, or the result of an
   attempt made to obtain a general license or permission for the use of
   such proprietary rights by implementers or users of this
   specification can be obtained from the IETF on-line IPR repository at
   http://www.ietf.org/ipr.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights that may cover technology that may be required to implement
   this standard.  Please address the information to the IETF at ietf-
   ipr@ietf.org.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.







Rousskov                    Standards Track                    [Page 56]