💾 Archived View for gemini.spam.works › mirrors › textfiles › drugs › laughgas.txt captured on 2020-10-31 at 19:15:09.
-=-=-=-=-=-=-
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X FOLO ZONE FUN FILES X X X X FILE "1" -- Nitrous Oxide X X X X alias LAUGHING GAS X X X X by X X Z. DeBuggah of the Folo Zone Gang. X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX <^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^> < > < Content Hazard Rating -- . Pain or > < even death. > < > < Hazard Type -- . . . . .Explosion. > < > < Special Precautions -- DO NOT OVER > < TIGHTEN FITTINGS, AND USE THE SAND > < AS INSTRUCTED; NO METAL PARTS. > < > <vvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvv> YOU WILL NEED:- Ammonium Nitrate (get a good grade, it is fertilizer and comes is 50 lb. bags, also available from laboratory supply companies such as VW&R or American Scientific at considerably greater cost.) Clean Sand, fairly fine grained, 30 mesh or finer. If you collect your own, and you get fresh water sand, (rivers and streams), it will be necessary to wash it thoroughly with water and then dry is before using. You may also re- use sand that has been used to make nitrous oxide by washing it before re- using it. Electric hot plate, 500 W to 2500 W, WITH VAIRABLE HEAT. Stainless steel dial thermometer [this is the only "metal" device which may be used] that goes to 250 C (450 F). Select the Erlenmeyer flask (next item) and th thermometer so that the thermometer can reach at least to within 1/16" of the bottom of the flask through the flask stopper (see below). A 2000 to 4000 ml PYREX or KIMAX Erlenmeyer Flask. Several feet of 3/8" clear vinyl or surgical ruber tubing. At least 4 8mm I.D. glass or plastic tubing "T"'s. 1 120 degree bend 8mm I.D. PYREX GLASS elbow, with about 3" of tubing on each side of the bend. 7 6-8" long pieces of 8mm I.D. glass or plastic tubing. 3 6-8 feet long 1.5" to 2" diam glass or clear plastic pipes. 1 two hole rubber or neoprene stopper to fit the top of the Erlenlmeyer flask. One hole should fit the 8mm I.D. PYREX GLASS elbow, and the other hole should fit the stainless steel dial thermometer. 6 one hole rubber or neoprene stoppers that will fit the ends of the clear plastic or glass pipes. The holes in the stoppers must fit the straight 8mm I.D. glass or plastic tubes. Some super strength plastic trash bags, and some rubber bands. THE CHEMISTRY:- NH4NO3 --------------------> N2O + 2H2O 210 C (410 F) ammonium gently heated nitrous + two nitrate oxide water THE SET-UP:- If you've gotten this far, let me re-emphasize the importance of meeting the quality specifications of the equipment list. If you're serious enough to go for N2O, you'll want a good setup you can use a long time and enjoy the LAUGHING GAS without worrying about the generating system blasting you to kingdom come. SET-UP DIAGRAM ................................................ / \ \ \ : : : : : : : : Thermometer : .."T" : : : : : / v v : v 3/8" / __>_________===========__>_____ : ___ Tubing : | =========== | : |___| : : | | : | __>_ : :.>|__>_________===========__>_____|<.."T" : |_| \<..Glass : | =========== | : ||| ||| \ Elbow :.....>| ."T"................. | : Stopper>|| ^|| \ v | / \ | : ||| ||| \->-----------|<../ \..>|__>__ : / ||_|| \ |__>_________===========__>_____| \ : / | | \ ^ =========== ^ |<../ / | \ Erlenmeyer : ^ : | / | \ Flask : : : | / | \<....... INLET : OUTLET | /XXXXXXX|XXXXXXXXX\ SET Scrubbers SET v /XXXXXXXX|XXXXXXXX<.... Clear 1.5" | |XXXXXXXX|XXXXXXXXXX| \ to 2" Pipes | --------------------- \..... (See Detail | ||||||||||||||||||||| Ammonium Below). | | _ | Nitrate and | | /|\ | Sand | | | | | | 8mm Tubing....> | \_/ |<........ Connector ...>| |___________________| Hotplate / \|/ || || || / =<Rubber 3/8" Tubing.../ /|\ Band / \ | | Heavy Duty | | Trash Bag.>| | | | | | ------- Detail:- The Scrubbers :***********************: Stopper GAS Space Stopper : <*>TOP VIEW<*> \ : 8mm I.D. : Only fill to HERE\ \ : 8mm I.D. Tubing \ v v v v /Tubing : _====--------------------------------------------------====_ : v | | >Nitrous oxide bubbles in water> : | | v =>=====---------o o o > o o o > o o o > o o o > o o o > o o o: ---------=====>= ^ |___| : |___| ^ : ---------------------------------------------------------- : : Clear 1.5" to 2" pipe; Filled with water. : : : 3/8" Tubing ^ 3/8" Tubing From INLET ^ to OUTLET SET of "T"'s ******^***** SET of "T"'s *RAISE THIS* * END * ************ ASSEMBLY:- NOTE: hen inserting tubing through stopper holes, ALWAYS WRAP AND HOLD THE TUBING WITH A CLOTH. Also moisten the tip of the tubing and the stopper hole with glycerin, soap or spit (never oil). 1. Into the stopper with two holes, insert the thermometer far enough so that when the stopper is put into the Erlenmeyer Flask, it almost touches the bottom of the flask (but do not allow it to touch it), and then insert one end of the glass elbow far enough the stopper that is sticks out 1/4" to 1/2". Into the six one-hole stpppers, insert a piece of the 8mm I.D. glass (or plastic) tubing so that 1/2" to 3/4" protrudes from the narrow end of the stopper. 3. Now select your setup space so that there is 1.5 feet of space clear in all directions around the Hotplate, and then so that the three scrubber pipes can lie side by side where they will not be knocked over. 4. Take an approximately 2 foot piece of the 3/8" flexible tubing and connect one end to the glass elow in the two-hole stopper, and the other end to the middle of one of the 8mm I.D. glass (or hard plastic) "T"'s. 5. With short pieces (select lengths for a neat fit) of 3/8" tubing and another 8mm "T" assemble the INLET SET manifold and connect to the bottom end of the scrubbers. (Stoppers may then be inserted into the lower end of the scrubber pipes). 6. Elevate the OUT end of the scrubber pipes, so that the upper end is 6" to 8" above the inlet end <BUT NO MORE>, and then fill the pipeswith water until they are full within 4" to 8" of the top (outlet) end, and insert the outlet stoppers. [Try to get all three scrlubbers EQUALLY full.] 7. With short pieces of 3/8" tubing and two 8mm I.D. "T"'s, prepare, and connect the OUTLET SET manifold to the scrubbers in a similar manner to the way the set was connected in step 5. above. 8. To the last "T" of the OUTLET SET (of "T"'s manifold), connect a fairly long piece of 3/8" tubing to reach a "safe" location (where connection nd disconnection of the reciever "bags" will not disturb the scrubbers) and secure it. Then put the last piece of 8mm I.D. hard tubing into the free end. 9. Finally, prepare several "Reciever Bags" by inserting about an 8" piece of tubing into the top so that 3" or 4" sticks out of the "Bag" and secure it in place with a rubber band. > > > > > > > > > > > > > > > > CONGRATLULATIONS! < < < < < < < < < < < < < < You are now the proud owner of the original Folo Zone Nitrous Oxide Generator. OPERATION:- First, prepare a quantity of a mixture containing 1/3 sand and 2/3 ammonium nitrate. Then pour enough of the mixture into the erlenmeyer flask to give 1.5" to 2" in the bottom of the flask. Put the flask onto the Hotplate, and insert the two-hole stopper, firmly but not too tight. <<THIS STOPPER IS YOUR SAFETY VALVE WHILE THE SYSTEM IS OPERATING>>. - - - B-U-T - - - WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING W W A Once the heating of the mixture in the erlenmeyer flask has started A R you must REMOVE THE two-hole STOPPER FROM THE FLASK BEFORE TURNING R N OFF THE HEAT. Otherwise as the flask starts to cool off, it will N I draw water from the scrubbers back into the hot flask and may crack I N or EXPLODE the erlenmeyer flask with the STEAM formed inside. N G G WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING WARNING Now you may begin heating the flask. Turn the Hotplate to Medium or Med- High and watch the thermometer. (If the temperature climbs very fast, turn the Hotplate down, but be patient about turning it up. Occasional bubbles will be noted going through the scrubbers as the air in the system expands. At 210C (410F) a yellowish to orange-brown mist will begin filling the flask, and the bubbling through the scrubbers will become steady. At this time, adjust the upper end heights of the scrubber tubes so that each one gets about the same amount of gas passing through it. Keep your eye on the temperature, and it should not climb much over the 210-220C (410-430F) marks. Also the gas at the top of the scrubbers MUST BE PERFECTLY COLORLESS. Otherwise, turn down the heat setting. If the gas flow is to low to give a steady flow through all three scrubbers, increase the heat slightly. Once you've run your system a time or two, you'll know what your operating settings are. As soon as the gas flow is steady and clean, connect a recieving bag to the final outlet tube, and allow the bag to fill. It may be necessary to add more ammonium nitrate-sand mixture to the flask from time to time -- Wear Gloves as the flask will be HOT when removing the stopper. It is also a good idea to turn off the Hotplate while the stopper is out of the flask. ONCE YOU'VE FILLED A FEW BAGS WITH LAUGHING GAS, YOU'RE READY TO TRY SOME. JUST INHALE FROM THE BAG AND HOLD IT IN AS LONG AS YOU CAN. YOU'LL KNOW WHAT TO DO FROM THERE. -------------------------------------------------------------------------------- PCB BBS [UK] 0639 871325 2300 TO 0800 V21 V22 V22BIS V23................. --------------------------------------------------------------------------------